Efficacy of Dichlorophenolindophenol (DCIP) as Screening Test for Hb E: Revisited
Hb E-beta thalassemia is a major public health problem in West Bengal, India and is the predominant symptom producing thalassemia in this part of the country. To search for an easy, reliable and cost effective screening method for HbE that can be used at the community level where more sophisticated...
Gespeichert in:
Veröffentlicht in: | Indian journal of hematology & blood transfusion 2020-07, Vol.36 (3), p.535-541 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 541 |
---|---|
container_issue | 3 |
container_start_page | 535 |
container_title | Indian journal of hematology & blood transfusion |
container_volume | 36 |
creator | Mandal, Prakas Kumar Nataraj, K. S. Baul, Shuvra Neel Ghosh, Malay Kumar Dolai, Tuphan Kanti |
description | Hb E-beta thalassemia is a major public health problem in West Bengal, India and is the predominant symptom producing thalassemia in this part of the country. To search for an easy, reliable and cost effective screening method for HbE that can be used at the community level where more sophisticated methods are not readily available. And the DCIP test was performed for the purpose. Blood samples of 425 asymptomatic family members from 80 diagnosed cases of HbE beta Thalassemia patients were tested for Hb, RBC indices, DCIP test, HPLC, and in discordant cases confirmed by DNA mutation analysis. The present study shows DCIP screening test to have a sensitivity, specificity, positive predictive value and negative predictive value of 96.39%, 97.43%, 96.39% and 97.43% respectively. It also shows a false positive rate and false negative rate in 2.56% and 4.6% cases respectively. The advantage with DCIP over HPLC is that it can be easily performed at the community level by a person with minimum technical skill, few samples (even a single sample) can be tested at time, at a low cost. |
doi_str_mv | 10.1007/s12288-019-01235-1 |
format | Article |
fullrecord | <record><control><sourceid>proquest_webof</sourceid><recordid>TN_cdi_webofscience_primary_000501167300001CitationCount</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2423061719</sourcerecordid><originalsourceid>FETCH-LOGICAL-c451t-bf5180184b9b82ddfc8b43a80a7dda386667dc620fec58261fb876f9a6b1dcdb3</originalsourceid><addsrcrecordid>eNqNkVtrFTEUhQdR7EX_gE8BXyoymp3JJBkfBJkebaHgrT6HTC7npMxJjslMpf--aedQ0QfxIWRDvrXYK6uqXgB-AxjztxkIEaLG0JVDmraGR9Uh7jitMaXd4_sZatpiclAd5XyFMYOGtk-rg4YwyinpDquvK-e8VvoGRYdOvd6MMcXdxoY4-mD2Ezo57c-_vEIqo-86WRt8WKNLmyfkYkJnA1q9Q9_stc9-suZZ9cSpMdvn-_u4-vFxddmf1RefP533Hy5qTVuY6sG1IDAIOnSDIMY4LQbaKIEVN0Y1gjHGjWYEO6tbQRi4QXDmOsUGMNoMzXH1fvHdzcPWGm3DlNQod8lvVbqRUXn550vwG7mO15KX9KLrisHJ3iDFn3NJI7c-azuOKtg4Z0koacqPcbhDX_6FXsU5hRKvUNABNJyzQpGF0inmnKx7WAawvGtMLo3J0pi8b0xCEYlF9MsO0WXtbdD2QYgxbjEA402ZMPR-UpOPoY9zmIr09f9LC90sdC5EWNv0O8M_1rsFdy-3sw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2419113776</pqid></control><display><type>article</type><title>Efficacy of Dichlorophenolindophenol (DCIP) as Screening Test for Hb E: Revisited</title><source>SpringerNature Journals</source><source>Web of Science - Science Citation Index Expanded - 2020<img src="https://exlibris-pub.s3.amazonaws.com/fromwos-v2.jpg" /></source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Mandal, Prakas Kumar ; Nataraj, K. S. ; Baul, Shuvra Neel ; Ghosh, Malay Kumar ; Dolai, Tuphan Kanti</creator><creatorcontrib>Mandal, Prakas Kumar ; Nataraj, K. S. ; Baul, Shuvra Neel ; Ghosh, Malay Kumar ; Dolai, Tuphan Kanti</creatorcontrib><description>Hb E-beta thalassemia is a major public health problem in West Bengal, India and is the predominant symptom producing thalassemia in this