Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector

Rationale and objectives The purpose of this study was to evaluate the feasibility of unconstrained three-material decomposition in a human tissue specimen containing iodinated contrast agent, using an experimental multi-bin photon-counting silicon detector. It was further to evaluate potential adde...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European radiology 2020-11, Vol.30 (11), p.5904-5912
Hauptverfasser: Grönberg, Fredrik, Lundberg, Johan, Sjölin, Martin, Persson, Mats, Bujila, Robert, Bornefalk, Hans, Almqvist, Håkan, Holmin, Staffan, Danielsson, Mats
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 5912
container_issue 11
container_start_page 5904
container_title European radiology
container_volume 30
creator Grönberg, Fredrik
Lundberg, Johan
Sjölin, Martin
Persson, Mats
Bujila, Robert
Bornefalk, Hans
Almqvist, Håkan
Holmin, Staffan
Danielsson, Mats
description Rationale and objectives The purpose of this study was to evaluate the feasibility of unconstrained three-material decomposition in a human tissue specimen containing iodinated contrast agent, using an experimental multi-bin photon-counting silicon detector. It was further to evaluate potential added clinical value compared to a 1st-generation state-of-the-art dual-energy computed tomography system. Materials and methods A prototype photon-counting silicon detector in a bench-top setup for x-ray tomographic imaging was calibrated using a multi-material calibration phantom. A heart with calcified plaque was obtained from a deceased patient, and the coronary arteries were injected with an iodinated contrast agent mixed with gelatin. The heart was imaged in the experimental setup and on a 1st-generation state-of-the-art dual-energy computed tomography system. Projection-based three-material decomposition without any constraints was performed with the photon-counting detector data, and the resulting images were compared with those obtained from the dual-energy system. Results The photon-counting detector images show better separation of iodine and calcium compared to the dual-energy images. Additional experiments confirmed that unbiased estimates of soft tissue, calcium, and iodine could be achieved without any constraints. Conclusion The proposed experimental system could provide added clinical value compared to current dual-energy systems for imaging tasks where mix-up of iodine and calcium is an issue, and the anatomy is sufficiently small to allow iodine to be differentiated from calcium. Considering its previously shown count rate capability, these results show promise for future integration of this detector in a clinical CT scanner. Key Points • Spectral photon-counting detectors can solve some of the fundamental problems with conventional single-energy CT. • Dual-energy methods can be used to differentiate iodine and calcium, but to do so must rely on constraints, since solving for three unknowns with only two measurements is not possible. Photon-counting detectors can improve upon these methods by allowing unconstrained three-material decomposition. • A prototype photon-counting silicon detector with high count rate capability allows performing unconstrained three-material decomposition and qualitatively shows better differentiation of iodine and calcium than dual-energy CT.
doi_str_mv 10.1007/s00330-020-07017-y
format Article
fullrecord <record><control><sourceid>proquest_swepu</sourceid><recordid>TN_cdi_swepub_primary_oai_swepub_ki_se_470189</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2418133734</sourcerecordid><originalsourceid>FETCH-LOGICAL-c522t-4d6b4e3cf8c123709521e7e67f0dc7a443a30090a470de4fd27adf42ba2b26033</originalsourceid><addsrcrecordid>eNp9kk1v1DAQhiMEokvhD3BAPnJJ8VfWCQekaqGAVIlL4Wo5zmTjNrGD7QD7K_jLne0uFb30YPljnnnHY79F8ZrRM0apepcoFYKWlONQlKly96RYMSl4yWgtnxYr2oi6VE0jT4oXKV1TShsm1fPiRPCqrjnjq-LvBZjkWje6vCOhJ4u3waccjfPQkTxEgHIyGaIzI-nAhmkOyWUX_HviJrN1fkuMJ_DHuoQJwzLhbgATM1nSXZDMMeSQdzOQhGVQnswDnvjShsXnPbO5QukMNof4snjWmzHBq-N8Wny_-HS1-VJefvv8dXN-WdqK81zKbt1KELavLeNC0abiDBSsVU87q4yUwgjslhqpaAey77gyXS95a3jL1_hsp0V50E2_YV5aPUfsJu50ME4fj25wBRoFWN08yn90P851iFt9kwfNa8GZQv7DgUd4gs6CxzcdH6Q9jHg36G34pVVVScr2F3x7FIjh5wIp68klC-NoPIQlaS5ZjZgSElF-QG0MKUXo78swqvdO0QenaHSKvnOK3mHSm_8veJ_yzxoIiGPHGPJbiPo6LNHjpzwmews9Lc-A</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2418133734</pqid></control><display><type>article</type><title>Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector</title><source>MEDLINE</source><source>SWEPUB