SU-D-BRA-06: Duodenal Interfraction Motion with Abdominal Compression

Purpose: To quantify the effect of abdominal compression on duodenal motion during pancreatic radiotherapy. Methods: Seven patients treated for pancreatic cancer were selected for analysis. Four patients were treated with abdominal compression and three without. The duodenum was contoured by the sam...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical physics (Lancaster) 2016-06, Vol.43 (6), p.3340-3340
Hauptverfasser: Witztum, A, Holyoake, D, Warren, S, Partridge, M, Hawkins, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3340
container_issue 6
container_start_page 3340
container_title Medical physics (Lancaster)
container_volume 43
creator Witztum, A
Holyoake, D
Warren, S
Partridge, M
Hawkins, M
description Purpose: To quantify the effect of abdominal compression on duodenal motion during pancreatic radiotherapy. Methods: Seven patients treated for pancreatic cancer were selected for analysis. Four patients were treated with abdominal compression and three without. The duodenum was contoured by the same physician on each CBCT (five CBCTs for patients with compression, four for non-compression patients). CBCTs were rigidly registered using a soft tissue match and contours were copied to the delivered plans which were all radical (BED > 50 Gy). The distance between the duodenum on the planning CT and each CBCT was quantified by calculating the root mean square (RMS) distance. The DVHs of each abdominal compression patient was converted to an EQD2 DVH (alpha/beta = 10) using an in-house tool and volumes receiving at least 25, 35, 45, and 50 Gy were recorded. Results: The maximum variation in duodenal volumes on the CBCTs for the four abdominal compression patients were 19.1 cm3 (32.8%), 19.1 cm3 (20.6%), 19.9 cm3 (14.3%), and 12.9 cm3 (27.3%) compared to 15.2 cm3 (17.6%), 34.7 cm3 (83.4%), and 56 cm3 (60.2%) for non-compression patients. The average RMS distance between the duodenum on the planning CT and each CBCT for all abdominal compression patients was 0.3 cm compared to 0.7 cm for non-compressed patients. The largest (and average) difference between the planning CT and CBCTs in volume of duodenum receiving more than 25, 35, 45 and 50 Gy for abdominal compression patients was 11% (5%), 9% (3%), 9% (2%), and 6% (1%). Conclusion: Abdominal compression reduces variation in volume and absolute position of the duodenum throughout treatment. This is seen as an improvement but does not eliminate the need to consider dosimetric effects of motion. Abdominal compression is particularly useful in SBRT when only a few fractions are delivered. Alon Witztum is supported by an MRC/Gray Institute DPhil Studentship. Daniel Holyoake is supported by a CRUK/Nuffield Clinical Research Fellowship. Sam Warren and Mike Partridge are supported by CRUK grant C5255/A15935. Maria Hawkins received an MRC Fellowship MC_PC_12001/2.
doi_str_mv 10.1118/1.4955639
format Article
fullrecord <record><control><sourceid>wiley_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1118_1_4955639</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MP5639</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1709-bd5dcc3f60300bcf814aab100d83543b4772683efd2c8cf68d9575d6512887fb3</originalsourceid><addsrcrecordid>eNp90EtLw0AUBeBBFKzVhf8g4Eph6p1nJu5qWrXQoqhdD8k8aKTNlEyk9N_bmG51dRb341w4CF0TGBFC1D0Z8UwIybITNKA8ZZhTyE7RACDjmHIQ5-gixi8AkEzAAE0_lniCH9_HGORDMvkO1tXFOpnVrWt8U5i2CnWyCL-xq9pVMi5t2FSdycNm27gYD6dLdOaLdXRXxxyi5dP0M3_B89fnWT6eY0NSyHBphTWGeQkMoDReEV4UJQGwignOSp6mVCrmvKVGGS-VzUQqrBSEKpX6kg3RTd8bYlvpaKrWmZUJde1MqymVlDMlD-q2V6YJMTbO621TbYpmrwnobiVN9HGlg8W93VVrt_8b6sXb0d_1vntedLP8U_4DVG9ySA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>SU-D-BRA-06: Duodenal Interfraction Motion with Abdominal Compression</title><source>Wiley Journals</source><source>Alma/SFX Local Collection</source><creator>Witztum, A ; Holyoake, D ; Warren, S ; Partridge, M ; Hawkins, M</creator><creatorcontrib>Witztum, A ; Holyoake, D ; Warren, S ; Partridge, M ; Hawkins, M</creatorcontrib><description>Purpose: To quantify the effect of abdominal compression on duodenal motion during pancreatic radiotherapy. Methods: Seven patients treated for pancreatic cancer were selected for analysis. Four patients were treated with abdominal compression and three without. The duodenum was contoured by the same physician on each CBCT (five CBCTs for patients with compression, four for non-compression patients). CBCTs were rigidly registered using a soft tissue match and contours were copied to the delivered plans which were all radical (BED &gt; 50 Gy). The distance between the duodenum on the planning CT and each CBCT was quantified by calculating the root mean square (RMS) distance. The DVHs of each abdominal compression patient was converted to an EQD2 DVH (alpha/beta = 10) using an in-house tool and volumes receiving at least 25, 35, 45, and 50 Gy were recorded. Results: The maximum variation in duodenal volumes on the CBCTs for the four abdominal compression patients were 19.1 cm3 (32.8%), 19.1 cm3 (20.6%), 19.9 cm3 (14.3%), and 12.9 cm3 (27.3%) compared to 15.2 cm3 (17.6%), 34.7 cm3 (83.4%), and 56 cm3 (60.2%) for non-compression patients. The average RMS distance between the duodenum on the planning CT and each CBCT for all abdominal compression patients was 0.3 cm compared to 0.7 cm for non-compressed patients. The largest (and average) difference between the planning CT and CBCTs in volume of duodenum receiving more than 25, 35, 45 and 50 Gy for abdominal compression patients was 11% (5%), 9% (3%), 9% (2%), and 6% (1%). Conclusion: Abdominal compression reduces variation in volume and absolute position of the duodenum throughout treatment. This is seen as an improvement but does not eliminate the need to consider dosimetric effects of motion. Abdominal compression is particularly useful in SBRT when only a few fractions are delivered. Alon Witztum is supported by an MRC/Gray Institute DPhil Studentship. Daniel Holyoake is supported by a CRUK/Nuffield Clinical Research Fellowship. Sam Warren and Mike Partridge are supported by CRUK grant C5255/A15935. Maria Hawkins received an MRC Fellowship MC_PC_12001/2.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.4955639</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>United States: American Association of Physicists in Medicine</publisher><subject>60 APPLIED LIFE SCIENCES ; ANIMAL TISSUES ; Cancer ; COMPRESSION ; COMPUTERIZED TOMOGRAPHY ; Cone beam computed tomography ; Fellowships ; NEOPLASMS ; PANCREAS ; PATIENTS ; PLANNING ; RADIATION PROTECTION AND DOSIMETRY ; Radiation therapy ; RADIOTHERAPY ; SMALL INTESTINE ; Tissues</subject><ispartof>Medical physics (Lancaster), 2016-06, Vol.43 (6), p.3340-3340</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2016 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.4955639$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>230,314,780,784,885,1417,27924,27925,45575</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/22624386$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Witztum, A</creatorcontrib><creatorcontrib>Holyoake, D</creatorcontrib><creatorcontrib>Warren, S</creatorcontrib><creatorcontrib>Partridge, M</creatorcontrib><creatorcontrib>Hawkins, M</creatorcontrib><title>SU-D-BRA-06: Duodenal Interfraction Motion with Abdominal Compression</title><title>Medical physics (Lancaster)</title><description>Purpose: To quantify the effect of abdominal compression on duodenal motion during pancreatic radiotherapy. Methods: Seven patients treated for pancreatic cancer were selected for analysis. Four patients were treated with abdominal compression and three without. The duodenum was contoured by the same physician on each CBCT (five CBCTs for patients with compression, four for non-compression patients). CBCTs were rigidly registered using a soft tissue match and contours were