Gore Cardioform atrial septal occluder: deployment procedure and techniques for closing challenging secundum atrial septal defects

Ostium secundum atrial septal defects are mostly closed in the cardiac catheterisation laboratories using either Amplatzer® (Abbott Laboratories, IL) atrial septal occluder, Gore® Cardioform septal occluder and more recently using the recently approved (US FDA approval June 2019) Gore® Cardioform at...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cardiology in the young 2021-12, Vol.31 (12), p.1885-1892
Hauptverfasser: Aggarwal, Varun, Mohan, Arjun K., Bass, John, Steinberger, Julia, Said, Sameh M., Qureshi, Athar M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Ostium secundum atrial septal defects are mostly closed in the cardiac catheterisation laboratories using either Amplatzer® (Abbott Laboratories, IL) atrial septal occluder, Gore® Cardioform septal occluder and more recently using the recently approved (US FDA approval June 2019) Gore® Cardioform atrial septal defect occluder (W. L. Gore & Associates, AZ). Similar to any new device in the market, there is a learning curve to the deployment of this device. We therefore aim to report the key features about this new Gore Cardioform atrial septal defect occluder device with special emphasis on technical aspects that can be employed during transcatheter closure of challenging ostium secundum atrial septal defects using this device.
ISSN:1047-9511
1467-1107
DOI:10.1017/S1047951121003966