Case Studies in Physiology: Ventilation and perfusion in a giraffe-does size matter?
The trachea in the giraffe is long but narrow, and dead space ventilation is considered to be of approximately the same size as in other mammals. Less is known about the matching between ventilation and lung blood flow. The lungs in the giraffe are large, up to 1 m high and 0.7 m wide, and this may...
Gespeichert in:
Veröffentlicht in: | Journal of applied physiology (1985) 2016-12, Vol.121 (6), p.1374-1378 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1378 |
---|---|
container_issue | 6 |
container_start_page | 1374 |
container_title | Journal of applied physiology (1985) |
container_volume | 121 |
creator | Nyman, Görel Röken, Bengt Hedin, Eva-Maria Hedenstierna, Göran |
description | The trachea in the giraffe is long but narrow, and dead space ventilation is considered to be of approximately the same size as in other mammals. Less is known about the matching between ventilation and lung blood flow. The lungs in the giraffe are large, up to 1 m high and 0.7 m wide, and this may cause considerable ventilation/perfusion (V
/Q) mismatch due to the influence of gravitational forces, which could lead to hypoxemia. We studied a young giraffe under anesthesia using the multiple inert gas elimination technique to analyze the VA/Q distribution and arterial oxygenation and compared the results with those obtained in other species of different sizes, including humans. V
/Q distribution was broad but unimodal, and the shunt of blood flow through nonventilated lung regions was essentially absent, suggesting no lung collapse. The V
/Q match was as good as in the similarly sized horse and was even comparable to that in smaller sized animals, including rabbit and rat. The match was also similar to that in anesthetized humans. Arterial oxygenation was essentially similar in all studied species. The findings suggest that the efficiency of V
/Q matching is independent of lung size in the studied mammals that vary in weight from less than 1 to more than 400 kg. |
doi_str_mv | 10.1152/japplphysiol.00428.2016 |
format | Article |
fullrecord | <record><control><sourceid>proquest_swepu</sourceid><recordid>TN_cdi_swepub_primary_oai_slubar_slu_se_84077</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1852778700</sourcerecordid><originalsourceid>FETCH-LOGICAL-c437t-22d7a90d2e7b13d794f45c6526141fa4d2a7a43985213fd14e6aa6036475cb303</originalsourceid><addsrcrecordid>eNp1kc1O3DAURi0EKlPaV4AsWZDBf7EzbBAaSouERKVSttZNfDMYZeJgx6qGpydhAHXD6sry-T5f-RByxOicsYKfPkLft_3DJjrfzimVvJxzytQOmY23PGeKsl0yK3VBc12Uep98jfGRUiZlwb6Qfa6VonxRzsjdEiJmf4ZkHcbMddnvbalfbc6ye-wG18LgfJdBZ7MeQ5PidBpByFYuQNNgbv0Yje4ZszUMA4bzb2SvgTbi97d5QP5e_bhb_spvbn9eLy9u8loKPeScWw0LajnqigmrF7KRRa0KrphkDUjLQYMUi7LgTDSWSVQAigoldVFXgooDkm974z_sU2X64NYQNsaDM7FNFYRpmIimlFTrkT_5lL909xfGh5VJyQimxo8a8eMt3gf_lDAOZu1ijW0LHfoUDRsX07rUdNpEb9E6-BgDNh_djJrJmPnfmHk1ZiZjY_Lw7ZFUrdF-5N4ViRcjuJZA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1852778700</pqid></control><display><type>article</type><title>Case Studies in Physiology: Ventilation and perfusion in a giraffe-does size matter?</title><source>MEDLINE</source><source>American Physiological Society</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Nyman, Görel ; Röken, Bengt ; Hedin, Eva-Maria ; Hedenstierna, Göran</creator><creatorcontrib>Nyman, Görel ; Röken, Bengt ; Hedin, Eva-Maria ; Hedenstierna, Göran ; Sveriges lantbruksuniversitet</creatorcontrib><description>The trachea in the giraffe is long but narrow, and dead space ventilation is considered to be of approximately the same size as in other mammals. Less is known about the matching between ventilation and lung blood flow. The lungs in the giraffe are large, up to 1 m high and 0.7 m wide, and this may cause considerable ventilation/perfusion (V
/Q) mismatch due to the influence of gravitational forces, which could lead to hypoxemia. We studied a young giraffe under anesthesia using the multiple inert gas elimination technique to analyze the VA/Q distribution and arterial oxygenation and compared the results with those obtained in other species of different sizes, including humans. V
/Q distribution was broad but unimodal, and the shunt of blood flow through nonventilated lung regions was essentially absent, suggesting no lung collapse. The V
/Q match was as good as in the similarly sized horse and was even comparable to that in smaller sized animals, including rabbit and rat. The match was also similar to that in anesthetized humans. Arterial oxygenation was essentially similar in all studied species. The findings suggest that the efficiency of V
