Incidence, Risk Factors, and Outcome of Ceramic-On-Ceramic Bearing Breakage in Total Hip Arthroplasty

Ceramic-on-ceramic bearing breakage is a rare but significant complication of total hip arthroplasty. This study aimed to identify risk factors for breakage and to determine the outcome of different revision options. All ceramic-on-ceramic primary total hip arthroplasty procedures reported to the Au...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of arthroplasty 2021-08, Vol.36 (8), p.2992-2997
Hauptverfasser: Hoskins, Wayne, Rainbird, Sophia, Peng, Yi, Lorimer, Michelle, Graves, Stephen E., Bingham, Roger
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2997
container_issue 8
container_start_page 2992
container_title The Journal of arthroplasty
container_volume 36
creator Hoskins, Wayne
Rainbird, Sophia
Peng, Yi
Lorimer, Michelle
Graves, Stephen E.
Bingham, Roger
description Ceramic-on-ceramic bearing breakage is a rare but significant complication of total hip arthroplasty. This study aimed to identify risk factors for breakage and to determine the outcome of different revision options. All ceramic-on-ceramic primary total hip arthroplasty procedures reported to the Australian Joint Replacement Registry from September 1999 to December 2019 were included. Procedures were subdivided into alumina or mixed ceramic (alumina/zirconia). All breakages were identified. The association between ceramic type and head size was assessed. Subsequent revision rates were compared and cause of revision assessed. There were 23,534 alumina and 71,144 mixed ceramic procedures. Breakage was the reason for 1st revision in 84 alumina (5.27% of all revisions and 0.36% of procedures) and 56 mixed ceramic procedures (2.46% of all revisions; 0.08% of procedures). Alumina had a higher breakage rate than mixed ceramic (HR 2.50 (95% CI 1.75, 3.59), P < .001), and breakage was higher for 36-38mm head sizes using alumina (HR 2.84 (1.52, 5.31), P = .001). 17.8% of 2nd revisions occur by 3 years, due to dislocation, infection, metal-related pathology, and loosening. A neck adapter sleeve did not reduce 2nd revisions. Numbers were too low to compare revision bearing surface options. Ceramic breakage has reduced with mixed ceramics but has a 0.79/1000 incidence at 15-year follow-up. It is unclear what the risk factors are for modern ceramics with increasing head size a risk for alumina only. Risk of 2nd revision is high and occurs early. The optimal revision option is unknown.
doi_str_mv 10.1016/j.arth.2021.03.021
format Article
fullrecord <record><control><sourceid>proquest_webof</sourceid><recordid>TN_cdi_webofscience_primary_000674660900051</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540321002618</els_id><sourcerecordid>2508889516</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-8f09675b72977a40d42ec98e36916c0fbd64d4be557338834f727a0c95643bd83</originalsourceid><addsrcrecordid>eNqNkE1v1DAQhi0EotvCH-CAfESiCXb8EUfi0kaUVqq0Eipny3EmxdskXmynqP8eR7vtEXGaOTzvq5kHoQ-UlJRQ-WVXmpB-lRWpaElYmccrtKGCVYXiRL5GG6IUKwQn7ASdxrgjhFIh-Ft0wpiiVU3JBsHNbF0Ps4Vz_MPFB3xlbPIhnmMz93i7JOsnwH7ALQQzOVts5-K44kswwc33-DKAeTD3gN2M73wyI752e3yRbwt-P5qYnt6hN4MZI7w_zjP08-rbXXtd3G6_37QXt4VlQqZCDaSRtejqqqlrw0nPK7CNAiYbKi0Zul7ynncgRJ0_UIwPdVUbYhshOet6xc7Qp0PvPvjfC8SkJxctjKOZwS9RVyIrUY2gMqPVAbXBxxhg0PvgJhOeNCV61at3etWrV72aMJ1HDn089i_dBP1L5NlnBj4fgD_Q-SFat5p9wQghsuZSkiZvYq1T_0-3Lpnk_Nz6ZU45-vUQhazz0UHQx3jvAtike-_-9chfM72qiQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2508889516</pqid></control><display><type>article</type><title>Incidence, Risk Factors, and Outcome of Ceramic-On-Ceramic Bearing Breakage in Total Hip Arthroplasty</title><source>Elsevier ScienceDirect Journals Complete</source><source>Web of Science - Science Citation Index Expanded - 2021&lt;img src="https://exlibris-pub.s3.amazonaws.com/fromwos-v2.jpg" /&gt;</source><creator>Hoskins, Wayne ; Rainbird, Sophia ; Peng, Yi ; Lorimer, Michelle ; Graves, Stephen E. ; Bingham, Roger</creator><creatorcontrib>Hoskins, Wayne ; Rainbird, Sophia ; Peng, Yi ; Lorimer, Michelle ; Graves, Stephen E. ; Bingham, Roger</creatorcontrib><description>Ceramic-on-ceramic bearing breakage is a rare but significant complication of total hip arthroplasty. This study aimed to identify risk factors for breakage and to determine the outcome of different revision options. All ceramic-on-ceramic primary total hip arthroplasty procedures reported to the Australian Joint Replacement Registry from September 1999 to December 2019 were included. Procedures were subdivided into alumina or mixed ceramic (alumina/zirconia). All breakages were identified. The association between ceramic type and head size was assessed. Subsequent revision rates were compared and cause of revision assessed. There were 23,534 alumina and 71,144 mixed ceramic procedures. Breakage was the reason for 1st revision in 84 alumina (5.27% of all revisions and 0.36% of procedures) and 56 mixed ceramic procedures (2.46% of all revisions; 0.08% of procedures). Alumina had a higher breakage rate than mixed ceramic (HR 2.50 (95% CI 1.75, 3.59), P &lt; .001), and breakage was higher for 36-38mm head sizes using alumina (HR 2.84 (1.52, 5.31), P = .001). 17.8% of 2nd revisions occur by 3 years, due to dislocation, infection, metal-related pathology, and loosening. A neck adapter sleeve did not reduce 2nd revisions. Numbers were too low to compare revision bearing surface options. Ceramic breakage has reduced with mixed ceramics but has a 0.79/1000 incidence at 15-year follow-up. It is unclear what the risk factors are for modern ceramics with increasing head size a risk for alumina only. Risk of 2nd revision is high and occurs early. The optimal revision option is unknown.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1016/j.arth.2021.03.021</identifier><identifier>PMID: 33812710</identifier><language>eng</language><publisher>PHILADELPHIA: Elsevier Inc</publisher><subject>ceramic ; hip ; hip prosthesis ; Life Sciences &amp; Biomedicine ; Orthopedics ; osteoarthritis ; Science &amp; Technology ; total hip replacement</subject><ispartof>The Journal of arthroplasty, 2021-08, Vol.36 (8), p.2992-2997</ispartof><rights>2021 Elsevier Inc.</rights><rights>Copyright © 2021 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>true</woscitedreferencessubscribed><woscitedreferencescount>8</woscitedreferencescount><woscitedreferencesoriginalsourcerecordid>wos000674660900051</woscitedreferencesoriginalsourcerecordid><citedby>FETCH-LOGICAL-c356t-8f09675b72977a40d42ec98e36916c0fbd64d4be557338834f727a0c95643bd83</citedby><cites>FETCH-LOGICAL-c356t-8f09675b72977a40d42ec98e36916c0fbd64d4be557338834f727a0c95643bd83</cites><orcidid>0000-0003-0608-3065 ; 0000-0003-2971-9222</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.arth.2021.03.021$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,782,786,3552,27931,27932,39265,46002</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33812710$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hoskins, Wayne</creatorcontrib><creatorcontrib>Rainbird, Sophia</creatorcontrib><creatorcontrib>Peng, Yi</creatorcontrib><creatorcontrib>Lorimer, Michelle</creatorcontrib><creatorcontrib>Graves, Stephen E.