Preparation of Laminin-apatite-polymer Composites Using Metastable Calcium Phosphate Solutions
TB3; A synthetic polymer with a laminin-apatite composite layer on its surface would be useful as a percutaneous device. The preparation of such a composite was attempted in the present study using poly ( ethylene terephthalate ) (PET) and polyethylene ( PE ) as the synthetic polymer. PET and PE pla...
Gespeichert in:
Veröffentlicht in: | 武汉理工大学学报(材料科学版)英 2005-12, Vol.20 (z1), p.220-222 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 222 |
---|---|
container_issue | z1 |
container_start_page | 220 |
container_title | 武汉理工大学学报(材料科学版)英 |
container_volume | 20 |
creator | A Oyane M Kasahara N Ichinose Y Yokoyama M Uchida A Ito |
description | TB3; A synthetic polymer with a laminin-apatite composite layer on its surface would be useful as a percutaneous device. The preparation of such a composite was attempted in the present study using poly ( ethylene terephthalate ) (PET) and polyethylene ( PE ) as the synthetic polymer. PET and PE plates and those pretreated with an oxygen plasma were alternately dipped in calcium and phosphate ion solutions, and then immersed in a metastable ealcium phosphate solution supplemented with laminin ( LCP solution ). The PET and PE plates pretreated with an oxygen plasma formed a uniform and continuous layer of a laminin- apatite composite on their surfaces. In contrast, the PET and PE plates that had not been pretreated with an oxygen plasma did not form a continuous layer of a laminin-apatite composite on their surfaces. The hydrophilic functional groups on the PET and PE surfaces introduced by the plasma treatment were responsible for the successful laminin-apatite composite coating. |
format | Article |
fullrecord | <record><control><sourceid>wanfang_jour</sourceid><recordid>TN_cdi_wanfang_journals_whgydxxb_e2005z1071</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><wanfj_id>whgydxxb_e2005z1071</wanfj_id><sourcerecordid>whgydxxb_e2005z1071</sourcerecordid><originalsourceid>FETCH-LOGICAL-s1061-54894efc97732197a588512ebbfd27ca926ab565e902aee14ff26dc4c00b54eb3</originalsourceid><addsrcrecordid>eNotjctqhDAUQF200Om0_5B9EW5i4mNZpC-wzEA728qN3qiDJmKUmenX19KuDpzFOVfBhgNAKCSPboJb748AEqI43gRf-4lGnHDunGXOsAKHznY2xHFVM4Wj6y8DTSx3w-j8ajw7-M427J1m9DPqnliOfdUtA9u3zo8tzsQ-XL_8Fv1dcG2w93T_z21weH76zF_DYvfylj8WoecQ81DJNJNkqixJIsGzBFWaKi5Ia1OLpMJMxKhVrCgDgURcGiPiupIVgFaSdLQNHv66J7QGbVMe3TLZ9Vie2uZSn8-6JAGgvjkkPPoBbj9TyQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Preparation of Laminin-apatite-polymer Composites Using Metastable Calcium Phosphate Solutions</title><source>Springer Nature - Complete Springer Journals</source><source>Alma/SFX Local Collection</source><creator>A Oyane ; M Kasahara ; N Ichinose ; Y Yokoyama ; M Uchida ; A Ito</creator><creatorcontrib>A Oyane ; M Kasahara ; N Ichinose ; Y Yokoyama ; M Uchida ; A Ito</creatorcontrib><description>TB3; A synthetic polymer with a laminin-apatite composite layer on its surface would be useful as a percutaneous device. The preparation of such a composite was attempted in the present study using poly ( ethylene terephthalate ) (PET) and polyethylene ( PE ) as the synthetic polymer. PET and PE plates and those pretreated with an oxygen plasma were alternately dipped in calcium and phosphate ion solutions, and then immersed in a metastable ealcium phosphate solution supplemented with laminin ( LCP solution ). The PET and PE plates pretreated with an oxygen plasma formed a uniform and continuous layer of a laminin- apatite composite on their surfaces. In contrast, the PET and PE plates that had not been pretreated with an oxygen plasma did not form a continuous layer of a laminin-apatite composite on their surfaces. The hydrophilic functional groups on the PET and PE surfaces introduced by the plasma treatment were responsible for the successful laminin-apatite composite coating.