Pulsed ion deflection to overcome detector saturation in cryogenic ice sampling

In 2014, we introduced a new experimental approach to study the UV photo-processing of cryogenic ices of astrophysical interest using laser ablation in a combination of ionization and time-of-flight mass spectrometry (ToF-MS). The setup, Mass Analytical Tool to Research Interstellar ICES, allowed us...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2024-02, Vol.95 (2)
Hauptverfasser: Samarth, P., Bulak, M., Paardekooper, D., Chuang, K.-J., Linnartz, H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2
container_start_page
container_title Review of scientific instruments
container_volume 95
creator Samarth, P.
Bulak, M.
Paardekooper, D.
Chuang, K.-J.
Linnartz, H.
description In 2014, we introduced a new experimental approach to study the UV photo-processing of cryogenic ices of astrophysical interest using laser ablation in a combination of ionization and time-of-flight mass spectrometry (ToF-MS). The setup, Mass Analytical Tool to Research Interstellar ICES, allowed us to detect newly formed species at low abundances. However, we found that with the increase in molecular complexity over the years, the detection of larger photoproducts was hindered by the dynamic range of detectors used. Here, we introduce a method to overcome this issue that we expect to be useful for similar applications in other research fields. The concept is based on a precisely controlled high-energy pulser that regulates the voltage across the deflection plates of the ToF-MS instrument to deflect the most abundant species and prevent them from reaching the detector. In this way, the detector sensitivity can be increased from an operating voltage of 2500 V up to 3000 V. The applicability is first illustrated in the simple case of an argon matrix, where 40Ar+ ions are deflected to increase the detection sensitivity for 40Ar2+ at m/z = 20 and 40Ar2+ at m/z = 80 by a factor 30. Similarly, it is shown that substantially larger complex organic molecules, an important species in astrochemical reaction networks, can be measured for UV irradiated methanol ice.
doi_str_mv 10.1063/5.0186448
format Article
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_5_0186448</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2933183893</sourcerecordid><originalsourceid>FETCH-LOGICAL-c343t-538ee13e90b5c3eba9c9521c7974bbca84d42cac8a493ddc8b21ff9d89af7e193</originalsourceid><addsrcrecordid>eNp9kM1LxDAQxYMo7rp68B-QghcVuiZN2iZHWfyChfWg55JOp0uWtlmTVtj_3uyHHjw4lzfM-_EYHiGXjE4Zzfh9OqVMZkLIIzJmVKo4zxJ-TMaUchFnuZAjcub9ioZJGTslIy5FwpI0H5PF29B4rCJju6jCukHot2tvI_uFDmyL4dyHq3WR1_3g9M43XQRuY5fYGYgMYPDadWO65Tk5qXVIvDjohHw8Pb7PXuL54vl19jCPgQvexymXiIyjomUKHEutQKUJg1zloixBS1GJBDRILRSvKpBlwupaVVLpOkem-ITc7HPXzn4O6PuiNR6waXSHdvBFojgXGcs4Dej1H3RlB9eF73YUk1wGmZDbPQXOeu-wLtbOtNptCkaLbctFWhxaDuzVIXEoW6x-yZ9aA3C3BzyYftfYP2nf1KmEgA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2933183893</pqid></control><display><type>article</type><title>Pulsed ion deflection to overcome detector saturation in cryogenic ice sampling</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Samarth, P. ; Bulak, M. ; Paardekooper, D. ; Chuang, K.-J. ; Linnartz, H.</creator><creatorcontrib>Samarth, P. ; Bulak, M. ; Paardekooper, D. ; Chuang, K.-J. ; Linnartz, H.</creatorcontrib><description>In 2014, we introduced a new experimental approach to study the UV photo-processing of cryogenic ices of astrophysical interest using laser ablation in a combination of ionization and time-of-flight mass spectrometry (ToF-MS). The setup, Mass Analytical Tool to Research Interstellar ICES, allowed us to detect newly formed species at low abundances. However, we found that with the increase in molecular complexity over the years, the detection of larger photoproducts was hindered by the dynamic range of detectors used. Here, we introduce a method to overcome this issue that we expect to be useful for similar applications in other research fields. The concept is based on a precisely controlled high-energy pulser that regulates the voltage across the deflection plates of the ToF-MS instrument to deflect the most abundant species and prevent them from reaching the detector. In this way, the detector sensitivity can be increased from an operating voltage of 2500 V up to 3000 V. The applicability is first illustrated in the simple case of an argon matrix, where 40Ar+ ions are deflected to increase the detection sensitivity for 40Ar2+ at m/z = 20 and 40Ar2+ at m/z = 80 by a factor 30. Similarly, it is shown that substantially larger complex organic molecules, an important species in astrochemical reaction networks, can be measured for UV irradiated methanol ice.