TH‐D‐AUD C‐02: Reliability Study of Ultrasound Tissue Characterization in Quantitative Measurement of Radiation‐Induced Breast Tissue Toxicity

Purpose: To evaluate the reliability of the ultrasound tissue characterization (UTC) as a measure for breast‐tissue radiation toxicity. Method and Materials: We have recently reported that UTC midband‐fit could be used to assess radiation‐induced tissue toxicity. The reliability of this method is pr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical Physics 2008-06, Vol.35 (6), p.2986-2987
Hauptverfasser: Zhou, J, Zhang, P, Woodhouse, S, Schiff, P, Ballas, L, Kutcher, G, Liu, T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2987
container_issue 6
container_start_page 2986
container_title Medical Physics
container_volume 35
creator Zhou, J
Zhang, P
Woodhouse, S
Schiff, P
Ballas, L
Kutcher, G
Liu, T
description Purpose: To evaluate the reliability of the ultrasound tissue characterization (UTC) as a measure for breast‐tissue radiation toxicity. Method and Materials: We have recently reported that UTC midband‐fit could be used to assess radiation‐induced tissue toxicity. The reliability of this method is presented in this report. Twenty‐three breast patients previously treated with radiation were recruited. Both treated and untreated breasts were scanned by one radiation oncologist. The untreated breasts were used for reliability study, in which two ultrasound radio‐frequency (RF) images were acquired at the same position. A region‐of‐interest (ROI) was selected either manually by a physician or a computer program, in which a fixed ROI was used. Between‐scan repeatability and the correlation between physician and computer program were assessed using intraclass correlation coefficient (ICC). To evaluate the ability of UTC to scale tissue toxicity, the patients were divided into four groups according to patient self‐assessment of breast hardening and the medians of the midband‐fit differences between treated and untreated breast in each group were investigated. Results: The repeatability using single measurement is 0.860 and 0.804 for physician and computer program, respectively. When the average of two measurements is used, the repeatability for computer program is 0.891, which suggests computer program can contest with the physician at the expense of double measurements. The correlation between physician and computer program is very good (ICC = 0.897), which indicates a substantial agreement between the physician and the computer program. For both method, the UTC midband‐fit increases with higher tissue toxicity of the patients. Conclusion: Both physician and computer program can assess toxicity reliably. The physician may prefer the computer program for automatic evaluation of tissue toxicity. There is a clear concordance between the UTC evaluations and the patients' self‐assessment, which proves the reliability of using UTC in quantitative measurement of radiation toxicity.
doi_str_mv 10.1118/1.2962914
format Article
fullrecord <record><control><sourceid>wiley_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1118_1_2962914</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MP2914</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2174-b9470ace34cec1319d8ac1f388e807f7db9dbab78338bee8ae7822de742c80443</originalsourceid><addsrcrecordid>eNp9kL1OwzAUhS0EEqUw8AZeQUqxHbdx2KAFWqkVUNI5cuwbYZQmyHaAMPEITDwgT0L6wwjD1dGVPn1HOggdU9KjlIoz2mPxgMWU76AO41EYcEbiXdQhJOYB46S_jw6ceyKEDMI-6aCvZPz98Tlq72IxwsM2CTvHcyiMzExhfIMffK0bXOV4UXgrXVWXGifGuRrw8FFaqTxY8y69qUpsSnxfy9Ib3_4vgGcgXW1hCaVfGeZSmzXY1kxKXSvQ-NK2jP81JtWbUW3rIdrLZeHgaJtdtLi-SobjYHp7MxleTAPFaMSDLOYRkQpCrkDRkMZaSEXzUAgQJMojncU6k1kkwlBkAEJCJBjTEHGmBOE87KKTjVfZyjkLefpszVLaJqUkXQ2a0nQ7aMsGG_bVFND8Daazuy1_uuGdWu9Rlf_IfwBLXolX</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>TH‐D‐AUD C‐02: Reliability Study of Ultrasound Tissue Characterization in Quantitative Measurement of Radiation‐Induced Breast Tissue Toxicity</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Alma/SFX Local Collection</source><creator>Zhou, J ; Zhang, P ; Woodhouse, S ; Schiff, P ; Ballas, L ; Kutcher, G ; Liu, T</creator><creatorcontrib>Zhou, J ; Zhang, P ; Woodhouse, S ; Schiff, P ; Ballas, L ; Kutcher, G ; Liu, T</creatorcontrib><description>Purpose: To evaluate the reliability of the ultrasound tissue characterization (UTC) as a measure for breast‐tissue radiation toxicity. Method and Materials: We have recently reported that UTC midband‐fit could be used to assess radiation‐induced tissue toxicity. The reliability of this method is presented in this report. Twenty‐three breast patients previously treated with radiation were recruited. Both treated and untreated breasts were scanned by one radiation oncologist. The untreated breasts were used for reliability study, in which two ultrasound radio‐frequency (RF) images were acquired at the same position. A region‐of‐interest (ROI) was selected either manually by a physician or a computer program, in which a fixed ROI was used. Between‐scan repeatability and the correlation between physician and computer program were assessed using intraclass correlation coefficient (ICC). To evaluate the ability of UTC to scale tissue toxicity, the patients were divided into four groups according to patient