Application of Multislice Spiral CT for Guidance of Insertion of Thoracic Spine Pedicle Screws: An in vitro study

Summary: To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Huazhong University of Science and Technology. Medical sciences 2006, Vol.26 (4), p.485-488
1. Verfasser: 王娟 周义成 胡宁 王仁法
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 488
container_issue 4
container_start_page 485
container_title Journal of Huazhong University of Science and Technology. Medical sciences
container_volume 26
creator 王娟 周义成 胡宁 王仁法
description Summary: To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to guide the insertion of pedicle screws, After pulling the screws out, the pathways were filled with contrast media. The PW, PH, TSA and SSA of developed pathways were measured on the CT images and they were also measured on the real objects by caliper and goniometer, Analysis of variance demonstrated that the difference between the CT scans and real objects had no statistical significance (P〉0.05), Moreover, the difference between pedicle axis and developed pathway also had no statistical significance (P〉0.05), The data obtained from 3-D reconstruction of MSCT demonstrated that individualized standards, are not only accurate but also helpful for the successful placement ofpedicle screws.
doi_str_mv 10.1007/s11596-006-0429-3
format Article
fullrecord <record><control><sourceid>wanfang_jour_proqu</sourceid><recordid>TN_cdi_wanfang_journals_tjykdxxb_e200604029</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>22797333</cqvip_id><wanfj_id>tjykdxxb_e200604029</wanfj_id><sourcerecordid>tjykdxxb_e200604029</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2609-3838f0520fa2505e377ac725f6703afa0921183562d944d363bf91ece4d7f5af3</originalsourceid><addsrcrecordid>eNqFkdFuFCEUhonR2Fp9AG8M8cIbM3qAAYbLzUbbJjWauF4TloGW7SxMYcZ2X8Vn8Z36CrLZNV56QSAn3_8fzvkRek3gAwGQHwshXIkGoJ6WqoY9QadEKdYQxunT-haSNiAZO0EvStkAcClo-xydEEkoSC5OUVmM4xCsmUKKOHn8ZR6mUGrF4e9jyGbAyxX2KePzOfQm1nKFLmNx-a9idZOyscHu-ejwN9cHO1S1ze6-PP7-hRcRh4h_hiknXKa5371Ez7wZint1vM_Qj8-fVsuL5urr-eVycdVYKqBO07HOA6fgDeXAHZPSWEm5FxKY8QYUJaRjXNBetW3PBFt7RZx1bS89N56dofcH33sTvYnXepPmHGtHPW12t_3Dw1o7WpcHLVBV6XcHeszpbnZl0ttQrBsGE12aixZdXSfn5L8gUVypruUVJAfQ5lRKdl6POWxN3mkCeh-gPgSo6x_0PkDNqubN0Xxeb13_T3FMrAJvj6Y3KV7fhTrW2thbHwanKZWqps3YHykxocQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>19599845</pqid></control><display><type>article</type><title>Application of Multislice Spiral CT for Guidance of Insertion of Thoracic Spine Pedicle Screws: An in vitro study</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>王娟 周义成 胡宁 王仁法</creator><creatorcontrib>王娟 周义成 胡宁 王仁法</creatorcontrib><description>Summary: To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to guide the insertion of pedicle screws, After pulling the screws out, the pathways were filled with contrast media. The PW, PH, TSA and SSA of developed pathways were measured on the CT images and they were also measured on the real objects by caliper and goniometer, Analysis of variance demonstrated that the difference between the CT scans and real objects had no statistical significance (P〉0.05), Moreover, the difference between pedicle axis and developed pathway also had no statistical significance (P〉0.05), The data obtained from 3-D reconstruction of MSCT demonstrated that individualized standards, are not only accurate but also helpful for the successful placement ofpedicle screws.</description><identifier>ISSN: 1672-0733</identifier><identifier>EISSN: 1993-1352</identifier><identifier>DOI: 10.1007/s11596-006-0429-3</identifier><identifier>PMID: 17120756</identifier><language>eng</language><publisher>China: Department ofRadiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030,China</publisher><subject>Bone Screws ; Cadaver ; CT检查 ; Humans ; Imaging, Three-Dimensional ; Orthopedic Procedures - instrumentation ; Orthopedic Procedures - methods ; Thoracic Vertebrae - diagnostic imaging ; Thoracic Vertebrae - surgery ; Tomography, Spiral Computed - methods ; 肿瘤茎部 ; 胸脊柱</subject><ispartof>Journal of Huazhong University of Science and Technology. Medical sciences, 2006, Vol.26 (4), p.485-488</ispartof><rights>Copyright © Wanfang Data Co. Ltd. All Rights Reserved.