TU‐D‐BRB‐01: PET/CT Guided Dose Redistribution for HDR Interstitial Brachytherapy of Cervical Cancer

Purpose: Advances in functional imaging may allow identification and targeting of tumor sub‐volumes based on their biological characteristics, allowing selective boosting of dose to radio‐resistant sub‐volumes during treatment planning. The purpose of this study was to redistribute high dose regions...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical Physics 2010-06, Vol.37 (6), p.3390-3391
Hauptverfasser: Yao, R, Templeton, A, Chu, J, Liao, Y, Turian, J, Gielda, B, Zusag, T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3391
container_issue 6
container_start_page 3390
container_title Medical Physics
container_volume 37
creator Yao, R
Templeton, A
Chu, J
Liao, Y
Turian, J
Gielda, B
Zusag, T
description Purpose: Advances in functional imaging may allow identification and targeting of tumor sub‐volumes based on their biological characteristics, allowing selective boosting of dose to radio‐resistant sub‐volumes during treatment planning. The purpose of this study was to redistribute high dose regions toward the PET‐hot regions as identified on PET/CT images during High‐Dose‐Rate (HDR) brachytherapy for cervical cancer while maintaining a clinically acceptable DVH. Material and Methods: FDG‐PET and CT images were acquired and registered. The tumor volume was contoured and segmented into sub‐volumes based on their Standardized Uptake Values (SUV) in PET images. The sub‐volumes with higher SUV were considered metabolically active and therefore required higher radiation dose. The integral tumor was prescribed a uniform dose from external beams followed by a boost dose delivered by HDR interstitial brachytherapy. The HDR treatment plan was optimized using a home‐brew software implementation of an Adaptive Simulated Annealing (ASA) algorithm. The tumor dose was then redistributed by increasing and decreasing the prescription dose to sub‐volumes with higher and lower SUV respectively such that the integral tumor prescription dose was kept constant. A routine cervical cancer case with both uniform and PET‐guided plans is presented. Both plans were optimized based on a generalized Equivalent Uniform Dose (gEUD) cost function and renormalized to V100=95% of prescribed dose to the integral PTV. Their isodose distributions and DVHs were compared. Results: The PET‐guided plan had larger hot spots in and near the PET sub‐volume while the DVH of PTV was kept the same as that of the uniformly prescribed plan. Doses to critical organs were also reduced in the PET‐guided plan. Conclusions: The approach described used PET/CT imaging guiding dose redistribution within PTV so that the hot spots encompass metabolically active tumor sub‐volumes. An IRB approved treatment protocol is underway to study the clinical efficiency of this approach.
doi_str_mv 10.1118/1.3469250
format Article
fullrecord <record><control><sourceid>wiley_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1118_1_3469250</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MP9250</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1770-c0ba7e54a8915ccb112ea7d546b689b148ad8e9a8a64a9f24d480915b0a6ea703</originalsourceid><addsrcrecordid>eNp90MFOwkAQBuCN0URED77BXjUpzLbbdtebtAgkGAkp52a63YYlSMlu0fTmI_iMPoklcNXDzBzmy3_4CblnMGCMiSEbBDySfggXpOfzOPC4D_KS9AAk93wO4TW5cW4DAFEQQo9sstXP13fazWg56jawJ7oYZ8Mko5ODKXVJ09pputSlcY01xaEx9Y5WtaXTdElnu0Zb15jG4JaOLKp126y1xX1L64om2n4Y1X0S3Cltb8lVhVun7863T1Yv4yyZevO3ySx5nnuKxTF4CgqMdchRSBYqVTDma4zLkEdFJGTBuMBSaIkCI46y8nnJBXS0AIw6CEGfPJxyla2ds7rK99a8o21zBvmxpJzl55I6653sp9nq9m-Yvy7O_vHknTINHrv4J_wXMK91uw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>TU‐D‐BRB‐01: PET/CT Guided Dose Redistribution for HDR Interstitial Brachytherapy of Cervical Cancer</title><source>Access via Wiley Online Library</source><source>Alma/SFX Local Collection</source><creator>Yao, R ; Templeton, A ; Chu, J ; Liao, Y ; Turian, J ; Gielda, B ; Zusag, T</creator><creatorcontrib>Yao, R ; Templeton, A ; Chu, J ; Liao, Y ; Turian, J ; Gielda, B ; Zusag, T</creatorcontrib><description>Purpose: Advances in functional imaging may allow identification and targeting of tumor sub‐volumes based on their biological characteristics, allowing selective boosting of dose to radio‐resistant sub‐volumes during treatment planning. The purpose of this study was to redistribute high dose regions toward the PET‐hot regions as identified on PET/CT images during High‐Dose‐Rate (HDR) brachytherapy for cervical cancer while maintaining a clinically acceptable DVH. Material and Methods: FDG‐PET and CT images were acquired and registered. The tumor volume was contoured and segmented into sub‐volumes based on their Standardized Uptake Values (SUV) in PET images. The sub‐volumes with higher SUV were considered metabolically active and therefore required higher radiation dose. The integral tumor was prescribed a uniform dose from external beams followed by a boost dose delivered by HDR interstitial brachytherapy. The HDR treatment plan was optimized using a home‐brew software