Estimation of intraoperative brain surface movement

It is becoming increasingly common for surgical navigation systems to be used intraoperatively to enable the surgeon to ascertain his or her position within the patient with respect to features in registered preoperative images. These systems assume that the skull and its contents behave as a rigid...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hill, Derek L. G., Maurer, Calvin R., Wang, Matthew Y., Maciunas, Robert J., Barwise, John A., Fitzpatrick, J. Michael
Format: Buchkapitel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 458
container_issue
container_start_page 449
container_title
container_volume
creator Hill, Derek L. G.
Maurer, Calvin R.
Wang, Matthew Y.
Maciunas, Robert J.
Barwise, John A.
Fitzpatrick, J. Michael
description It is becoming increasingly common for surgical navigation systems to be used intraoperatively to enable the surgeon to ascertain his or her position within the patient with respect to features in registered preoperative images. These systems assume that the skull and its contents behave as a rigid body between imaging and surgery, and during surgery. We have used the ACUSTAR I surgical navigation system to measure shifts in the brain surface relative to the skull between imaging and surgery on five patients. The preoperative images are registered to the coordinates of the surgical localizer using four fiducial markers screwed into the outer table of the skull. The brain surface is delineated from preoperative MR images, and the distance between this surface and brain surface points recorded intraoperatively is calculated. The median shift of points on the brain surface ranged from 0.3 mm to 7.4 mm. In all cases, the direction of this shift corresponds to a “sinking” of the brain intraoperatively compared to its preoperative position. We consider possible changes in CNS volume that might account for these shifts.
doi_str_mv 10.1007/BFb0029267
format Book Chapter
fullrecord <record><control><sourceid>springer</sourceid><recordid>TN_cdi_springer_books_10_1007_BFb0029267</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>springer_books_10_1007_BFb0029267</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1447-bf6be45e94a196aae7e15add1f650df59c434ad591e522983507d11d42d016b03</originalsourceid><addsrcrecordid>eNpFkD1PwzAURc2XRChd-AUZWQLv2c92PELVAlIlFpgjO7ZRgMaVHfr7KWol7nKle6Q7HMZuEO4QQN8_rhwAN1zpE3YlJIFqyRhzyipUiI0QZM6OgGtBcM4qEMAbo0lcsnkpn7CP4JywrZhYlmnY2GlIY51iPYxTtmkb8n7ZhdplO4x1-cnR9qHepF3YhHG6ZhfRfpcwP_aMva-Wb4vnZv369LJ4WDc9EunGReUCyWDIolHWBh1QWu8xKgk-StOTIOulwSA5N62QoD2iJ-4BlQMxY7eH37LNw_gRcudS-iodQvdnovs3IX4BU1JLIQ</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>book_chapter</recordtype></control><display><type>book_chapter</type><title>Estimation of intraoperative brain surface movement</title><source>Springer Books</source><creator>Hill, Derek L. G. ; Maurer, Calvin R. ; Wang, Matthew Y. ; Maciunas, Robert J. ; Barwise, John A. ; Fitzpatrick, J. Michael</creator><contributor>Grimson, Eric ; Troccaz, Jocelyne ; Mösges, Ralph</contributor><creatorcontrib>Hill, Derek L. G. ; Maurer, Calvin R. ; Wang, Matthew Y. ; Maciunas, Robert J. ; Barwise, John A. ; Fitzpatrick, J. Michael ; Grimson, Eric ; Troccaz, Jocelyne ; Mösges, Ralph</creatorcontrib><description>It is becoming increasingly common for surgical navigation systems to be used intraoperatively to enable the surgeon to ascertain his or her position within the patient with respect to features in registered preoperative images. These systems assume that the skull and its contents behave as a rigid body between imaging and surgery, and during surgery. We have used the ACUSTAR I surgical navigation system to measure shifts in the brain surface relative to the skull between imaging and surgery on five patients. The preoperative images are registered to the coordinates of the surgical localizer using four fiducial markers screwed into the outer table of the skull. The brain surface is delineated from preoperative MR images, and the distance between this surface and brain surface points recorded intraoperatively is calculated. The median shift of points on the brain surface ranged from 0.3 mm to 7.4 mm. In all cases, the direction of this shift corresponds to a “sinking” of the brain intraoperatively compared to its preoperative position. We consider possible changes in CNS volume that might account for these shifts.