Freely available online</source><source>SpringerLink Journals - AutoHoldings</source><creator>Grönberg, Fredrik ; Lundberg, Johan ; Sjölin, Martin ; Persson, Mats ; Bujila, Robert ; Bornefalk, Hans ; Almqvist, Håkan ; Holmin, Staffan ; Danielsson, Mats</creator><creatorcontrib>Grönberg, Fredrik ; Lundberg, Johan ; Sjölin, Martin ; Persson, Mats ; Bujila, Robert ; Bornefalk, Hans ; Almqvist, Håkan ; Holmin, Staffan ; Danielsson, Mats</creatorcontrib><description>Rationale and objectives The purpose of this study was to evaluate the feasibility of unconstrained three-material decomposition in a human tissue specimen containing iodinated contrast agent, using an experimental multi-bin photon-counting silicon detector. It was further to evaluate potential added clinical value compared to a 1st-generation state-of-the-art dual-energy computed tomography system. Materials and methods A prototype photon-counting silicon detector in a bench-top setup for x-ray tomographic imaging was calibrated using a multi-material calibration phantom. A heart with calcified plaque was obtained from a deceased patient, and the coronary arteries were injected with an iodinated contrast agent mixed with gelatin. The heart was imaged in the experimental setup and on a 1st-generation state-of-the-art dual-energy computed tomography system. Projection-based three-material decomposition without any constraints was performed with the photon-counting detector data, and the resulting images were compared with those obtained from the dual-energy system. Results The photon-counting detector images show better separation of iodine and calcium compared to the dual-energy images. Additional experiments confirmed that unbiased estimates of soft tissue, calcium, and iodine could be achieved without any constraints. Conclusion The proposed experimental system could provide added clinical value compared to current dual-energy systems for imaging tasks where mix-up of iodine and calcium is an issue, and the anatomy is sufficiently small to allow iodine to be differentiated from calcium. Considering its previously shown count rate capability, these results show promise for future integration of this detector in a clinical CT scanner. Key Points • Spectral photon-counting detectors can solve some of the fundamental problems with conventional single-energy CT. • Dual-energy methods can be used to differentiate iodine and calcium, but to do so must rely on constraints, since solving for three unknowns with only two measurements is not possible. Photon-counting detectors can improve upon these methods by allowing unconstrained three-material decomposition. • A prototype photon-counting silicon detector with high count rate capability allows performing unconstrained three-material decomposition and qualitatively shows better differentiation of iodine and calcium than dual-energy CT.</description><identifier>ISSN: 0938-7994</identifier><identifier>ISSN: 1432-1084</identifier><identifier>EISSN: 1432-1084</identifier><identifier>DOI: 10.1007/s00330-020-07017-y</identifier><identifier>PMID: 32588212</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Calibration ; Contrast Media - pharmacology ; Diagnostic Radiology ; Experimental ; Feasibility Studies ; Humans ; Imaging ; Internal Medicine ; Interventional Radiology ; Medicine ; Medicine &amp; Public Health ; Neuroradiology ; Phantoms, Imaging ; Radiology ; Silicon ; Tomography, X-Ray Computed - methods ; Ultrasound</subject><ispartof>European radiology, 2020-11, Vol.30 (11), p.5904-5912</ispartof><rights>The Author(s) 