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/5.0186448</identifier><identifier>PMID: 38421257</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><subject>Argon ; Complexity ; Deflection ; Electric potential ; Ice ; Interstellar matter ; Laser ablation ; Mass spectrometry ; Organic chemistry ; Sensitivity ; Sensors ; Voltage</subject><ispartof>Review of scientific instruments, 2024-02, Vol.95 (2)</ispartof><rights>Author(s)</rights><rights>2024 Author(s). Published under an exclusive license by AIP Publishing.</rights><rights>2024 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c343t-538ee13e90b5c3eba9c9521c7974bbca84d42cac8a493ddc8b21ff9d89af7e193</cites><orcidid>0000-0002-8322-3538 ; 0000-0001-6877-5046 ; 0009-0005-8218-5647</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/5.0186448$$EHTML$$P50$$Gscitation$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,790,4498,27901,27902,76353</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38421257$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Samarth, P.</creatorcontrib><creatorcontrib>Bulak, M.</creatorcontrib><creatorcontrib>Paardekooper, D.</creatorcontrib><creatorcontrib>Chuang, K.-J.</creatorcontrib><creatorcontrib>Linnartz, H.</creatorcontrib><title>Pulsed ion deflection to overcome detector saturation in cryogenic ice sampling</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>In 2014, we introduced a new experimental approach to study the UV photo-processing of cryogenic ices of astrophysical interest using laser ablation in a combination of ionization and time-of-flight mass spectrometry (ToF-MS). The setup, Mass Analytical Tool to Research Interstellar ICES, allowed us to detect newly formed species at low abundances. However, we found that with the increase in molecular complexity over the years, the detection of larger photoproducts was hindered by the dynamic range of detectors used. Here, we introduce a method to overcome this issue that we expect to be useful for similar applications in other research fields. The concept is based on a precisely controlled high-energy pulser that regulates the voltage across the deflection plates of the ToF-MS instrument to deflect the most abundant species and prevent them from reaching the detector. In this way, the detector sensitivity can be increased from an operating voltage of 2500 V up to 3000 V. The applicability is first illustrated in the simple case of an argon matrix, where 40Ar+ ions are deflected to increase the detection sensitivity for 40Ar2+ at m/z = 20 and 40Ar2+ at m/z = 80 by a factor 30. Similarly, it is shown that substantially larger complex organic molecules, an important species in astrochemical reaction networks, can be measured for UV irradiated methanol ice.</description><subject>Argon</subject><subject>Complexity</subject><subject>Deflection</subject><subject>Electric potential</subject><subject>Ice</subject><subject>Interstellar matter</subject><subject>Laser ablation</subject><subject>Mass spectrometry</subject><subject>Organic chemistry</subject><subject>Sensitivity</subject><subject>Sensors</subject><subject>Voltage</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kM1LxDAQxYMo7rp68B-QghcVuiZN2iZHWfyChfWg55JOp0uWtlmTVtj_3uyHHjw4lzfM-_EYHiGXjE4Zzfh9OqVMZkLIIzJmVKo4zxJ-TMaUchFnuZAjcub9ioZJGTslIy5FwpI0H5PF29B4rCJju6jCukHot2tvI_uFDmyL4dyHq3WR1_3g9M43XQRuY5fYGYgMYPDadWO65Tk5qXVIvDjohHw8Pb7PXuL54vl19jCPgQvexymXiIyjomUKHEutQKUJg1zloixBS1GJBDRILRSvKpBlwupaVVLpOkem-ITc7HPXzn4O6PuiNR6waXSHdvBFojgXGcs4Dej1H3RlB9eF73YUk1wGmZDbPQXOeu-wLtbOtNptCkaLbctFWhxaDuzVIXEoW6x-yZ9aA3C3BzyYftfYP2nf1KmEgA</recordid><startdate>20240201</startdate><enddate>20240201</enddate><creator>Samarth, P.</creator><creator>Bulak, M.</creator><creator>Paardekooper, D.</creator><creator>Chuang, K.-J.</creator><creator>Linnartz, H.