Structures for mounting reed switches near the busbars of electrical installations with remote control of their position

It is noted that in relay protection resource savings can be achieved by replacing current transformers with ferromagnetic cores with miniature current sensors, such as inductance coils, reed switches, etc. It is emphasized that special designs are required for their mounting near the busbars. Model...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Issabekov, Zhanat B., Mashrapov, Bauyrzhan E., Issaberov, Dauren D., Mashrapova, Gulnara N.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page
container_title
container_volume 2337
creator Issabekov, Zhanat B.
Mashrapov, Bauyrzhan E.
Issaberov, Dauren D.
Mashrapova, Gulnara N.
description It is noted that in relay protection resource savings can be achieved by replacing current transformers with ferromagnetic cores with miniature current sensors, such as inductance coils, reed switches, etc. It is emphasized that special designs are required for their mounting near the busbars. Models of two such designs for mounting reed switches are proposed. The first differs from the known ones by the presence of a single stepper motor connected to a microcontroller, which makes it possible to remotely move the reed switch in the horizontal plane, and the second – two electric motors, which allows you to move the reed switches in the vertical plane. At the same time, the microcontroller is located in the relay compartment of the cell of the complete switchgear, which ensures the safety of service personnel. The method of regulating the position of reed switches in space using the proposed designs is described.
doi_str_mv 10.1063/5.0047151
format Conference Proceeding
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_5_0047151</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2498708121</sourcerecordid><originalsourceid>FETCH-LOGICAL-p253t-30e47a02901ab2a358b02f5a3cf0edd45fff660d15d1b628004b49d65af925f3</originalsourceid><addsrcrecordid>eNp9kbtOwzAUQC0EEqUw8AeW2JBSru3YSUZU8ZIqMdCBzXISm7hK42A7PP4el1ZiY7rDPec-EboksCAg2A1fAOQF4eQIzQjnJCsEEcdoBlDlGc3Z6yk6C2EDQKuiKGfo6yX6qYmT1wEb5_HWTUO0wxv2Wrc4fNrYdCk1aOVx7DSup1ArH7AzWPe6id42qsd2CFH1vYrWDQEnqUv-1kWNGzdE7_odn3Tr8eiC3WHn6MSoPuiLQ5yj9f3devmYrZ4fnpa3q2yknMWMgc4LlaYFomqqGC9roIYr1hjQbZtzY4wQ0BLeklrQMm1f51UruDIV5YbN0dW-7Ojd-6RDlBs3-SF1lDSvygJKQkmirvdUaGz83UKO3m6V_5YfzksuD0eVY2v-gwnI3Rf-BPYDS6B74Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2498708121</pqid></control><display><type>conference_proceeding</type><title>Structures for mounting reed switches near the busbars of electrical installations with remote control of their position</title><source>AIP Journals Complete</source><creator>Issabekov, Zhanat B. ; Mashrapov, Bauyrzhan E. ; Issaberov, Dauren D. ; Mashrapova, Gulnara N.</creator><contributor>Orlova, Evgeniya ; Kuznetsov, Geniy ; Feoktistov, Dmitry</contributor><creatorcontrib>Issabekov, Zhanat B. ; Mashrapov, Bauyrzhan E. ; Issaberov, Dauren D. ; Mashrapova, Gulnara N. ; Orlova, Evgeniya ; Kuznetsov, Geniy ; Feoktistov, Dmitry</creatorcontrib><description>It is noted that in relay protection resource savings can be achieved by replacing current transformers with ferromagnetic cores with miniature current sensors, such as inductance coils, reed switches, etc. It is emphasized that special designs are required for their mounting near the busbars. Models of two such designs for mounting reed switches are proposed. The first differs from the known ones by the presence of a single stepper motor connected to a microcontroller, which makes it possible to remotely move the reed switch in the horizontal plane, and the second – two electric motors, which allows you to move the reed switches in the vertical plane. At the same time, the microcontroller is located in the relay compartment of the cell of the complete switchgear, which ensures the safety of service personnel. The method of regulating the position of reed switches in space using the proposed designs is described.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0047151</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Busbars ; Electric motors ; Electrical installations ; Ferromagnetism ; Inductance coils ; Magnetism ; Microcontrollers ; Relay ; Remote control ; Security management ; Stepping motors ; Switches ; Switchgear</subject><ispartof>AIP Conference Proceedings, 2021, Vol.2337 (1)</ispartof><rights>Author(s)</rights><rights>2021 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/acp/article-lookup/doi/10.1063/5.0047151$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,794,4512,23930,23931,25140,27924,27925,76384</link.rule.ids></links><search><contributor>Orlova, Evgeniya</contributor><contributor>Kuznetsov, Geniy</contributor><contributor>Feoktistov, Dmitry</contributor><creatorcontrib>Issabekov, Zhanat B.</creatorcontrib><creatorcontrib>Mashrapov, Bauyrzhan E.</creatorcontrib><creatorcontrib>Issaberov, Dauren D.</creatorcontrib><creatorcontrib>Mashrapova, Gulnara N.