self‐assessment of breast hardening and the medians of the midband‐fit differences between treated and untreated breast in each group were investigated. Results: The repeatability using single measurement is 0.860 and 0.804 for physician and computer program, respectively. When the average of two measurements is used, the repeatability for computer program is 0.891, which suggests computer program can contest with the physician at the expense of double measurements. The correlation between physician and computer program is very good (ICC = 0.897), which indicates a substantial agreement between the physician and the computer program. For both method, the UTC midband‐fit increases with higher tissue toxicity of the patients. Conclusion: Both physician and computer program can assess toxicity reliably. The physician may prefer the computer program for automatic evaluation of tissue toxicity. There is a clear concordance between the UTC evaluations and the patients' self‐assessment, which proves the reliability of using UTC in quantitative measurement of radiation toxicity.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.2962914</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>American Association of Physicists in Medicine</publisher><subject>Cancer ; Computer software ; Medical imaging ; Radiation treatment ; Radio imaging ; Therapeutics ; Tissue characterization ; Tissues ; Ultrasonography</subject><ispartof>Medical Physics, 2008-06, Vol.35 (6), p.2986-2987</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2008 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2174-b9470ace34cec1319d8ac1f388e807f7db9dbab78338bee8ae7822de742c80443</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.2962914$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,1417,23929,23930,25139,27923,27924,45574</link.rule.ids></links><search><creatorcontrib>Zhou, J</creatorcontrib><creatorcontrib>Zhang, P</creatorcontrib><creatorcontrib>Woodhouse, S</creatorcontrib><creatorcontrib>Schiff, P</creatorcontrib><creatorcontrib>Ballas, L</creatorcontrib><creatorcontrib>Kutcher, G</creatorcontrib><creatorcontrib>Liu, T</creatorcontrib><title>TH‐D‐AUD C‐02: Reliability Study of Ultrasound Tissue Characterization in Quantitative Measurement of Radiation‐Induced Breast Tissue Toxicity</title><title>Medical Physics</title><description>Purpose: To evaluate the reliability of the ultrasound tissue characterization (UTC) as a measure for breast‐tissue radiation toxicity. Method and Materials: We have recently reported that UTC midband‐fit could be used to assess radiation‐induced tissue toxicity. The reliability of this method is presented in this report. Twenty‐three breast patients previously treated with radiation were recruited. Both treated and untreated breasts were scanned by one radiation oncologist. The untreated breasts were used for reliability study, in which two ultrasound radio‐frequency (RF) images were acquired at the same position. A region‐of‐interest (ROI) was selected either manually by a physician or a computer program, in which a fixed ROI was used. Between‐scan repeatability and the correlation between physician and computer program were assessed using intraclass correlation coefficient (ICC). To evaluate the ability of UTC to scale tissue toxicity, the patients were divided into four groups according to patient self‐assessment of breast hardening and the medians of the midband‐fit differences between treated and untreated breast in each group were investigated. Results: The repeatability using single measurement is 0.860 and 0.804 for physician and computer program, respectively. When the average of two measurements is used, the repeatability for computer program is 0.891, which suggests computer program can contest with the physician at the expense of double measurements. The correlation between physician and computer program is very good (ICC = 0.897), which indicates a substantial agreement between the physician and the computer program. For both method, the UTC midband‐fit increases with higher tissue toxicity of the patients. Conclusion: Both physician and computer program can assess toxicity reliably. The physician may prefer the computer program for automatic evaluation of tissue toxicity. There is a clear concordance between the UTC evaluations and the patients' self‐assessment, which proves the reliability of using UTC in quantitative measurement of radiation toxicity.</description><subject>Cancer</subject><subject>Computer software</subject><subject>Medical imaging</subject><subject>Radiation treatment</subject><subject>Radio imaging</subject><subject>Therapeutics</subject><subject>Tissue characterization</subject><subject>Tissues</subject><subject>Ultrasonography</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNp9kL1OwzAUhS0EEqUw8AZeQUqxHbdx2KAFWqkVUNI5cuwbYZQmyHaAMPEITDwgT0L6wwjD1dGVPn1HOggdU9KjlIoz2mPxgMWU76AO41EYcEbiXdQhJOYB46S_jw6ceyKEDMI-6aCvZPz98Tlq72IxwsM2CTvHcyiMzExhfIMffK0bXOV4UXgrXVWXGifGuRrw8FFaqTxY8y69qUpsSnxfy9Ib3_4vgGcgXW1hCaVfGeZSmzXY1kxKXSvQ-NK2jP81JtWbUW3rIdrLZeHgaJtdtLi-SobjYHp7MxleTAPFaMSDLOYRkQpCrkDRkMZaSEXzUAgQJMojncU6k1kkwlBkAEJCJBjTEHGmBOE87KKTjVfZyjkLefpszVLaJqUkXQ2a0nQ7aMsGG_bVFND8Daazuy1_uuGdWu9Rlf_IfwBLXolX</recordid><startdate>200806</startdate><enddate>200806</enddate><creator>Zhou, J</creator><creator>Zhang, P</creator><creator>Woodhouse, S</creator><creator>Schiff, P</creator><creator>Ballas, L</creator><creator>Kutcher, G</creator><creator>Liu, T</creator><general>American