</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2609-3838f0520fa2505e377ac725f6703afa0921183562d944d363bf91ece4d7f5af3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/85740A/85740A.jpg</thumbnail><link.rule.ids>314,776,780,4009,27902,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17120756$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>王娟 周义成 胡宁 王仁法</creatorcontrib><title>Application of Multislice Spiral CT for Guidance of Insertion of Thoracic Spine Pedicle Screws: An in vitro study</title><title>Journal of Huazhong University of Science and Technology. Medical sciences</title><addtitle>Journal of Zuazhong University of Science and Technology: Medical Edition</addtitle><description>Summary: To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to guide the insertion of pedicle screws, After pulling the screws out, the pathways were filled with contrast media. The PW, PH, TSA and SSA of developed pathways were measured on the CT images and they were also measured on the real objects by caliper and goniometer, Analysis of variance demonstrated that the difference between the CT scans and real objects had no statistical significance (P〉0.05), Moreover, the difference between pedicle axis and developed pathway also had no statistical significance (P〉0.05), The data obtained from 3-D reconstruction of MSCT demonstrated that individualized standards, are not only accurate but also helpful for the successful placement ofpedicle screws.</description><subject>Bone Screws</subject><subject>Cadaver</subject><subject>CT检查</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional</subject><subject>Orthopedic Procedures - instrumentation</subject><subject>Orthopedic Procedures - methods</subject><subject>Thoracic Vertebrae - diagnostic imaging</subject><subject>Thoracic Vertebrae - surgery</subject><subject>Tomography, Spiral Computed - methods</subject><subject>肿瘤茎部</subject><subject>胸脊柱</subject><issn>1672-0733</issn><issn>1993-1352</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkdFuFCEUhonR2Fp9AG8M8cIbM3qAAYbLzUbbJjWauF4TloGW7SxMYcZ2X8Vn8Z36CrLZNV56QSAn3_8fzvkRek3gAwGQHwshXIkGoJ6WqoY9QadEKdYQxunT-haSNiAZO0EvStkAcClo-xydEEkoSC5OUVmM4xCsmUKKOHn8ZR6mUGrF4e9jyGbAyxX2KePzOfQm1nKFLmNx-a9idZOyscHu-ejwN9cHO1S1ze6-PP7-hRcRh4h_hiknXKa5371Ez7wZint1vM_Qj8-fVsuL5urr-eVycdVYKqBO07HOA6fgDeXAHZPSWEm5FxKY8QYUJaRjXNBetW3PBFt7RZx1bS89N56dofcH33sTvYnXepPmHGtHPW12t_3Dw1o7WpcHLVBV6XcHeszpbnZl0ttQrBsGE12aixZdXSfn5L8gUVypruUVJAfQ5lRKdl6POWxN3mkCeh-gPgSo6x_0PkDNqubN0Xxeb13_T3FMrAJvj6Y3KV7fhTrW2thbHwanKZWqps3YHykxocQ</recordid><startdate>2006</startdate><enddate>2006</enddate><creator>王娟 周义成 胡宁 王仁法</creator><general>Department ofRadiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030,China</general><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W91</scope><scope>~WA</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope><scope>2B.</scope><scope>4A8</scope><scope>92I</scope><scope>93N</scope><scope>PSX</scope><scope>TCJ</scope></search><sort><creationdate>2006</creationdate><title>Application of Multislice Spiral CT for Guidance of Insertion of Thoracic Spine Pedicle Screws: An in vitro study</title><author>王娟 周义成 胡宁 王仁法</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2609-3838f0520fa2505e377ac725f6703afa0921183562d944d363bf91ece4d7f5af3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Bone Screws</topic><topic>Cadaver</topic><topic>CT检查</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional</topic><topic>Orthopedic Procedures - instrumentation</topic><topic>Orthopedic