</creatorcontrib><creatorcontrib>Bingham, Roger</creatorcontrib><title>Incidence, Risk Factors, and Outcome of Ceramic-On-Ceramic Bearing Breakage in Total Hip Arthroplasty</title><title>The Journal of arthroplasty</title><addtitle>J ARTHROPLASTY</addtitle><addtitle>J Arthroplasty</addtitle><description>Ceramic-on-ceramic bearing breakage is a rare but significant complication of total hip arthroplasty. This study aimed to identify risk factors for breakage and to determine the outcome of different revision options. All ceramic-on-ceramic primary total hip arthroplasty procedures reported to the Australian Joint Replacement Registry from September 1999 to December 2019 were included. Procedures were subdivided into alumina or mixed ceramic (alumina/zirconia). All breakages were identified. The association between ceramic type and head size was assessed. Subsequent revision rates were compared and cause of revision assessed. There were 23,534 alumina and 71,144 mixed ceramic procedures. Breakage was the reason for 1st revision in 84 alumina (5.27% of all revisions and 0.36% of procedures) and 56 mixed ceramic procedures (2.46% of all revisions; 0.08% of procedures). Alumina had a higher breakage rate than mixed ceramic (HR 2.50 (95% CI 1.75, 3.59), P &lt; .001), and breakage was higher for 36-38mm head sizes using alumina (HR 2.84 (1.52, 5.31), P = .001). 17.8% of 2nd revisions occur by 3 years, due to dislocation, infection, metal-related pathology, and loosening. A neck adapter sleeve did not reduce 2nd revisions. Numbers were too low to compare revision bearing surface options. Ceramic breakage has reduced with mixed ceramics but has a 0.79/1000 incidence at 15-year follow-up. It is unclear what the risk factors are for modern ceramics with increasing head size a risk for alumina only. Risk of 2nd revision is high and occurs early. The optimal revision option is unknown.</description><subject>ceramic</subject><subject>hip</subject><subject>hip prosthesis</subject><subject>Life Sciences &amp; Biomedicine</subject><subject>Orthopedics</subject><subject>osteoarthritis</subject><subject>Science &amp; Technology</subject><subject>total hip replacement</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>HGBXW</sourceid><recordid>eNqNkE1v1DAQhi0EotvCH-CAfESiCXb8EUfi0kaUVqq0Eipny3EmxdskXmynqP8eR7vtEXGaOTzvq5kHoQ-UlJRQ-WVXmpB-lRWpaElYmccrtKGCVYXiRL5GG6IUKwQn7ASdxrgjhFIh-Ft0wpiiVU3JBsHNbF0Ps4Vz_MPFB3xlbPIhnmMz93i7JOsnwH7ALQQzOVts5-K44kswwc33-DKAeTD3gN2M73wyI752e3yRbwt-P5qYnt6hN4MZI7w_zjP08-rbXXtd3G6_37QXt4VlQqZCDaSRtejqqqlrw0nPK7CNAiYbKi0Zul7ynncgRJ0_UIwPdVUbYhshOet6xc7Qp0PvPvjfC8SkJxctjKOZwS9RVyIrUY2gMqPVAbXBxxhg0PvgJhOeNCV61at3etWrV72aMJ1HDn089i_dBP1L5NlnBj4fgD_Q-SFat5p9wQghsuZSkiZvYq1T_0-3Lpnk_Nz6ZU45-vUQhazz0UHQx3jvAtike-_-9chfM72qiQ</recordid><startdate>20210801</startdate><enddate>20210801</enddate><creator>Hoskins, Wayne</creator><creator>Rainbird, Sophia</creator><creator>Peng, Yi</creator><creator>Lorimer, Michelle</creator><creator>Graves, Stephen E.</creator><creator>Bingham, Roger</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>BLEPL</scope><scope>DTL</scope><scope>HGBXW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0608-3065</orcidid><orcidid>https://orcid.org/0000-0003-2971-9222</orcidid></search><sort><creationdate>20210801</creationdate><title>Incidence, Risk Factors, and Outcome of Ceramic-On-Ceramic Bearing Breakage in Total Hip Arthroplasty</title><author>Hoskins, Wayne ; Rainbird, Sophia ; Peng, Yi ; Lorimer, Michelle ; Graves, Stephen E. ; Bingham, Roger</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-8f09675b72977a40d42ec98e36916c0fbd64d4be557338834f727a0c95643bd83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>ceramic</topic><topic>hip</topic><topic>hip prosthesis</topic><topic>Life Sciences &amp; Biomedicine</topic><topic>Orthopedics</topic><topic>osteoarthritis</topic><topic>Science &amp; Technology</topic><topic>total hip replacement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hoskins, Wayne</creatorcontrib><creatorcontrib>Rainbird, Sophia</creatorcontrib><creatorcontrib>Peng, Yi</creatorcontrib><creatorcontrib>Lorimer, Michelle</creatorcontrib><creatorcontrib>Graves, Stephen E.</creatorcontrib><creatorcontrib>Bingham, Roger</creatorcontrib><collection>Web of Science Core Collection</collection><collection>Science Citation Index Expanded</collection><collection>Web of Science - Science Citation Index Expanded - 2021</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hoskins, Wayne</au><au>Rainbird, Sophia</au><au>Peng, Yi</au><au>Lorimer, Michelle</au><au>Graves, Stephen E.