A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment
Flattening filter-free (FFF) beams generated by medical linear particle accelerators (linacs) have recently been used in radiotherapy clinical practice. FFF beams have fundamental physical parameter differenceswith respect to standard flattening filter (FF) beams, such that the generally used dosime...
Gespeichert in:
Veröffentlicht in: | Oncology and translational medicine 2017-12, Vol.3 (6), p.260-266 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 266 |
---|---|
container_issue | 6 |
container_start_page | 260 |
container_title | Oncology and translational medicine |
container_volume | 3 |
creator | Wagdy, Ali EI Shahat, Khaled Ashry, Huda El Shershaby, Amaal Abdo, Ehab |
description | Flattening filter-free (FFF) beams generated by medical linear particle accelerators (linacs) have recently been used in radiotherapy clinical practice. FFF beams have fundamental physical parameter differenceswith respect to standard flattening filter (FF) beams, such that the generally used dosimetric parameters and definitions are not always viable. This study investigates dosimetric parameters for use in the qualityassurance of FFF beams generated by medical linacs in radiotherapy. The main characteristics of the photon beams are analyzed using specific data generated by a Varian TrueBeam linac having both FFFand FF beams of 6 and 10 MV (megavolt) energy, respectively. Definitions for dose profile parameters are suggested, starting from the renormalization of the FFF with respect to the corresponding FF beam. Fromthis point, the flatness concept is translated into one of “un-flatness”, and other definitions are proposed, maintaining a strict parallelism between FFF and FF parameter concepts. The quality controls used inestablishing a quality assurance program when introducing FFF beams into the clinical environment are given, maintaining similarity to those used for standard FF beams, and recommendations for the introduction of FFF beams into clinical radiotherapy application for breast cancer patients are provided as an example for comparison between FFF and FF for dose distribution and coverage for a target volume. Although there aremany advantages of using a FFF beam, especially for advanced radiotherapy techniques, there are a few limitations (e.g., using a relatively higher energy photon beam for stereotactic radiotherapy (SRT), limitedspeed of current multileaf collimators (MLCs), and off-axis distance-dependent modulation in intensitymodulated radiation therapy (IMRT)) as well as challenges (e.g., criteria for beam quality evaluation andpenumbra, establishment of dosimetry methods, and consequences of photon target burn-up) that need to be addressed for establishing the FFF beam as a viable alternative to the FF beam. |
doi_str_mv | 10.1007/s10330-016-0183-3 |
format | Article |
fullrecord | <record><control><sourceid>wanfang_jour_cross</sourceid><recordid>TN_cdi_wanfang_journals_dgyx201706007</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>7000411947</cqvip_id><wanfj_id>dgyx201706007</wanfj_id><sourcerecordid>dgyx201706007</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1437-9b7f559ec8945ced238bb149958219cd8bcdafd702e40e7030f00e6da15b371a3</originalsourceid><addsrcrecordid>eNplkE9rwzAMxc3YYKXrB9jNMHbMJsdxnBxL2T8o7LKdjRPLaUrrdLa7Lt9-Li277CAkeO9J6EfILYMHBiAfAwPOIQNWpqp4xi_IJK9rkYlKVJdphjTXZc6uySyENQDkdSFLkU-Im9N22O6017H_Rhri3oy0wXhAdNRudIzoetdR228i-sx6xCTrbaDamf-Gs9Y76rXph7hCr3cjjR513KKLN-TK6k3A2blPyefz08fiNVu-v7wt5susZQWXWd1IK0SNbVUXokWT86ppWJFeqnJWt6ZqWqOtkZBjASiBgwXA0mgmGi6Z5lNyf9p70M5q16n1sPcuXVSmG39yYBLKRC752MnX-iEEj1btfL_VflQM1JGtOrFVia06slU8Ze7OmdXguq_0_F9IJrQFYwku_wXsKHly</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment</title><source>DOAJ Directory of Open Access Journals</source><creator>Wagdy, Ali ; EI Shahat, Khaled ; Ashry, Huda ; El Shershaby, Amaal ; Abdo, Ehab</creator><creatorcontrib>Wagdy, Ali ; EI Shahat, Khaled ; Ashry, Huda ; El Shershaby, Amaal ; Abdo, Ehab</creatorcontrib><description>Flattening filter-free (FFF) beams generated by medical linear particle accelerators (linacs) have recently been used in radiotherapy clinical practice. FFF beams have fundamental physical parameter differenceswith respect to standard flattening filter (FF) beams, such that the generally used dosimetric parameters and definitions are not always viable. This study investigates dosimetric parameters for use in the qualityassurance of FFF beams generated by medical linacs in radiotherapy. The main characteristics of the photon beams are analyzed using specific data generated by a Varian TrueBeam linac having both FFFand FF beams of 6 and 10 MV (megavolt) energy, respectively. Definitions for dose profile parameters are suggested, starting from the renormalization of the FFF with respect to the corresponding FF beam. Fromthis point, the flatness concept is translated into one of “un-flatness”, and other definitions are proposed, maintaining a strict parallelism between FFF and FF parameter concepts. The quality controls used inestablishing a quality assurance program when introducing FFF beams into the clinical environment are given, maintaining similarity to those used for standard FF beams, and recommendations for the introduction of FFF beams into clinical radiotherapy application for breast cancer patients are provided as an example for comparison between FFF and FF for dose distribution and coverage for a target volume. Although there aremany advantages of using a FFF beam, especially for advanced radiotherapy techniques, there are a few limitations (e.g., using a relatively higher energy photon beam for stereotactic radiotherapy (SRT), limitedspeed of current multileaf collimators (MLCs), and off-axis distance-dependent modulation in intensitymodulated radiation therapy (IMRT)) as well as challenges (e.g., criteria for beam quality evaluation andpenumbra, establishment of dosimetry methods, and consequences of photon target burn-up) that need to be addressed for establishing the FFF beam as a viable alternative to the FF beam.</description><identifier>ISSN: 2095-9621</identifier><identifier>EISSN: 2995-5858</identifier><identifier>DOI: 10.1007/s10330-016-0183-3</identifier><language>eng</language><publisher>Al Galaa Oncology Center, Egypt%Clinical Oncology Department-Faculty of Medicine-Al Azhar University, Cairo, Egypt%National Center for Radiation Research and Technology-AEA, Egypt%Physics Department Women College for Arts Science and Education-Ain Sham University, Cairo,Egypt</publisher><subject>beam ; breast ; cancer ; characteristics ; collimator ; filter ; filter-free ; flattening ; multileaf ; planning ; treatment</subject><ispartof>Oncology and translational medicine, 2017-12, Vol.3 (6), p.260-266</ispartof><rights>Copyright © Wanfang Data Co. Ltd. All Rights Reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1437-9b7f559ec8945ced238bb149958219cd8bcdafd702e40e7030f00e6da15b371a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/90333B/90333B.jpg</thumbnail><link.rule.ids>315,781,785,865,27929,27930</link.rule.ids></links><search><creatorcontrib>Wagdy, Ali</creatorcontrib><creatorcontrib>EI Shahat, Khaled</creatorcontrib><creatorcontrib>Ashry, Huda</creatorcontrib><creatorcontrib>El Shershaby, Amaal</creatorcontrib><creatorcontrib>Abdo, Ehab</creatorcontrib><title>A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment</title><title>Oncology and translational medicine</title><addtitle>Oncology and Translational Medicine</addtitle><description>Flattening filter-free (FFF) beams generated by medical linear particle accelerators (linacs) have recently been used in radiotherapy clinical practice. FFF beams have fundamental physical parameter differenceswith respect to standard flattening filter (FF) beams, such that the generally used dosimetric parameters and definitions are not always viable. This study investigates dosimetric parameters for use in the qualityassurance of FFF beams generated by medical linacs in radiotherapy. The main characteristics of the photon beams are analyzed using specific data generated by a Varian TrueBeam linac having both FFFand FF beams of 6 and 10 MV (megavolt) energy, respectively. Definitions for dose profile