Procedures - methods</topic><topic>Thoracic Vertebrae - diagnostic imaging</topic><topic>Thoracic Vertebrae - surgery</topic><topic>Tomography, Spiral Computed - methods</topic><topic>肿瘤茎部</topic><topic>胸脊柱</topic><toplevel>online_resources</toplevel><creatorcontrib>王娟 周义成 胡宁 王仁法</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-医药卫生</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><collection>Wanfang Data Journals - Hong Kong</collection><collection>WANFANG Data Centre</collection><collection>Wanfang Data Journals</collection><collection>万方数据期刊 - 香港版</collection><collection>China Online Journals (COJ)</collection><collection>China Online Journals (COJ)</collection><jtitle>Journal of Huazhong University of Science and Technology. Medical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>王娟 周义成 胡宁 王仁法</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of Multislice Spiral CT for Guidance of Insertion of Thoracic Spine Pedicle Screws: An in vitro study</atitle><jtitle>Journal of Huazhong University of Science and Technology. Medical sciences</jtitle><addtitle>Journal of Zuazhong University of Science and Technology: Medical Edition</addtitle><date>2006</date><risdate>2006</risdate><volume>26</volume><issue>4</issue><spage>485</spage><epage>488</epage><pages>485-488</pages><issn>1672-0733</issn><eissn>1993-1352</eissn><abstract>Summary: To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to guide the insertion of pedicle screws, After pulling the screws out, the pathways were filled with contrast media. The PW, PH, TSA and SSA of developed pathways were measured on the CT images and they were also measured on the real objects by caliper and goniometer, Analysis of variance demonstrated that the difference between the CT scans and real objects had no statistical significance (P〉0.05), Moreover, the difference between pedicle axis and developed pathway also had no statistical significance (P〉0.05), The data obtained from 3-D reconstruction of MSCT demonstrated that individualized standards, are not only accurate but also helpful for the successful placement ofpedicle screws.</abstract><cop>China</cop><pub>Department ofRadiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030,China</pub><pmid>17120756</pmid><doi>10.1007/s11596-006-0429-3</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1672-0733
ispartof Journal of Huazhong University of Science and Technology. Medical sciences, 2006, Vol.26 (4), p.485-488
issn 1672-0733
1993-1352
language eng
recordid cdi_wanfang_journals_tjykdxxb_e200604029
source MEDLINE; Alma/SFX Local Collection
subjects Bone Screws
Cadaver
CT检查
Humans
Imaging, Three-Dimensional
Orthopedic Procedures - instrumentation
Orthopedic Procedures - methods
Thoracic Vertebrae - diagnostic imaging
Thoracic Vertebrae - surgery
Tomography, Spiral Computed - methods
肿瘤茎部
胸脊柱
title Application of Multislice Spiral CT for Guidance of Insertion of Thoracic Spine Pedicle Screws: An in vitro study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T10%3A31%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wanfang_jour_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%20Multislice%20Spiral%20CT%20for%20Guidance%20of%20Insertion%20of%20Thoracic%20Spine%20Pedicle%20Screws%EF%BC%9A%20An%20in%20vitro%20study&rft.jtitle=Journal%20of%20Huazhong%20University%20of%20Science%20and%20Technology.%20Medical%20sciences&rft.au=%E7%8E%8B%E5%A8%9F%20%E5%91%A8%E4%B9%89%E6%88%90%20%E8%83%A1%E5%AE%81%20%E7%8E%8B%E4%BB%81%E6%B3%95&rft.date=2006&rft.volume=26&rft.issue=4&rft.spage=485&rft.epage=488&rft.pages=485-488&rft.issn=1672-0733&rft.eissn=1993-1352&rft_id=info:doi/10.1007/s11596-006-0429-3&rft_dat=%3Cwanfang_jour_proqu%3Etjykdxxb_e200604029%3C/wanfang_jour_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=19599845&rft_id=info:pmid/17120756&rft_cqvip_id=22797333&rft_wanfj_id=tjykdxxb_e200604029&rfr_iscdi=true