A comparative analysis of a heat pump application with grey wastewater source for domestic hot water preparation in hotels
System for domestic hot water (DHW) preparation generally represents a considerable portion of the energy and water consumption in hotels worldwide. As a consequence, a vast amount of heat is wasted through the drainage system from rooms and kitchens. Also, for hotel-type buildings, demand for DHW c...
Gespeichert in:
Veröffentlicht in: | Journal of thermal analysis and calorimetry 2020-07, Vol.141 (1), p.559-572 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 572 |
---|---|
container_issue | 1 |
container_start_page | 559 |
container_title | Journal of thermal analysis and calorimetry |
container_volume | 141 |
creator | Todorovic, Danijel Tomic, Mladen Bojanic, Ranko Bajatovic, Dusan Andelkovic, Aleksandar S |
description | System for domestic hot water (DHW) preparation generally represents a considerable portion of the energy and water consumption in hotels worldwide. As a consequence, a vast amount of heat is wasted through the drainage system from rooms and kitchens. Also, for hotel-type buildings, demand for DHW can vary according to their occupancy. Researchers and practitioners have a very challenging task to select the optimal and most sustainable solution. This paper analyses a DHW heating system with a heat pump system that uses grey wastewater (GWW) and rainwater as an energy source. The application is developed in combination with experimental site measurements (real system operation) and required standards. The research deals with the subject system in bivalent operation (basic and advanced configuration of heat pump system assisted with gas boiler). In order to evaluate the application of the advanced heat pump DHW heating system with GWW source, a comprehensive assessment is done with a gas boiler system only (base case) and solar plate collector system. For the advanced heat pump system, the study has determined the two key operation elements: hotel occupancy rate and system regulation. The financial assessment showed very promising economic metrics (PBP = 6.54 years, POP = 7.9 years IRR = 9.40%, MIRR = 17.00%) compared to the base case. The study provided results of a sensitive cost-effective system assessment for periods with lower than average hotel occupancy rates. Also, when the total operation and investment costs are compared with the data calculated on an average annual hotel occupancy rate of 68%, the final conclusion is that the investment in the advanced heat pump system is justified only if its gas consumption share is less than 14.27%. The analysis confirmed the main advantages of this heat pump system which are lowered energy consumption and reduced total operating costs. |
doi_str_mv | 10.1007/s10973-020-09495-0 |
format | Article |
fullrecord | <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_journals_2412156206</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A626451491</galeid><sourcerecordid>A626451491</sourcerecordid><originalsourceid>FETCH-LOGICAL-c460t-c46d0080fe7a03afcb79f434ac5dba2dc0f52d35ac5918cb24455c0ac1214a333</originalsourceid><addsrcrecordid>eNp9kUuLFDEUhQtRcBz9A64CrlzUePOq7iybQceBgQEf63A7ddOdoapSJml72l9v2hJkNhJIbnK_k5xwmuYthysOsPqQOZiVbEFAC0YZ3cKz5oLr9boVRnTPay1r3XENL5tXOT8AgDHAL5pfG-biOGPCEn4SwwmHUw6ZRc-Q7QkLmw_jzHCeh-AqEyd2DGXPdolO7Ii50BELJZbjITliPibWx5FyCY7tY2FLd060PFHlYTo3aMivmxceh0xv_q6XzfdPH79df27v7m9urzd3rVMdlPPcA6zB0wpBonfblfFKKnS636LoHXgteqnr3vC12wqltHaAjguuUEp52bxb7p1T_HGo1uxDNVs_mq1QFdKdgK5SVwu1w4FsmHwsCV0dPY3BxYl8qOebTnRKc2V4Fbx_IqhMoceyw0PO9vbrl6esWFiXYs6JvJ1TGDGdLAd7DtAuAdoaoP0ToIUqkosoV3jaUfrn-z-q3xeAnxs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2412156206</pqid></control><display><type>article</type><title>A comparative analysis of a heat pump application with grey wastewater source for domestic hot water preparation in hotels</title><source>SpringerLink Journals - AutoHoldings</source><creator>Todorovic, Danijel ; Tomic, Mladen ; Bojanic, Ranko ; Bajatovic, Dusan ; Andelkovic, Aleksandar S</creator><creatorcontrib>Todorovic, Danijel ; Tomic, Mladen ; Bojanic, Ranko ; Bajatovic, Dusan ; Andelkovic, Aleksandar S</creatorcontrib><description>System for domestic hot water (DHW) preparation generally represents a considerable portion of the energy and water consumption in hotels worldwide. As a consequence, a vast amount of heat is wasted