Effect of Resolution and Bit Depth on Inferior Alveolar Canal Visualization on Exported Mandibular Cone-Beam Computed Tomography Images

Cone-beam computed tomography (CBCT) is commonly requested before dental implant treatment for the anatomic assessment of the inferior alveolar canal (IAC) to prevent its neurovascular content from being traumatized. CBCT images can be saved in different types of resolutions and bit depths; these pa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of oral and maxillofacial surgery 2020-05, Vol.78 (5), p.731-737
Hauptverfasser: Pour, Daryoush Goodarzi, Sedaghati, Azin, Shamshiri, Ahmad Reza
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Cone-beam computed tomography (CBCT) is commonly requested before dental implant treatment for the anatomic assessment of the inferior alveolar canal (IAC) to prevent its neurovascular content from being traumatized. CBCT images can be saved in different types of resolutions and bit depths; these parameters may significantly affect the diagnostic accuracy of images. This study aimed to assess the effect of resolution and bit depth on IAC visualization on exported mandibular CBCT images. Forty-one mandibular CBCT images of differing image resolutions and voxel sizes (0.16, 0.32, and 0.48 mm) and differing bit depths (12 and 15) were exported from a software program as a single file. Two observers evaluated the cross-sectional images in terms of IAC visibility using a 3-point scale (good, moderate, and poor). Disagreements were resolved by including a third observer, and the highest agreement was recorded. Study interobserver agreement was acceptable (84.2%) for IAC observation. The percentage of IAC observation was from 84.1 to 100% with the 12- and 15-bit depths, with a constant image resolution of 0.16 and 0.32 mm, respectively. A significant difference (from 19.5 to 48.8%) was noted between the 2 bit depths in the percentage of good IAC visualization with a constant resolution of 0.48 mm. Reduction in the image resolution to 0.48 mm showed a significant difference (19.5 to 100%) between the 12- and 15-bit depths in good IAC visualization. Exporting the mandibular CBCT images with 0.32 mm of resolution and a 12-bit depth will produce good and moderate radiographic IAC observation with the benefit of a smaller file size.
ISSN:0278-2391
1531-5053
DOI:10.1016/j.joms.2019.12.022