Influence of frosted haptics on rotational stability of toric intraocular lenses

We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson & Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scientific reports 2021-07, Vol.11 (1), p.15099-15099, Article 15099
Hauptverfasser: Takaku, Ruriko, Nakano, Shinichiro, Iida, Masaharu, Oshika, Tetsuro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 15099
container_issue 1
container_start_page 15099
container_title Scientific reports
container_volume 11
creator Takaku, Ruriko
Nakano, Shinichiro
Iida, Masaharu
Oshika, Tetsuro
description We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson & Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics with toric-II IOL. The study consisted of two parts; experimental study and clinical, retrospective, case series. Experimental study indicated that the overall time from IOL ejection to unfolding to 11 mm was significantly shorter with toricII than toric-I IOLs (p = 0.032), due to the earlier separation of the haptics from the optic with toric-II IOL. Clinical study included 131 eyes of 99 patients who had undergone phacoemulsification and toric IOL implantation. At 3 months postoperatively, toric-II IOL showed significantly better rotational stability than toric-I IOL, including smaller residual manifest astigmatism (p = 0.018), less amount of axis misalignment from the intended axis (p = 0.04), lower incidence of misalignment > 10º (p = 0.0044), and less degree of prediction errors (p = 0.043). Postoperative uncorrected distance visual acuity tended to be better in the toric-II than in the toric-I groups, with marginal statistical difference (p = 0.057). TECNIS toric II IOL with the frosted haptics showed significantly better rotational stability than its predecessor, probably due to quicker unfolding and greater friction with the capsular bag.
doi_str_mv 10.1038/s41598-021-94293-3
format Article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_a55127cab60b4766be958ea23b8d81b7</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_a55127cab60b4766be958ea23b8d81b7</doaj_id><sourcerecordid>2554496495</sourcerecordid><originalsourceid>FETCH-LOGICAL-c583t-db0c7c39739c372da03a58c40496083187706a692cb978d627a8587ba64a2e6c3</originalsourceid><addsrcrecordid>eNp9kUlvFDEQhVuIiERJ_gCnlrhwafC-XJBQxDJSJDgkZ6vsdk888rQH242Uf49nOgLCAV-8vfpUr17XvcboHUZUvS8Mc60GRPCgGdF0oC-6C4IYHwgl5OVf5_PuupQdaosTzbB-1Z1TRhFp94vu-2ae4uJn5_s09VNOpfqxf4BDDa70ae5zqlBDmiH2pYINMdTHo7SmHFwf5pohuSVC7qOfiy9X3dkEsfjrp_2yu__86e7m63D77cvm5uPt4LiidRgtctJRLal2VJIREAWuHENMC6QoVlIiAUITZ7VUoyASFFfSgmBAvHD0stus3DHBzhxy2EN-NAmCOT2kvDWQm4noDXCOiXRgBbJMCmG95soDoVaNClvZWB9W1mGxez86f3QVn0Gf_8zhwWzTT6PaGIUSDfD2CZDTj8WXavahOB8jzD4txRDeWsBt6rRJ3_wj3aUlt_GeVKzZZ5o3FVlVriVSsp9-N4OROeZv1vxNy9-c8jdHNF2LShPPW5__oP9T9QvpE7Dl</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2554496495</pqid></control><display><type>article</type><title>Influence of frosted haptics on rotational stability of toric intraocular lenses</title><source>Nature Free</source><source>Springer_OA刊</source><source>DOAJ Directory of Open Access Journals</source><source>PubMed Central</source><source>Free Full-Text Journals in Chemistry</source><source>EZB Electronic Journals Library</source><creator>Takaku, Ruriko ; Nakano, Shinichiro ; Iida, Masaharu ; Oshika, Tetsuro</creator><creatorcontrib>Takaku, Ruriko ; Nakano, Shinichiro ; Iida, Masaharu ; Oshika, Tetsuro</creatorcontrib><description>We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson &amp; Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics with toric-II IOL. The study consisted of two parts; experimental study and clinical, retrospective, case series. Experimental study indicated that the overall time from IOL ejection to unfolding to 11 mm was significantly shorter with toricII than toric-I IOLs (p = 0.032), due to the earlier separation of the haptics from the optic with toric-II IOL. Clinical study included 131 eyes of 99 patients who had undergone phacoemulsification and toric IOL implantation. At 3 months postoperatively, toric-II IOL showed significantly better rotational stability than toric-I IOL, including smaller residual manifest astigmatism (p = 0.018), less amount of axis misalignment from the intended axis (p = 0.04), lower incidence of misalignment &gt; 10º (p = 0.0044), and less degree of prediction errors (p = 0.043). Postoperative uncorrected distance visual acuity tended to be better in the toric-II than in the toric-I groups, with marginal statistical difference (p = 0.057). TECNIS toric II IOL with the frosted haptics showed significantly better rotational stability than its predecessor, probably due to quicker unfolding and greater friction with the capsular bag.