Scaling Flat-Plate, Low-Temperature Adiabatic Effectiveness Results Using the Advective Capacity Ratio

Design of film-cooled engine components requires the ability to predict behavior at engine conditions through low-temperature testing. The adiabatic effectiveness, η, is one indicator film cooling performance. An experiment to measure η in a low-temperature experiment requires appropriate selection...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of turbomachinery 2020-08, Vol.142 (8), Article 081010
Hauptverfasser: Fischer, Jacob P, McNamara, Luke J, Rutledge, James L, Polanka, Marc D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 8
container_start_page
container_title Journal of turbomachinery
container_volume 142
creator Fischer, Jacob P
McNamara, Luke J
Rutledge, James L
Polanka, Marc D
description Design of film-cooled engine components requires the ability to predict behavior at engine conditions through low-temperature testing. The adiabatic effectiveness, η, is one indicator film cooling performance. An experiment to measure η in a low-temperature experiment requires appropriate selection of the coolant flowrate. The mass flux ratio, M, is usually used in lieu of the velocity ratio to account for the fact that the coolant density is larger than that of the hot freestream at engine conditions. Numerous studies have evaluated the ability of M to scale η with mixed results. The momentum flux ratio, I, is an alternative also found to have mixed success, leading some to recommend matching the density ratio to allow simultaneous matching of M and I. Nevertheless, inconsistent results in the literature regarding the efficacy of these coolant flowrate parameters to scale the density ratio suggest other properties also play a role. Experiments were performed to measure η on a flat plate with a 7-7-7-shaped hole. Various coolant gases were used to give a large range of property variations. We show that a relatively new coolant flowrate parameter that accounts for density and specific heat, the advective capacity ratio, far exceeds the ability of either M or I to provide matched η between the various coolant gases that exhibit extreme property differences. With the specific heat of coolant in an engine significantly lower than that of the freestream, advective capacity ratio (ACR) is appropriate for scaling η with non-separating coolant flow.
doi_str_mv 10.1115/1.4046544
format Article
fullrecord <record><control><sourceid>asme_webof</sourceid><recordid>TN_cdi_webofscience_primary_000560394100010</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1075074</sourcerecordid><originalsourceid>FETCH-LOGICAL-a285t-1506317ab186e812b60951cb51d4c4312ab137fd863f846d8e3ecf7dceff37773</originalsourceid><addsrcrecordid>eNqNkEFLw0AQhRdRsFYP3j3kKpo6091NtkcJrQoFpbbgLWw2s5rSJiW7aem_d0uLZy8zA-97w8xj7BZhgIjyCQcCRCKFOGM9lEMVqxHAOeuBUqNYgvi6ZFfOLQGQcyl6zH4avarq72iy0j7-CIUeo2mzi-e03lCrfddS9FxWutC-MtHYWjK-2lJNzkUzct3Ku2jhDhv8z4HcHvUo0xttKr-PZsHYXLMLq1eObk69zxaT8Tx7jafvL2_Z8zTWQyV9jBISjqkuUCWkcFgkMJJoComlMILjMCg8taVKuFUiKRVxMjYtDVnL0zTlfXZ_3GvaxrmWbL5pq7Vu9zlCfggox_wUUGDVkd1R0VhnKqoN_fEAIBPgI4FhQsgqf_ijzpqu9sH68H9roO-OtHZrypdN19Yhg3BRKiEV_BdCZ4I0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Scaling Flat-Plate, Low-Temperature Adiabatic Effectiveness Results Using the Advective Capacity Ratio</title><source>ASME Transactions Journals (Current)</source><source>Web of Science - Science Citation Index Expanded - 2020&lt;img src="https://exlibris-pub.s3.amazonaws.com/fromwos-v2.jpg" /&gt;</source><source>Alma/SFX Local Collection</source><creator>Fischer, Jacob P ; McNamara, Luke J ; Rutledge, James L ; Polanka, Marc D</creator><creatorcontrib>Fischer, Jacob P ; McNamara, Luke J ; Rutledge, James L ; Polanka, Marc D</creatorcontrib><description>Design of film-cooled engine components requires the ability to predict behavior at engine conditions through low-temperature testing. The adiabatic effectiveness, η, is one indicator film cooling performance. An experiment to measure η in a low-temperature experiment requires appropriate selection of the coolant flowrate. The mass flux ratio, M, is usually used in lieu of the velocity ratio to account for the fact that the coolant density is larger than that of the hot freestream at engine conditions. Numerous studies have evaluated the ability of M to scale η with mixed results. The momentum flux ratio, I, is an alternative also found to have mixed success, leading some to recommend matching the density ratio to allow simultaneous matching of M and I. Nevertheless, inconsistent