part of the country. To search for an easy, reliable and cost effective screening method for HbE that can be used at the community level where more sophisticated methods are not readily available. And the DCIP test was performed for the purpose. Blood samples of 425 asymptomatic family members from 80 diagnosed cases of HbE beta Thalassemia patients were tested for Hb, RBC indices, DCIP test, HPLC, and in discordant cases confirmed by DNA mutation analysis. The present study shows DCIP screening test to have a sensitivity, specificity, positive predictive value and negative predictive value of 96.39%, 97.43%, 96.39% and 97.43% respectively. It also shows a false positive rate and false negative rate in 2.56% and 4.6% cases respectively. The advantage with DCIP over HPLC is that it can be easily performed at the community level by a person with minimum technical skill, few samples (even a single sample) can be tested at time, at a low cost.</description><identifier>ISSN: 0971-4502</identifier><identifier>ISSN: 0974-0449</identifier><identifier>EISSN: 0974-0449</identifier><identifier>EISSN: 0971-4502</identifier><identifier>DOI: 10.1007/s12288-019-01235-1</identifier><identifier>PMID: 32647429</identifier><language>eng</language><publisher>New Delhi: Springer India</publisher><subject>Accuracy ; Blood diseases ; Blood Transfusion Medicine ; Chemical compounds ; Deoxyribonucleic acid ; DNA ; Hematology ; Hemoglobin ; Human Genetics ; Life Sciences & Biomedicine ; Medical screening ; Medicine ; Medicine & Public Health ; Mutation ; Oncology ; Original ; Original Article ; Science & Technology</subject><ispartof>Indian journal of hematology & blood transfusion, 2020-07, Vol.36 (3), p.535-541</ispartof><rights>Indian Society of Hematology and Blood Transfusion 2019</rights><rights>Indian Society of Hematology and Blood Transfusion 2019.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>true</woscitedreferencessubscribed><woscitedreferencescount>1</woscitedreferencescount><woscitedreferencesoriginalsourcerecordid>wos000501167300001</woscitedreferencesoriginalsourcerecordid><citedby>FETCH-LOGICAL-c451t-bf5180184b9b82ddfc8b43a80a7dda386667dc620fec58261fb876f9a6b1dcdb3</citedby><cites>FETCH-LOGICAL-c451t-bf5180184b9b82ddfc8b43a80a7dda386667dc620fec58261fb876f9a6b1dcdb3</cites><orcidid>0000-0002-9911-4985</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7326899/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7326899/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,315,728,781,785,886,27929,27930,28253,41493,42562,51324,53796,53798</link.rule.ids></links><search><creatorcontrib>Mandal, Prakas Kumar</creatorcontrib><creatorcontrib>Nataraj, K. S.</creatorcontrib><creatorcontrib>Baul, Shuvra Neel</creatorcontrib><creatorcontrib>Ghosh, Malay Kumar</creatorcontrib><creatorcontrib>Dolai, Tuphan Kanti</creatorcontrib><title>Efficacy of Dichlorophenolindophenol (DCIP) as Screening Test for Hb E: Revisited</title><title>Indian journal of hematology & blood transfusion</title><addtitle>Indian J Hematol Blood Transfus</addtitle><addtitle>INDIAN J HEMATOL BLO</addtitle><description>Hb E-beta thalassemia is a major public health problem in West Bengal, India and is the predominant symptom producing thalassemia in this part of the country. To search for an easy, reliable and cost effective screening method for HbE that can be used at the community level where more sophisticated methods are not readily available. And the DCIP test was performed for the purpose. Blood samples of 425 asymptomatic family members from 80 diagnosed cases of HbE beta Thalassemia patients were tested for Hb, RBC indices, DCIP test, HPLC, and in discordant cases confirmed by DNA mutation analysis. The present study shows DCIP screening test to have a sensitivity, specificity, positive predictive value and negative predictive value of 96.39%, 97.43%, 96.39% and 97.43% respectively. It also shows a false positive rate and false negative rate in 2.56% and 4.6% cases respectively. The advantage with DCIP over HPLC is that it can be easily performed at the community level by a person with minimum technical skill, few samples (even a single sample) can be tested at time, at a low cost.