A comparative study of the accuracy between two computer-aided surgical simulation methods in virtual surgical planning

The aim of this retrospective and observational study was to compare the accuracy of two different virtual surgical planning (VSP) protocols, namely, the CASS method and the modified CASS method. The patients underwent bimaxillary orthognathic surgery, planned using either the CASS method or the mod...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cranio-maxillo-facial surgery 2021-02, Vol.49 (2), p.84-92
Hauptverfasser: Ferraz, Flavio Wellington da Silva, Iwaki-Filho, Liogi, Souza-Pinto, Gustavo Nascimento de, Iwaki, Lilian Cristina Vessoni, Li, An Tien, Cardoso, Mauricio de Almeida
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 92
container_issue 2
container_start_page 84
container_title Journal of cranio-maxillo-facial surgery
container_volume 49
creator Ferraz, Flavio Wellington da Silva
Iwaki-Filho, Liogi
Souza-Pinto, Gustavo Nascimento de
Iwaki, Lilian Cristina Vessoni
Li, An Tien
Cardoso, Mauricio de Almeida
description The aim of this retrospective and observational study was to compare the accuracy of two different virtual surgical planning (VSP) protocols, namely, the CASS method and the modified CASS method. The patients underwent bimaxillary orthognathic surgery, planned using either the CASS method or the modified CASS method. Linear and angular discrepancies between the VSP outcome and postoperative outcome for both groups were compared for maxilla, mandible, and chin segments. Aside from the comparison between both groups, additional criteria were used to determine the accuracy of the protocol based on a linear and angular difference between planned and actual outcomes of less than 2 mm and 4°, respectively. The intergroup comparisons were performed by one-way ANOVA, with the level of significance set at 5%. A total of 21 patients, of both genders, were assigned into group I (n = 11), planned with the CASS method, and group II (n = 10), planned with the modified CASS method. Both the CASS and modified CASS methods presented similar accuracy with regard to linear differences for the maxilla, mandible, and chin segments, except for ΔX for the mandibular segment, where the modified CASS method showed slightly better accuracy. However, there was a statistically significant difference with regard to angular differences in the chin segment, with the CASS method shown to be the more accurate. Aside from Δpitch for the chin segment, no linear or angular differences exceeded 2 mm or 4°. Although statistically significant differences were found with regard to angular measurements in the chin segment, the accuracy of the modified CASS method for virtual planning can be considered as clinically equivalent, with a performance comparable to that of the CASS method.
doi_str_mv 10.1016/j.jcms.2020.12.002
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2473902807</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1010518220302614</els_id><sourcerecordid>2473902807</sourcerecordid><originalsourceid>FETCH-LOGICAL-c422t-d37083b2f91dc91220077561eee0ddd43bfdf51f120d11b137f164110c06ccf33</originalsourceid><addsrcrecordid>eNp9kE1vEzEQhleIipaWP8AB-chl0xl7sx8Sl6oqUKkSl_Zsee1x62h3HfyRKP8eh7QcOXnkeebVzFNVnxFWCNheb1YbPccVB14--AqAv6susO_6ukEc3pcaEOo19vy8-hjjBgBa6IcP1bkQomuhwYtqf8O0n7cqqOR2xGLK5sC8ZemFmNI6B6UPbKS0J1pY2vu_dE4UauUMGRZzeHZaTSy6OU8lxC9spvTiTWRuYTsXUj5237DtpJbFLc9X1ZlVU6RPr-9l9fT97vH2Z_3w68f97c1DrRvOU21EB70YuR3Q6AE5B-i6dYtEBMaYRozW2DVa5GAQRxSdxbZcDxpara0Ql9XXU-42-N-ZYpKzi5qmsgb5HCVvOjEA76ErKD-hOvgYA1m5DW5W4SAR5FG43MijcHkULpHLIrwMfXnNz-NM5t_Im-ECfDsBVK7cOQoyakeLJuMC6SSNd__L_wMLJJOn</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2473902807</pqid></control><display><type>article</type><title>A comparative study of the accuracy between two computer-aided surgical simulation methods in virtual surgical planning</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Ferraz, Flavio Wellington da Silva ; Iwaki-Filho, Liogi ; Souza-Pinto, Gustavo Nascimento de ; Iwaki, Lilian Cristina Vessoni ; Li, An Tien ; Cardoso, Mauricio de