results in the literature regarding the efficacy of these coolant flowrate parameters to scale the density ratio suggest other properties also play a role. Experiments were performed to measure η on a flat plate with a 7-7-7-shaped hole. Various coolant gases were used to give a large range of property variations. We show that a relatively new coolant flowrate parameter that accounts for density and specific heat, the advective capacity ratio, far exceeds the ability of either M or I to provide matched η between the various coolant gases that exhibit extreme property differences. With the specific heat of coolant in an engine significantly lower than that of the freestream, advective capacity ratio (ACR) is appropriate for scaling η with non-separating coolant flow.</description><identifier>ISSN: 0889-504X</identifier><identifier>EISSN: 1528-8900</identifier><identifier>DOI: 10.1115/1.4046544</identifier><language>eng</language><publisher>NEW YORK: ASME</publisher><subject>Engineering ; Engineering, Mechanical ; Science &amp; Technology ; Technology</subject><ispartof>Journal of turbomachinery, 2020-08, Vol.142 (8), Article 081010</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>true</woscitedreferencessubscribed><woscitedreferencescount>31</woscitedreferencescount><woscitedreferencesoriginalsourcerecordid>wos000560394100010</woscitedreferencesoriginalsourcerecordid><citedby>FETCH-LOGICAL-a285t-1506317ab186e812b60951cb51d4c4312ab137fd863f846d8e3ecf7dceff37773</citedby><cites>FETCH-LOGICAL-a285t-1506317ab186e812b60951cb51d4c4312ab137fd863f846d8e3ecf7dceff37773</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930,28253,38525</link.rule.ids></links><search><creatorcontrib>Fischer, Jacob P</creatorcontrib><creatorcontrib>McNamara, Luke J</creatorcontrib><creatorcontrib>Rutledge, James L</creatorcontrib><creatorcontrib>Polanka, Marc D</creatorcontrib><title>Scaling Flat-Plate, Low-Temperature Adiabatic Effectiveness Results Using the Advective Capacity Ratio</title><title>Journal of turbomachinery</title><addtitle>J. Turbomach</addtitle><addtitle>J TURBOMACH</addtitle><description>Design of film-cooled engine components requires the ability to predict behavior at engine conditions through low-temperature testing. The adiabatic effectiveness, η, is one indicator film cooling performance. An experiment to measure η in a low-temperature experiment requires appropriate selection of the coolant flowrate. The mass flux ratio, M, is usually used in lieu of the velocity ratio to account for the fact that the coolant density is larger than that of the hot freestream at engine conditions. Numerous studies have evaluated the ability of M to scale η with mixed results. The momentum flux ratio, I, is an alternative also found to have mixed success, leading some to recommend matching the density ratio to allow simultaneous matching of M and I. Nevertheless, inconsistent results in the literature regarding the efficacy of these coolant flowrate parameters to scale the density ratio suggest other properties also play a role. Experiments were performed to measure η on a flat plate with a 7-7-7-shaped hole. Various coolant gases were used to give a large range of property variations. We show that a relatively new coolant flowrate parameter that accounts for density and specific heat, the advective capacity ratio, far exceeds the ability of either M or I to provide matched η between the various coolant gases that exhibit extreme property differences. With the specific heat of coolant in an engine significantly lower than that of the freestream, advective capacity ratio (ACR) is appropriate for scaling η with non-separating coolant flow.</description><subject>Engineering</subject><subject>Engineering, Mechanical</subject><subject>Science &amp; Technology</subject><subject>Technology</subject><issn>0889-504X</issn><issn>1528-8900</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>AOWDO</sourceid><recordid>eNqNkEFLw0AQhRdRsFYP3j3kKpo6091NtkcJrQoFpbbgLWw2s5rSJiW7aem_d0uLZy8zA-97w8xj7BZhgIjyCQcCRCKFOGM9lEMVqxHAOeuBUqNYgvi6ZFfOLQGQcyl6zH4avarq72iy0j7-CIUeo2mzi-e03lCrfddS9FxWutC-MtHYWjK-2lJNzkUzct3Ku2jhDhv8z4HcHvUo0xttKr-PZsHYXLMLq1eObk69zxaT8Tx7jafvL2_Z8zTWQyV9jBISjqkuUCWkcFgkMJJoComlMILjMCg8taVKuFUiKRVxMjYtDVnL0zTlfXZ_3GvaxrmWbL5pq7Vu9zlCfggox_wUUGDVkd1R0VhnKqoN_fEAIBPgI4FhQsgqf_ijzpqu9sH68H9roO-OtHZrypdN19Yhg3BRKiEV_BdCZ4I0</recordid><startdate>20200801</startdate><enddate>20200801</enddate><creator>Fischer, Jacob P</creator><creator>McNamara, Luke J</creator><creator>Rutledge, James L</creator><creator>Polanka, Marc