Laser-based comparison calibration of laboratory standard microphones

Laboratory standard microphones, which have characteristics that are specified in international and U.S. national standards, are condenser microphones used for highly accurate sound pressure measurements and calibrations. A precision laser-based comparison calibration method for these microphones is...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 2021-04, Vol.149 (4), p.A95-A95
Hauptverfasser: Wagner, Randall, Allen, Richard A., Dong, Qian
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page A95
container_issue 4
container_start_page A95
container_title The Journal of the Acoustical Society of America
container_volume 149
creator Wagner, Randall
Allen, Richard A.
Dong, Qian
description Laboratory standard microphones, which have characteristics that are specified in international and U.S. national standards, are condenser microphones used for highly accurate sound pressure measurements and calibrations. A precision laser-based comparison calibration method for these microphones is described. This method uses laboratory standard microphones calibrated by the pressure reciprocity method as transfer standards, or reference microphones, to calibrate other laboratory standard microphones, or test microphones. Electrical drive current and microphone diaphragm velocity are measured while the microphones are driven as transmitters/sources of sound; the microphone diaphragm velocity is measured using scanning laser-Doppler vibrometry. The reference and test microphones are measured consecutively. Sensitivities determined using this method display very good agreement with those determined directly by the pressure reciprocity method for seven such test microphones at 250 Hz and 1000 Hz. At these frequencies of calibration, the expanded (coverage factor, k = 2) uncertainties of this comparison calibration method for these microphones are ±0.05 dB at both frequencies. These expanded uncertainties compare favorably to those of the reciprocity-based comparison calibration service done with a large-volume acoustic coupler at the National Institute of Standards and Technology, which are ±0.08 dB at 250 Hz and 1000 Hz.
doi_str_mv 10.1121/10.0004624
format Article
fullrecord <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_scitation_primary_10_1121_10_0004624</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>jasa</sourcerecordid><originalsourceid>FETCH-LOGICAL-c714-d5259401834c573851dfa782aed2d5d6dde12671cfa719c8186859c64ee8bb6b3</originalsourceid><addsrcrecordid>eNp9j09LxDAQxYMoWFcvfoKelWgmTdLkKMu6CgUvey_5V4y0TUl62W9v1t2zl3nzHo8Zfgg9AnkBoPBalBDCBGVXqAJOCZacsmtUlRQwU0Lcorucf4rlslEV2nU6-4RNma62cVp0CjnOtdVjMEmvoexxqEdtYnExHeu86tnp5Oop2BSX7zj7fI9uBj1m_3DRDTq87w7bD9x97T-3bx22LTDsOOWKEZANs7xtJAc36FZS7R113AnnPFDRgi0pKCtBCsmVFcx7aYwwzQY9nc-WxzknP_RLCpNOxx5If-I_6YW_lJ_P5WzD-gfyX_sXb2Za2Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Laser-based comparison calibration of laboratory standard microphones</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><source>AIP Acoustical Society of America</source><creator>Wagner, Randall ; Allen, Richard A. ; Dong, Qian</creator><creatorcontrib>Wagner, Randall ; Allen, Richard A. ; Dong, Qian</creatorcontrib><description>Laboratory standard microphones, which have characteristics that are specified in international and U.S. national standards, are condenser microphones used for highly accurate sound pressure measurements and calibrations. A precision laser-based comparison calibration method for these microphones is described. This method uses laboratory standard microphones calibrated by the pressure reciprocity method as transfer standards, or reference microphones, to calibrate other laboratory standard microphones, or test microphones. Electrical drive current and microphone diaphragm velocity are measured while the microphones are driven as transmitters/sources of sound; the microphone diaphragm velocity is measured using scanning laser-Doppler vibrometry. The reference and test microphones are measured consecutively. Sensitivities determined using this method display very good agreement with those determined directly by the pressure reciprocity method for seven such test microphones at 250 Hz and 1000 Hz. At these frequencies of calibration, the expanded (coverage factor, k = 2) uncertainties of this comparison calibration method for these microphones are ±0.05 dB at both frequencies. These expanded uncertainties compare favorably to those of the reciprocity-based comparison calibration service done with a large-volume acoustic coupler at the National Institute of Standards and Technology, which are ±0.08 dB at 250 Hz and 1000 Hz.</description><identifier>ISSN: 0001-4966</identifier><identifier>EISSN: 1520-8524</identifier><identifier>DOI: 10.1121/10.0004624</identifier><identifier>CODEN: JASMAN</identifier><language>eng</language><ispartof>The Journal of the Acoustical Society of America, 2021-04, Vol.149 (4), p.A95-A95</ispartof><rights>Acoustical Society of America</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/jasa/article-lookup/doi/10.1121/10.0004624$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>207,208,314,776,780,790,1559,4498,27901,27902,76127</link.rule.ids></links><search><creatorcontrib>Wagner, Randall</creatorcontrib><creatorcontrib>Allen, Richard A.