Almeida</creator><creatorcontrib>Ferraz, Flavio Wellington da Silva ; Iwaki-Filho, Liogi ; Souza-Pinto, Gustavo Nascimento de ; Iwaki, Lilian Cristina Vessoni ; Li, An Tien ; Cardoso, Mauricio de Almeida</creatorcontrib><description>The aim of this retrospective and observational study was to compare the accuracy of two different virtual surgical planning (VSP) protocols, namely, the CASS method and the modified CASS method. The patients underwent bimaxillary orthognathic surgery, planned using either the CASS method or the modified CASS method. Linear and angular discrepancies between the VSP outcome and postoperative outcome for both groups were compared for maxilla, mandible, and chin segments. Aside from the comparison between both groups, additional criteria were used to determine the accuracy of the protocol based on a linear and angular difference between planned and actual outcomes of less than 2 mm and 4°, respectively. The intergroup comparisons were performed by one-way ANOVA, with the level of significance set at 5%. A total of 21 patients, of both genders, were assigned into group I (n = 11), planned with the CASS method, and group II (n = 10), planned with the modified CASS method. Both the CASS and modified CASS methods presented similar accuracy with regard to linear differences for the maxilla, mandible, and chin segments, except for ΔX for the mandibular segment, where the modified CASS method showed slightly better accuracy. However, there was a statistically significant difference with regard to angular differences in the chin segment, with the CASS method shown to be the more accurate. Aside from Δpitch for the chin segment, no linear or angular differences exceeded 2 mm or 4°. Although statistically significant differences were found with regard to angular measurements in the chin segment, the accuracy of the modified CASS method for virtual planning can be considered as clinically equivalent, with a performance comparable to that of the CASS method.</description><identifier>ISSN: 1010-5182</identifier><identifier>EISSN: 1878-4119</identifier><identifier>DOI: 10.1016/j.jcms.2020.12.002</identifier><identifier>PMID: 33376041</identifier><language>eng</language><publisher>Scotland: Elsevier Ltd</publisher><subject>Computed tomography ; Computer-aided surgery ; Computers ; Dentistry ; Female ; Humans ; Imaging, Three-Dimensional ; Male ; Orthognathic Surgery ; Orthognathic Surgical Procedures ; Osteotomy ; Patient Care Planning ; Retrospective Studies ; Surgery, Computer-Assisted ; Virtual surgical planning</subject><ispartof>Journal of cranio-maxillo-facial surgery, 2021-02, Vol.49 (2), p.84-92</ispartof><rights>2020 European Association for Cranio-Maxillo-Facial Surgery</rights><rights>Copyright © 2020 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c422t-d37083b2f91dc91220077561eee0ddd43bfdf51f120d11b137f164110c06ccf33</citedby><cites>FETCH-LOGICAL-c422t-d37083b2f91dc91220077561eee0ddd43bfdf51f120d11b137f164110c06ccf33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jcms.2020.12.002$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33376041$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ferraz, Flavio Wellington da Silva</creatorcontrib><creatorcontrib>Iwaki-Filho, Liogi</creatorcontrib><creatorcontrib>Souza-Pinto, Gustavo Nascimento de</creatorcontrib><creatorcontrib>Iwaki, Lilian Cristina Vessoni</creatorcontrib><creatorcontrib>Li, An Tien</creatorcontrib><creatorcontrib>Cardoso, Mauricio de Almeida</creatorcontrib><title>A comparative study of the accuracy between two computer-aided surgical simulation methods in virtual surgical planning</title><title>Journal of cranio-maxillo-facial surgery</title><addtitle>J Craniomaxillofac Surg</addtitle><description>The aim of this retrospective and observational study was to compare the accuracy of two different virtual surgical planning (VSP) protocols, namely, the CASS method and the modified CASS method. The patients underwent bimaxillary orthognathic surgery, planned using either the CASS method or the modified CASS method. Linear and angular discrepancies between the VSP outcome and