Calibration of low-cost portable particulate counter (PC) to standardized-certified PC
The use of air purifier to clean the room with poor ventilation is considered as a fast and common solution to minimize the spread of SARS-CoV-2 nowadays. However, the efficacy of the filter within the air purifier must be tested priorly to ensure the cleanliness of the air, since the size of this n...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 1 |
container_start_page | |
container_title | |
container_volume | 2710 |
creator | Septiana, Reski Roihan, Ibnu Riantono, Arbi Juan, K. Koestoer, Raldi A. |
description | The use of air purifier to clean the room with poor ventilation is considered as a fast and common solution to minimize the spread of SARS-CoV-2 nowadays. However, the efficacy of the filter within the air purifier must be tested priorly to ensure the cleanliness of the air, since the size of this novel virus is very small. Inexpensive particulate counter which is common in the market, such as HT-9600 particle counter can be used to test the efficacy of the filter if the device is properly calibrated. This paper aims to calibrate the HTI portable particulate counter to Solair3100 which has been calibrated by NIST using ISO 21501-4 and ISO 17025 standards. Both devices were used to measure the amount of particle in various places to see their characteristic. The same nonlinear trend produced by both devices in reading the amount of particle in different places made the calibration effort can be done. Data used for calibration were the average reading of the number of particles from various conditions. Calibration curve of HT-9600 particle counter was obtained by plotting the average readings of both devices in a single plot. The obtained calibration curve is a non-linear plot which represents the characteristic of particle counter in reading the amount of particle based on its respective size. The obtained calibration function from the curve shows great tendency in reading the right amount of particle in the air with minimum error. |
doi_str_mv | 10.1063/5.0144594 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_5_0144594</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2922640126</sourcerecordid><originalsourceid>FETCH-LOGICAL-p1684-6e86d2bf5495517c85e550b14faa03549739c8c4c47b09436aec82aa69c0b2603</originalsourceid><addsrcrecordid>eNotkEtLxDAUhYMoOI4u_AcBNyp0zLvNUoovGHAWKu7CbZpChtrUJEX011udWV04fJxzz0HonJIVJYrfyBWhQkgtDtCCSkmLUlF1iBaEaFEwwd-P0UlKW0KYLstqgd5q6H0TIfsw4NDhPnwVNqSMxxAzNL3DI8Ts7dRDdtiGacgu4stNfYVzwCnD0EJs_Y9rC-tmsPOuxZv6FB110Cd3tr9L9Hp_91I_Fuvnh6f6dl2MVFWiUK5SLWs6KfT8a2kr6aQkDRUdAOGzWnJtKyusKJu5AFfgbMUAlLakYYrwJbrY-Y4xfE4uZbMNUxzmSMM0Y0oQytRMXe-oZH3-r2rG6D8gfhtKzN9uRpr9bvwXUHJePg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2922640126</pqid></control><display><type>conference_proceeding</type><title>Calibration of low-cost portable particulate counter (PC) to standardized-certified PC</title><source>AIP Journals Complete</source><creator>Septiana, Reski ; Roihan, Ibnu ; Riantono, Arbi ; Juan, K. ; Koestoer, Raldi A.</creator><contributor>Maknun, Imam Jauhari ; Harahap, Yulia Nurliani ; Harwahyu, Ruki ; Ardi, Romadhani ; Fatriansyah, Jaka Fajar ; Irwansyah, Ridho ; Dhelika, Radon ; Pratama, Mochamad Adhiraga ; Kusuma, Andyka ; Lischer, Kenny ; Putra, Wahyuaji Narottama</contributor><creatorcontrib>Septiana, Reski ; Roihan, Ibnu ; Riantono, Arbi ; Juan, K. ; Koestoer, Raldi A. ; Maknun, Imam Jauhari ; Harahap, Yulia Nurliani ; Harwahyu, Ruki ; Ardi, Romadhani ; Fatriansyah, Jaka Fajar ; Irwansyah, Ridho ; Dhelika, Radon ; Pratama, Mochamad Adhiraga ; Kusuma, Andyka ; Lischer, Kenny ; Putra, Wahyuaji Narottama</creatorcontrib><description>The use of air purifier to clean the room with poor ventilation is considered as a fast and common solution to minimize the spread of SARS-CoV-2 nowadays. However, the efficacy of the filter within the air purifier must be tested priorly to ensure the cleanliness of the air, since the size of this novel virus is very small. Inexpensive particulate counter which is common in the market, such as HT-9600 particle counter can be used to test the efficacy of the filter if the device is properly calibrated. This paper aims to calibrate the HTI portable particulate counter to Solair3100 which has been calibrated