Micro Flow-Through Thermocycler with Simple Meandering Channel with Symmetric Temperature Zones for Disposable PCR-Devices in Microscope Slide Format

Chip-based flow-through PCR implements the PCR as a continuous process for nucleic acid analytics. The sample is transported in a winding channel through temperature zones required for denaturation, annealing and extension. Main fields of application are the monitoring of continuous processes for ra...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of bionics engineering 2008-12, Vol.5 (4), p.291-298
Hauptverfasser: Reichert, Anett, Felbel, Jana, Kielpinski, Mark, Urban, Matthias, Steinbrecht, Benno, Henkel, Thomas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 298
container_issue 4
container_start_page 291
container_title Journal of bionics engineering
container_volume 5
creator Reichert, Anett
Felbel, Jana
Kielpinski, Mark
Urban, Matthias
Steinbrecht, Benno
Henkel, Thomas
description Chip-based flow-through PCR implements the PCR as a continuous process for nucleic acid analytics. The sample is transported in a winding channel through temperature zones required for denaturation, annealing and extension. Main fields of application are the monitoring of continuous processes for rapid identification of contaminants and quality control as well as high throughput screening of cells or microorganisms. A modular arrangement with five heating zones for flow-through PCR is discussed and evaluated. The special heater arrangement allows the implementation of up to 40 cycles on the footprint of a microscope slide, which is placed on top of a 5 zones heating plate. Liquid/liquid two phase flow of PCR reaction mixture and mineral oil have been applied to create a segmented flow process scheme. In that way, the developed system may provide flow-through PCR as a unit operation for the droplet based microfluidics platform. The single use of disposable devices is commonly preferred due to the sensitivity of the PCR process to contaminations. All-glass microfluidic chips and disposable chip devices, made from polycarbonate as a replication with identically geometry, have been fabricated and tested. For the first time, microchannel geometries with nearly circular profile developed by all-glass technology have been transferred to mass fabrication by injection compression molding. Both devices have been successfully applied for the detection of the tumor suppressor gene p53. Although product yield and selectivity of the amplification process do not depend on the chip material, a well defined, reliable segmented flow regime could only be realized in the all-glass chip.
doi_str_mv 10.1016/S1672-6529(08)60173-0
format Article
fullrecord <record><control><sourceid>wanfang_jour_proqu</sourceid><recordid>TN_cdi_wanfang_journals_fsgcxb_e200804004</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><wanfj_id>fsgcxb_e200804004</wanfj_id><els_id>S1672652908601730</els_id><sourcerecordid>fsgcxb_e200804004</sourcerecordid><originalsourceid>FETCH-LOGICAL-c452t-2318c42334afee5ab420552c39adc8d05d48111542368afbb9365dfaa226b77e3</originalsourceid><addsrcrecordid>eNqFkc2O0zAURiMEEmXgEZC8Qswiw_Vfkq4Q6kwZpBmBaNmwsRznpvEosYOdTOmD8L6kzQiWXXlxz_mudb8keUvhigLNPmxolrM0k2z5HorLDGjOU3iWLJgUPGVU0OfJ4h_yMnkV4wOAXLKCL5I_99YET9at36fbJvhx15Btg6Hz5mBaDGRvh4ZsbNe3SO5RuwqDdTuyarRz2D6ND12HQ7CGbLHrMehhDEh-eoeR1D6Qaxt7H3U5RXxbfU-v8dGaaWQdOW2PxvdINq2tkKx96PTwOnlR6zbim6f3IvmxvtmubtO7r5-_rD7dpUZINqSM08IIxrnQNaLUpWAgJTN8qStTVCArUVBK5YRkha7LcskzWdVaM5aVeY78Irmcc_fa1drt1IMfg5s2qjruzO9SIQMoQACIiX03s33wv0aMg-psNNi22qEfo-I8l4xKdhZkICQwISdQzuDxBjFgrfpgOx0OioI6NqtOzapjbQoKdWpWweRlsxf7YxcY_n_7nPhxFnG66aOdxGgsOoOVDWgGVXl7JuEvjgK84A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20450245</pqid></control><display><type>article</type><title>Micro Flow-Through Thermocycler with Simple Meandering Channel with Symmetric Temperature Zones for Disposable PCR-Devices in Microscope Slide Format</title><source>Access via ScienceDirect (Elsevier)</source><source>Alma/SFX Local Collection</source><source>SpringerLink Journals - AutoHoldings</source><creator>Reichert, Anett ; Felbel, Jana ; Kielpinski, Mark ; Urban, Matthias ; Steinbrecht, Benno ; Henkel, Thomas</creator><creatorcontrib>Reichert, Anett ; Felbel, Jana ; Kielpinski, Mark ; Urban, Matthias ; Steinbrecht, Benno ; Henkel, Thomas</creatorcontrib><description>Chip-based flow-through PCR implements the PCR as a continuous process for nucleic acid analytics. The sample is transported in a winding channel through temperature zones required for denaturation, annealing and extension. Main fields of application are the monitoring of continuous processes for rapid identification of contaminants and quality control as well as high throughput screening of cells or microorganisms. A modular arrangement with five heating zones for flow-through PCR is discussed and evaluated. The special heater arrangement allows the implementation of up to 40 cycles on the footprint of a microscope slide, which is placed on top of a 5 zones heating plate. Liquid/liquid two phase flow of PCR reaction mixture and mineral oil have been applied to create a segmented flow process scheme. In that way, the developed system may provide flow-through PCR as a unit operation for the droplet based microfluidics platform. The single use of disposable devices is commonly preferred due to the sensitivity of the PCR process to contaminations. All-glass microfluidic chips and disposable chip devices, made from polycarbonate as a replication with identically geometry, have been fabricated and tested. For the first time, microchannel geometries with nearly circular profile developed by all-glass technology have been transferred to mass fabrication by injection compression molding. Both devices have been successfully applied for the detection of the tumor suppressor gene p53. Although product yield and selectivity of the amplification process do not depend on the chip material, a well defined, reliable segmented flow regime could only be realized in the all-glass chip.</description><identifier>ISSN: 1672-6529</identifier><identifier>EISSN: 2543-2141</identifier><identifier>DOI: 10.1016/S1672-6529(08)60173-0</identifier><language>eng</language><publisher>Singapore: Elsevier Ltd</publisher><subject>Artificial Intelligence ; Biochemical Engineering ; Bioinformatics ; Biomaterials ; biomedical ; Biomedical Engineering and Bioengineering ; Biomedical Engineering/Biotechnology ; Engineering ; injection molding ; lab-on-a-chip ; microfluidics ; PCR ; point-of-care ; two-phase-flow</subject><ispartof>Journal of bionics engineering, 2008-12, Vol.5 (4), p.291-298</ispartof><rights>2008 Jilin University</rights><rights>Jilin University 2008</rights><rights>Copyright © Wanfang Data Co. Ltd. All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c452t-2318c42334afee5ab420552c39adc8d05d48111542368afbb9365dfaa226b77e3</citedby><cites>FETCH-LOGICAL-c452t-2318c42334afee5ab420552c39adc8d05d48111542368afbb9365dfaa226b77e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://www.wanfangdata.com.cn/images/PeriodicalImages/fsgcxb-e/fsgcxb-e.jpg</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1016/S1672-6529(08)60173-0$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://dx.doi.org/10.1016/S1672-6529(08)60173-0$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,41488,42557,45995,51319</link.rule.ids></links><search><creatorcontrib>Reichert, Anett</creatorcontrib><creatorcontrib>Felbel, Jana</creatorcontrib><creatorcontrib>Kielpinski, Mark</creatorcontrib><creatorcontrib>Urban, Matthias</creatorcontrib><creatorcontrib>Steinbrecht, Benno</creatorcontrib><creatorcontrib>Henkel, Thomas</creatorcontrib><title>Micro Flow-Through Thermocycler with Simple Meandering Channel with Symmetric Temperature Zones for Disposable PCR-Devices in Microscope Slide Format</title><title>Journal of bionics engineering</title><addtitle>J Bionic Eng</addtitle><description>Chip-based flow-through PCR implements the PCR as a continuous process for nucleic acid analytics. The sample is transported in a winding channel through temperature zones required for denaturation, annealing and extension. Main fields of application are the monitoring of continuous processes for rapid identification of contaminants and quality control as well as high throughput screening of cells or microorganisms. A modular arrangement with five heating zones for flow-through PCR is discussed and evaluated. The special heater arrangement allows the implementation of up to 40 cycles on the footprint of a microscope slide, which is placed on top of a 5 