A novel dynamic equivalence method for grid-connected wind farm
Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with w...
Gespeichert in:
Veröffentlicht in: | Journal of Zhejiang University. A. Science 2008-04, Vol.9 (4), p.558-563 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 563 |
---|---|
container_issue | 4 |
container_start_page | 558 |
container_title | Journal of Zhejiang University. A. Science |
container_volume | 9 |
creator | Qiao, Jia-geng Lu, Zong-xiang Min, Yong |
description | Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method. |
doi_str_mv | 10.1631/jzus.A071564 |
format | Article |
fullrecord | <record><control><sourceid>wanfang_jour_proqu</sourceid><recordid>TN_cdi_wanfang_journals_zjdxxb_e200804016</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>26903716</cqvip_id><wanfj_id>zjdxxb_e200804016</wanfj_id><sourcerecordid>zjdxxb_e200804016</sourcerecordid><originalsourceid>FETCH-LOGICAL-c365t-21fc6b2942424d1656b46f5719a6d1a46925cdf72bd3d6bd27fb1d92777a9a323</originalsourceid><addsrcrecordid>eNp1kEtLAzEUhYMoWKs7f8DgQhAczWOSdFZSii8ouFFwFzJ5tFNnkjbp9PXrTWnBldzFvVy-c-7lAHCN4ANiBD3Odl18GEKOKCtOQA8NGM4R5_Q0zYyTnDL6fQ4uYpxBSDlkvAeehpnzK9NkeutkW6vMLLp6JRvjlMlas5x6nVkfskmoda68c0Ytjc7WtUt7GdpLcGZlE83VsffB18vz5-gtH3-8vo-G41wRRpc5RlaxCpcFTqURo6wqmKUclZJpJAtWYqq05bjSRLNKY24rpEvMOZelJJj0wd3Bdy2dlW4iZr4LLl0Uu5nebCphMIQDWMAURB_cHth58IvOxKVo66hM00hnfBcFwZQghooE3h9AFXyMwVgxD3Urw1YgKPaJin2i4phowvMDHhPmJib8PfEPf3O0n3o3WSSJqKT6sXVjBGYlJDxpfgEjkYN1</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>32531614</pqid></control><display><type>article</type><title>A novel dynamic equivalence method for grid-connected wind farm</title><source>Springer Nature - Complete Springer Journals</source><source>Alma/SFX Local Collection</source><creator>Qiao, Jia-geng ; Lu, Zong-xiang ; Min, Yong</creator><creatorcontrib>Qiao, Jia-geng ; Lu, Zong-xiang ; Min, Yong</creatorcontrib><description>Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method.</description><identifier>ISSN: 1673-565X</identifier><identifier>EISSN: 1862-1775</identifier><identifier>DOI: 10.1631/jzus.A071564</identifier><language>eng</language><publisher>Hangzhou: Zhejiang University Press</publisher><subject>Civil Engineering ; Classical and Continuum Physics ; Engineering ; Industrial Chemistry/Chemical Engineering ; Mechanical Engineering ; 动力学 ; 感应器 ; 电力系统</subject><ispartof>Journal of Zhejiang University. A. Science, 2008-04, Vol.9 (4), p.558-563</ispartof><rights>Zhejiang University 2008</rights><rights>Copyright © Wanfang Data Co. Ltd. All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c365t-21fc6b2942424d1656b46f5719a6d1a46925cdf72bd3d6bd27fb1d92777a9a323</citedby><cites>FETCH-LOGICAL-c365t-21fc6b2942424d1656b46f5719a6d1a46925cdf72bd3d6bd27fb1d92777a9a323</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/88140X/88140X.jpg</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1631/jzus.A071564$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1631/jzus.A071564$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27915,27916,41479,42548,51310</link.rule.ids></links><search><creatorcontrib>Qiao, Jia-geng</creatorcontrib><creatorcontrib>Lu, Zong-xiang</creatorcontrib><creatorcontrib>Min, Yong</creatorcontrib><title>A novel dynamic equivalence method for grid-connected wind farm</title><title>Journal of Zhejiang University. A. Science</title><addtitle>J. Zhejiang Univ. Sci. A</addtitle><addtitle>Journal of Zhejiang University Science</addtitle><description>Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method.