through the drainage system from rooms and kitchens. Also, for hotel-type buildings, demand for DHW can vary according to their occupancy. Researchers and practitioners have a very challenging task to select the optimal and most sustainable solution. This paper analyses a DHW heating system with a heat pump system that uses grey wastewater (GWW) and rainwater as an energy source. The application is developed in combination with experimental site measurements (real system operation) and required standards. The research deals with the subject system in bivalent operation (basic and advanced configuration of heat pump system assisted with gas boiler). In order to evaluate the application of the advanced heat pump DHW heating system with GWW source, a comprehensive assessment is done with a gas boiler system only (base case) and solar plate collector system. For the advanced heat pump system, the study has determined the two key operation elements: hotel occupancy rate and system regulation. The financial assessment showed very promising economic metrics (PBP = 6.54 years, POP = 7.9 years IRR = 9.40%, MIRR = 17.00%) compared to the base case. The study provided results of a sensitive cost-effective system assessment for periods with lower than average hotel occupancy rates. Also, when the total operation and investment costs are compared with the data calculated on an average annual hotel occupancy rate of 68%, the final conclusion is that the investment in the advanced heat pump system is justified only if its gas consumption share is less than 14.27%. The analysis confirmed the main advantages of this heat pump system which are lowered energy consumption and reduced total operating costs.</description><identifier>ISSN: 1388-6150</identifier><identifier>EISSN: 1588-2926</identifier><identifier>DOI: 10.1007/s10973-020-09495-0</identifier><language>eng</language><publisher>Cham: Springer International Publishing</publisher><subject>Analytical Chemistry ; Boiler plate ; Chemistry ; Chemistry and Materials Science ; Drainage systems ; Energy consumption ; Heat pumps ; Heat recovery systems ; Heating ; Hot water ; Hotels ; Hotels & motels ; Hotels and motels ; Inorganic Chemistry ; Investment ; Kitchens ; Measurement Science and Instrumentation ; Occupancy ; Operating costs ; Physical Chemistry ; Polymer Sciences ; Rain water ; Rain-water (Water-supply) ; Research agreements ; Wastewater ; Water consumption</subject><ispartof>Journal of thermal analysis and calorimetry, 2020-07, Vol.141 (1), p.559-572</ispartof><rights>Akadémiai Kiadó, Budapest, Hungary 2020</rights><rights>COPYRIGHT 2020 Springer</rights><rights>Akadémiai Kiadó, Budapest, Hungary 2020.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c460t-c46d0080fe7a03afcb79f434ac5dba2dc0f52d35ac5918cb24455c0ac1214a333</citedby><cites>FETCH-LOGICAL-c460t-c46d0080fe7a03afcb79f434ac5dba2dc0f52d35ac5918cb24455c0ac1214a333</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s10973-020-09495-0$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s10973-020-09495-0$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids></links><search><creatorcontrib>Todorovic, Danijel</creatorcontrib><creatorcontrib>Tomic, Mladen</creatorcontrib><creatorcontrib>Bojanic, Ranko</creatorcontrib><creatorcontrib>Bajatovic, Dusan</creatorcontrib><creatorcontrib>Andelkovic, Aleksandar S</creatorcontrib><title>A comparative analysis of a heat pump application with grey wastewater source for domestic hot water preparation in hotels</title><title>Journal of thermal analysis and calorimetry</title><addtitle>J Therm Anal Calorim</addtitle><description>System for domestic hot water (DHW) preparation generally represents a considerable portion of the energy and water consumption in hotels worldwide. As a consequence, a vast amount of heat is wasted through the drainage system from rooms and kitchens. Also, for hotel-type buildings, demand for DHW can vary according to their occupancy. Researchers and practitioners have a very challenging task to select the optimal and most sustainable solution. This paper analyses a DHW heating system with a heat pump system that uses grey wastewater (GWW) and rainwater as an energy source. The application is developed in combination with experimental site measurements (real system operation) and required standards. The research deals with the subject system in bivalent operation (basic and