parameters are suggested, starting from the renormalization of the FFF with respect to the corresponding FF beam. Fromthis point, the flatness concept is translated into one of “un-flatness”, and other definitions are proposed, maintaining a strict parallelism between FFF and FF parameter concepts. The quality controls used inestablishing a quality assurance program when introducing FFF beams into the clinical environment are given, maintaining similarity to those used for standard FF beams, and recommendations for the introduction of FFF beams into clinical radiotherapy application for breast cancer patients are provided as an example for comparison between FFF and FF for dose distribution and coverage for a target volume. Although there aremany advantages of using a FFF beam, especially for advanced radiotherapy techniques, there are a few limitations (e.g., using a relatively higher energy photon beam for stereotactic radiotherapy (SRT), limitedspeed of current multileaf collimators (MLCs), and off-axis distance-dependent modulation in intensitymodulated radiation therapy (IMRT)) as well as challenges (e.g., criteria for beam quality evaluation andpenumbra, establishment of dosimetry methods, and consequences of photon target burn-up) that need to be addressed for establishing the FFF beam as a viable alternative to the FF beam.</description><subject>beam</subject><subject>breast</subject><subject>cancer</subject><subject>characteristics</subject><subject>collimator</subject><subject>filter</subject><subject>filter-free</subject><subject>flattening</subject><subject>multileaf</subject><subject>planning</subject><subject>treatment</subject><issn>2095-9621</issn><issn>2995-5858</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNplkE9rwzAMxc3YYKXrB9jNMHbMJsdxnBxL2T8o7LKdjRPLaUrrdLa7Lt9-Li277CAkeO9J6EfILYMHBiAfAwPOIQNWpqp4xi_IJK9rkYlKVJdphjTXZc6uySyENQDkdSFLkU-Im9N22O6017H_Rhri3oy0wXhAdNRudIzoetdR228i-sx6xCTrbaDamf-Gs9Y76rXph7hCr3cjjR513KKLN-TK6k3A2blPyefz08fiNVu-v7wt5susZQWXWd1IK0SNbVUXokWT86ppWJFeqnJWt6ZqWqOtkZBjASiBgwXA0mgmGi6Z5lNyf9p70M5q16n1sPcuXVSmG39yYBLKRC752MnX-iEEj1btfL_VflQM1JGtOrFVia06slU8Ze7OmdXguq_0_F9IJrQFYwku_wXsKHly</recordid><startdate>201712</startdate><enddate>201712</enddate><creator>Wagdy, Ali</creator><creator>EI Shahat, Khaled</creator><creator>Ashry, Huda</creator><creator>El Shershaby, Amaal</creator><creator>Abdo, Ehab</creator><general>Al Galaa Oncology Center, Egypt%Clinical Oncology Department-Faculty of Medicine-Al Azhar University, Cairo, Egypt%National Center for Radiation Research and Technology-AEA, Egypt%Physics Department Women College for Arts Science and Education-Ain Sham University, Cairo,Egypt</general><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W91</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>2B.</scope><scope>4A8</scope><scope>92I</scope><scope>93N</scope><scope>PSX</scope><scope>TCJ</scope></search><sort><creationdate>201712</creationdate><title>A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment</title><author>Wagdy, Ali ; EI Shahat, Khaled ; Ashry, Huda ; El Shershaby, Amaal ; Abdo, Ehab</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1437-9b7f559ec8945ced238bb149958219cd8bcdafd702e40e7030f00e6da15b371a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>beam</topic><topic>breast</topic><topic>cancer</topic><topic>characteristics</topic><topic>collimator</topic><topic>filter</topic><topic>filter-free</topic><topic>flattening</topic><topic>multileaf</topic><topic>planning</topic><topic>treatment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wagdy, Ali</creatorcontrib><creatorcontrib>EI Shahat, Khaled</creatorcontrib><creatorcontrib>Ashry, Huda</creatorcontrib><creatorcontrib>El Shershaby, Amaal</creatorcontrib><creatorcontrib>Abdo, Ehab</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-医药卫生</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Wanfang Data Journals - Hong Kong</collection><collection>WANFANG Data Centre</collection><collection>Wanfang Data Journals</collection><collection>万方数据期刊 - 香港版</collection><collection>China Online Journals (COJ)</collection><collection>China