Enhanced identification of defective pre-coated paints on metal through simple temperature-perturbed infrared measurement in conjunction with two-trace two-dimensional correlation analysis

[Display omitted] •Temperature-perturbed IR measurement was proposed to identify defective pre-coated paints.•It was to induce dissimilar temperature-driven structural variations of paint and contaminants.•To effectively recognize the dissimilar behaviors, 2T2D correlation analysis was adopted.•When...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy Molecular and biomolecular spectroscopy, 2021-11, Vol.260, p.119936, Article 119936
Hauptverfasser: Ma, Youngtaek, Seol, Daun, Nam, Kyungmin, Sohng, Woosuk, Chung, Hoeil
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •Temperature-perturbed IR measurement was proposed to identify defective pre-coated paints.•It was to induce dissimilar temperature-driven structural variations of paint and contaminants.•To effectively recognize the dissimilar behaviors, 2T2D correlation analysis was adopted.•When IR sample spectra at either 20 or 50 °C were used, the defect identification was inferior.•2T2D correlation analysis of both spectra enabled the more accurate defect identification. A promising infrared (IR) spectroscopic method able to effectively identify defective pre-coated metal (PCM), a pre-painted metal panel, has been demonstrated. A temperature-perturbed IR measurement in conjunction with a two-trace two-dimensional (2T2D) correlation analysis was proposed as a strategy for enhancing defect identification. Our objectives were to induce dissimilar temperature-driven structural variations of base paints and added components, to recognize dissimilarities by 2T2D correlation analysis, and to use subsequent 2T2D correlation features to identify sample defects. For the exploratory examination, three defect cases were studied: 1) grey-silver PCMs with and without phosphate epoxy (2.0%), 2) normal and violet colorant-contaminated (0.2%) black PCMs, and 3) normal, violet (0.5%), and yellow colorant-contaminated (0.1%) white PCMs. The IR spectral features of the PCMs collected at 20 and 50 °C were different due to the temperature-dependent structural variations. Initial measurements at 50 °C allowed discrimination of normal and violet colorant-contaminated black PCMs. When using 2T2D slice spectra obtained from 2T2D correlation analysis using the spectra measured at the two temperatures, violet- as well as yellow colorant-contaminated white PCMs were identified, while these were unclear in the measurements at either 20 or 50 °C. The effective capture of dissimilar temperature-driven spectral variations of base paint and colorants (contaminants) by 2T2D correlation analysis was responsible for the improved defect identification.
ISSN:1386-1425
1873-3557
DOI:10.1016/j.saa.2021.119936