zones heating plate. Liquid/liquid two phase flow of PCR reaction mixture and mineral oil have been applied to create a segmented flow process scheme. In that way, the developed system may provide flow-through PCR as a unit operation for the droplet based microfluidics platform. The single use of disposable devices is commonly preferred due to the sensitivity of the PCR process to contaminations. All-glass microfluidic chips and disposable chip devices, made from polycarbonate as a replication with identically geometry, have been fabricated and tested. For the first time, microchannel geometries with nearly circular profile developed by all-glass technology have been transferred to mass fabrication by injection compression molding. Both devices have been successfully applied for the detection of the tumor suppressor gene p53. Although product yield and selectivity of the amplification process do not depend on the chip material, a well defined, reliable segmented flow regime could only be realized in the all-glass chip.</description><subject>Artificial Intelligence</subject><subject>Biochemical Engineering</subject><subject>Bioinformatics</subject><subject>Biomaterials</subject><subject>biomedical</subject><subject>Biomedical Engineering and Bioengineering</subject><subject>Biomedical Engineering/Biotechnology</subject><subject>Engineering</subject><subject>injection molding</subject><subject>lab-on-a-chip</subject><subject>microfluidics</subject><subject>PCR</subject><subject>point-of-care</subject><subject>two-phase-flow</subject><issn>1672-6529</issn><issn>2543-2141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqFkc2O0zAURiMEEmXgEZC8Qswiw_Vfkq4Q6kwZpBmBaNmwsRznpvEosYOdTOmD8L6kzQiWXXlxz_mudb8keUvhigLNPmxolrM0k2z5HorLDGjOU3iWLJgUPGVU0OfJ4h_yMnkV4wOAXLKCL5I_99YET9at36fbJvhx15Btg6Hz5mBaDGRvh4ZsbNe3SO5RuwqDdTuyarRz2D6ND12HQ7CGbLHrMehhDEh-eoeR1D6Qaxt7H3U5RXxbfU-v8dGaaWQdOW2PxvdINq2tkKx96PTwOnlR6zbim6f3IvmxvtmubtO7r5-_rD7dpUZINqSM08IIxrnQNaLUpWAgJTN8qStTVCArUVBK5YRkha7LcskzWdVaM5aVeY78Irmcc_fa1drt1IMfg5s2qjruzO9SIQMoQACIiX03s33wv0aMg-psNNi22qEfo-I8l4xKdhZkICQwISdQzuDxBjFgrfpgOx0OioI6NqtOzapjbQoKdWpWweRlsxf7YxcY_n_7nPhxFnG66aOdxGgsOoOVDWgGVXl7JuEvjgK84A</recordid><startdate>20081201</startdate><enddate>20081201</enddate><creator>Reichert, Anett</creator><creator>Felbel, Jana</creator><creator>Kielpinski, Mark</creator><creator>Urban, Matthias</creator><creator>Steinbrecht, Benno</creator><creator>Henkel, Thomas</creator><general>Elsevier Ltd</general><general>Springer Singapore</general><general>Microfluidics Department,Institute of Photonic Technology,07745 Jena,Germany%Arvato Digital Services Manufacturing EMEA,33311 Gütersloh,Germany</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7T7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope><scope>7SP</scope><scope>7TB</scope><scope>L7M</scope><scope>2B.</scope><scope>4A8</scope><scope>92I</scope><scope>93N</scope><scope>PSX</scope><scope>TCJ</scope></search><sort><creationdate>20081201</creationdate><title>Micro Flow-Through Thermocycler with Simple Meandering Channel with Symmetric Temperature Zones for Disposable PCR-Devices in Microscope Slide Format</title><author>Reichert, Anett ; Felbel, Jana ; Kielpinski, Mark ; Urban, Matthias ; Steinbrecht, Benno ; Henkel, Thomas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c452t-2318c42334afee5ab420552c39adc8d05d48111542368afbb9365dfaa226b77e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Artificial Intelligence</topic><topic>Biochemical Engineering</topic><topic>Bioinformatics</topic><topic>Biomaterials</topic><topic>biomedical</topic><topic>Biomedical Engineering and Bioengineering</topic><topic>Biomedical Engineering/Biotechnology</topic><topic>Engineering</topic><topic>injection molding</topic><topic>lab-on-a-chip</topic><topic>microfluidics</topic><topic>PCR</topic><topic>point-of-care</topic><topic>two-phase-flow</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Reichert, Anett</creatorcontrib><creatorcontrib>Felbel, Jana</creatorcontrib><creatorcontrib>Kielpinski, Mark</creatorcontrib><creatorcontrib>Urban, Matthias</creatorcontrib><creatorcontrib>Steinbrecht, Benno</creatorcontrib><creatorcontrib>Henkel, Thomas</creatorcontrib><collection>CrossRef</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Wanfang Data Journals - Hong Kong</collection><collection>WANFANG Data Centre</collection><collection>Wanfang Data Journals</collection><collection>万方数据期刊 - 香港版</collection><collection>China Online Journals (COJ)</collection><collection>China Online Journals (COJ)</collection><jtitle>Journal of bionics engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Reichert, Anett</au><au>Felbel, Jana</au><au>Kielpinski, Mark</au><au>Urban, Matthias</au><au>Steinbrecht, Benno</au><au>Henkel, Thomas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Micro Flow-Through Thermocycler with Simple Meandering Channel with Symmetric Temperature Zones for Disposable PCR-Devices in Microscope Slide Format</atitle><jtitle>Journal of bionics engineering</jtitle><stitle>J Bionic Eng</stitle><date>2008-12-01</date><risdate>2008</risdate><volume>5</volume><issue>4</issue><spage>291</spage><epage>298</epage><pages>291-298</pages><issn>1672-6529</issn><eissn>2543-2141</eissn><abstract>Chip-based flow-through PCR implements the PCR as a continuous process for nucleic acid analytics. The sample is transported in a winding channel through temperature zones required for denaturation, annealing and extension. Main fields of application are the monitoring of continuous processes for rapid identification of contaminants and quality control as well as high throughput screening of cells or microorganisms. A modular arrangement with five heating zones for flow-through PCR is discussed and evaluated. The special heater arrangement allows the implementation of up to 40 cycles on the footprint of a microscope slide, which is placed on top of a 5 zones heating plate. Liquid/liquid two phase flow of PCR reaction mixture and mineral oil have been applied to create a segmented flow process scheme. In that way, the developed system may provide flow-through PCR as a unit operation for the droplet based microfluidics platform. The single use of disposable devices is commonly preferred due to the sensitivity of the PCR process to contaminations. All-glass microfluidic chips and disposable chip devices, made from polycarbonate as a replication with identically geometry, have been fabricated and tested. For the first time, microchannel geometries with nearly circular profile developed by all-glass technology have been transferred to mass fabrication by injection compression molding. Both devices have been successfully applied for the detection of the tumor suppressor gene p53. Although product yield and selectivity of the amplification process do not depend on the chip material, a well defined, reliable segmented flow regime could only be realized in the all-glass chip.</abstract><cop>Singapore</cop><pub>Elsevier Ltd</pub><doi>10.1016/S1672-6529(08)60173-0</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1672-6529
ispartof Journal of bionics engineering, 2008-12, Vol.5 (4), p.291-298
issn 1672-6529
2543-2141
language eng
recordid cdi_wanfang_journals_fsgcxb_e200804004
source Access via ScienceDirect (Elsevier); Alma/SFX Local Collection; SpringerLink Journals - AutoHoldings
subjects Artificial Intelligence
Biochemical Engineering
Bioinformatics
Biomaterials
biomedical
Biomedical Engineering and Bioengineering
Biomedical Engineering/Biotechnology
Engineering
injection molding
lab-on-a-chip
microfluidics
PCR
point-of-care
two-phase-flow
title Micro Flow-Through Thermocycler with Simple Meandering Channel with Symmetric Temperature Zones for Disposable PCR-Devices in Microscope Slide Format
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T06%3A58%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wanfang_jour_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Micro%20Flow-Through%20Thermocycler%20with%20Simple%20Meandering%20Channel%20with%20Symmetric%20Temperature%20Zones%20for%20Disposable%20PCR-Devices%20in%20Microscope%20Slide%20Format&rft.jtitle=Journal%20of%20bionics%20engineering&rft.au=Reichert,%20Anett&rft.date=2008-12-01&rft.volume=5&rft.issue=4&rft.spage=291&rft.epage=298&rft.pages=291-298&rft.issn=1672-6529&rft.eissn=2543-2141&rft_id=info:doi/10.1016/S1672-6529(08)60173-0&rft_dat=%3Cwanfang_jour_proqu%3Efsgcxb_e200804004%3C/wanfang_jour_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=20450245&rft_id=info:pmid/&rft_wanfj_id=fsgcxb_e200804004&rft_els_id=S1672652908601730&rfr_iscdi=true