Strength estimation of the ITER Lower Vertical Neutron Camera at thermal loading

•Analysis of the fluid dynamics in the coolant system of LVNC is presented.•Thermal and structural analyses are conducted.•Conclusions about the obtained stresses and temperatures are made. Lower Vertical Neutron Camera (LVNC) is a diagnostic system installed into the Diagnostic Rack of the ITER Low...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Fusion engineering and design 2021-09, Vol.170, p.112501, Article 112501
Hauptverfasser: Modestov, V., Lobachev, A., Kudryavtsev, A., Shagniev, O., Kalyutik, A., Zhadkovskii, A., Nemtsev, G., Ivantsivskiy, M., Taskaev, A., Seleznev, P., Khomyakov, E., Nagy, D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Analysis of the fluid dynamics in the coolant system of LVNC is presented.•Thermal and structural analyses are conducted.•Conclusions about the obtained stresses and temperatures are made. Lower Vertical Neutron Camera (LVNC) is a diagnostic system installed into the Diagnostic Rack of the ITER Lower Port #14. LVNC includes water cooling system, six detectors units, electrical feedthroughs and cables. Finite element model and finite volume model created with ANSYS software were used to obtain temperature and stress-strain state during Normal Operation and Baking modes.