Association of Physicists in Medicine</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200806</creationdate><title>TH‐D‐AUD C‐02: Reliability Study of Ultrasound Tissue Characterization in Quantitative Measurement of Radiation‐Induced Breast Tissue Toxicity</title><author>Zhou, J ; Zhang, P ; Woodhouse, S ; Schiff, P ; Ballas, L ; Kutcher, G ; Liu, T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2174-b9470ace34cec1319d8ac1f388e807f7db9dbab78338bee8ae7822de742c80443</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Cancer</topic><topic>Computer software</topic><topic>Medical imaging</topic><topic>Radiation treatment</topic><topic>Radio imaging</topic><topic>Therapeutics</topic><topic>Tissue characterization</topic><topic>Tissues</topic><topic>Ultrasonography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhou, J</creatorcontrib><creatorcontrib>Zhang, P</creatorcontrib><creatorcontrib>Woodhouse, S</creatorcontrib><creatorcontrib>Schiff, P</creatorcontrib><creatorcontrib>Ballas, L</creatorcontrib><creatorcontrib>Kutcher, G</creatorcontrib><creatorcontrib>Liu, T</creatorcontrib><collection>CrossRef</collection><jtitle>Medical Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhou, J</au><au>Zhang, P</au><au>Woodhouse, S</au><au>Schiff, P</au><au>Ballas, L</au><au>Kutcher, G</au><au>Liu, T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>TH‐D‐AUD C‐02: Reliability Study of Ultrasound Tissue Characterization in Quantitative Measurement of Radiation‐Induced Breast Tissue Toxicity</atitle><jtitle>Medical Physics</jtitle><date>2008-06</date><risdate>2008</risdate><volume>35</volume><issue>6</issue><spage>2986</spage><epage>2987</epage><pages>2986-2987</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: To evaluate the reliability of the ultrasound tissue characterization (UTC) as a measure for breast‐tissue radiation toxicity. Method and Materials: We have recently reported that UTC midband‐fit could be used to assess radiation‐induced tissue toxicity. The reliability of this method is presented in this report. Twenty‐three breast patients previously treated with radiation were recruited. Both treated and untreated breasts were scanned by one radiation oncologist. The untreated breasts were used for reliability study, in which two ultrasound radio‐frequency (RF) images were acquired at the same position. A region‐of‐interest (ROI) was selected either manually by a physician or a computer program, in which a fixed ROI was used. Between‐scan repeatability and the correlation between physician and computer program were assessed using intraclass correlation coefficient (ICC). To evaluate the ability of UTC to scale tissue toxicity, the patients were divided into four groups according to patient self‐assessment of breast hardening and the medians of the midband‐fit differences between treated and untreated breast in each group were investigated. Results: The repeatability using single measurement is 0.860 and 0.804 for physician and computer program, respectively. When the average of two measurements is used, the repeatability for computer program is 0.891, which suggests computer program can contest with the physician at the expense of double measurements. The correlation between physician and computer program is very good (ICC = 0.897), which indicates a substantial agreement between the physician and the computer program. For both method, the UTC midband‐fit increases with higher tissue toxicity of the patients. Conclusion: Both physician and computer program can assess toxicity reliably. The physician may prefer the computer program for automatic evaluation of tissue toxicity. There is a clear concordance between the UTC evaluations and the patients' self‐assessment, which proves the reliability of using UTC in quantitative measurement of radiation toxicity.</abstract><pub>American Association of Physicists in Medicine</pub><doi>10.1118/1.2962914</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical Physics, 2008-06, Vol.35 (6), p.2986-2987
issn 0094-2405
2473-4209
language eng
recordid cdi_scitation_primary_10_1118_1_2962914
source Wiley Online Library Journals Frontfile Complete; Alma/SFX Local Collection
subjects Cancer
Computer software
Medical imaging
Radiation treatment
Radio imaging
Therapeutics
Tissue characterization
Tissues
Ultrasonography
title TH‐D‐AUD C‐02: Reliability Study of Ultrasound Tissue Characterization in Quantitative Measurement of Radiation‐Induced Breast Tissue Toxicity
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T20%3A48%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=TH%E2%80%90D%E2%80%90AUD%20C%E2%80%9002:%20Reliability%20Study%20of%20Ultrasound%20Tissue%20Characterization%20in%20Quantitative%20Measurement%20of%20Radiation%E2%80%90Induced%20Breast%20Tissue%20Toxicity&rft.jtitle=Medical%20Physics&rft.au=Zhou,%20J&rft.date=2008-06&rft.volume=35&rft.issue=6&rft.spage=2986&rft.epage=2987&rft.pages=2986-2987&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.2962914&rft_dat=%3Cwiley_scita%3EMP2914%3C/wiley_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true