</description><subject>Accuracy</subject><subject>Blood diseases</subject><subject>Blood Transfusion Medicine</subject><subject>Chemical compounds</subject><subject>Deoxyribonucleic acid</subject><subject>DNA</subject><subject>Hematology</subject><subject>Hemoglobin</subject><subject>Human Genetics</subject><subject>Life Sciences & Biomedicine</subject><subject>Medical screening</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Mutation</subject><subject>Oncology</subject><subject>Original</subject><subject>Original Article</subject><subject>Science & Technology</subject><issn>0971-4502</issn><issn>0974-0449</issn><issn>0974-0449</issn><issn>0971-4502</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>AOWDO</sourceid><recordid>eNqNkVtrFTEUhQdR7EX_gE8BXyoymp3JJBkfBJkebaHgrT6HTC7npMxJjslMpf--aedQ0QfxIWRDvrXYK6uqXgB-AxjztxkIEaLG0JVDmraGR9Uh7jitMaXd4_sZatpiclAd5XyFMYOGtk-rg4YwyinpDquvK-e8VvoGRYdOvd6MMcXdxoY4-mD2Ezo57c-_vEIqo-86WRt8WKNLmyfkYkJnA1q9Q9_stc9-suZZ9cSpMdvn-_u4-vFxddmf1RefP533Hy5qTVuY6sG1IDAIOnSDIMY4LQbaKIEVN0Y1gjHGjWYEO6tbQRi4QXDmOsUGMNoMzXH1fvHdzcPWGm3DlNQod8lvVbqRUXn550vwG7mO15KX9KLrisHJ3iDFn3NJI7c-azuOKtg4Z0koacqPcbhDX_6FXsU5hRKvUNABNJyzQpGF0inmnKx7WAawvGtMLo3J0pi8b0xCEYlF9MsO0WXtbdD2QYgxbjEA402ZMPR-UpOPoY9zmIr09f9LC90sdC5EWNv0O8M_1rsFdy-3sw</recordid><startdate>20200701</startdate><enddate>20200701</enddate><creator>Mandal, Prakas Kumar</creator><creator>Nataraj, K. S.</creator><creator>Baul, Shuvra Neel</creator><creator>Ghosh, Malay Kumar</creator><creator>Dolai, Tuphan Kanti</creator><general>Springer India</general><general>Springer Nature</general><general>Springer Nature B.V</general><scope>AOWDO</scope><scope>BLEPL</scope><scope>DTL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-9911-4985</orcidid></search><sort><creationdate>20200701</creationdate><title>Efficacy of Dichlorophenolindophenol (DCIP) as Screening Test for Hb E: Revisited</title><author>Mandal, Prakas Kumar ; Nataraj, K. S. ; Baul, Shuvra Neel ; Ghosh, Malay Kumar ; Dolai, Tuphan Kanti</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c451t-bf5180184b9b82ddfc8b43a80a7dda386667dc620fec58261fb876f9a6b1dcdb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Accuracy</topic><topic>Blood diseases</topic><topic>Blood Transfusion Medicine</topic><topic>Chemical compounds</topic><topic>Deoxyribonucleic acid</topic><topic>DNA</topic><topic>Hematology</topic><topic>Hemoglobin</topic><topic>Human Genetics</topic><topic>Life Sciences & Biomedicine</topic><topic>Medical screening</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Mutation</topic><topic>Oncology</topic><topic>Original</topic><topic>Original Article</topic><topic>Science & Technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mandal, Prakas Kumar</creatorcontrib><creatorcontrib>Nataraj, K. S.</creatorcontrib><creatorcontrib>Baul, Shuvra Neel</creatorcontrib><creatorcontrib>Ghosh, Malay Kumar</creatorcontrib><creatorcontrib>Dolai, Tuphan Kanti</creatorcontrib><collection>Web of Science - Science Citation Index Expanded - 2020</collection><collection>Web of Science Core Collection</collection><collection>Science Citation Index Expanded</collection><collection>CrossRef</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Indian journal of hematology & blood transfusion</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mandal, Prakas Kumar</au><au>Nataraj, K. S.