Online Journals (COJ)</collection><jtitle>Oncology and translational medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wagdy, Ali</au><au>EI Shahat, Khaled</au><au>Ashry, Huda</au><au>El Shershaby, Amaal</au><au>Abdo, Ehab</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment</atitle><jtitle>Oncology and translational medicine</jtitle><addtitle>Oncology and Translational Medicine</addtitle><date>2017-12</date><risdate>2017</risdate><volume>3</volume><issue>6</issue><spage>260</spage><epage>266</epage><pages>260-266</pages><issn>2095-9621</issn><eissn>2995-5858</eissn><abstract>Flattening filter-free (FFF) beams generated by medical linear particle accelerators (linacs) have recently been used in radiotherapy clinical practice. FFF beams have fundamental physical parameter differenceswith respect to standard flattening filter (FF) beams, such that the generally used dosimetric parameters and definitions are not always viable. This study investigates dosimetric parameters for use in the qualityassurance of FFF beams generated by medical linacs in radiotherapy. The main characteristics of the photon beams are analyzed using specific data generated by a Varian TrueBeam linac having both FFFand FF beams of 6 and 10 MV (megavolt) energy, respectively. Definitions for dose profile parameters are suggested, starting from the renormalization of the FFF with respect to the corresponding FF beam. Fromthis point, the flatness concept is translated into one of “un-flatness”, and other definitions are proposed, maintaining a strict parallelism between FFF and FF parameter concepts. The quality controls used inestablishing a quality assurance program when introducing FFF beams into the clinical environment are given, maintaining similarity to those used for standard FF beams, and recommendations for the introduction of FFF beams into clinical radiotherapy application for breast cancer patients are provided as an example for comparison between FFF and FF for dose distribution and coverage for a target volume. Although there aremany advantages of using a FFF beam, especially for advanced radiotherapy techniques, there are a few limitations (e.g., using a relatively higher energy photon beam for stereotactic radiotherapy (SRT), limitedspeed of current multileaf collimators (MLCs), and off-axis distance-dependent modulation in intensitymodulated radiation therapy (IMRT)) as well as challenges (e.g., criteria for beam quality evaluation andpenumbra, establishment of dosimetry methods, and consequences of photon target burn-up) that need to be addressed for establishing the FFF beam as a viable alternative to the FF beam.</abstract><pub>Al Galaa Oncology Center, Egypt%Clinical Oncology Department-Faculty of Medicine-Al Azhar University, Cairo, Egypt%National Center for Radiation Research and Technology-AEA, Egypt%Physics Department Women College for Arts Science and Education-Ain Sham University, Cairo,Egypt</pub><doi>10.1007/s10330-016-0183-3</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2095-9621 |
ispartof | Oncology and translational medicine, 2017-12, Vol.3 (6), p.260-266 |
issn | 2095-9621 2995-5858 |
language | eng |
recordid | cdi_wanfang_journals_dgyx201706007 |
source | DOAJ Directory of Open Access Journals |
subjects | beam breast cancer characteristics collimator filter filter-free flattening multileaf planning treatment |
title | A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T09%3A30%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wanfang_jour_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20comparative%20study%20between%20flattening%20filter-free%20beams%20and%20flattening%20filter%20beams%20in%20radiotherapy%20treatment&rft.jtitle=Oncology%20and%20translational%20medicine&rft.au=Wagdy,%20Ali&rft.date=2017-12&rft.volume=3&rft.issue=6&rft.spage=260&rft.epage=266&rft.pages=260-266&rft.issn=2095-9621&rft.eissn=2995-5858&rft_id=info:doi/10.1007/s10330-016-0183-3&rft_dat=%3Cwanfang_jour_cross%3Edgyx201706007%3C/wanfang_jour_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_cqvip_id=7000411947&rft_wanfj_id=dgyx201706007&rfr_iscdi=true |