postoperative outcome for both groups were compared for maxilla, mandible, and chin segments. Aside from the comparison between both groups, additional criteria were used to determine the accuracy of the protocol based on a linear and angular difference between planned and actual outcomes of less than 2 mm and 4°, respectively. The intergroup comparisons were performed by one-way ANOVA, with the level of significance set at 5%. A total of 21 patients, of both genders, were assigned into group I (n = 11), planned with the CASS method, and group II (n = 10), planned with the modified CASS method. Both the CASS and modified CASS methods presented similar accuracy with regard to linear differences for the maxilla, mandible, and chin segments, except for ΔX for the mandibular segment, where the modified CASS method showed slightly better accuracy. However, there was a statistically significant difference with regard to angular differences in the chin segment, with the CASS method shown to be the more accurate. Aside from Δpitch for the chin segment, no linear or angular differences exceeded 2 mm or 4°. Although statistically significant differences were found with regard to angular measurements in the chin segment, the accuracy of the modified CASS method for virtual planning can be considered as clinically equivalent, with a performance comparable to that of the CASS method.</description><subject>Computed tomography</subject><subject>Computer-aided surgery</subject><subject>Computers</subject><subject>Dentistry</subject><subject>Female</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional</subject><subject>Male</subject><subject>Orthognathic Surgery</subject><subject>Orthognathic Surgical Procedures</subject><subject>Osteotomy</subject><subject>Patient Care Planning</subject><subject>Retrospective Studies</subject><subject>Surgery, Computer-Assisted</subject><subject>Virtual surgical planning</subject><issn>1010-5182</issn><issn>1878-4119</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1vEzEQhleIipaWP8AB-chl0xl7sx8Sl6oqUKkSl_Zsee1x62h3HfyRKP8eh7QcOXnkeebVzFNVnxFWCNheb1YbPccVB14--AqAv6susO_6ukEc3pcaEOo19vy8-hjjBgBa6IcP1bkQomuhwYtqf8O0n7cqqOR2xGLK5sC8ZemFmNI6B6UPbKS0J1pY2vu_dE4UauUMGRZzeHZaTSy6OU8lxC9spvTiTWRuYTsXUj5237DtpJbFLc9X1ZlVU6RPr-9l9fT97vH2Z_3w68f97c1DrRvOU21EB70YuR3Q6AE5B-i6dYtEBMaYRozW2DVa5GAQRxSdxbZcDxpara0Ql9XXU-42-N-ZYpKzi5qmsgb5HCVvOjEA76ErKD-hOvgYA1m5DW5W4SAR5FG43MijcHkULpHLIrwMfXnNz-NM5t_Im-ECfDsBVK7cOQoyakeLJuMC6SSNd__L_wMLJJOn</recordid><startdate>202102</startdate><enddate>202102</enddate><creator>Ferraz, Flavio Wellington da Silva</creator><creator>Iwaki-Filho, Liogi</creator><creator>Souza-Pinto, Gustavo Nascimento de</creator><creator>Iwaki, Lilian Cristina Vessoni</creator><creator>Li, An Tien</creator><creator>Cardoso, Mauricio de Almeida</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202102</creationdate><title>A comparative study of the accuracy between two computer-aided surgical simulation methods in virtual surgical planning</title><author>Ferraz, Flavio Wellington da Silva ; Iwaki-Filho, Liogi ; Souza-Pinto, Gustavo Nascimento de ; Iwaki, Lilian Cristina Vessoni ; Li, An Tien ; Cardoso, Mauricio de Almeida</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c422t-d37083b2f91dc91220077561eee0ddd43bfdf51f120d11b137f164110c06ccf33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Computed tomography</topic><topic>Computer-aided surgery</topic><topic>Computers</topic><topic>Dentistry</topic><topic>Female</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional</topic><topic>Male</topic><topic>Orthognathic Surgery</topic><topic>Orthognathic Surgical Procedures</topic><topic>Osteotomy</topic><topic>Patient Care Planning</topic><topic>Retrospective Studies</topic><topic>Surgery, Computer-Assisted</topic><topic>Virtual surgical planning</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ferraz, Flavio Wellington da Silva</creatorcontrib><creatorcontrib>Iwaki-Filho, Liogi</creatorcontrib><creatorcontrib>Souza-Pinto, Gustavo Nascimento de</creatorcontrib><creatorcontrib>Iwaki, Lilian Cristina Vessoni</creatorcontrib><creatorcontrib>Li, An