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c522t-4d6b4e3cf8c123709521e7e67f0dc7a443a30090a470de4fd27adf42ba2b26033</citedby><cites>FETCH-LOGICAL-c522t-4d6b4e3cf8c123709521e7e67f0dc7a443a30090a470de4fd27adf42ba2b26033</cites><orcidid>0000-0003-1428-8351</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00330-020-07017-y$$EPDF$$P50$$Gspringer$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00330-020-07017-y$$EHTML$$P50$$Gspringer$$Hfree_for_read</linktohtml><link.rule.ids>230,314,550,776,780,881,27901,27902,41464,42533,51294</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32588212$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-283217$$DView record from Swedish Publication Index$$Hfree_for_read</backlink><backlink>$$Uhttp://kipublications.ki.se/Default.aspx?queryparsed=id:144050497$$DView record from Swedish Publication Index$$Hfree_for_read</backlink></links><search><creatorcontrib>Grönberg, Fredrik</creatorcontrib><creatorcontrib>Lundberg, Johan</creatorcontrib><creatorcontrib>Sjölin, Martin</creatorcontrib><creatorcontrib>Persson, Mats</creatorcontrib><creatorcontrib>Bujila, Robert</creatorcontrib><creatorcontrib>Bornefalk, Hans</creatorcontrib><creatorcontrib>Almqvist, Håkan</creatorcontrib><creatorcontrib>Holmin, Staffan</creatorcontrib><creatorcontrib>Danielsson, Mats</creatorcontrib><title>Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector</title><title>European radiology</title><addtitle>Eur Radiol</addtitle><addtitle>Eur Radiol</addtitle><description>Rationale and objectives The purpose of this study was to evaluate the feasibility of unconstrained three-material decomposition in a human tissue specimen containing iodinated contrast agent, using an experimental multi-bin photon-counting silicon detector. It was further to evaluate potential added clinical value compared to a 1st-generation state-of-the-art dual-energy computed tomography system. Materials and methods A prototype photon-counting silicon detector in a bench-top setup for x-ray tomographic imaging was calibrated using a multi-material calibration phantom. A heart with calcified plaque was obtained from a deceased patient, and the coronary arteries were injected with an iodinated contrast agent mixed with gelatin. The heart was imaged in the experimental setup and on a 1st-generation state-of-the-art dual-energy computed tomography system. Projection-based three-material decomposition without any constraints was performed with the photon-counting detector data, and the resulting images were compared with those obtained from the dual-energy system. Results The photon-counting detector images show better separation of iodine and calcium compared to the dual-energy images. Additional experiments confirmed that unbiased estimates of soft tissue, calcium, and iodine could be achieved without any constraints. Conclusion The proposed experimental system could provide added clinical value compared to current dual-energy systems for imaging tasks where mix-up of iodine and calcium is an issue, and the anatomy is sufficiently small to allow iodine to be differentiated from calcium. Considering its previously shown count rate capability, these results show promise for future integration of this detector in a clinical CT scanner. Key Points • Spectral photon-counting detectors can solve some of the fundamental problems with conventional single-energy CT. • Dual-energy methods can be used to differentiate iodine and calcium, but to do so must rely on constraints, since solving for three unknowns with only two measurements is not possible. Photon-counting detectors can improve upon these methods by allowing unconstrained three-material decomposition. • A prototype photon-counting silicon detector with high count rate capability allows performing unconstrained three-material decomposition and qualitatively shows better differentiation of iodine and calcium than dual-energy CT.