Fire Risk Assessment of CBD in Binhai New Area of Tianjin
Central business district(CBD)construction is in rapid development phase at present, therefore, the firefighting work in CBD becomes an important issue for safety. In this paper, a fire risk assessment index system is established from the perspective of regional characteristics, possible sources and...
Gespeichert in:
Veröffentlicht in: | Transactions of Tianjin University 2015-12, Vol.21 (6), p.501-506 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 506 |
---|---|
container_issue | 6 |
container_start_page | 501 |
container_title | Transactions of Tianjin University |
container_volume | 21 |
creator | 闫凤英 张琦 |
description | Central business district(CBD)construction is in rapid development phase at present, therefore, the firefighting work in CBD becomes an important issue for safety. In this paper, a fire risk assessment index system is established from the perspective of regional characteristics, possible sources and factors which influence the occurrence of fire. Analytic hierarchy process(AHP)is used to obtain the weights of different indexes so as to reflect their effects on the final fire risk assessment. Then, the fire risk of CBD in Binhai New Area of Tianjin is assessed with the help of the proposed model and Arc GIS technique. Finally, the fire station layout is optimized based on the discrete location model, realizing the reasonable allocation of firefighting resources. According to the analysis, super high-rise buildings and underground spaces are main factors that cause high fire risk; furthermore, five firstlevel fire stations can satisfy the requirement of rescue response time. |
doi_str_mv | 10.1007/s12209-015-2629-z |
format | Article |
fullrecord | <record><control><sourceid>wanfang_jour_cross</sourceid><recordid>TN_cdi_wanfang_journals_tianjdxxb_e201506004</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>667189044</cqvip_id><wanfj_id>tianjdxxb_e201506004</wanfj_id><sourcerecordid>tianjdxxb_e201506004</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2674-e80561d70a501dcf3f1e1fc974797d395ea1ebaf1093114f4f70262ac67583203</originalsourceid><addsrcrecordid>eNp9kEFPAjEQhRujiYj-AG8bz1Znut12ewQUNSGaGDw3ZbeFohTdakB-vd0s0ZunTtL3zZv3CDlHuEIAeR2RMVAUsKBMMEV3B6SHShW0RCUO0wwgKFclOyYnMS4BuAKJPaLGvrHZs4-v2SBGG-PKhs9s7bLR8CbzIRv6sDA-e7SbbNBY0_5MvQlLH07JkTNv0Z7t3z55Gd9OR_d08nT3MBpMaMWE5NSWUAisJZgCsK5c7tCiq5TkUsk6V4U1aGfGIagckTvuJKQEphKyKHMGeZ9cdns3JjgT5nq5_mpCctSf7SH1djvTlqXgIFKqJMdOXjXrGBvr9HvjV6b51gi6rUp3VelE6LYqvUsM65iYtGFumz-P_6CLvdFiHeYfift1EkJiqYDz_AdILHTa</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Fire Risk Assessment of CBD in Binhai New Area of Tianjin</title><source>Springer Nature - Complete Springer Journals</source><source>Alma/SFX Local Collection</source><creator>闫凤英 张琦</creator><creatorcontrib>闫凤英 张琦</creatorcontrib><description>Central business district(CBD)construction is in rapid development phase at present, therefore, the firefighting work in CBD becomes an important issue for safety. In this paper, a fire risk assessment index system is established from the perspective of regional characteristics, possible sources and factors which influence the occurrence of fire. Analytic hierarchy process(AHP)is used to obtain the weights of different indexes so as to reflect their effects on the final fire risk assessment. Then, the fire risk of CBD in Binhai New Area of Tianjin is assessed with the help of the proposed model and Arc GIS technique. Finally, the fire station layout is optimized based on the discrete location model, realizing the reasonable allocation of firefighting resources. According to the analysis, super high-rise buildings and underground spaces are main factors that cause high fire risk; furthermore, five firstlevel fire stations can satisfy the requirement of rescue response time.</description><identifier>ISSN: 1006-4982</identifier><identifier>EISSN: 1995-8196</identifier><identifier>DOI: 10.1007/s12209-015-2629-z</identifier><language>eng</language><publisher>Tianjin: Tianjin University</publisher><subject>Engineering ; Humanities and Social Sciences ; Mechanical Engineering ; multidisciplinary ; Science ; 下线 ; 服务 ; 迁移</subject><ispartof>Transactions of Tianjin University, 2015-12, Vol.21 (6), p.501-506</ispartof><rights>Tianjin University and Springer-Verlag Berlin Heidelberg 2015</rights><rights>Copyright © Wanfang Data Co. Ltd. All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2674-e80561d70a501dcf3f1e1fc974797d395ea1ebaf1093114f4f70262ac67583203</citedby><cites>FETCH-LOGICAL-c2674-e80561d70a501dcf3f1e1fc974797d395ea1ebaf1093114f4f70262ac67583203</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/85460X/85460X.jpg</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s12209-015-2629-z$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s12209-015-2629-z$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,777,781,27905,27906,41469,42538,51300</link.rule.ids></links><search><creatorcontrib>闫凤英 张琦</creatorcontrib><title>Fire Risk Assessment of CBD in Binhai New Area of Tianjin</title><title>Transactions of Tianjin University</title><addtitle>Trans. Tianjin Univ</addtitle><addtitle>Transactions of Tianjin University</addtitle><description>Central business district(CBD)construction is in rapid development phase at present, therefore, the firefighting work in CBD becomes an important issue for safety. In this paper, a fire risk assessment index system is established from the perspective of regional characteristics, possible sources and factors which influence the occurrence of fire. Analytic hierarchy process(AHP)is used to obtain the weights of different indexes so as to reflect their effects on the final fire risk assessment. Then, the fire risk of CBD in Binhai New Area of Tianjin is assessed with the help of the proposed model and Arc GIS technique. Finally, the fire station layout is optimized based on the discrete location model, realizing the reasonable allocation of firefighting resources. According to the analysis, super high-rise buildings and underground spaces are main factors that cause high fire risk; furthermore, five firstlevel fire stations can satisfy the requirement of rescue response time.