Simulation and Modeling of Common Mode EMI Noise in Planar Transformers

The transformer is the key circuit component of the common-mode noise current when an isolated converter is working.The high-frequency characteristics of the transformer have an important influence on the common-mode noise of the converter.Traditionally,the mea-surement method is used for transforme...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:中兴通讯技术(英文版) 2023, Vol.21 (3), p.105-116
Hauptverfasser: LI Wei, JI Jingkang, LIU Yuanlong, SUN Jiawei, LIN Subin
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 116
container_issue 3
container_start_page 105
container_title 中兴通讯技术(英文版)
container_volume 21
creator LI Wei
JI Jingkang
LIU Yuanlong
SUN Jiawei
LIN Subin
description The transformer is the key circuit component of the common-mode noise current when an isolated converter is working.The high-frequency characteristics of the transformer have an important influence on the common-mode noise of the converter.Traditionally,the mea-surement method is used for transformer modeling,and a single lumped device is used to establish the transformer model,which cannot be predicted in the transformer design stage.Based on the transformer common-mode noise transmission mechanism,this paper derives the transformer common-mode equivalent capacitance under ideal conditions.According to the principle of experimental measurement of the net-work analyzer,the electromagnetic field finite element simulation software three-dimensional(3D)modeling and simulation method is used to obtain the two-port parameters of the transformer,extract the high-frequency parameters of the transformer,and establish its electromagnetic compatibility equivalent circuit model.Finally,an experimental prototype is used to verify the correctness of the model by comparing the ex-perimental measurement results with the simulation prediction results.
doi_str_mv 10.12142/ZTECOM.202303014
format Article
fullrecord <record><control><sourceid>wanfang_jour</sourceid><recordid>TN_cdi_wanfang_journals_zxtxjs_e202303014</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><wanfj_id>zxtxjs_e202303014</wanfj_id><sourcerecordid>zxtxjs_e202303014</sourcerecordid><originalsourceid>FETCH-wanfang_journals_zxtxjs_e2023030143</originalsourceid><addsrcrecordid>eNqVjr0OgjAYRTtoIlEewO1bHcCWP3Em-DOgJjK5kBoKKYGvSQuR-PRqYtydTnLOHS4hS0Zd5rHAW9_yNDlnrkc9n_qUBRNisWjjOyGL4xmxjZF3Suk2isMgssj-Kruh5b1UCBxLyFQpWok1qAoS1XVv_VGQZkc4KWkESIRLy5FryDVHUyndCW0WZFrx1gj7yzlZ7dI8OTgPjhXHumjUoPFdiufYj40pxO-g_8_2BZygRck</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Simulation and Modeling of Common Mode EMI Noise in Planar Transformers</title><source>Alma/SFX Local Collection</source><creator>LI Wei ; JI Jingkang ; LIU Yuanlong ; SUN Jiawei ; LIN Subin</creator><creatorcontrib>LI Wei ; JI Jingkang ; LIU Yuanlong ; SUN Jiawei ; LIN Subin</creatorcontrib><description>The transformer is the key circuit component of the common-mode noise current when an isolated converter is working.The high-frequency characteristics of the transformer have an important influence on the common-mode noise of the converter.Traditionally,the mea-surement method is used for transformer modeling,and a single lumped device is used to establish the transformer model,which cannot be predicted in the transformer design stage.Based on the transformer common-mode noise transmission mechanism,this paper derives the transformer common-mode equivalent capacitance under ideal conditions.According to the principle of experimental measurement of the net-work analyzer,the electromagnetic field finite element simulation software three-dimensional(3D)modeling and simulation method is used to obtain the two-port parameters of the transformer,extract the high-frequency parameters of the transformer,and establish its electromagnetic compatibility equivalent circuit model.Finally,an experimental prototype is used to verify the correctness of the model by comparing the ex-perimental measurement results with the simulation prediction results.</description><identifier>ISSN: 1673-5188</identifier><identifier>DOI: 10.12142/ZTECOM.202303014</identifier><language>eng</language><publisher>ZTE Corporation,Shenzhen 518057,China%Fuzhou University,Fuzhou 350108,China</publisher><ispartof>中兴通讯技术(英文版), 2023, Vol.21 (3), p.105-116</ispartof><rights>Copyright © Wanfang Data Co. Ltd. All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://www.wanfangdata.com.cn/images/PeriodicalImages/zxtxjs-e/zxtxjs-e.jpg</thumbnail><link.rule.ids>314,780,784,4023,27922,27923,27924</link.rule.ids></links><search><creatorcontrib>LI Wei</creatorcontrib><creatorcontrib>JI Jingkang</creatorcontrib><creatorcontrib>LIU Yuanlong</creatorcontrib><creatorcontrib>SUN Jiawei</creatorcontrib><creatorcontrib>LIN Subin</creatorcontrib><title>Simulation and Modeling of Common Mode EMI Noise in Planar Transformers</title><title>中兴通讯技术(英文版)</title><description>The transformer is the key circuit component of the common-mode noise current when an isolated converter is working.The high-frequency characteristics of the transformer have an important influence on the common-mode noise of the converter.Traditionally,the