</description><identifier>ISSN: 1000-2413</identifier><language>eng</language><publisher>Nanotechnology Research Institute,National Institute of Advanced Industrial Science and Technology (AIST),Central 5,1-1-1 Higashi,Tsukuba 305-8565,Japan%School of Science and Engineering,Waseda University,3-4-1 Okubo,Shinjuku 169-8555,Japan%Institute for Human Science and Biomedical Engineering,National Institute of Advanced Industrial Sdence aml Technology (AIST),Central 6,1-1-1 Higashi,Tsukuba 305-8566,Japan</publisher><ispartof>武汉理工大学学报(材料科学版)英, 2005-12, Vol.20 (z1), p.220-222</ispartof><rights>Copyright © Wanfang Data Co. Ltd. All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://www.wanfangdata.com.cn/images/PeriodicalImages/whgydxxb-e/whgydxxb-e.jpg</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>A Oyane</creatorcontrib><creatorcontrib>M Kasahara</creatorcontrib><creatorcontrib>N Ichinose</creatorcontrib><creatorcontrib>Y Yokoyama</creatorcontrib><creatorcontrib>M Uchida</creatorcontrib><creatorcontrib>A Ito</creatorcontrib><title>Preparation of Laminin-apatite-polymer Composites Using Metastable Calcium Phosphate Solutions</title><title>武汉理工大学学报(材料科学版)英</title><description>TB3; A synthetic polymer with a laminin-apatite composite layer on its surface would be useful as a percutaneous device. The preparation of such a composite was attempted in the present study using poly ( ethylene terephthalate ) (PET) and polyethylene ( PE ) as the synthetic polymer. PET and PE plates and those pretreated with an oxygen plasma were alternately dipped in calcium and phosphate ion solutions, and then immersed in a metastable ealcium phosphate solution supplemented with laminin ( LCP solution ). The PET and PE plates pretreated with an oxygen plasma formed a uniform and continuous layer of a laminin- apatite composite on their surfaces. In contrast, the PET and PE plates that had not been pretreated with an oxygen plasma did not form a continuous layer of a laminin-apatite composite on their surfaces. The hydrophilic functional groups on the PET and PE surfaces introduced by the plasma treatment were responsible for the successful laminin-apatite composite coating.</description><issn>1000-2413</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNotjctqhDAUQF200Om0_5B9EW5i4mNZpC-wzEA728qN3qiDJmKUmenX19KuDpzFOVfBhgNAKCSPboJb748AEqI43gRf-4lGnHDunGXOsAKHznY2xHFVM4Wj6y8DTSx3w-j8ajw7-M427J1m9DPqnliOfdUtA9u3zo8tzsQ-XL_8Fv1dcG2w93T_z21weH76zF_DYvfylj8WoecQ81DJNJNkqixJIsGzBFWaKi5Ia1OLpMJMxKhVrCgDgURcGiPiupIVgFaSdLQNHv66J7QGbVMe3TLZ9Vie2uZSn8-6JAGgvjkkPPoBbj9TyQ</recordid><startdate>200512</startdate><enddate>200512</enddate><creator>A Oyane</creator><creator>M Kasahara</creator><creator>N Ichinose</creator><creator>Y Yokoyama</creator><creator>M Uchida</creator><creator>A Ito</creator><general>Nanotechnology Research Institute,National Institute of Advanced Industrial Science and Technology (AIST),Central 5,1-1-1 Higashi,Tsukuba 305-8565,Japan%School of Science and Engineering,Waseda University,3-4-1 Okubo,Shinjuku 169-8555,Japan%Institute for Human Science and Biomedical Engineering,National Institute of Advanced Industrial Sdence aml Technology (AIST),Central 6,1-1-1 Higashi,Tsukuba 305-8566,Japan</general><scope>2B.