/Q matching is independent of lung size in the studied mammals that vary in weight from less than 1 to more than 400 kg.</description><identifier>ISSN: 8750-7587</identifier><identifier>ISSN: 1522-1601</identifier><identifier>EISSN: 1522-1601</identifier><identifier>DOI: 10.1152/japplphysiol.00428.2016</identifier><identifier>PMID: 27660298</identifier><language>eng</language><publisher>United States</publisher><subject>Animals ; Clinical Science ; Female ; gas exchange ; giraffe ; Giraffes - physiology ; Horses ; Humans ; Klinisk vetenskap ; Lung - physiology ; Pulmonary Gas Exchange - physiology ; Pulmonary Ventilation - physiology ; Rabbits ; Rats ; Regional Blood Flow - physiology ; Respiration ; ventilation ; Ventilation-Perfusion Ratio - physiology ; ventilation/perfusion</subject><ispartof>Journal of applied physiology (1985), 2016-12, Vol.121 (6), p.1374-1378</ispartof><rights>Copyright © 2016 the American Physiological Society.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c437t-22d7a90d2e7b13d794f45c6526141fa4d2a7a43985213fd14e6aa6036475cb303</citedby><cites>FETCH-LOGICAL-c437t-22d7a90d2e7b13d794f45c6526141fa4d2a7a43985213fd14e6aa6036475cb303</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,3025,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27660298$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-316445$$DView record from Swedish Publication Index$$Hfree_for_read</backlink><backlink>$$Uhttps://res.slu.se/id/publ/84077$$DView record from Swedish Publication Index$$Hfree_for_read</backlink></links><search><creatorcontrib>Nyman, Görel</creatorcontrib><creatorcontrib>Röken, Bengt</creatorcontrib><creatorcontrib>Hedin, Eva-Maria</creatorcontrib><creatorcontrib>Hedenstierna, Göran</creatorcontrib><creatorcontrib>Sveriges lantbruksuniversitet</creatorcontrib><title>Case Studies in Physiology: Ventilation and perfusion in a giraffe-does size matter?</title><title>Journal of applied physiology (1985)</title><addtitle>J Appl Physiol (1985)</addtitle><description>The trachea in the giraffe is long but narrow, and dead space ventilation is considered to be of approximately the same size as in other mammals. Less is known about the matching between ventilation and lung blood flow. The lungs in the giraffe are large, up to 1 m high and 0.7 m wide, and this may cause considerable ventilation/perfusion (V
/Q) mismatch due to the influence of gravitational forces, which could lead to hypoxemia. We studied a young giraffe under anesthesia using the multiple inert gas elimination technique to analyze the VA/Q distribution and arterial oxygenation and compared the results with those obtained in other species of different sizes, including humans. V
/Q distribution was broad but unimodal, and the shunt of blood flow through nonventilated lung regions was essentially absent, suggesting no lung collapse. The V
/Q match was as good as in the similarly sized horse and was even comparable to that in smaller sized animals, including rabbit and rat. The match was also similar to that in anesthetized humans. Arterial oxygenation was essentially similar in all studied species. The findings suggest that the efficiency of V
/Q matching is independent of lung size in the studied mammals that vary in weight from less than 1 to more than 400 kg.</description><subject>Animals</subject><subject>Clinical Science</subject><subject>Female</subject><subject>gas exchange</subject><subject>giraffe</subject><subject>Giraffes - physiology</subject><subject>Horses</subject><subject>Humans</subject><subject>Klinisk vetenskap</subject><subject>Lung - physiology</subject><subject>Pulmonary Gas Exchange - physiology</subject><subject>Pulmonary Ventilation - physiology</subject><subject>Rabbits</subject><subject>Rats</subject><subject>Regional Blood Flow - physiology</subject><subject>Respiration</subject><subject>ventilation</subject><subject>Ventilation-Perfusion Ratio - physiology</subject><subject>ventilation/perfusion</subject><issn>8750-7587</issn><issn>1522-1601</issn><issn>1522-1601</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kc1O3DAURi0EKlPaV4AsWZDBf7EzbBAaSouERKVSttZNfDMYZeJgx6qGpydhAHXD6sry-T5f-RByxOicsYKfPkLft_3DJjrfzimVvJxzytQOmY23PGeKsl0yK3VBc12Uep98jfGRUiZlwb6Qfa6VonxRzsjdEiJmf4ZkHcbMddnvbalfbc6ye-wG18LgfJdBZ7MeQ5PidBpByFYuQNNgbv0Yje4ZszUMA4bzb2SvgTbi97d5QP5e_bhb_spvbn9eLy9u8loKPeScWw0LajnqigmrF7KRRa0KrphkDUjLQYMUi7LgTDSWSVQAigoldVFXgooDkm974z_sU2X64NYQNsaDM7FNFYRpmIimlFTrkT_5lL909xfGh5VJyQimxo8a8eMt3gf_lDAOZu1ijW0LHfoUDRsX07rUdNpEb9E6-BgDNh_djJrJmPnfmHk1ZiZjY_Lw7ZFUrdF-5N4ViRcjuJZA</recordid><startdate>20161201</startdate><enddate>20161201</enddate><creator>Nyman, Görel</creator><creator>Röken, Bengt</creator><creator>Hedin, Eva-Maria</creator><creator>Hedenstierna, Göran</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>ADTPV</scope><scope>AOWAS</scope><scope>DF2</scope></search><sort><creationdate>20161201</creationdate><title>Case Studies in Physiology: Ventilation and perfusion in a giraffe-does size matter?