by NIST using ISO 21501-4 and ISO 17025 standards. Both devices were used to measure the amount of particle in various places to see their characteristic. The same nonlinear trend produced by both devices in reading the amount of particle in different places made the calibration effort can be done. Data used for calibration were the average reading of the number of particles from various conditions. Calibration curve of HT-9600 particle counter was obtained by plotting the average readings of both devices in a single plot. The obtained calibration curve is a non-linear plot which represents the characteristic of particle counter in reading the amount of particle based on its respective size. The obtained calibration function from the curve shows great tendency in reading the right amount of particle in the air with minimum error.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0144594</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Air purification ; Calibration ; Effectiveness ; Portable equipment ; Radiation counters</subject><ispartof>AIP conference proceedings, 2024, Vol.2710 (1)</ispartof><rights>AIP Publishing LLC</rights><rights>2024 AIP Publishing LLC.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/acp/article-lookup/doi/10.1063/5.0144594$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,790,4498,23909,23910,25118,27901,27902,76126</link.rule.ids></links><search><contributor>Maknun, Imam Jauhari</contributor><contributor>Harahap, Yulia Nurliani</contributor><contributor>Harwahyu, Ruki</contributor><contributor>Ardi, Romadhani</contributor><contributor>Fatriansyah, Jaka Fajar</contributor><contributor>Irwansyah, Ridho</contributor><contributor>Dhelika, Radon</contributor><contributor>Pratama, Mochamad Adhiraga</contributor><contributor>Kusuma, Andyka</contributor><contributor>Lischer, Kenny</contributor><contributor>Putra, Wahyuaji Narottama</contributor><creatorcontrib>Septiana, Reski</creatorcontrib><creatorcontrib>Roihan, Ibnu</creatorcontrib><creatorcontrib>Riantono, Arbi</creatorcontrib><creatorcontrib>Juan, K.</creatorcontrib><creatorcontrib>Koestoer, Raldi A.</creatorcontrib><title>Calibration of low-cost portable particulate counter (PC) to standardized-certified PC</title><title>AIP conference proceedings</title><description>The use of air purifier to clean the room with poor ventilation is considered as a fast and common solution to minimize the spread of SARS-CoV-2 nowadays. However, the efficacy of the filter within the air purifier must be tested priorly to ensure the cleanliness of the air, since the size of this novel virus is very small. Inexpensive particulate counter which is common in the market, such as HT-9600 particle counter can be used to test the efficacy of the filter if the device is properly calibrated. This paper aims to calibrate the HTI portable particulate counter to Solair3100 which has been calibrated by NIST using ISO 21501-4 and ISO 17025 standards. Both devices were used to measure the amount of particle in various places to see their characteristic. The same nonlinear trend produced by both devices in reading the amount of particle in different places made the calibration effort can be done. Data used for calibration were the average reading of the number of particles from various conditions. Calibration curve of HT-9600 particle counter was obtained by plotting the average readings of both devices in a single plot. The obtained calibration curve is a non-linear plot which represents the characteristic of particle counter in reading the amount of particle based on its respective size. The obtained calibration function from the curve shows great tendency in reading the right amount of particle in the air with minimum error.</description><subject>Air purification</subject><subject>Calibration</subject><subject>Effectiveness</subject><subject>Portable equipment</subject><subject>Radiation counters</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2024</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNotkEtLxDAUhYMoOI4u_AcBNyp0zLvNUoovGHAWKu7CbZpChtrUJEX011udWV04fJxzz0HonJIVJYrfyBWhQkgtDtCCSkmLUlF1iBaEaFEwwd-P0UlKW0KYLstqgd5q6H0TIfsw4NDhPnwVNqSMxxAzNL3DI8Ts7dRDdtiGacgu4stNfYVzwCnD0EJs_Y9rC-tmsPOuxZv6FB110Cd3tr9L9Hp_91I_Fuvnh6f6dl2MVFWiUK5SLWs6KfT8a2kr6aQkDRUdAOGzWnJtKyusKJu5AFfgbMUAlLakYYrwJbrY-Y4xfE4uZbMNUxzmSMM0Y0oQytRMXe-oZH3-r2rG6D8gfhtKzN9uRpr9bvwXUHJePg</recordid><startdate>20240206</startdate><enddate>20240206</enddate><creator>Septiana, Reski</creator><creator>Roihan, Ibnu</creator><creator>Riantono, Arbi</creator><creator>Juan, K.