D</creator><general>ASME</general><general>Asme</general><scope>AOWDO</scope><scope>BLEPL</scope><scope>DTL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20200801</creationdate><title>Scaling Flat-Plate, Low-Temperature Adiabatic Effectiveness Results Using the Advective Capacity Ratio</title><author>Fischer, Jacob P ; McNamara, Luke J ; Rutledge, James L ; Polanka, Marc D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a285t-1506317ab186e812b60951cb51d4c4312ab137fd863f846d8e3ecf7dceff37773</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Engineering</topic><topic>Engineering, Mechanical</topic><topic>Science &amp; Technology</topic><topic>Technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fischer, Jacob P</creatorcontrib><creatorcontrib>McNamara, Luke J</creatorcontrib><creatorcontrib>Rutledge, James L</creatorcontrib><creatorcontrib>Polanka, Marc D</creatorcontrib><collection>Web of Science - Science Citation Index Expanded - 2020</collection><collection>Web of Science Core Collection</collection><collection>Science Citation Index Expanded</collection><collection>CrossRef</collection><jtitle>Journal of turbomachinery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fischer, Jacob P</au><au>McNamara, Luke J</au><au>Rutledge, James L</au><au>Polanka, Marc D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Scaling Flat-Plate, Low-Temperature Adiabatic Effectiveness Results Using the Advective Capacity Ratio</atitle><jtitle>Journal of turbomachinery</jtitle><stitle>J. Turbomach</stitle><stitle>J TURBOMACH</stitle><date>2020-08-01</date><risdate>2020</risdate><volume>142</volume><issue>8</issue><artnum>081010</artnum><issn>0889-504X</issn><eissn>1528-8900</eissn><abstract>Design of film-cooled engine components requires the ability to predict behavior at engine conditions through low-temperature testing. The adiabatic effectiveness, η, is one indicator film cooling performance. An experiment to measure η in a low-temperature experiment requires appropriate selection of the coolant flowrate. The mass flux ratio, M, is usually used in lieu of the velocity ratio to account for the fact that the coolant density is larger than that of the hot freestream at engine conditions. Numerous studies have evaluated the ability of M to scale η with mixed results. The momentum flux ratio, I, is an alternative also found to have mixed success, leading some to recommend matching the density ratio to allow simultaneous matching of M and I. Nevertheless, inconsistent results in the literature regarding the efficacy of these coolant flowrate parameters to scale the density ratio suggest other properties also play a role. Experiments were performed to measure η on a flat plate with a 7-7-7-shaped hole. Various coolant gases were used to give a large range of property variations. We show that a relatively new coolant flowrate parameter that accounts for density and specific heat, the advective capacity ratio, far exceeds the ability of either M or I to provide matched η between the various coolant gases that exhibit extreme property differences. With the specific heat of coolant in an engine significantly lower than that of the freestream, advective capacity ratio (ACR) is appropriate for scaling η with non-separating coolant flow.</abstract><cop>NEW YORK</cop><pub>ASME</pub><doi>10.1115/1.4046544</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0889-504X
ispartof Journal of turbomachinery, 2020-08, Vol.142 (8), Article 081010
issn 0889-504X
1528-8900
language eng
recordid cdi_webofscience_primary_000560394100010
source ASME Transactions Journals (Current); Web of Science - Science Citation Index Expanded - 2020<img src="https://exlibris-pub.s3.amazonaws.com/fromwos-v2.jpg" />; Alma/SFX Local Collection
subjects Engineering
Engineering, Mechanical
Science & Technology
Technology
title Scaling Flat-Plate, Low-Temperature Adiabatic Effectiveness Results Using the Advective Capacity Ratio
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T09%3A38%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-asme_webof&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Scaling%20Flat-Plate,%20Low-Temperature%20Adiabatic%20Effectiveness%20Results%20Using%20the%20Advective%20Capacity%20Ratio&rft.jtitle=Journal%20of%20turbomachinery&rft.au=Fischer,%20Jacob%20P&rft.date=2020-08-01&rft.volume=142&rft.issue=8&rft.artnum=081010&rft.issn=0889-504X&rft.eissn=1528-8900&rft_id=info:doi/10.1115/1.4046544&rft_dat=%3Casme_webof%3E1075074%3C/asme_webof%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true