</description><subject>Calibration</subject><subject>Contrast Media - pharmacology</subject><subject>Diagnostic Radiology</subject><subject>Experimental</subject><subject>Feasibility Studies</subject><subject>Humans</subject><subject>Imaging</subject><subject>Internal Medicine</subject><subject>Interventional Radiology</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Neuroradiology</subject><subject>Phantoms, Imaging</subject><subject>Radiology</subject><subject>Silicon</subject><subject>Tomography, X-Ray Computed - methods</subject><subject>Ultrasound</subject><issn>0938-7994</issn><issn>1432-1084</issn><issn>1432-1084</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>C6C</sourceid><sourceid>EIF</sourceid><sourceid>D8T</sourceid><recordid>eNp9kk1v1DAQhiMEokvhD3BAPnJJ8VfWCQekaqGAVIlL4Wo5zmTjNrGD7QD7K_jLne0uFb30YPljnnnHY79F8ZrRM0apepcoFYKWlONQlKly96RYMSl4yWgtnxYr2oi6VE0jT4oXKV1TShsm1fPiRPCqrjnjq-LvBZjkWje6vCOhJ4u3waccjfPQkTxEgHIyGaIzI-nAhmkOyWUX_HviJrN1fkuMJ_DHuoQJwzLhbgATM1nSXZDMMeSQdzOQhGVQnswDnvjShsXnPbO5QukMNof4snjWmzHBq-N8Wny_-HS1-VJefvv8dXN-WdqK81zKbt1KELavLeNC0abiDBSsVU87q4yUwgjslhqpaAey77gyXS95a3jL1_hsp0V50E2_YV5aPUfsJu50ME4fj25wBRoFWN08yn90P851iFt9kwfNa8GZQv7DgUd4gs6CxzcdH6Q9jHg36G34pVVVScr2F3x7FIjh5wIp68klC-NoPIQlaS5ZjZgSElF-QG0MKUXo78swqvdO0QenaHSKvnOK3mHSm_8veJ_yzxoIiGPHGPJbiPo6LNHjpzwmews9Lc-A</recordid><startdate>20201101</startdate><enddate>20201101</enddate><creator>Grönberg, Fredrik</creator><creator>Lundberg, Johan</creator><creator>Sjölin, Martin</creator><creator>Persson, Mats</creator><creator>Bujila, Robert</creator><creator>Bornefalk, Hans</creator><creator>Almqvist, Håkan</creator><creator>Holmin, Staffan</creator><creator>Danielsson, Mats</creator><general>Springer Berlin Heidelberg</general><scope>C6C</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>ADTPV</scope><scope>AFDQA</scope><scope>AOWAS</scope><scope>D8T</scope><scope>D8V</scope><scope>ZZAVC</scope><orcidid>https://orcid.org/0000-0003-1428-8351</orcidid></search><sort><creationdate>20201101</creationdate><title>Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector</title><author>Grönberg, Fredrik ; Lundberg, Johan ; Sjölin, Martin ; Persson, Mats ; Bujila, Robert ; Bornefalk, Hans ; Almqvist, Håkan ; Holmin, Staffan ; Danielsson, Mats</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c522t-4d6b4e3cf8c123709521e7e67f0dc7a443a30090a470de4fd27adf42ba2b26033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Calibration</topic><topic>Contrast Media - pharmacology</topic><topic>Diagnostic Radiology</topic><topic>Experimental</topic><topic>Feasibility Studies</topic><topic>Humans</topic><topic>Imaging</topic><topic>Internal Medicine</topic><topic>Interventional Radiology</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Neuroradiology</topic><topic>Phantoms, Imaging</topic><topic>Radiology</topic><topic>Silicon</topic><topic>Tomography, X-Ray Computed - methods</topic><topic>Ultrasound</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Grönberg, Fredrik</creatorcontrib><creatorcontrib>Lundberg, Johan</creatorcontrib><creatorcontrib>Sjölin, Martin</creatorcontrib><creatorcontrib>Persson, Mats</creatorcontrib><creatorcontrib>Bujila, Robert</creatorcontrib><creatorcontrib>Bornefalk, Hans</creatorcontrib><creatorcontrib>Almqvist, Håkan</creatorcontrib><creatorcontrib>Holmin, Staffan</creatorcontrib><creatorcontrib>Danielsson, Mats</creatorcontrib><collection>Springer Nature OA Free Journals</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>SwePub</collection><collection>SWEPUB Kungliga Tekniska Högskolan full text</collection><collection>SwePub Articles</collection><collection>SWEPUB Freely available online</collection><collection>SWEPUB Kungliga Tekniska Högskolan</collection><collection>SwePub Articles full text</collection><jtitle>European radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Grönberg, Fredrik</au><au>Lundberg, Johan</au><au>Sjölin, Martin</au><au>Persson, Mats</au><au>Bujila, Robert</au><au>Bornefalk, Hans</au><au>Almqvist, Håkan</au><au>Holmin, Staffan</au><au>Danielsson, Mats</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector</atitle><jtitle>European radiology</jtitle><stitle>Eur Radiol</stitle><addtitle>Eur