</creator><creator>Koestoer, Raldi A.</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20240206</creationdate><title>Calibration of low-cost portable particulate counter (PC) to standardized-certified PC</title><author>Septiana, Reski ; Roihan, Ibnu ; Riantono, Arbi ; Juan, K. ; Koestoer, Raldi A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p1684-6e86d2bf5495517c85e550b14faa03549739c8c4c47b09436aec82aa69c0b2603</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Air purification</topic><topic>Calibration</topic><topic>Effectiveness</topic><topic>Portable equipment</topic><topic>Radiation counters</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Septiana, Reski</creatorcontrib><creatorcontrib>Roihan, Ibnu</creatorcontrib><creatorcontrib>Riantono, Arbi</creatorcontrib><creatorcontrib>Juan, K.</creatorcontrib><creatorcontrib>Koestoer, Raldi A.</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Septiana, Reski</au><au>Roihan, Ibnu</au><au>Riantono, Arbi</au><au>Juan, K.</au><au>Koestoer, Raldi A.</au><au>Maknun, Imam Jauhari</au><au>Harahap, Yulia Nurliani</au><au>Harwahyu, Ruki</au><au>Ardi, Romadhani</au><au>Fatriansyah, Jaka Fajar</au><au>Irwansyah, Ridho</au><au>Dhelika, Radon</au><au>Pratama, Mochamad Adhiraga</au><au>Kusuma, Andyka</au><au>Lischer, Kenny</au><au>Putra, Wahyuaji Narottama</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Calibration of low-cost portable particulate counter (PC) to standardized-certified PC</atitle><btitle>AIP conference proceedings</btitle><date>2024-02-06</date><risdate>2024</risdate><volume>2710</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>The use of air purifier to clean the room with poor ventilation is considered as a fast and common solution to minimize the spread of SARS-CoV-2 nowadays. However, the efficacy of the filter within the air purifier must be tested priorly to ensure the cleanliness of the air, since the size of this novel virus is very small. Inexpensive particulate counter which is common in the market, such as HT-9600 particle counter can be used to test the efficacy of the filter if the device is properly calibrated. This paper aims to calibrate the HTI portable particulate counter to Solair3100 which has been calibrated by NIST using ISO 21501-4 and ISO 17025 standards. Both devices were used to measure the amount of particle in various places to see their characteristic. The same nonlinear trend produced by both devices in reading the amount of particle in different places made the calibration effort can be done. Data used for calibration were the average reading of the number of particles from various conditions. Calibration curve of HT-9600 particle counter was obtained by plotting the average readings of both devices in a single plot. The obtained calibration curve is a non-linear plot which represents the characteristic of particle counter in reading the amount of particle based on its respective size. The obtained calibration function from the curve shows great tendency in reading the right amount of particle in the air with minimum error.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0144594</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | AIP conference proceedings, 2024, Vol.2710 (1) |
issn | 0094-243X 1551-7616 |
language | eng |
recordid | cdi_scitation_primary_10_1063_5_0144594 |
source | AIP Journals Complete |
subjects | Air purification Calibration Effectiveness Portable equipment Radiation counters |
title | Calibration of low-cost portable particulate counter (PC) to standardized-certified PC |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T13%3A08%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Calibration%20of%20low-cost%20portable%20particulate%20counter%20(PC)%20to%20standardized-certified%20PC&rft.btitle=AIP%20conference%20proceedings&rft.au=Septiana,%20Reski&rft.date=2024-02-06&rft.volume=2710&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0144594&rft_dat=%3Cproquest_scita%3E2922640126%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2922640126&rft_id=info:pmid/&rfr_iscdi=true |