</description><identifier>ISSN: 2045-2322</identifier><identifier>EISSN: 2045-2322</identifier><identifier>DOI: 10.1038/s41598-021-94293-3</identifier><identifier>PMID: 34302005</identifier><language>eng</language><publisher>London: Nature Publishing Group UK</publisher><subject>692/699/3161 ; 692/699/3161/3168 ; Acuity ; Haptics ; Humanities and Social Sciences ; Intraocular lenses ; multidisciplinary ; Science ; Science (multidisciplinary)</subject><ispartof>Scientific reports, 2021-07, Vol.11 (1), p.15099-15099, Article 15099</ispartof><rights>The Author(s) 2021</rights><rights>The Author(s) 2021. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c583t-db0c7c39739c372da03a58c40496083187706a692cb978d627a8587ba64a2e6c3</citedby><cites>FETCH-LOGICAL-c583t-db0c7c39739c372da03a58c40496083187706a692cb978d627a8587ba64a2e6c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8302686/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8302686/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,315,728,781,785,865,886,2103,27926,27927,41122,42191,51578,53793,53795</link.rule.ids></links><search><creatorcontrib>Takaku, Ruriko</creatorcontrib><creatorcontrib>Nakano, Shinichiro</creatorcontrib><creatorcontrib>Iida, Masaharu</creatorcontrib><creatorcontrib>Oshika, Tetsuro</creatorcontrib><title>Influence of frosted haptics on rotational stability of toric intraocular lenses</title><title>Scientific reports</title><addtitle>Sci Rep</addtitle><description>We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson &amp; Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics with toric-II IOL. The study consisted of two parts; experimental study and clinical, retrospective, case series. Experimental study indicated that the overall time from IOL ejection to unfolding to 11 mm was significantly shorter with toricII than toric-I IOLs (p = 0.032), due to the earlier separation of the haptics from the optic with toric-II IOL. Clinical study included 131 eyes of 99 patients who had undergone phacoemulsification and toric IOL implantation. At 3 months postoperatively, toric-II IOL showed significantly better rotational stability than toric-I IOL, including smaller residual manifest astigmatism (p = 0.018), less amount of axis misalignment from the intended axis (p = 0.04), lower incidence of misalignment &gt; 10º (p = 0.0044), and less degree of prediction errors (p = 0.043). Postoperative uncorrected distance visual acuity tended to be better in the toric-II than in the toric-I groups, with marginal statistical difference (p = 0.057). TECNIS toric II IOL with the frosted haptics showed significantly better rotational stability than its predecessor, probably due to quicker unfolding and greater friction with the capsular bag.</description><subject>692/699/3161</subject><subject>692/699/3161/3168</subject><subject>Acuity</subject><subject>Haptics</subject><subject>Humanities and Social Sciences</subject><subject>Intraocular lenses</subject><subject>multidisciplinary</subject><subject>Science</subject><subject>Science (multidisciplinary)</subject><issn>2045-2322</issn><issn>2045-2322</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>C6C</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><sourceid>DOA</sourceid><recordid>eNp9kUlvFDEQhVuIiERJ_gCnlrhwafC-XJBQxDJSJDgkZ6vsdk888rQH242Uf49nOgLCAV-8vfpUr17XvcboHUZUvS8Mc60GRPCgGdF0oC-6C4IYHwgl5OVf5_PuupQdaosTzbB-1Z1TRhFp94vu-2ae4uJn5_s09VNOpfqxf4BDDa70ae5zqlBDmiH2pYINMdTHo7SmHFwf5pohuSVC7qOfiy9X3dkEsfjrp_2yu__86e7m63D77cvm5uPt4LiidRgtctJRLal2VJIREAWuHENMC6QoVlIiAUITZ7VUoyASFFfSgmBAvHD0stus3DHBzhxy2EN-NAmCOT2kvDWQm4noDXCOiXRgBbJMCmG95soDoVaNClvZWB9W1mGxez86f3QVn0Gf_8zhwWzTT6PaGIUSDfD2CZDTj8WXavahOB8jzD4txRDeWsBt6rRJ3_wj3aUlt_GeVKzZZ5o3FVlVriVSsp9-N4OROeZv1vxNy9-c8jdHNF2LShPPW5__oP9T9QvpE7Dl</recordid><startdate>20210723</startdate><enddate>20210723</enddate><creator>Takaku, Ruriko</creator><creator>Nakano, Shinichiro</creator><creator>Iida, Masaharu</creator><creator>Oshika, Tetsuro</creator><general>Nature Publishing Group UK</general><general>Nature Publishing Group</general><general>Nature Portfolio</general><scope>C6C</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88A</scope><scope>88E</scope><scope>88I</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>M7P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20210723</creationdate><title>Influence