advanced configuration of heat pump system assisted with gas boiler). In order to evaluate the application of the advanced heat pump DHW heating system with GWW source, a comprehensive assessment is done with a gas boiler system only (base case) and solar plate collector system. For the advanced heat pump system, the study has determined the two key operation elements: hotel occupancy rate and system regulation. The financial assessment showed very promising economic metrics (PBP = 6.54 years, POP = 7.9 years IRR = 9.40%, MIRR = 17.00%) compared to the base case. The study provided results of a sensitive cost-effective system assessment for periods with lower than average hotel occupancy rates. Also, when the total operation and investment costs are compared with the data calculated on an average annual hotel occupancy rate of 68%, the final conclusion is that the investment in the advanced heat pump system is justified only if its gas consumption share is less than 14.27%. The analysis confirmed the main advantages of this heat pump system which are lowered energy consumption and reduced total operating costs.</description><subject>Analytical Chemistry</subject><subject>Boiler plate</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Drainage systems</subject><subject>Energy consumption</subject><subject>Heat pumps</subject><subject>Heat recovery systems</subject><subject>Heating</subject><subject>Hot water</subject><subject>Hotels</subject><subject>Hotels & motels</subject><subject>Hotels and motels</subject><subject>Inorganic Chemistry</subject><subject>Investment</subject><subject>Kitchens</subject><subject>Measurement Science and Instrumentation</subject><subject>Occupancy</subject><subject>Operating costs</subject><subject>Physical Chemistry</subject><subject>Polymer Sciences</subject><subject>Rain water</subject><subject>Rain-water (Water-supply)</subject><subject>Research agreements</subject><subject>Wastewater</subject><subject>Water consumption</subject><issn>1388-6150</issn><issn>1588-2926</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kUuLFDEUhQtRcBz9A64CrlzUePOq7iybQceBgQEf63A7ddOdoapSJml72l9v2hJkNhJIbnK_k5xwmuYthysOsPqQOZiVbEFAC0YZ3cKz5oLr9boVRnTPay1r3XENL5tXOT8AgDHAL5pfG-biOGPCEn4SwwmHUw6ZRc-Q7QkLmw_jzHCeh-AqEyd2DGXPdolO7Ii50BELJZbjITliPibWx5FyCY7tY2FLd060PFHlYTo3aMivmxceh0xv_q6XzfdPH79df27v7m9urzd3rVMdlPPcA6zB0wpBonfblfFKKnS636LoHXgteqnr3vC12wqltHaAjguuUEp52bxb7p1T_HGo1uxDNVs_mq1QFdKdgK5SVwu1w4FsmHwsCV0dPY3BxYl8qOebTnRKc2V4Fbx_IqhMoceyw0PO9vbrl6esWFiXYs6JvJ1TGDGdLAd7DtAuAdoaoP0ToIUqkosoV3jaUfrn-z-q3xeAnxs</recordid><startdate>20200701</startdate><enddate>20200701</enddate><creator>Todorovic, Danijel</creator><creator>Tomic, Mladen</creator><creator>Bojanic, Ranko</creator><creator>Bajatovic, Dusan</creator><creator>Andelkovic, Aleksandar S</creator><general>Springer International Publishing</general><general>Springer</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ISR</scope></search><sort><creationdate>20200701</creationdate><title>A comparative analysis of a heat pump application with grey wastewater source for domestic hot water preparation in hotels</title><author>Todorovic, Danijel ; Tomic, Mladen ; Bojanic, Ranko ; Bajatovic, Dusan ; Andelkovic, Aleksandar S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c460t-c46d0080fe7a03afcb79f434ac5dba2dc0f52d35ac5918cb24455c0ac1214a333</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Analytical Chemistry</topic><topic>Boiler plate</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Drainage systems</topic><topic>Energy consumption</topic><topic>Heat pumps</topic><topic>Heat recovery systems</topic><topic>Heating</topic><topic>Hot water</topic><topic>Hotels</topic><topic>Hotels & motels</topic><topic>Hotels and motels</topic><topic>Inorganic Chemistry</topic><topic>Investment</topic><topic>Kitchens</topic><topic>Measurement Science and Instrumentation</topic><topic>Occupancy</topic><topic>Operating costs</topic><topic>Physical Chemistry</topic><topic>Polymer Sciences</topic><topic>Rain water</topic><topic>Rain-water (Water-supply)</topic><topic>Research agreements</topic><topic>Wastewater</topic><topic>Water consumption</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Todorovic, Danijel</creatorcontrib><creatorcontrib>Tomic, Mladen</creatorcontrib><creatorcontrib>Bojanic, Ranko</creatorcontrib><creatorcontrib>Bajatovic, Dusan</creatorcontrib><creatorcontrib>Andelkovic, Aleksandar