</creator><general>American Institute of Physics</general><scope>AJDQP</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-8322-3538</orcidid><orcidid>https://orcid.org/0000-0001-6877-5046</orcidid><orcidid>https://orcid.org/0009-0005-8218-5647</orcidid></search><sort><creationdate>20240201</creationdate><title>Pulsed ion deflection to overcome detector saturation in cryogenic ice sampling</title><author>Samarth, P. ; Bulak, M. ; Paardekooper, D. ; Chuang, K.-J. ; Linnartz, H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c343t-538ee13e90b5c3eba9c9521c7974bbca84d42cac8a493ddc8b21ff9d89af7e193</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Argon</topic><topic>Complexity</topic><topic>Deflection</topic><topic>Electric potential</topic><topic>Ice</topic><topic>Interstellar matter</topic><topic>Laser ablation</topic><topic>Mass spectrometry</topic><topic>Organic chemistry</topic><topic>Sensitivity</topic><topic>Sensors</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Samarth, P.</creatorcontrib><creatorcontrib>Bulak, M.</creatorcontrib><creatorcontrib>Paardekooper, D.</creatorcontrib><creatorcontrib>Chuang, K.-J.</creatorcontrib><creatorcontrib>Linnartz, H.</creatorcontrib><collection>AIP Open Access Journals</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Samarth, P.</au><au>Bulak, M.</au><au>Paardekooper, D.</au><au>Chuang, K.-J.</au><au>Linnartz, H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pulsed ion deflection to overcome detector saturation in cryogenic ice sampling</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2024-02-01</date><risdate>2024</risdate><volume>95</volume><issue>2</issue><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>In 2014, we introduced a new experimental approach to study the UV photo-processing of cryogenic ices of astrophysical interest using laser ablation in a combination of ionization and time-of-flight mass spectrometry (ToF-MS). The setup, Mass Analytical Tool to Research Interstellar ICES, allowed us to detect newly formed species at low abundances. However, we found that with the increase in molecular complexity over the years, the detection of larger photoproducts was hindered by the dynamic range of detectors used. Here, we introduce a method to overcome this issue that we expect to be useful for similar applications in other research fields. The concept is based on a precisely controlled high-energy pulser that regulates the voltage across the deflection plates of the ToF-MS instrument to deflect the most abundant species and prevent them from reaching the detector. In this way, the detector sensitivity can be increased from an operating voltage of 2500 V up to 3000 V. The applicability is first illustrated in the simple case of an argon matrix, where 40Ar+ ions are deflected to increase the detection sensitivity for 40Ar2+ at m/z = 20 and 40Ar2+ at m/z = 80 by a factor 30. Similarly, it is shown that substantially larger complex organic molecules, an important species in astrochemical reaction networks, can be measured for UV irradiated methanol ice.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>38421257</pmid><doi>10.1063/5.0186448</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-8322-3538</orcidid><orcidid>https://orcid.org/0000-0001-6877-5046</orcidid><orcidid>https://orcid.org/0009-0005-8218-5647</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2024-02, Vol.95 (2)
issn 0034-6748
1089-7623
language eng
recordid cdi_scitation_primary_10_1063_5_0186448
source AIP Journals Complete; Alma/SFX Local Collection
subjects Argon
Complexity
Deflection
Electric potential
Ice
Interstellar matter
Laser ablation
Mass spectrometry
Organic chemistry
Sensitivity
Sensors
Voltage
title Pulsed ion deflection to overcome detector saturation in cryogenic ice sampling
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T13%3A15%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pulsed%20ion%20deflection%20to%20overcome%20detector%20saturation%20in%20cryogenic%20ice%20sampling&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Samarth,%20P.&rft.date=2024-02-01&rft.volume=95&rft.issue=2&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/5.0186448&rft_dat=%3Cproquest_scita%3E2933183893%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2933183893&rft_id=info:pmid/38421257&rfr_iscdi=true