</description><subject>Engineering</subject><subject>Humanities and Social Sciences</subject><subject>Mechanical Engineering</subject><subject>multidisciplinary</subject><subject>Science</subject><subject>下线</subject><subject>服务</subject><subject>迁移</subject><issn>1006-4982</issn><issn>1995-8196</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9kEFPAjEQhRujiYj-AG8bz1Znut12ewQUNSGaGDw3ZbeFohTdakB-vd0s0ZunTtL3zZv3CDlHuEIAeR2RMVAUsKBMMEV3B6SHShW0RCUO0wwgKFclOyYnMS4BuAKJPaLGvrHZs4-v2SBGG-PKhs9s7bLR8CbzIRv6sDA-e7SbbNBY0_5MvQlLH07JkTNv0Z7t3z55Gd9OR_d08nT3MBpMaMWE5NSWUAisJZgCsK5c7tCiq5TkUsk6V4U1aGfGIagckTvuJKQEphKyKHMGeZ9cdns3JjgT5nq5_mpCctSf7SH1djvTlqXgIFKqJMdOXjXrGBvr9HvjV6b51gi6rUp3VelE6LYqvUsM65iYtGFumz-P_6CLvdFiHeYfift1EkJiqYDz_AdILHTa</recordid><startdate>20151201</startdate><enddate>20151201</enddate><creator>闫凤英 张琦</creator><general>Tianjin University</general><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>2B.</scope><scope>4A8</scope><scope>92I</scope><scope>93N</scope><scope>PSX</scope><scope>TCJ</scope></search><sort><creationdate>20151201</creationdate><title>Fire Risk Assessment of CBD in Binhai New Area of Tianjin</title><author>闫凤英 张琦</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2674-e80561d70a501dcf3f1e1fc974797d395ea1ebaf1093114f4f70262ac67583203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Engineering</topic><topic>Humanities and Social Sciences</topic><topic>Mechanical Engineering</topic><topic>multidisciplinary</topic><topic>Science</topic><topic>下线</topic><topic>服务</topic><topic>迁移</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>闫凤英 张琦</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Wanfang Data Journals - Hong Kong</collection><collection>WANFANG Data Centre</collection><collection>Wanfang Data Journals</collection><collection>万方数据期刊 - 香港版</collection><collection>China Online Journals (COJ)</collection><collection>China Online Journals (COJ)</collection><jtitle>Transactions of Tianjin University</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>闫凤英 张琦</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fire Risk Assessment of CBD in Binhai New Area of Tianjin</atitle><jtitle>Transactions of Tianjin University</jtitle><stitle>Trans. Tianjin Univ</stitle><addtitle>Transactions of Tianjin University</addtitle><date>2015-12-01</date><risdate>2015</risdate><volume>21</volume><issue>6</issue><spage>501</spage><epage>506</epage><pages>501-506</pages><issn>1006-4982</issn><eissn>1995-8196</eissn><abstract>Central business district(CBD)construction is in rapid development phase at present, therefore, the firefighting work in CBD becomes an important issue for safety. In this paper, a fire risk assessment index system is established from the perspective of regional characteristics, possible sources and factors which influence the occurrence of fire. Analytic hierarchy process(AHP)is used to obtain the weights of different indexes so as to reflect their effects on the final fire risk assessment. Then, the fire risk of CBD in Binhai New Area of Tianjin is assessed with the help of the proposed model and Arc GIS technique. Finally, the fire station layout is optimized based on the discrete location model, realizing the reasonable allocation of firefighting resources. According to the analysis, super high-rise buildings and underground spaces are main factors that cause high fire risk; furthermore, five firstlevel fire stations can satisfy the requirement of rescue response time.</abstract><cop>Tianjin</cop><pub>Tianjin University</pub><doi>10.1007/s12209-015-2629-z</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1006-4982 |
ispartof | Transactions of Tianjin University, 2015-12, Vol.21 (6), p.501-506 |
issn | 1006-4982 1995-8196 |
language | eng |
recordid | cdi_wanfang_journals_tianjdxxb_e201506004 |
source | Springer Nature - Complete Springer Journals; Alma/SFX Local Collection |
subjects | Engineering Humanities and Social Sciences Mechanical Engineering multidisciplinary Science 下线 服务 迁移 |
title | Fire Risk Assessment of CBD in Binhai New Area of Tianjin |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T13%3A30%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wanfang_jour_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fire%20Risk%20Assessment%20of%20CBD%20in%20Binhai%20New%20Area%20of%20Tianjin&rft.jtitle=Transactions%20of%20Tianjin%20University&rft.au=%E9%97%AB%E5%87%A4%E8%8B%B1%20%E5%BC%A0%E7%90%A6&rft.date=2015-12-01&rft.volume=21&rft.issue=6&rft.spage=501&rft.epage=506&rft.pages=501-506&rft.issn=1006-4982&rft.eissn=1995-8196&rft_id=info:doi/10.1007/s12209-015-2629-z&rft_dat=%3Cwanfang_jour_cross%3Etianjdxxb_e201506004%3C/wanfang_jour_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_cqvip_id=667189044&rft_wanfj_id=tianjdxxb_e201506004&rfr_iscdi=true |