implementation of an Adaptive Simulated Annealing (ASA) algorithm. The tumor dose was then redistributed by increasing and decreasing the prescription dose to sub‐volumes with higher and lower SUV respectively such that the integral tumor prescription dose was kept constant. A routine cervical cancer case with both uniform and PET‐guided plans is presented. Both plans were optimized based on a generalized Equivalent Uniform Dose (gEUD) cost function and renormalized to V100=95% of prescribed dose to the integral PTV. Their isodose distributions and DVHs were compared. Results: The PET‐guided plan had larger hot spots in and near the PET sub‐volume while the DVH of PTV was kept the same as that of the uniformly prescribed plan. Doses to critical organs were also reduced in the PET‐guided plan. Conclusions: The approach described used PET/CT imaging guiding dose redistribution within PTV so that the hot spots encompass metabolically active tumor sub‐volumes. An IRB approved treatment protocol is underway to study the clinical efficiency of this approach.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.3469250</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>American Association of Physicists in Medicine</publisher><subject>Anatomy ; Annealing ; Brachytherapy ; Cancer ; Computed tomography ; Dosimetry ; Medical image segmentation ; Medical imaging ; Medical treatment planning ; Radiation treatment</subject><ispartof>Medical Physics, 2010-06, Vol.37 (6), p.3390-3391</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2010 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.3469250$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,1417,23930,23931,25140,27924,27925,45575</link.rule.ids></links><search><creatorcontrib>Yao, R</creatorcontrib><creatorcontrib>Templeton, A</creatorcontrib><creatorcontrib>Chu, J</creatorcontrib><creatorcontrib>Liao, Y</creatorcontrib><creatorcontrib>Turian, J</creatorcontrib><creatorcontrib>Gielda, B</creatorcontrib><creatorcontrib>Zusag, T</creatorcontrib><title>TU‐D‐BRB‐01: PET/CT Guided Dose Redistribution for HDR Interstitial Brachytherapy of Cervical Cancer</title><title>Medical Physics</title><description>Purpose: Advances in functional imaging may allow identification and targeting of tumor sub‐volumes based on their biological characteristics, allowing selective boosting of dose to radio‐resistant sub‐volumes during treatment planning. The purpose of this study was to redistribute high dose regions toward the PET‐hot regions as identified on PET/CT images during High‐Dose‐Rate (HDR) brachytherapy for cervical cancer while maintaining a clinically acceptable DVH. Material and Methods: FDG‐PET and CT images were acquired and registered. The tumor volume was contoured and segmented into sub‐volumes based on their Standardized Uptake Values (SUV) in PET images. The sub‐volumes with higher SUV were considered metabolically active and therefore required higher radiation dose. The integral tumor was prescribed a uniform dose from external beams followed by a boost dose delivered by HDR interstitial brachytherapy. The HDR treatment plan was optimized using a home‐brew software implementation of an Adaptive Simulated Annealing (ASA) algorithm. The tumor dose was then redistributed by increasing and decreasing the prescription dose to sub‐volumes with higher and lower SUV respectively such that the integral tumor prescription dose was kept constant. A routine cervical cancer case with both uniform and PET‐guided plans is presented. Both plans were optimized based on a generalized Equivalent Uniform Dose (gEUD) cost function and renormalized to V100=95% of prescribed dose to the integral PTV. Their isodose distributions and DVHs were compared. Results: The PET‐guided plan had larger hot spots in and near the PET sub‐volume while the DVH of PTV was kept the same as that of the uniformly prescribed plan. Doses to critical organs were also reduced in the PET‐guided plan. Conclusions: The approach described used PET/CT imaging guiding dose redistribution within PTV so that the hot spots encompass metabolically active tumor sub‐volumes. An IRB approved treatment protocol is underway to study the clinical efficiency of this approach.</description><subject>Anatomy</subject><subject>Annealing</subject><subject>Brachytherapy</subject><subject>Cancer</subject><subject>Computed tomography</subject><subject>Dosimetry</subject><subject>Medical image segmentation</subject><subject>Medical imaging</subject><subject>Medical treatment planning</subject><subject>Radiation treatment</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp90MFOwkAQBuCN0URED77BXjUpzLbbdtebtAgkGAkp52a63YYlSMlu0fTmI_iMPoklcNXDzBzmy3_4CblnMGCMiSEbBDySfggXpOfzOPC4D_KS9AAk93wO4TW5cW4DAFEQQo9sstXP13fazWg56jawJ7oYZ8Mko5ODKXVJ09pputSlcY01xaEx9Y5WtaXTdElnu0Zb15jG4JaOLKp126y1xX1L64om2n4Y1X0S3Cltb8lVhVun7863T1Yv4yyZevO3ySx5nnuKxTF4CgqMdchRSBYqVTDma4zLkEdFJGTBuMBSaIkCI46y8nnJBXS0AIw6CEGfPJxyla2ds7rK99a8o21zBvmxpJzl55I6653sp9nq9m-Yvy7O_vHknTINHrv4J_wXMK91uw</recordid><startdate>201006</startdate><enddate>201006</enddate><creator>Yao, R</creator><creator>Templeton, A</creator><creator>Chu, J</creator><creator>Liao, Y</creator><creator>Turian, J</creator><creator>Gielda, B</creator><creator>Zusag, T</creator><general>American