S</creatorcontrib><collection>CrossRef</collection><collection>Gale In Context: Science</collection><jtitle>Journal of thermal analysis and calorimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Todorovic, Danijel</au><au>Tomic, Mladen</au><au>Bojanic, Ranko</au><au>Bajatovic, Dusan</au><au>Andelkovic, Aleksandar S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A comparative analysis of a heat pump application with grey wastewater source for domestic hot water preparation in hotels</atitle><jtitle>Journal of thermal analysis and calorimetry</jtitle><stitle>J Therm Anal Calorim</stitle><date>2020-07-01</date><risdate>2020</risdate><volume>141</volume><issue>1</issue><spage>559</spage><epage>572</epage><pages>559-572</pages><issn>1388-6150</issn><eissn>1588-2926</eissn><abstract>System for domestic hot water (DHW) preparation generally represents a considerable portion of the energy and water consumption in hotels worldwide. As a consequence, a vast amount of heat is wasted through the drainage system from rooms and kitchens. Also, for hotel-type buildings, demand for DHW can vary according to their occupancy. Researchers and practitioners have a very challenging task to select the optimal and most sustainable solution. This paper analyses a DHW heating system with a heat pump system that uses grey wastewater (GWW) and rainwater as an energy source. The application is developed in combination with experimental site measurements (real system operation) and required standards. The research deals with the subject system in bivalent operation (basic and advanced configuration of heat pump system assisted with gas boiler). In order to evaluate the application of the advanced heat pump DHW heating system with GWW source, a comprehensive assessment is done with a gas boiler system only (base case) and solar plate collector system. For the advanced heat pump system, the study has determined the two key operation elements: hotel occupancy rate and system regulation. The financial assessment showed very promising economic metrics (PBP = 6.54 years, POP = 7.9 years IRR = 9.40%, MIRR = 17.00%) compared to the base case. The study provided results of a sensitive cost-effective system assessment for periods with lower than average hotel occupancy rates. Also, when the total operation and investment costs are compared with the data calculated on an average annual hotel occupancy rate of 68%, the final conclusion is that the investment in the advanced heat pump system is justified only if its gas consumption share is less than 14.27%. The analysis confirmed the main advantages of this heat pump system which are lowered energy consumption and reduced total operating costs.</abstract><cop>Cham</cop><pub>Springer International Publishing</pub><doi>10.1007/s10973-020-09495-0</doi><tpages>14</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1388-6150 |
ispartof | Journal of thermal analysis and calorimetry, 2020-07, Vol.141 (1), p.559-572 |
issn | 1388-6150 1588-2926 |
language | eng |
recordid | cdi_proquest_journals_2412156206 |
source | SpringerLink Journals - AutoHoldings |
subjects | Analytical Chemistry Boiler plate Chemistry Chemistry and Materials Science Drainage systems Energy consumption Heat pumps Heat recovery systems Heating Hot water Hotels Hotels & motels Hotels and motels Inorganic Chemistry Investment Kitchens Measurement Science and Instrumentation Occupancy Operating costs Physical Chemistry Polymer Sciences Rain water Rain-water (Water-supply) Research agreements Wastewater Water consumption |
title | A comparative analysis of a heat pump application with grey wastewater source for domestic hot water preparation in hotels |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T01%3A58%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20comparative%20analysis%20of%20a%20heat%20pump%20application%20with%20grey%20wastewater%20source%20for%20domestic%20hot%20water%20preparation%20in%20hotels&rft.jtitle=Journal%20of%20thermal%20analysis%20and%20calorimetry&rft.au=Todorovic,%20Danijel&rft.date=2020-07-01&rft.volume=141&rft.issue=1&rft.spage=559&rft.epage=572&rft.pages=559-572&rft.issn=1388-6150&rft.eissn=1588-2926&rft_id=info:doi/10.1007/s10973-020-09495-0&rft_dat=%3Cgale_proqu%3EA626451491%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2412156206&rft_id=info:pmid/&rft_galeid=A626451491&rfr_iscdi=true |