</description><subject>Civil Engineering</subject><subject>Classical and Continuum Physics</subject><subject>Engineering</subject><subject>Industrial Chemistry/Chemical Engineering</subject><subject>Mechanical Engineering</subject><subject>动力学</subject><subject>感应器</subject><subject>电力系统</subject><issn>1673-565X</issn><issn>1862-1775</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNp1kEtLAzEUhYMoWKs7f8DgQhAczWOSdFZSii8ouFFwFzJ5tFNnkjbp9PXrTWnBldzFvVy-c-7lAHCN4ANiBD3Odl18GEKOKCtOQA8NGM4R5_Q0zYyTnDL6fQ4uYpxBSDlkvAeehpnzK9NkeutkW6vMLLp6JRvjlMlas5x6nVkfskmoda68c0Ytjc7WtUt7GdpLcGZlE83VsffB18vz5-gtH3-8vo-G41wRRpc5RlaxCpcFTqURo6wqmKUclZJpJAtWYqq05bjSRLNKY24rpEvMOZelJJj0wd3Bdy2dlW4iZr4LLl0Uu5nebCphMIQDWMAURB_cHth58IvOxKVo66hM00hnfBcFwZQghooE3h9AFXyMwVgxD3Urw1YgKPaJin2i4phowvMDHhPmJib8PfEPf3O0n3o3WSSJqKT6sXVjBGYlJDxpfgEjkYN1</recordid><startdate>20080401</startdate><enddate>20080401</enddate><creator>Qiao, Jia-geng</creator><creator>Lu, Zong-xiang</creator><creator>Min, Yong</creator><general>Zhejiang University Press</general><general>State Key Laboratory of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China</general><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W92</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>2B.</scope><scope>4A8</scope><scope>92I</scope><scope>93N</scope><scope>PSX</scope><scope>TCJ</scope></search><sort><creationdate>20080401</creationdate><title>A novel dynamic equivalence method for grid-connected wind farm</title><author>Qiao, Jia-geng ; Lu, Zong-xiang ; Min, Yong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c365t-21fc6b2942424d1656b46f5719a6d1a46925cdf72bd3d6bd27fb1d92777a9a323</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Civil Engineering</topic><topic>Classical and Continuum Physics</topic><topic>Engineering</topic><topic>Industrial Chemistry/Chemical Engineering</topic><topic>Mechanical Engineering</topic><topic>动力学</topic><topic>感应器</topic><topic>电力系统</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Qiao, Jia-geng</creatorcontrib><creatorcontrib>Lu, Zong-xiang</creatorcontrib><creatorcontrib>Min, Yong</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-工程技术</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Wanfang Data Journals - Hong Kong</collection><collection>WANFANG Data Centre</collection><collection>Wanfang Data Journals</collection><collection>万方数据期刊 - 香港版</collection><collection>China Online Journals (COJ)</collection><collection>China Online Journals (COJ)</collection><jtitle>Journal of Zhejiang University. A. Science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Qiao, Jia-geng</au><au>Lu, Zong-xiang</au><au>Min, Yong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A novel dynamic equivalence method for grid-connected wind farm</atitle><jtitle>Journal of Zhejiang University. A. Science</jtitle><stitle>J. Zhejiang Univ. Sci. A</stitle><addtitle>Journal of Zhejiang University Science</addtitle><date>2008-04-01</date><risdate>2008</risdate><volume>9</volume><issue>4</issue><spage>558</spage><epage>563</epage><pages>558-563</pages><issn>1673-565X</issn><eissn>1862-1775</eissn><abstract>Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method.</abstract><cop>Hangzhou</cop><pub>Zhejiang University Press</pub><doi>10.1631/jzus.A071564</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1673-565X |
ispartof | Journal of Zhejiang University. A. Science, 2008-04, Vol.9 (4), p.558-563 |
issn | 1673-565X 1862-1775 |
language | eng |
recordid | cdi_wanfang_journals_zjdxxb_e200804016 |
source | Springer Nature - Complete Springer Journals; Alma/SFX Local Collection |
subjects | Civil Engineering Classical and Continuum Physics Engineering Industrial Chemistry/Chemical Engineering Mechanical Engineering 动力学 感应器 电力系统 |
title | A novel dynamic equivalence method for grid-connected wind farm |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T03%3A11%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wanfang_jour_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20novel%20dynamic%20equivalence%20method%20for%20grid-connected%20wind%20farm&rft.jtitle=Journal%20of%20Zhejiang%20University.%20A.%20Science&rft.au=Qiao,%20Jia-geng&rft.date=2008-04-01&rft.volume=9&rft.issue=4&rft.spage=558&rft.epage=563&rft.pages=558-563&rft.issn=1673-565X&rft.eissn=1862-1775&rft_id=info:doi/10.1631/jzus.A071564&rft_dat=%3Cwanfang_jour_proqu%3Ezjdxxb_e200804016%3C/wanfang_jour_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=32531614&rft_id=info:pmid/&rft_cqvip_id=26903716&rft_wanfj_id=zjdxxb_e200804016&rfr_iscdi=true |