</description><identifier>ISSN: 0302-9743</identifier><identifier>ISBN: 3540627340</identifier><identifier>ISBN: 9783540627340</identifier><identifier>EISSN: 1611-3349</identifier><identifier>EISBN: 3540684999</identifier><identifier>EISBN: 9783540684992</identifier><identifier>DOI: 10.1007/BFb0029267</identifier><language>eng</language><publisher>Berlin, Heidelberg: Springer Berlin Heidelberg</publisher><subject>Brain Shift ; Brain Surface ; Fiducial Marker ; Normal Pressure Hydrocephalus ; Target Registration Error</subject><ispartof>CVRMed-MRCAS'97, 2005, p.449-458</ispartof><rights>Springer-Verlag Berlin Heidelberg 1997</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1447-bf6be45e94a196aae7e15add1f650df59c434ad591e522983507d11d42d016b03</citedby><relation>Lecture Notes in Computer Science</relation></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/BFb0029267$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/BFb0029267$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>775,776,780,789,27904,38234,41421,42490</link.rule.ids></links><search><contributor>Grimson, Eric</contributor><contributor>Troccaz, Jocelyne</contributor><contributor>Mösges, Ralph</contributor><creatorcontrib>Hill, Derek L. G.</creatorcontrib><creatorcontrib>Maurer, Calvin R.</creatorcontrib><creatorcontrib>Wang, Matthew Y.</creatorcontrib><creatorcontrib>Maciunas, Robert J.</creatorcontrib><creatorcontrib>Barwise, John A.</creatorcontrib><creatorcontrib>Fitzpatrick, J. Michael</creatorcontrib><title>Estimation of intraoperative brain surface movement</title><title>CVRMed-MRCAS'97</title><description>It is becoming increasingly common for surgical navigation systems to be used intraoperatively to enable the surgeon to ascertain his or her position within the patient with respect to features in registered preoperative images. These systems assume that the skull and its contents behave as a rigid body between imaging and surgery, and during surgery. We have used the ACUSTAR I surgical navigation system to measure shifts in the brain surface relative to the skull between imaging and surgery on five patients. The preoperative images are registered to the coordinates of the surgical localizer using four fiducial markers screwed into the outer table of the skull. The brain surface is delineated from preoperative MR images, and the distance between this surface and brain surface points recorded intraoperatively is calculated. The median shift of points on the brain surface ranged from 0.3 mm to 7.4 mm. In all cases, the direction of this shift corresponds to a “sinking” of the brain intraoperatively compared to its preoperative position. We consider possible changes in CNS volume that might account for these shifts.</description><subject>Brain Shift</subject><subject>Brain Surface</subject><subject>Fiducial Marker</subject><subject>Normal Pressure Hydrocephalus</subject><subject>Target Registration Error</subject><issn>0302-9743</issn><issn>1611-3349</issn><isbn>3540627340</isbn><isbn>9783540627340</isbn><isbn>3540684999</isbn><isbn>9783540684992</isbn><fulltext>true</fulltext><rsrctype>book_chapter</rsrctype><creationdate>2005</creationdate><recordtype>book_chapter</recordtype><sourceid/><recordid>eNpFkD1PwzAURc2XRChd-AUZWQLv2c92PELVAlIlFpgjO7ZRgMaVHfr7KWol7nKle6Q7HMZuEO4QQN8_rhwAN1zpE3YlJIFqyRhzyipUiI0QZM6OgGtBcM4qEMAbo0lcsnkpn7CP4JywrZhYlmnY2GlIY51iPYxTtmkb8n7ZhdplO4x1-cnR9qHepF3YhHG6ZhfRfpcwP_aMva-Wb4vnZv369LJ4WDc9EunGReUCyWDIolHWBh1QWu8xKgk-StOTIOulwSA5N62QoD2iJ-4BlQMxY7eH37LNw_gRcudS-iodQvdnovs3IX4BU1JLIQ</recordid><startdate>20051121</startdate><enddate>20051121</enddate><creator>Hill, Derek L. G.</creator><creator>Maurer, Calvin R.</creator><creator>Wang, Matthew Y.</creator><creator>Maciunas, Robert J.</creator><creator>Barwise, John A.