Tien</creatorcontrib><creatorcontrib>Cardoso, Mauricio de Almeida</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of cranio-maxillo-facial surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ferraz, Flavio Wellington da Silva</au><au>Iwaki-Filho, Liogi</au><au>Souza-Pinto, Gustavo Nascimento de</au><au>Iwaki, Lilian Cristina Vessoni</au><au>Li, An Tien</au><au>Cardoso, Mauricio de Almeida</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A comparative study of the accuracy between two computer-aided surgical simulation methods in virtual surgical planning</atitle><jtitle>Journal of cranio-maxillo-facial surgery</jtitle><addtitle>J Craniomaxillofac Surg</addtitle><date>2021-02</date><risdate>2021</risdate><volume>49</volume><issue>2</issue><spage>84</spage><epage>92</epage><pages>84-92</pages><issn>1010-5182</issn><eissn>1878-4119</eissn><abstract>The aim of this retrospective and observational study was to compare the accuracy of two different virtual surgical planning (VSP) protocols, namely, the CASS method and the modified CASS method. The patients underwent bimaxillary orthognathic surgery, planned using either the CASS method or the modified CASS method. Linear and angular discrepancies between the VSP outcome and postoperative outcome for both groups were compared for maxilla, mandible, and chin segments. Aside from the comparison between both groups, additional criteria were used to determine the accuracy of the protocol based on a linear and angular difference between planned and actual outcomes of less than 2 mm and 4°, respectively. The intergroup comparisons were performed by one-way ANOVA, with the level of significance set at 5%. A total of 21 patients, of both genders, were assigned into group I (n = 11), planned with the CASS method, and group II (n = 10), planned with the modified CASS method. Both the CASS and modified CASS methods presented similar accuracy with regard to linear differences for the maxilla, mandible, and chin segments, except for ΔX for the mandibular segment, where the modified CASS method showed slightly better accuracy. However, there was a statistically significant difference with regard to angular differences in the chin segment, with the CASS method shown to be the more accurate. Aside from Δpitch for the chin segment, no linear or angular differences exceeded 2 mm or 4°. Although statistically significant differences were found with regard to angular measurements in the chin segment, the accuracy of the modified CASS method for virtual planning can be considered as clinically equivalent, with a performance comparable to that of the CASS method.</abstract><cop>Scotland</cop><pub>Elsevier Ltd</pub><pmid>33376041</pmid><doi>10.1016/j.jcms.2020.12.002</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1010-5182
ispartof Journal of cranio-maxillo-facial surgery, 2021-02, Vol.49 (2), p.84-92
issn 1010-5182
1878-4119
language eng
recordid cdi_proquest_miscellaneous_2473902807
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Computed tomography
Computer-aided surgery
Computers
Dentistry
Female
Humans
Imaging, Three-Dimensional
Male
Orthognathic Surgery
Orthognathic Surgical Procedures
Osteotomy
Patient Care Planning
Retrospective Studies
Surgery, Computer-Assisted
Virtual surgical planning
title A comparative study of the accuracy between two computer-aided surgical simulation methods in virtual surgical planning
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T21%3A31%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20comparative%20study%20of%20the%20accuracy%20between%20two%20computer-aided%20surgical%20simulation%20methods%20in%20virtual%20surgical%20planning&rft.jtitle=Journal%20of%20cranio-maxillo-facial%20surgery&rft.au=Ferraz,%20Flavio%20Wellington%20da%20Silva&rft.date=2021-02&rft.volume=49&rft.issue=2&rft.spage=84&rft.epage=92&rft.pages=84-92&rft.issn=1010-5182&rft.eissn=1878-4119&rft_id=info:doi/10.1016/j.jcms.2020.12.002&rft_dat=%3Cproquest_cross%3E2473902807%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2473902807&rft_id=info:pmid/33376041&rft_els_id=S1010518220302614&rfr_iscdi=true