copied to the delivered plans which were all radical (BED &gt; 50 Gy). The distance between the duodenum on the planning CT and each CBCT was quantified by calculating the root mean square (RMS) distance. The DVHs of each abdominal compression patient was converted to an EQD2 DVH (alpha/beta = 10) using an in-house tool and volumes receiving at least 25, 35, 45, and 50 Gy were recorded. Results: The maximum variation in duodenal volumes on the CBCTs for the four abdominal compression patients were 19.1 cm3 (32.8%), 19.1 cm3 (20.6%), 19.9 cm3 (14.3%), and 12.9 cm3 (27.3%) compared to 15.2 cm3 (17.6%), 34.7 cm3 (83.4%), and 56 cm3 (60.2%) for non-compression patients. The average RMS distance between the duodenum on the planning CT and each CBCT for all abdominal compression patients was 0.3 cm compared to 0.7 cm for non-compressed patients. The largest (and average) difference between the planning CT and CBCTs in volume of duodenum receiving more than 25, 35, 45 and 50 Gy for abdominal compression patients was 11% (5%), 9% (3%), 9% (2%), and 6% (1%). Conclusion: Abdominal compression reduces variation in volume and absolute position of the duodenum throughout treatment. This is seen as an improvement but does not eliminate the need to consider dosimetric effects of motion. Abdominal compression is particularly useful in SBRT when only a few fractions are delivered. Alon Witztum is supported by an MRC/Gray Institute DPhil Studentship. Daniel Holyoake is supported by a CRUK/Nuffield Clinical Research Fellowship. Sam Warren and Mike Partridge are supported by CRUK grant C5255/A15935. Maria Hawkins received an MRC Fellowship MC_PC_12001/2.</description><subject>60 APPLIED LIFE SCIENCES</subject><subject>ANIMAL TISSUES</subject><subject>Cancer</subject><subject>COMPRESSION</subject><subject>COMPUTERIZED TOMOGRAPHY</subject><subject>Cone beam computed tomography</subject><subject>Fellowships</subject><subject>NEOPLASMS</subject><subject>PANCREAS</subject><subject>PATIENTS</subject><subject>PLANNING</subject><subject>RADIATION PROTECTION AND DOSIMETRY</subject><subject>Radiation therapy</subject><subject>RADIOTHERAPY</subject><subject>SMALL INTESTINE</subject><subject>Tissues</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNp90EtLw0AUBeBBFKzVhf8g4Eph6p1nJu5qWrXQoqhdD8k8aKTNlEyk9N_bmG51dRb341w4CF0TGBFC1D0Z8UwIybITNKA8ZZhTyE7RACDjmHIQ5-gixi8AkEzAAE0_lniCH9_HGORDMvkO1tXFOpnVrWt8U5i2CnWyCL-xq9pVMi5t2FSdycNm27gYD6dLdOaLdXRXxxyi5dP0M3_B89fnWT6eY0NSyHBphTWGeQkMoDReEV4UJQGwignOSp6mVCrmvKVGGS-VzUQqrBSEKpX6kg3RTd8bYlvpaKrWmZUJde1MqymVlDMlD-q2V6YJMTbO621TbYpmrwnobiVN9HGlg8W93VVrt_8b6sXb0d_1vntedLP8U_4DVG9ySA</recordid><startdate>201606</startdate><enddate>201606</enddate><creator>Witztum, A</creator><creator>Holyoake, D</creator><creator>Warren, S</creator><creator>Partridge, M</creator><creator>Hawkins, M</creator><general>American Association of Physicists in Medicine</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>201606</creationdate><title>SU-D-BRA-06: Duodenal Interfraction Motion with Abdominal Compression</title><author>Witztum, A ; Holyoake, D ; Warren, S ; Partridge, M ; Hawkins, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1709-bd5dcc3f60300bcf814aab100d83543b4772683efd2c8cf68d9575d6512887fb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>60 APPLIED LIFE SCIENCES</topic><topic>ANIMAL TISSUES</topic><topic>Cancer</topic><topic>COMPRESSION</topic><topic>COMPUTERIZED TOMOGRAPHY</topic><topic>Cone beam computed tomography</topic><topic>Fellowships</topic><topic>NEOPLASMS</topic><topic>PANCREAS</topic><topic>PATIENTS</topic><topic>PLANNING</topic><topic>RADIATION PROTECTION AND DOSIMETRY</topic><topic>Radiation therapy</topic><topic>RADIOTHERAPY</topic><topic>SMALL INTESTINE</topic><topic>Tissues</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Witztum, A</creatorcontrib><creatorcontrib>Holyoake, D</creatorcontrib><creatorcontrib>Warren, S</creatorcontrib><creatorcontrib>Partridge, M</creatorcontrib><creatorcontrib>Hawkins, M</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Medical