</creatorcontrib><creatorcontrib>Dong, Qian</creatorcontrib><title>Laser-based comparison calibration of laboratory standard microphones</title><title>The Journal of the Acoustical Society of America</title><description>Laboratory standard microphones, which have characteristics that are specified in international and U.S. national standards, are condenser microphones used for highly accurate sound pressure measurements and calibrations. A precision laser-based comparison calibration method for these microphones is described. This method uses laboratory standard microphones calibrated by the pressure reciprocity method as transfer standards, or reference microphones, to calibrate other laboratory standard microphones, or test microphones. Electrical drive current and microphone diaphragm velocity are measured while the microphones are driven as transmitters/sources of sound; the microphone diaphragm velocity is measured using scanning laser-Doppler vibrometry. The reference and test microphones are measured consecutively. Sensitivities determined using this method display very good agreement with those determined directly by the pressure reciprocity method for seven such test microphones at 250 Hz and 1000 Hz. At these frequencies of calibration, the expanded (coverage factor, k = 2) uncertainties of this comparison calibration method for these microphones are ±0.05 dB at both frequencies. These expanded uncertainties compare favorably to those of the reciprocity-based comparison calibration service done with a large-volume acoustic coupler at the National Institute of Standards and Technology, which are ±0.08 dB at 250 Hz and 1000 Hz.</description><issn>0001-4966</issn><issn>1520-8524</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9j09LxDAQxYMoWFcvfoKelWgmTdLkKMu6CgUvey_5V4y0TUl62W9v1t2zl3nzHo8Zfgg9AnkBoPBalBDCBGVXqAJOCZacsmtUlRQwU0Lcorucf4rlslEV2nU6-4RNma62cVp0CjnOtdVjMEmvoexxqEdtYnExHeu86tnp5Oop2BSX7zj7fI9uBj1m_3DRDTq87w7bD9x97T-3bx22LTDsOOWKEZANs7xtJAc36FZS7R113AnnPFDRgi0pKCtBCsmVFcx7aYwwzQY9nc-WxzknP_RLCpNOxx5If-I_6YW_lJ_P5WzD-gfyX_sXb2Za2Q</recordid><startdate>202104</startdate><enddate>202104</enddate><creator>Wagner, Randall</creator><creator>Allen, Richard A.</creator><creator>Dong, Qian</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>202104</creationdate><title>Laser-based comparison calibration of laboratory standard microphones</title><author>Wagner, Randall ; Allen, Richard A. ; Dong, Qian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c714-d5259401834c573851dfa782aed2d5d6dde12671cfa719c8186859c64ee8bb6b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wagner, Randall</creatorcontrib><creatorcontrib>Allen, Richard A.</creatorcontrib><creatorcontrib>Dong, Qian</creatorcontrib><collection>CrossRef</collection><jtitle>The Journal of the Acoustical Society of America</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wagner, Randall</au><au>Allen, Richard A.</au><au>Dong, Qian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Laser-based comparison calibration of laboratory standard microphones</atitle><jtitle>The Journal of the Acoustical Society of America</jtitle><date>2021-04</date><risdate>2021</risdate><volume>149</volume><issue>4</issue><spage>A95</spage><epage>A95</epage><pages>A95-A95</pages><issn>0001-4966</issn><eissn>1520-8524</eissn><coden>JASMAN</coden><abstract>Laboratory standard microphones, which have characteristics that are specified in international and U.S. national standards, are condenser microphones used for highly accurate sound pressure measurements and calibrations. A precision laser-based comparison calibration method for these microphones is described. This method uses laboratory standard microphones calibrated by the pressure reciprocity method as transfer standards, or reference microphones, to calibrate other laboratory standard microphones, or test microphones. Electrical drive current and microphone diaphragm velocity are measured while the microphones are driven as transmitters/sources of sound; the microphone diaphragm velocity is measured using scanning laser-Doppler vibrometry. The reference and test microphones are measured consecutively. Sensitivities determined using this method display very good agreement with those determined directly by the pressure reciprocity method for seven such test microphones at 250 Hz and 1000 Hz. At these frequencies of calibration, the expanded (coverage factor, k = 2) uncertainties of this comparison calibration method for these microphones are ±0.05 dB at both frequencies. These expanded uncertainties compare favorably to those of the reciprocity-based comparison calibration service done with a large-volume acoustic coupler at the National Institute of Standards and Technology, which are ±0.08 dB at 250 Hz and 1000 Hz.</abstract><doi>10.1121/10.0004624</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0001-4966
ispartof The Journal of the Acoustical Society of America, 2021-04, Vol.149 (4), p.A95-A95
issn 0001-4966
1520-8524
language eng
recordid cdi_scitation_primary_10_1121_10_0004624
source AIP Journals Complete; Alma/SFX Local Collection; AIP Acoustical Society of America
title Laser-based comparison calibration of laboratory standard microphones
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T22%3A04%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Laser-based%20comparison%20calibration%20of%20laboratory%20standard%20microphones&rft.jtitle=The%20Journal%20of%20the%20Acoustical%20Society%20of%20America&rft.au=Wagner,%20Randall&rft.date=2021-04&rft.volume=149&rft.issue=4&rft.spage=A95&rft.epage=A95&rft.pages=A95-A95&rft.issn=0001-4966&rft.eissn=1520-8524&rft.coden=JASMAN&rft_id=info:doi/10.1121/10.0004624&rft_dat=%3Cscitation_cross%3Ejasa%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true