</creatorcontrib><title>Structures for mounting reed switches near the busbars of electrical installations with remote control of their position</title><title>AIP Conference Proceedings</title><description>It is noted that in relay protection resource savings can be achieved by replacing current transformers with ferromagnetic cores with miniature current sensors, such as inductance coils, reed switches, etc. It is emphasized that special designs are required for their mounting near the busbars. Models of two such designs for mounting reed switches are proposed. The first differs from the known ones by the presence of a single stepper motor connected to a microcontroller, which makes it possible to remotely move the reed switch in the horizontal plane, and the second – two electric motors, which allows you to move the reed switches in the vertical plane. At the same time, the microcontroller is located in the relay compartment of the cell of the complete switchgear, which ensures the safety of service personnel. The method of regulating the position of reed switches in space using the proposed designs is described.</description><subject>Busbars</subject><subject>Electric motors</subject><subject>Electrical installations</subject><subject>Ferromagnetism</subject><subject>Inductance coils</subject><subject>Magnetism</subject><subject>Microcontrollers</subject><subject>Relay</subject><subject>Remote control</subject><subject>Security management</subject><subject>Stepping motors</subject><subject>Switches</subject><subject>Switchgear</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2021</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNp9kbtOwzAUQC0EEqUw8AeW2JBSru3YSUZU8ZIqMdCBzXISm7hK42A7PP4el1ZiY7rDPec-EboksCAg2A1fAOQF4eQIzQjnJCsEEcdoBlDlGc3Z6yk6C2EDQKuiKGfo6yX6qYmT1wEb5_HWTUO0wxv2Wrc4fNrYdCk1aOVx7DSup1ArH7AzWPe6id42qsd2CFH1vYrWDQEnqUv-1kWNGzdE7_odn3Tr8eiC3WHn6MSoPuiLQ5yj9f3devmYrZ4fnpa3q2yknMWMgc4LlaYFomqqGC9roIYr1hjQbZtzY4wQ0BLeklrQMm1f51UruDIV5YbN0dW-7Ojd-6RDlBs3-SF1lDSvygJKQkmirvdUaGz83UKO3m6V_5YfzksuD0eVY2v-gwnI3Rf-BPYDS6B74Q</recordid><startdate>20210308</startdate><enddate>20210308</enddate><creator>Issabekov, Zhanat B.</creator><creator>Mashrapov, Bauyrzhan E.</creator><creator>Issaberov, Dauren D.</creator><creator>Mashrapova, Gulnara N.</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20210308</creationdate><title>Structures for mounting reed switches near the busbars of electrical installations with remote control of their position</title><author>Issabekov, Zhanat B. ; Mashrapov, Bauyrzhan E. ; Issaberov, Dauren D. ; Mashrapova, Gulnara N.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p253t-30e47a02901ab2a358b02f5a3cf0edd45fff660d15d1b628004b49d65af925f3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Busbars</topic><topic>Electric motors</topic><topic>Electrical installations</topic><topic>Ferromagnetism</topic><topic>Inductance coils</topic><topic>Magnetism</topic><topic>Microcontrollers</topic><topic>Relay</topic><topic>Remote control</topic><topic>Security management</topic><topic>Stepping motors</topic><topic>Switches</topic><topic>Switchgear</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Issabekov, Zhanat B.</creatorcontrib><creatorcontrib>Mashrapov, Bauyrzhan E.</creatorcontrib><creatorcontrib>Issaberov, Dauren D.</creatorcontrib><creatorcontrib>Mashrapova, Gulnara N.</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Issabekov, Zhanat B.</au><au>Mashrapov, Bauyrzhan E.</au><au>Issaberov, Dauren D.</au><au>Mashrapova, Gulnara N.</au><au>Orlova, Evgeniya</au><au>Kuznetsov, Geniy</au><au>Feoktistov, Dmitry</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Structures for mounting reed switches near the busbars of electrical installations with remote control of their position</atitle><btitle>AIP Conference Proceedings</btitle><date>2021-03-08</date><risdate>2021</risdate><volume>2337</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>It is noted that in relay protection resource savings can be achieved by replacing current transformers with ferromagnetic cores with miniature current sensors, such as inductance coils, reed switches, etc. It is emphasized that special designs are required for their mounting near the busbars. Models of two such designs for mounting reed switches are proposed. The first differs from the known ones by the presence of a single stepper motor connected to a microcontroller, which makes it possible to remotely move the reed switch in the horizontal plane, and the second – two electric motors, which allows you to move the reed switches in the vertical plane. At the same time, the microcontroller is located in the relay compartment of the cell of the complete switchgear, which ensures the safety of service personnel. The method of regulating the position of reed switches in space using the proposed designs is described.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0047151</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP Conference Proceedings, 2021, Vol.2337 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_scitation_primary_10_1063_5_0047151
source AIP Journals Complete
subjects Busbars
Electric motors
Electrical installations
Ferromagnetism
Inductance coils
Magnetism
Microcontrollers
Relay
Remote control
Security management
Stepping motors
Switches
Switchgear
title Structures for mounting reed switches near the busbars of electrical installations with remote control of their position
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T04%3A49%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Structures%20for%20mounting%20reed%20switches%20near%20the%20busbars%20of%20electrical%20installations%20with%20remote%20control%20of%20their%20position&rft.btitle=AIP%20Conference%20Proceedings&rft.au=Issabekov,%20Zhanat%20B.&rft.date=2021-03-08&rft.volume=2337&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0047151&rft_dat=%3Cproquest_scita%3E2498708121%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2498708121&rft_id=info:pmid/&rfr_iscdi=true