</scope><scope>4A8</scope><scope>92I</scope><scope>93N</scope><scope>PSX</scope><scope>TCJ</scope></search><sort><creationdate>200512</creationdate><title>Preparation of Laminin-apatite-polymer Composites Using Metastable Calcium Phosphate Solutions</title><author>A Oyane ; M Kasahara ; N Ichinose ; Y Yokoyama ; M Uchida ; A Ito</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-s1061-54894efc97732197a588512ebbfd27ca926ab565e902aee14ff26dc4c00b54eb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>A Oyane</creatorcontrib><creatorcontrib>M Kasahara</creatorcontrib><creatorcontrib>N Ichinose</creatorcontrib><creatorcontrib>Y Yokoyama</creatorcontrib><creatorcontrib>M Uchida</creatorcontrib><creatorcontrib>A Ito</creatorcontrib><collection>Wanfang Data Journals - Hong Kong</collection><collection>WANFANG Data Centre</collection><collection>Wanfang Data Journals</collection><collection>万方数据期刊 - 香港版</collection><collection>China Online Journals (COJ)</collection><collection>China Online Journals (COJ)</collection><jtitle>武汉理工大学学报(材料科学版)英</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>A Oyane</au><au>M Kasahara</au><au>N Ichinose</au><au>Y Yokoyama</au><au>M Uchida</au><au>A Ito</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Preparation of Laminin-apatite-polymer Composites Using Metastable Calcium Phosphate Solutions</atitle><jtitle>武汉理工大学学报(材料科学版)英</jtitle><date>2005-12</date><risdate>2005</risdate><volume>20</volume><issue>z1</issue><spage>220</spage><epage>222</epage><pages>220-222</pages><issn>1000-2413</issn><abstract>TB3; A synthetic polymer with a laminin-apatite composite layer on its surface would be useful as a percutaneous device. The preparation of such a composite was attempted in the present study using poly ( ethylene terephthalate ) (PET) and polyethylene ( PE ) as the synthetic polymer. PET and PE plates and those pretreated with an oxygen plasma were alternately dipped in calcium and phosphate ion solutions, and then immersed in a metastable ealcium phosphate solution supplemented with laminin ( LCP solution ). The PET and PE plates pretreated with an oxygen plasma formed a uniform and continuous layer of a laminin- apatite composite on their surfaces. In contrast, the PET and PE plates that had not been pretreated with an oxygen plasma did not form a continuous layer of a laminin-apatite composite on their surfaces. The hydrophilic functional groups on the PET and PE surfaces introduced by the plasma treatment were responsible for the successful laminin-apatite composite coating.</abstract><pub>Nanotechnology Research Institute,National Institute of Advanced Industrial Science and Technology (AIST),Central 5,1-1-1 Higashi,Tsukuba 305-8565,Japan%School of Science and Engineering,Waseda University,3-4-1 Okubo,Shinjuku 169-8555,Japan%Institute for Human Science and Biomedical Engineering,National Institute of Advanced Industrial Sdence aml Technology (AIST),Central 6,1-1-1 Higashi,Tsukuba 305-8566,Japan</pub><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1000-2413 |
ispartof | 武汉理工大学学报(材料科学版)英, 2005-12, Vol.20 (z1), p.220-222 |
issn | 1000-2413 |
language | eng |
recordid | cdi_wanfang_journals_whgydxxb_e2005z1071 |
source | Springer Nature - Complete Springer Journals; Alma/SFX Local Collection |
title | Preparation of Laminin-apatite-polymer Composites Using Metastable Calcium Phosphate Solutions |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T09%3A58%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wanfang_jour&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Preparation%20of%20Laminin-apatite-polymer%20Composites%20Using%20Metastable%20Calcium%20Phosphate%20Solutions&rft.jtitle=%E6%AD%A6%E6%B1%89%E7%90%86%E5%B7%A5%E5%A4%A7%E5%AD%A6%E5%AD%A6%E6%8A%A5(%E6%9D%90%E6%96%99%E7%A7%91%E5%AD%A6%E7%89%88)%E8%8B%B1&rft.au=A%20Oyane&rft.date=2005-12&rft.volume=20&rft.issue=z1&rft.spage=220&rft.epage=222&rft.pages=220-222&rft.issn=1000-2413&rft_id=info:doi/&rft_dat=%3Cwanfang_jour%3Ewhgydxxb_e2005z1071%3C/wanfang_jour%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_wanfj_id=whgydxxb_e2005z1071&rfr_iscdi=true |