Technique for optical characterization of exposure tool imaging performance down to 100 nm

A new technique for accurate and fast characterization of exposure tool imaging performance is presented. It is based on optical measurements of a macroscopically large length of test marks printed in a photoresist in a two-step process. In the first step, the line of the specific critical dimension...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures 1999-11, Vol.17 (6), p.3285-3290
Hauptverfasser: Grodnensky, I., Suwa, K., Farrar, N., Johnson, E., Pan, J.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3290
container_issue 6
container_start_page 3285
container_title Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures
container_volume 17
creator Grodnensky, I.
Suwa, K.
Farrar, N.
Johnson, E.
Pan, J.
description A new technique for accurate and fast characterization of exposure tool imaging performance is presented. It is based on optical measurements of a macroscopically large length of test marks printed in a photoresist in a two-step process. In the first step, the line of the specific critical dimension (CD) is exposed with energy of one-half the nominal energy for a fully formed image. In the second step, the line of the same CD but with a slightly different orientation is exposed with the same energy as in the first step in such a way that its image superimposes the image exposed in the first step. The length of the resulting test mark is linearly proportional to the width of a line printed in a regular exposure process and is inversely proportional to sin(α), where 2α is an angle between two orientations. The coefficient of proportionality is found to be constant for a given resist process over broad ranges of CD variations caused by defocusing, aberrations, exposure dose change, etc. The mark length is measured rapidly with high accuracy by an optical scanning system and the result is then converted into the CD value. A measurement precision (3σ) of 0.5 nm is achieved for sub-150 nm CDs. Results of deep ultraviolet exposure tool characterization at CDs down to 100 nm are presented.
doi_str_mv 10.1116/1.590996
format Article
fullrecord <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_scitation_primary_10_1116_1_590996</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>scitation_primary_10_1116_1_590996</sourcerecordid><originalsourceid>FETCH-LOGICAL-c293t-6f2c3fdc0036a98a117db64de2ef75a8a5c9f995eeb7cc80fcad1b966b8233e63</originalsourceid><addsrcrecordid>eNp9kEtPwzAQhC0EEqUg8RN8hEOKN26c-IgqXlIlLkVCXCJns26N2jjYKa9fTyCoFyROe5hvRrPD2CmICQCoC5hkWmit9tgIslQkRabyfTYSuZwmKcDjITuK8VkIoTIpR-xpQbhq3MuWuPWB-7ZzaNYcVyYY7Ci4T9M533BvOb23Pm4D8c77NXcbs3TNkrcUeuPGNEi89m9Nr3IQgjebY3ZgzTrSye8ds4frq8XsNpnf39zNLucJplp2ibIpSlujEFIZXRiAvK7UtKaUbJ6ZwmSordYZUZUjFsKiqaHSSlVFKiUpOWZnQy4GH2MgW7ahbxc-ShDl9yYllMMmPXo-oBFd9_PYjn31YceVbW3_Y__kfgHptnFM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Technique for optical characterization of exposure tool imaging performance down to 100 nm</title><source>AIP Journals Complete</source><creator>Grodnensky, I. ; Suwa, K. ; Farrar, N. ; Johnson, E. ; Pan, J.</creator><creatorcontrib>Grodnensky, I. ; Suwa, K. ; Farrar, N. ; Johnson, E. ; Pan, J.</creatorcontrib><description>A new technique for accurate and fast characterization of exposure tool imaging performance is presented. It is based on optical measurements of a macroscopically large length of test marks printed in a photoresist in a two-step process. In the first step, the line of the specific critical dimension (CD) is exposed with energy of one-half the nominal energy for a fully formed image. In the second step, the line of the same CD but with a slightly different orientation is exposed with the same energy as in the first step in such a way that its image superimposes the image exposed in the first step. The length of the resulting test mark is linearly proportional to the width of a line printed in a regular exposure process and is inversely proportional to sin(α), where 2α is an angle between two orientations. The coefficient of proportionality is found to be constant for a given resist process over broad ranges of CD variations caused by defocusing, aberrations, exposure dose change, etc. The mark length is measured rapidly with high accuracy by an optical scanning system and the result is then converted into the CD value. A measurement precision (3σ) of 0.5 nm is achieved for sub-150 nm CDs. Results of deep ultraviolet exposure tool characterization at CDs down to 100 nm are presented.</description><identifier>ISSN: 0734-211X</identifier><identifier>ISSN: 1071-1023</identifier><identifier>EISSN: 1520-8567</identifier><identifier>DOI: 10.1116/1.590996</identifier><identifier>CODEN: JVTBD9</identifier><language>eng</language><ispartof>Journal of Vacuum Science &amp; Technology B: Microelectronics and Nanometer Structures, 1999-11, Vol.17 (6), p.3285-3290</ispartof><rights>American Vacuum Society</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c293t-6f2c3fdc0036a98a117db64de2ef75a8a5c9f995eeb7cc80fcad1b966b8233e63</citedby><cites>FETCH-LOGICAL-c293t-6f2c3fdc0036a98a117db64de2ef75a8a5c9f995eeb7cc80fcad1b966b8233e63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,794,4510,23929,23930,25139,27923,27924</link.rule.ids></links><search><creatorcontrib>Grodnensky, I.</creatorcontrib><creatorcontrib>Suwa, K.</creatorcontrib><creatorcontrib>Farrar, N.</creatorcontrib><creatorcontrib>Johnson, E.</creatorcontrib><creatorcontrib>Pan, J.