</au><au>Baul, Shuvra Neel</au><au>Ghosh, Malay Kumar</au><au>Dolai, Tuphan Kanti</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Efficacy of Dichlorophenolindophenol (DCIP) as Screening Test for Hb E: Revisited</atitle><jtitle>Indian journal of hematology & blood transfusion</jtitle><stitle>Indian J Hematol Blood Transfus</stitle><stitle>INDIAN J HEMATOL BLO</stitle><date>2020-07-01</date><risdate>2020</risdate><volume>36</volume><issue>3</issue><spage>535</spage><epage>541</epage><pages>535-541</pages><issn>0971-4502</issn><issn>0974-0449</issn><eissn>0974-0449</eissn><eissn>0971-4502</eissn><abstract>Hb E-beta thalassemia is a major public health problem in West Bengal, India and is the predominant symptom producing thalassemia in this part of the country. To search for an easy, reliable and cost effective screening method for HbE that can be used at the community level where more sophisticated methods are not readily available. And the DCIP test was performed for the purpose. Blood samples of 425 asymptomatic family members from 80 diagnosed cases of HbE beta Thalassemia patients were tested for Hb, RBC indices, DCIP test, HPLC, and in discordant cases confirmed by DNA mutation analysis. The present study shows DCIP screening test to have a sensitivity, specificity, positive predictive value and negative predictive value of 96.39%, 97.43%, 96.39% and 97.43% respectively. It also shows a false positive rate and false negative rate in 2.56% and 4.6% cases respectively. The advantage with DCIP over HPLC is that it can be easily performed at the community level by a person with minimum technical skill, few samples (even a single sample) can be tested at time, at a low cost.</abstract><cop>New Delhi</cop><pub>Springer India</pub><pmid>32647429</pmid><doi>10.1007/s12288-019-01235-1</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-9911-4985</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0971-4502 |
ispartof | Indian journal of hematology & blood transfusion, 2020-07, Vol.36 (3), p.535-541 |
issn | 0971-4502 0974-0449 0974-0449 0971-4502 |
language | eng |
recordid | cdi_webofscience_primary_000501167300001CitationCount |
source | SpringerNature Journals; Web of Science - Science Citation Index Expanded - 2020<img src="https://exlibris-pub.s3.amazonaws.com/fromwos-v2.jpg" />; EZB-FREE-00999 freely available EZB journals; PubMed Central |
subjects | Accuracy Blood diseases Blood Transfusion Medicine Chemical compounds Deoxyribonucleic acid DNA Hematology Hemoglobin Human Genetics Life Sciences & Biomedicine Medical screening Medicine Medicine & Public Health Mutation Oncology Original Original Article Science & Technology |
title | Efficacy of Dichlorophenolindophenol (DCIP) as Screening Test for Hb E: Revisited |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-16T08%3A01%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_webof&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Efficacy%20of%20Dichlorophenolindophenol%20(DCIP)%20as%20Screening%20Test%20for%20Hb%20E:%20Revisited&rft.jtitle=Indian%20journal%20of%20hematology%20&%20blood%20transfusion&rft.au=Mandal,%20Prakas%20Kumar&rft.date=2020-07-01&rft.volume=36&rft.issue=3&rft.spage=535&rft.epage=541&rft.pages=535-541&rft.issn=0971-4502&rft.eissn=0974-0449&rft_id=info:doi/10.1007/s12288-019-01235-1&rft_dat=%3Cproquest_webof%3E2423061719%3C/proquest_webof%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2419113776&rft_id=info:pmid/32647429&rfr_iscdi=true |