</creator><creator>Fitzpatrick, J. Michael</creator><general>Springer Berlin Heidelberg</general><scope/></search><sort><creationdate>20051121</creationdate><title>Estimation of intraoperative brain surface movement</title><author>Hill, Derek L. G. ; Maurer, Calvin R. ; Wang, Matthew Y. ; Maciunas, Robert J. ; Barwise, John A. ; Fitzpatrick, J. Michael</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1447-bf6be45e94a196aae7e15add1f650df59c434ad591e522983507d11d42d016b03</frbrgroupid><rsrctype>book_chapters</rsrctype><prefilter>book_chapters</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Brain Shift</topic><topic>Brain Surface</topic><topic>Fiducial Marker</topic><topic>Normal Pressure Hydrocephalus</topic><topic>Target Registration Error</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hill, Derek L. G.</creatorcontrib><creatorcontrib>Maurer, Calvin R.</creatorcontrib><creatorcontrib>Wang, Matthew Y.</creatorcontrib><creatorcontrib>Maciunas, Robert J.</creatorcontrib><creatorcontrib>Barwise, John A.</creatorcontrib><creatorcontrib>Fitzpatrick, J. Michael</creatorcontrib></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hill, Derek L. G.</au><au>Maurer, Calvin R.</au><au>Wang, Matthew Y.</au><au>Maciunas, Robert J.</au><au>Barwise, John A.</au><au>Fitzpatrick, J. Michael</au><au>Grimson, Eric</au><au>Troccaz, Jocelyne</au><au>Mösges, Ralph</au><format>book</format><genre>bookitem</genre><ristype>CHAP</ristype><atitle>Estimation of intraoperative brain surface movement</atitle><btitle>CVRMed-MRCAS'97</btitle><seriestitle>Lecture Notes in Computer Science</seriestitle><date>2005-11-21</date><risdate>2005</risdate><spage>449</spage><epage>458</epage><pages>449-458</pages><issn>0302-9743</issn><eissn>1611-3349</eissn><isbn>3540627340</isbn><isbn>9783540627340</isbn><eisbn>3540684999</eisbn><eisbn>9783540684992</eisbn><abstract>It is becoming increasingly common for surgical navigation systems to be used intraoperatively to enable the surgeon to ascertain his or her position within the patient with respect to features in registered preoperative images. These systems assume that the skull and its contents behave as a rigid body between imaging and surgery, and during surgery. We have used the ACUSTAR I surgical navigation system to measure shifts in the brain surface relative to the skull between imaging and surgery on five patients. The preoperative images are registered to the coordinates of the surgical localizer using four fiducial markers screwed into the outer table of the skull. The brain surface is delineated from preoperative MR images, and the distance between this surface and brain surface points recorded intraoperatively is calculated. The median shift of points on the brain surface ranged from 0.3 mm to 7.4 mm. In all cases, the direction of this shift corresponds to a “sinking” of the brain intraoperatively compared to its preoperative position. We consider possible changes in CNS volume that might account for these shifts.</abstract><cop>Berlin, Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><doi>10.1007/BFb0029267</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0302-9743
ispartof CVRMed-MRCAS'97, 2005, p.449-458
issn 0302-9743
1611-3349
language eng
recordid cdi_springer_books_10_1007_BFb0029267
source Springer Books
subjects Brain Shift
Brain Surface
Fiducial Marker
Normal Pressure Hydrocephalus
Target Registration Error
title Estimation of intraoperative brain surface movement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T10%3A58%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-springer&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=bookitem&rft.atitle=Estimation%20of%20intraoperative%20brain%20surface%20movement&rft.btitle=CVRMed-MRCAS'97&rft.au=Hill,%20Derek%20L.%20G.&rft.date=2005-11-21&rft.spage=449&rft.epage=458&rft.pages=449-458&rft.issn=0302-9743&rft.eissn=1611-3349&rft.isbn=3540627340&rft.isbn_list=9783540627340&rft_id=info:doi/10.1007/BFb0029267&rft_dat=%3Cspringer%3Espringer_books_10_1007_BFb0029267%3C/springer%3E%3Curl%3E%3C/url%3E&rft.eisbn=3540684999&rft.eisbn_list=9783540684992&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true