mea-surement method is used for transformer modeling,and a single lumped device is used to establish the transformer model,which cannot be predicted in the transformer design stage.Based on the transformer common-mode noise transmission mechanism,this paper derives the transformer common-mode equivalent capacitance under ideal conditions.According to the principle of experimental measurement of the net-work analyzer,the electromagnetic field finite element simulation software three-dimensional(3D)modeling and simulation method is used to obtain the two-port parameters of the transformer,extract the high-frequency parameters of the transformer,and establish its electromagnetic compatibility equivalent circuit model.Finally,an experimental prototype is used to verify the correctness of the model by comparing the ex-perimental measurement results with the simulation prediction results.</description><issn>1673-5188</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNqVjr0OgjAYRTtoIlEewO1bHcCWP3Em-DOgJjK5kBoKKYGvSQuR-PRqYtydTnLOHS4hS0Zd5rHAW9_yNDlnrkc9n_qUBRNisWjjOyGL4xmxjZF3Suk2isMgssj-Kruh5b1UCBxLyFQpWok1qAoS1XVv_VGQZkc4KWkESIRLy5FryDVHUyndCW0WZFrx1gj7yzlZ7dI8OTgPjhXHumjUoPFdiufYj40pxO-g_8_2BZygRck</recordid><startdate>2023</startdate><enddate>2023</enddate><creator>LI Wei</creator><creator>JI Jingkang</creator><creator>LIU Yuanlong</creator><creator>SUN Jiawei</creator><creator>LIN Subin</creator><general>ZTE Corporation,Shenzhen 518057,China%Fuzhou University,Fuzhou 350108,China</general><scope>2B.</scope><scope>4A8</scope><scope>92I</scope><scope>93N</scope><scope>PSX</scope><scope>TCJ</scope></search><sort><creationdate>2023</creationdate><title>Simulation and Modeling of Common Mode EMI Noise in Planar Transformers</title><author>LI Wei ; JI Jingkang ; LIU Yuanlong ; SUN Jiawei ; LIN Subin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-wanfang_journals_zxtxjs_e2023030143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>LI Wei</creatorcontrib><creatorcontrib>JI Jingkang</creatorcontrib><creatorcontrib>LIU Yuanlong</creatorcontrib><creatorcontrib>SUN Jiawei</creatorcontrib><creatorcontrib>LIN Subin</creatorcontrib><collection>Wanfang Data Journals - Hong Kong</collection><collection>WANFANG Data Centre</collection><collection>Wanfang Data Journals</collection><collection>万方数据期刊 - 香港版</collection><collection>China Online Journals (COJ)</collection><collection>China Online Journals (COJ)</collection><jtitle>中兴通讯技术(英文版)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>LI Wei</au><au>JI Jingkang</au><au>LIU Yuanlong</au><au>SUN Jiawei</au><au>LIN Subin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simulation and Modeling of Common Mode EMI Noise in Planar Transformers</atitle><jtitle>中兴通讯技术(英文版)</jtitle><date>2023</date><risdate>2023</risdate><volume>21</volume><issue>3</issue><spage>105</spage><epage>116</epage><pages>105-116</pages><issn>1673-5188</issn><abstract>The transformer is the key circuit component of the common-mode noise current when an isolated converter is working.The high-frequency characteristics of the transformer have an important influence on the common-mode noise of the converter.Traditionally,the mea-surement method is used for transformer modeling,and a single lumped device is used to establish the transformer model,which cannot be predicted in the transformer design stage.Based on the transformer common-mode noise transmission mechanism,this paper derives the transformer common-mode equivalent capacitance under ideal conditions.According to the principle of experimental measurement of the net-work analyzer,the electromagnetic field finite element simulation software three-dimensional(3D)modeling and simulation method is used to obtain the two-port parameters of the transformer,extract the high-frequency parameters of the transformer,and establish its electromagnetic compatibility equivalent circuit model.Finally,an experimental prototype is used to verify the correctness of the model by comparing the ex-perimental measurement results with the simulation prediction results.</abstract><pub>ZTE Corporation,Shenzhen 518057,China%Fuzhou University,Fuzhou 350108,China</pub><doi>10.12142/ZTECOM.202303014</doi></addata></record>
fulltext fulltext
identifier ISSN: 1673-5188
ispartof 中兴通讯技术(英文版), 2023, Vol.21 (3), p.105-116
issn 1673-5188
language eng
recordid cdi_wanfang_journals_zxtxjs_e202303014
source Alma/SFX Local Collection
title Simulation and Modeling of Common Mode EMI Noise in Planar Transformers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T13%3A12%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wanfang_jour&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simulation%20and%20Modeling%20of%20Common%20Mode%20EMI%20Noise%20in%20Planar%20Transformers&rft.jtitle=%E4%B8%AD%E5%85%B4%E9%80%9A%E8%AE%AF%E6%8A%80%E6%9C%AF%EF%BC%88%E8%8B%B1%E6%96%87%E7%89%88%EF%BC%89&rft.au=LI%20Wei&rft.date=2023&rft.volume=21&rft.issue=3&rft.spage=105&rft.epage=116&rft.pages=105-116&rft.issn=1673-5188&rft_id=info:doi/10.12142/ZTECOM.202303014&rft_dat=%3Cwanfang_jour%3Ezxtxjs_e202303014%3C/wanfang_jour%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_wanfj_id=zxtxjs_e202303014&rfr_iscdi=true