</title><author>Nyman, Görel ; Röken, Bengt ; Hedin, Eva-Maria ; Hedenstierna, Göran</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c437t-22d7a90d2e7b13d794f45c6526141fa4d2a7a43985213fd14e6aa6036475cb303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Animals</topic><topic>Clinical Science</topic><topic>Female</topic><topic>gas exchange</topic><topic>giraffe</topic><topic>Giraffes - physiology</topic><topic>Horses</topic><topic>Humans</topic><topic>Klinisk vetenskap</topic><topic>Lung - physiology</topic><topic>Pulmonary Gas Exchange - physiology</topic><topic>Pulmonary Ventilation - physiology</topic><topic>Rabbits</topic><topic>Rats</topic><topic>Regional Blood Flow - physiology</topic><topic>Respiration</topic><topic>ventilation</topic><topic>Ventilation-Perfusion Ratio - physiology</topic><topic>ventilation/perfusion</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nyman, Görel</creatorcontrib><creatorcontrib>Röken, Bengt</creatorcontrib><creatorcontrib>Hedin, Eva-Maria</creatorcontrib><creatorcontrib>Hedenstierna, Göran</creatorcontrib><creatorcontrib>Sveriges lantbruksuniversitet</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>SwePub</collection><collection>SwePub Articles</collection><collection>SWEPUB Uppsala universitet</collection><jtitle>Journal of applied physiology (1985)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nyman, Görel</au><au>Röken, Bengt</au><au>Hedin, Eva-Maria</au><au>Hedenstierna, Göran</au><aucorp>Sveriges lantbruksuniversitet</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Case Studies in Physiology: Ventilation and perfusion in a giraffe-does size matter?</atitle><jtitle>Journal of applied physiology (1985)</jtitle><addtitle>J Appl Physiol (1985)</addtitle><date>2016-12-01</date><risdate>2016</risdate><volume>121</volume><issue>6</issue><spage>1374</spage><epage>1378</epage><pages>1374-1378</pages><issn>8750-7587</issn><issn>1522-1601</issn><eissn>1522-1601</eissn><abstract>The trachea in the giraffe is long but narrow, and dead space ventilation is considered to be of approximately the same size as in other mammals. Less is known about the matching between ventilation and lung blood flow. The lungs in the giraffe are large, up to 1 m high and 0.7 m wide, and this may cause considerable ventilation/perfusion (V
/Q) mismatch due to the influence of gravitational forces, which could lead to hypoxemia. We studied a young giraffe under anesthesia using the multiple inert gas elimination technique to analyze the VA/Q distribution and arterial oxygenation and compared the results with those obtained in other species of different sizes, including humans. V
/Q distribution was broad but unimodal, and the shunt of blood flow through nonventilated lung regions was essentially absent, suggesting no lung collapse. The V
/Q match was as good as in the similarly sized horse and was even comparable to that in smaller sized animals, including rabbit and rat. The match was also similar to that in anesthetized humans. Arterial oxygenation was essentially similar in all studied species. The findings suggest that the efficiency of V
/Q matching is independent of lung size in the studied mammals that vary in weight from less than 1 to more than 400 kg.</abstract><cop>United States</cop><pmid>27660298</pmid><doi>10.1152/japplphysiol.00428.2016</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 8750-7587 |
ispartof | Journal of applied physiology (1985), 2016-12, Vol.121 (6), p.1374-1378 |
issn | 8750-7587 1522-1601 1522-1601 |
language | eng |
recordid | cdi_swepub_primary_oai_slubar_slu_se_84077 |
source | MEDLINE; American Physiological Society; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection |
subjects | Animals Clinical Science Female gas exchange giraffe Giraffes - physiology Horses Humans Klinisk vetenskap Lung - physiology Pulmonary Gas Exchange - physiology Pulmonary Ventilation - physiology Rabbits Rats Regional Blood Flow - physiology Respiration ventilation Ventilation-Perfusion Ratio - physiology ventilation/perfusion |
title | Case Studies in Physiology: Ventilation and perfusion in a giraffe-does size matter? |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T13%3A28%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_swepu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Case%20Studies%20in%20Physiology:%20Ventilation%20and%20perfusion%20in%20a%20giraffe-does%20size%20matter?&rft.jtitle=Journal%20of%20applied%20physiology%20(1985)&rft.au=Nyman,%20G%C3%B6rel&rft.aucorp=Sveriges%20lantbruksuniversitet&rft.date=2016-12-01&rft.volume=121&rft.issue=6&rft.spage=1374&rft.epage=1378&rft.pages=1374-1378&rft.issn=8750-7587&rft.eissn=1522-1601&rft_id=info:doi/10.1152/japplphysiol.00428.2016&rft_dat=%3Cproquest_swepu%3E1852778700%3C/proquest_swepu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1852778700&rft_id=info:pmid/27660298&rfr_iscdi=true |