of frosted haptics on rotational stability of toric intraocular lenses</title><author>Takaku, Ruriko ; Nakano, Shinichiro ; Iida, Masaharu ; Oshika, Tetsuro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c583t-db0c7c39739c372da03a58c40496083187706a692cb978d627a8587ba64a2e6c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>692/699/3161</topic><topic>692/699/3161/3168</topic><topic>Acuity</topic><topic>Haptics</topic><topic>Humanities and Social Sciences</topic><topic>Intraocular lenses</topic><topic>multidisciplinary</topic><topic>Science</topic><topic>Science (multidisciplinary)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Takaku, Ruriko</creatorcontrib><creatorcontrib>Nakano, Shinichiro</creatorcontrib><creatorcontrib>Iida, Masaharu</creatorcontrib><creatorcontrib>Oshika, Tetsuro</creatorcontrib><collection>Springer_OA刊</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Biology Database (Alumni Edition)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>PML(ProQuest Medical Library)</collection><collection>ProQuest Science Journals</collection><collection>ProQuest Biological Science Journals</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Scientific reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Takaku, Ruriko</au><au>Nakano, Shinichiro</au><au>Iida, Masaharu</au><au>Oshika, Tetsuro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of frosted haptics on rotational stability of toric intraocular lenses</atitle><jtitle>Scientific reports</jtitle><stitle>Sci Rep</stitle><date>2021-07-23</date><risdate>2021</risdate><volume>11</volume><issue>1</issue><spage>15099</spage><epage>15099</epage><pages>15099-15099</pages><artnum>15099</artnum><issn>2045-2322</issn><eissn>2045-2322</eissn><abstract>We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson &amp; Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics with toric-II IOL. The study consisted of two parts; experimental study and clinical, retrospective, case series. Experimental study indicated that the overall time from IOL ejection to unfolding to 11 mm was significantly shorter with toricII than toric-I IOLs (p = 0.032), due to the earlier separation of the haptics from the optic with toric-II IOL. Clinical study included 131 eyes of 99 patients who had undergone phacoemulsification and toric IOL implantation. At 3 months postoperatively, toric-II IOL showed significantly better rotational stability than toric-I IOL, including smaller residual manifest astigmatism (p = 0.018), less amount of axis misalignment from the intended axis (p = 0.04), lower incidence of misalignment &gt; 10º (p = 0.0044), and less degree of prediction errors (p = 0.043). Postoperative uncorrected distance visual acuity tended to be better in the toric-II than in the toric-I groups, with marginal statistical difference (p = 0.057). TECNIS toric II IOL with the frosted haptics showed significantly better rotational stability than its predecessor, probably due to quicker unfolding and greater friction with the capsular bag.</abstract><cop>London</cop><pub>Nature Publishing Group UK</pub><pmid>34302005</pmid><doi>10.1038/s41598-021-94293-3</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2045-2322
ispartof Scientific reports, 2021-07, Vol.11 (1), p.15099-15099, Article 15099
issn 2045-2322
2045-2322
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_a55127cab60b4766be958ea23b8d81b7
source Nature Free; Springer_OA刊; DOAJ Directory of Open Access Journals; PubMed Central; Free Full-Text Journals in Chemistry; EZB Electronic Journals Library
subjects 692/699/3161
692/699/3161/3168
Acuity
Haptics
Humanities and Social Sciences
Intraocular lenses
multidisciplinary
Science
Science (multidisciplinary)
title Influence of frosted haptics on rotational stability of toric intraocular lenses
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T21%3A29%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20frosted%20haptics%20on%20rotational%20stability%20of%20toric%20intraocular%20lenses&rft.jtitle=Scientific%20reports&rft.au=Takaku,%20Ruriko&rft.date=2021-07-23&rft.volume=11&rft.issue=1&rft.spage=15099&rft.epage=15099&rft.pages=15099-15099&rft.artnum=15099&rft.issn=2045-2322&rft.eissn=2045-2322&rft_id=info:doi/10.1038/s41598-021-94293-3&rft_dat=%3Cproquest_doaj_%3E2554496495%3C/proquest_doaj_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2554496495&rft_id=info:pmid/34302005&rft_doaj_id=oai_doaj_org_article_a55127cab60b4766be958ea23b8d81b7&rfr_iscdi=true