Hard Tissue Volume Stability Effect beyond the Bony Envelope of a Three-Dimensional Preformed Titanium Mesh with Two Different Collagen Barrier Membranes on Peri-Implant Dehiscence Defects in the Anterior Maxilla: A Randomized Clinical Trial
This single-blinded, randomized, controlled study aimed to clinically and radiographically evaluate hard tissue volume stability beyond the bony envelope using three-dimensional preformed titanium mesh (3D-PFTM) for peri-implant dehiscence defects in the anterior maxilla. A total of 28 patients who...
Gespeichert in:
Veröffentlicht in: | Materials 2021-09, Vol.14 (19), p.5618, Article 5618 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This single-blinded, randomized, controlled study aimed to clinically and radiographically evaluate hard tissue volume stability beyond the bony envelope using three-dimensional preformed titanium mesh (3D-PFTM) for peri-implant dehiscence defects in the anterior maxilla. A total of 28 patients who wished to undergo implant surgery combined with guided bone regeneration (GBR) after extraction of a single maxillary anterior tooth were randomly assigned to two groups depending on the type of collagen membrane used, additionally with the 3D-PFTM-test (n = 14, cross-linked collagen membrane; CCM) and control (n = 14, non-cross-linked collagen membrane; NCCM) groups. Each implant was evaluated radiographically using CBCT at baseline, immediately after surgery, and at 6 months postoperatively. The relative position and distances from the bony envelope to the outlines of the augmented ridge were further determined immediately after GBR and 6 months after healing. At the platform level, the mean horizontal hard tissue gain (HG) at all the sites was 2.35 +/- 0.68 mm at 6 months postoperatively. The mean HG rate was 84.25% +/- 14.19% in the CCM group and 82.56% +/- 13.04% in the NCCM group, but the difference was not significant between the groups. In all cases, HG was maintained beyond the bony envelope even after 6 months of GBR. This study suggests that 3D-PFTM should be considered a valuable option for GBR for peri-implant dehiscence defects in the anterior maxilla. In addition, 3D-PFTM may confer predictable hard tissue volume stability even after the healing period of hard tissue augmented outside the bony envelope by GBR. |
---|---|
ISSN: | 1996-1944 1996-1944 |
DOI: | 10.3390/ma14195618 |