</au><au>Bingham, Roger</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Incidence, Risk Factors, and Outcome of Ceramic-On-Ceramic Bearing Breakage in Total Hip Arthroplasty</atitle><jtitle>The Journal of arthroplasty</jtitle><stitle>J ARTHROPLASTY</stitle><addtitle>J Arthroplasty</addtitle><date>2021-08-01</date><risdate>2021</risdate><volume>36</volume><issue>8</issue><spage>2992</spage><epage>2997</epage><pages>2992-2997</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>Ceramic-on-ceramic bearing breakage is a rare but significant complication of total hip arthroplasty. This study aimed to identify risk factors for breakage and to determine the outcome of different revision options. All ceramic-on-ceramic primary total hip arthroplasty procedures reported to the Australian Joint Replacement Registry from September 1999 to December 2019 were included. Procedures were subdivided into alumina or mixed ceramic (alumina/zirconia). All breakages were identified. The association between ceramic type and head size was assessed. Subsequent revision rates were compared and cause of revision assessed. There were 23,534 alumina and 71,144 mixed ceramic procedures. Breakage was the reason for 1st revision in 84 alumina (5.27% of all revisions and 0.36% of procedures) and 56 mixed ceramic procedures (2.46% of all revisions; 0.08% of procedures). Alumina had a higher breakage rate than mixed ceramic (HR 2.50 (95% CI 1.75, 3.59), P &lt; .001), and breakage was higher for 36-38mm head sizes using alumina (HR 2.84 (1.52, 5.31), P = .001). 17.8% of 2nd revisions occur by 3 years, due to dislocation, infection, metal-related pathology, and loosening. A neck adapter sleeve did not reduce 2nd revisions. Numbers were too low to compare revision bearing surface options. Ceramic breakage has reduced with mixed ceramics but has a 0.79/1000 incidence at 15-year follow-up. It is unclear what the risk factors are for modern ceramics with increasing head size a risk for alumina only. Risk of 2nd revision is high and occurs early. The optimal revision option is unknown.</abstract><cop>PHILADELPHIA</cop><pub>Elsevier Inc</pub><pmid>33812710</pmid><doi>10.1016/j.arth.2021.03.021</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0003-0608-3065</orcidid><orcidid>https://orcid.org/0000-0003-2971-9222</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0883-5403
ispartof The Journal of arthroplasty, 2021-08, Vol.36 (8), p.2992-2997
issn 0883-5403
1532-8406
language eng
recordid cdi_webofscience_primary_000674660900051
source Elsevier ScienceDirect Journals Complete; Web of Science - Science Citation Index Expanded - 2021<img src="https://exlibris-pub.s3.amazonaws.com/fromwos-v2.jpg" />
subjects ceramic
hip
hip prosthesis
Life Sciences & Biomedicine
Orthopedics
osteoarthritis
Science & Technology
total hip replacement
title Incidence, Risk Factors, and Outcome of Ceramic-On-Ceramic Bearing Breakage in Total Hip Arthroplasty
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-05T01%3A25%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_webof&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Incidence,%20Risk%20Factors,%20and%20Outcome%20of%20Ceramic-On-Ceramic%20Bearing%20Breakage%20in%20Total%20Hip%20Arthroplasty&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Hoskins,%20Wayne&rft.date=2021-08-01&rft.volume=36&rft.issue=8&rft.spage=2992&rft.epage=2997&rft.pages=2992-2997&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1016/j.arth.2021.03.021&rft_dat=%3Cproquest_webof%3E2508889516%3C/proquest_webof%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2508889516&rft_id=info:pmid/33812710&rft_els_id=S0883540321002618&rfr_iscdi=true