Determining the boundaries of globular-to-spray transfer in robotic GMAW

Robotic gas metal arc welding (GMAW) experiments were conducted using an ERTOS-1 electrode with Ar + 10% CO2 shielding gas, and the welding current and arc voltage signals were collected by a data acquisition system. The boundaries between globular transfer and spray transfer in terms of the welding...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:China welding 2006-12, Vol.15 (4), p.75-78
1. Verfasser: 胥国祥 武传松 陈茂爱
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Robotic gas metal arc welding (GMAW) experiments were conducted using an ERTOS-1 electrode with Ar + 10% CO2 shielding gas, and the welding current and arc voltage signals were collected by a data acquisition system. The boundaries between globular transfer and spray transfer in terms of the welding current and arc voltage were determined according to the waveform of electric signals and the Fourier transform results of arc voltage. The optimum welding parameters for the two transfer modes were obtained, which laid a foundation for the numerical simulation and control of GMAW process.
ISSN:1004-5341