physics (Lancaster)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Witztum, A</au><au>Holyoake, D</au><au>Warren, S</au><au>Partridge, M</au><au>Hawkins, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SU-D-BRA-06: Duodenal Interfraction Motion with Abdominal Compression</atitle><jtitle>Medical physics (Lancaster)</jtitle><date>2016-06</date><risdate>2016</risdate><volume>43</volume><issue>6</issue><spage>3340</spage><epage>3340</epage><pages>3340-3340</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: To quantify the effect of abdominal compression on duodenal motion during pancreatic radiotherapy. Methods: Seven patients treated for pancreatic cancer were selected for analysis. Four patients were treated with abdominal compression and three without. The duodenum was contoured by the same physician on each CBCT (five CBCTs for patients with compression, four for non-compression patients). CBCTs were rigidly registered using a soft tissue match and contours were copied to the delivered plans which were all radical (BED &gt; 50 Gy). The distance between the duodenum on the planning CT and each CBCT was quantified by calculating the root mean square (RMS) distance. The DVHs of each abdominal compression patient was converted to an EQD2 DVH (alpha/beta = 10) using an in-house tool and volumes receiving at least 25, 35, 45, and 50 Gy were recorded. Results: The maximum variation in duodenal volumes on the CBCTs for the four abdominal compression patients were 19.1 cm3 (32.8%), 19.1 cm3 (20.6%), 19.9 cm3 (14.3%), and 12.9 cm3 (27.3%) compared to 15.2 cm3 (17.6%), 34.7 cm3 (83.4%), and 56 cm3 (60.2%) for non-compression patients. The average RMS distance between the duodenum on the planning CT and each CBCT for all abdominal compression patients was 0.3 cm compared to 0.7 cm for non-compressed patients. The largest (and average) difference between the planning CT and CBCTs in volume of duodenum receiving more than 25, 35, 45 and 50 Gy for abdominal compression patients was 11% (5%), 9% (3%), 9% (2%), and 6% (1%). Conclusion: Abdominal compression reduces variation in volume and absolute position of the duodenum throughout treatment. This is seen as an improvement but does not eliminate the need to consider dosimetric effects of motion. Abdominal compression is particularly useful in SBRT when only a few fractions are delivered. Alon Witztum is supported by an MRC/Gray Institute DPhil Studentship. Daniel Holyoake is supported by a CRUK/Nuffield Clinical Research Fellowship. Sam Warren and Mike Partridge are supported by CRUK grant C5255/A15935. Maria Hawkins received an MRC Fellowship MC_PC_12001/2.</abstract><cop>United States</cop><pub>American Association of Physicists in Medicine</pub><doi>10.1118/1.4955639</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical physics (Lancaster), 2016-06, Vol.43 (6), p.3340-3340
issn 0094-2405
2473-4209
language eng
recordid cdi_scitation_primary_10_1118_1_4955639
source Wiley Journals; Alma/SFX Local Collection
subjects 60 APPLIED LIFE SCIENCES
ANIMAL TISSUES
Cancer
COMPRESSION
COMPUTERIZED TOMOGRAPHY
Cone beam computed tomography
Fellowships
NEOPLASMS
PANCREAS
PATIENTS
PLANNING
RADIATION PROTECTION AND DOSIMETRY
Radiation therapy
RADIOTHERAPY
SMALL INTESTINE
Tissues
title SU-D-BRA-06: Duodenal Interfraction Motion with Abdominal Compression
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T12%3A45%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SU-D-BRA-06:%20Duodenal%20Interfraction%20Motion%20with%20Abdominal%20Compression&rft.jtitle=Medical%20physics%20(Lancaster)&rft.au=Witztum,%20A&rft.date=2016-06&rft.volume=43&rft.issue=6&rft.spage=3340&rft.epage=3340&rft.pages=3340-3340&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.4955639&rft_dat=%3Cwiley_scita%3EMP5639%3C/wiley_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true