</creatorcontrib><title>Technique for optical characterization of exposure tool imaging performance down to 100 nm</title><title>Journal of Vacuum Science &amp; Technology B: Microelectronics and Nanometer Structures</title><description>A new technique for accurate and fast characterization of exposure tool imaging performance is presented. It is based on optical measurements of a macroscopically large length of test marks printed in a photoresist in a two-step process. In the first step, the line of the specific critical dimension (CD) is exposed with energy of one-half the nominal energy for a fully formed image. In the second step, the line of the same CD but with a slightly different orientation is exposed with the same energy as in the first step in such a way that its image superimposes the image exposed in the first step. The length of the resulting test mark is linearly proportional to the width of a line printed in a regular exposure process and is inversely proportional to sin(α), where 2α is an angle between two orientations. The coefficient of proportionality is found to be constant for a given resist process over broad ranges of CD variations caused by defocusing, aberrations, exposure dose change, etc. The mark length is measured rapidly with high accuracy by an optical scanning system and the result is then converted into the CD value. A measurement precision (3σ) of 0.5 nm is achieved for sub-150 nm CDs. Results of deep ultraviolet exposure tool characterization at CDs down to 100 nm are presented.</description><issn>0734-211X</issn><issn>1071-1023</issn><issn>1520-8567</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNp9kEtPwzAQhC0EEqUg8RN8hEOKN26c-IgqXlIlLkVCXCJns26N2jjYKa9fTyCoFyROe5hvRrPD2CmICQCoC5hkWmit9tgIslQkRabyfTYSuZwmKcDjITuK8VkIoTIpR-xpQbhq3MuWuPWB-7ZzaNYcVyYY7Ci4T9M533BvOb23Pm4D8c77NXcbs3TNkrcUeuPGNEi89m9Nr3IQgjebY3ZgzTrSye8ds4frq8XsNpnf39zNLucJplp2ibIpSlujEFIZXRiAvK7UtKaUbJ6ZwmSordYZUZUjFsKiqaHSSlVFKiUpOWZnQy4GH2MgW7ahbxc-ShDl9yYllMMmPXo-oBFd9_PYjn31YceVbW3_Y__kfgHptnFM</recordid><startdate>19991101</startdate><enddate>19991101</enddate><creator>Grodnensky, I.</creator><creator>Suwa, K.</creator><creator>Farrar, N.</creator><creator>Johnson, E.</creator><creator>Pan, J.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19991101</creationdate><title>Technique for optical characterization of exposure tool imaging performance down to 100 nm</title><author>Grodnensky, I. ; Suwa, K. ; Farrar, N. ; Johnson, E. ; Pan, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c293t-6f2c3fdc0036a98a117db64de2ef75a8a5c9f995eeb7cc80fcad1b966b8233e63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Grodnensky, I.</creatorcontrib><creatorcontrib>Suwa, K.</creatorcontrib><creatorcontrib>Farrar, N.</creatorcontrib><creatorcontrib>Johnson, E.</creatorcontrib><creatorcontrib>Pan, J.</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of Vacuum Science &amp; Technology B: Microelectronics and Nanometer Structures</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Grodnensky, I.</au><au>Suwa, K.</au><au>Farrar, N.</au><au>Johnson, E.</au><au>Pan, J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Technique for optical characterization of exposure tool imaging performance down to 100 nm</atitle><jtitle>Journal of Vacuum Science &amp; Technology B: Microelectronics and Nanometer Structures</jtitle><date>1999-11-01</date><risdate>1999</risdate><volume>17</volume><issue>6</issue><spage>3285</spage><epage>3290</epage><pages>3285-3290</pages><issn>0734-211X</issn><issn>1071-1023</issn><eissn>1520-8567</eissn><coden>JVTBD9</coden><abstract>A new technique for accurate and fast characterization of exposure tool imaging performance is presented. It is based on optical measurements of a macroscopically large length of test marks printed in a photoresist in a two-step process. In the first step, the line of the specific critical dimension (CD) is exposed with energy of one-half the nominal energy for a fully formed image. In the second step, the line of the same CD but with a slightly different orientation is exposed with the same energy as in the first step in such a way that its image superimposes the image exposed in the first step. The length of the resulting test mark is linearly proportional to the width of a line printed in a regular exposure process and is inversely proportional to sin(α), where 2α is an angle between two orientations. The coefficient of proportionality is found to be constant for a given resist process over broad ranges of CD variations caused by defocusing, aberrations, exposure dose change, etc. The mark length is measured rapidly with high accuracy by an optical scanning system and the result is then converted into the CD value. A measurement precision (3σ) of 0.5 nm is achieved for sub-150 nm CDs. Results of deep ultraviolet exposure tool characterization at CDs down to 100 nm are presented.</abstract><doi>10.1116/1.590996</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0734-211X
ispartof Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures, 1999-11, Vol.17 (6), p.3285-3290
issn 0734-211X
1071-1023
1520-8567
language eng
recordid cdi_scitation_primary_10_1116_1_590996
source AIP Journals Complete
title Technique for optical characterization of exposure tool imaging performance down to 100 nm
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T01%3A52%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Technique%20for%20optical%20characterization%20of%20exposure%20tool%20imaging%20performance%20down%20to%20100%20nm&rft.jtitle=Journal%20of%20Vacuum%20Science%20&%20Technology%20B:%20Microelectronics%20and%20Nanometer%20Structures&rft.au=Grodnensky,%20I.&rft.date=1999-11-01&rft.volume=17&rft.issue=6&rft.spage=3285&rft.epage=3290&rft.pages=3285-3290&rft.issn=0734-211X&rft.eissn=1520-8567&rft.coden=JVTBD9&rft_id=info:doi/10.1116/1.590996&rft_dat=%3Cscitation_cross%3Escitation_primary_10_1116_1_590996%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true