Association of Physicists in Medicine</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201006</creationdate><title>TU‐D‐BRB‐01: PET/CT Guided Dose Redistribution for HDR Interstitial Brachytherapy of Cervical Cancer</title><author>Yao, R ; Templeton, A ; Chu, J ; Liao, Y ; Turian, J ; Gielda, B ; Zusag, T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1770-c0ba7e54a8915ccb112ea7d546b689b148ad8e9a8a64a9f24d480915b0a6ea703</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Anatomy</topic><topic>Annealing</topic><topic>Brachytherapy</topic><topic>Cancer</topic><topic>Computed tomography</topic><topic>Dosimetry</topic><topic>Medical image segmentation</topic><topic>Medical imaging</topic><topic>Medical treatment planning</topic><topic>Radiation treatment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yao, R</creatorcontrib><creatorcontrib>Templeton, A</creatorcontrib><creatorcontrib>Chu, J</creatorcontrib><creatorcontrib>Liao, Y</creatorcontrib><creatorcontrib>Turian, J</creatorcontrib><creatorcontrib>Gielda, B</creatorcontrib><creatorcontrib>Zusag, T</creatorcontrib><collection>CrossRef</collection><jtitle>Medical Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yao, R</au><au>Templeton, A</au><au>Chu, J</au><au>Liao, Y</au><au>Turian, J</au><au>Gielda, B</au><au>Zusag, T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>TU‐D‐BRB‐01: PET/CT Guided Dose Redistribution for HDR Interstitial Brachytherapy of Cervical Cancer</atitle><jtitle>Medical Physics</jtitle><date>2010-06</date><risdate>2010</risdate><volume>37</volume><issue>6</issue><spage>3390</spage><epage>3391</epage><pages>3390-3391</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: Advances in functional imaging may allow identification and targeting of tumor sub‐volumes based on their biological characteristics, allowing selective boosting of dose to radio‐resistant sub‐volumes during treatment planning. The purpose of this study was to redistribute high dose regions toward the PET‐hot regions as identified on PET/CT images during High‐Dose‐Rate (HDR) brachytherapy for cervical cancer while maintaining a clinically acceptable DVH. Material and Methods: FDG‐PET and CT images were acquired and registered. The tumor volume was contoured and segmented into sub‐volumes based on their Standardized Uptake Values (SUV) in PET images. The sub‐volumes with higher SUV were considered metabolically active and therefore required higher radiation dose. The integral tumor was prescribed a uniform dose from external beams followed by a boost dose delivered by HDR interstitial brachytherapy. The HDR treatment plan was optimized using a home‐brew software implementation of an Adaptive Simulated Annealing (ASA) algorithm. The tumor dose was then redistributed by increasing and decreasing the prescription dose to sub‐volumes with higher and lower SUV respectively such that the integral tumor prescription dose was kept constant. A routine cervical cancer case with both uniform and PET‐guided plans is presented. Both plans were optimized based on a generalized Equivalent Uniform Dose (gEUD) cost function and renormalized to V100=95% of prescribed dose to the integral PTV. Their isodose distributions and DVHs were compared. Results: The PET‐guided plan had larger hot spots in and near the PET sub‐volume while the DVH of PTV was kept the same as that of the uniformly prescribed plan. Doses to critical organs were also reduced in the PET‐guided plan. Conclusions: The approach described used PET/CT imaging guiding dose redistribution within PTV so that the hot spots encompass metabolically active tumor sub‐volumes. An IRB approved treatment protocol is underway to study the clinical efficiency of this approach.</abstract><pub>American Association of Physicists in Medicine</pub><doi>10.1118/1.3469250</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical Physics, 2010-06, Vol.37 (6), p.3390-3391
issn 0094-2405
2473-4209
language eng
recordid cdi_scitation_primary_10_1118_1_3469250
source Access via Wiley Online Library; Alma/SFX Local Collection
subjects Anatomy
Annealing
Brachytherapy
Cancer
Computed tomography
Dosimetry
Medical image segmentation
Medical imaging
Medical treatment planning
Radiation treatment
title TU‐D‐BRB‐01: PET/CT Guided Dose Redistribution for HDR Interstitial Brachytherapy of Cervical Cancer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T20%3A57%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=TU%E2%80%90D%E2%80%90BRB%E2%80%9001:%20PET/CT%20Guided%20Dose%20Redistribution%20for%20HDR%20Interstitial%20Brachytherapy%20of%20Cervical%20Cancer&rft.jtitle=Medical%20Physics&rft.au=Yao,%20R&rft.date=2010-06&rft.volume=37&rft.issue=6&rft.spage=3390&rft.epage=3391&rft.pages=3390-3391&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.3469250&rft_dat=%3Cwiley_scita%3EMP9250%3C/wiley_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true