Radiol</addtitle><date>2020-11-01</date><risdate>2020</risdate><volume>30</volume><issue>11</issue><spage>5904</spage><epage>5912</epage><pages>5904-5912</pages><issn>0938-7994</issn><issn>1432-1084</issn><eissn>1432-1084</eissn><abstract>Rationale and objectives The purpose of this study was to evaluate the feasibility of unconstrained three-material decomposition in a human tissue specimen containing iodinated contrast agent, using an experimental multi-bin photon-counting silicon detector. It was further to evaluate potential added clinical value compared to a 1st-generation state-of-the-art dual-energy computed tomography system. Materials and methods A prototype photon-counting silicon detector in a bench-top setup for x-ray tomographic imaging was calibrated using a multi-material calibration phantom. A heart with calcified plaque was obtained from a deceased patient, and the coronary arteries were injected with an iodinated contrast agent mixed with gelatin. The heart was imaged in the experimental setup and on a 1st-generation state-of-the-art dual-energy computed tomography system. Projection-based three-material decomposition without any constraints was performed with the photon-counting detector data, and the resulting images were compared with those obtained from the dual-energy system. Results The photon-counting detector images show better separation of iodine and calcium compared to the dual-energy images. Additional experiments confirmed that unbiased estimates of soft tissue, calcium, and iodine could be achieved without any constraints. Conclusion The proposed experimental system could provide added clinical value compared to current dual-energy systems for imaging tasks where mix-up of iodine and calcium is an issue, and the anatomy is sufficiently small to allow iodine to be differentiated from calcium. Considering its previously shown count rate capability, these results show promise for future integration of this detector in a clinical CT scanner. Key Points • Spectral photon-counting detectors can solve some of the fundamental problems with conventional single-energy CT. • Dual-energy methods can be used to differentiate iodine and calcium, but to do so must rely on constraints, since solving for three unknowns with only two measurements is not possible. Photon-counting detectors can improve upon these methods by allowing unconstrained three-material decomposition. • A prototype photon-counting silicon detector with high count rate capability allows performing unconstrained three-material decomposition and qualitatively shows better differentiation of iodine and calcium than dual-energy CT.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>32588212</pmid><doi>10.1007/s00330-020-07017-y</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0003-1428-8351</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0938-7994
ispartof European radiology, 2020-11, Vol.30 (11), p.5904-5912
issn 0938-7994
1432-1084
1432-1084
language eng
recordid cdi_swepub_primary_oai_swepub_ki_se_470189
source MEDLINE; SWEPUB Freely available online; SpringerLink Journals - AutoHoldings
subjects Calibration
Contrast Media - pharmacology
Diagnostic Radiology
Experimental
Feasibility Studies
Humans
Imaging
Internal Medicine
Interventional Radiology
Medicine
Medicine & Public Health
Neuroradiology
Phantoms, Imaging
Radiology
Silicon
Tomography, X-Ray Computed - methods
Ultrasound
title Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T23%3A43%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_swepu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Feasibility%20of%20unconstrained%20three-material%20decomposition:%20imaging%20an%20excised%20human%20heart%20using%20a%20prototype%20silicon%20photon-counting%20CT%20detector&rft.jtitle=European%20radiology&rft.au=Gr%C3%B6nberg,%20Fredrik&rft.date=2020-11-01&rft.volume=30&rft.issue=11&rft.spage=5904&rft.epage=5912&rft.pages=5904-5912&rft.issn=0938-7994&rft.eissn=1432-1084&rft_id=info:doi/10.1007/s00330-020-07017-y&rft_dat=%3Cproquest_swepu%3E2418133734%3C/proquest_swepu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2418133734&rft_id=info:pmid/32588212&rfr_iscdi=true