Design and analysis of magnetostrictive sensors for wireless temperature sensing

Magnetostrictive transducers are commonly used as actuators and sonar transducers, and in remote non-destructive evaluation. Their use in wireless thermometry is relatively unexplored. Since magnetostriction-based sensors are passive, they could potentially enable long-term near-field thermometry. W...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2021-01, Vol.92 (1), p.014901-014901
Hauptverfasser: Rajagopal, Manjunath C., Sinha, Sanjiv
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 014901
container_issue 1
container_start_page 014901
container_title Review of scientific instruments
container_volume 92
creator Rajagopal, Manjunath C.
Sinha, Sanjiv
description Magnetostrictive transducers are commonly used as actuators and sonar transducers, and in remote non-destructive evaluation. Their use in wireless thermometry is relatively unexplored. Since magnetostriction-based sensors are passive, they could potentially enable long-term near-field thermometry. While the temperature sensitivity of resonance frequency in magnetostrictive transducers has been reported in previous studies, the origin of the temperature sensitivity has, however, not been elucidated. Here, we identify material properties that determine temperature sensitivity and identify ways to improve sensitivity as well as the detection technique. Using a combination of analytical and computational methods, we systematically identify the material properties that directly influence the temperature coefficient of resonance frequency (TCF). We first experimentally measure the shift in resonance frequency due to temperature changes in a Metglas strip to be 0.03% K−1. Using insights from theory, we then experimentally demonstrate a fivefold improvement to the TCF by using Terfenol in place of Metglas as the magnetostrictive sensor material. We further demonstrate an alternate temperature sensing technique that does not require measuring the resonance frequency, consequently reducing instrument complexity. This work provides a general framework to analyze magnetostrictive materials and the sensing scheme for near-field wireless thermometry.
doi_str_mv 10.1063/5.0035296
format Article
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_5_0035296</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2477809355</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-c001afb09f0960f1c21b0e2694427ff51f19e1107366928150bcedd31ef7395a3</originalsourceid><addsrcrecordid>eNp90E1r20AQBuCltDSO00P-QBD0khTkzGi1kvYY3I8UDMkhPYu1PGvWSFp3Z9Xgfx8ZOTn0kIVhYXh4YV4hLhEWCIW8VQsAqTJdfBAzhEqnZZHJj2I2bvO0KPPqTJwz72B8CvGzOJNSYZ5BPhOP34ndtk9MvxnHtAd2nHibdGbbU_Qcg2ui-0cJU88-cGJ9SJ5doJaYk0jdnoKJQ5iA67cX4pM1LdOX0z8Xf37-eFrep6uHX7-Xd6u0kZWMaQOAxq5BW9AFWGwyXANlhc7zrLRWoUVNiFDKotBZhQrWDW02EsmWUisj5-J6yt0H_3cgjnXnuKG2NT35gessr2SFeGxiLr7-R3d-COOxR1WWFWip1KhuJtUEzxzI1vvgOhMONUJ9rLlW9anm0V6dEod1R5s3-drrCL5NgBsXTXS-fyftBZ1gg7c</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2477809355</pqid></control><display><type>article</type><title>Design and analysis of magnetostrictive sensors for wireless temperature sensing</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Rajagopal, Manjunath C. ; Sinha, Sanjiv</creator><creatorcontrib>Rajagopal, Manjunath C. ; Sinha, Sanjiv</creatorcontrib><description>Magnetostrictive transducers are commonly used as actuators and sonar transducers, and in remote non-destructive evaluation. Their use in wireless thermometry is relatively unexplored. Since magnetostriction-based sensors are passive, they could potentially enable long-term near-field thermometry. While the temperature sensitivity of resonance frequency in magnetostrictive transducers has been reported in previous studies, the origin of the temperature sensitivity has, however, not been elucidated. Here, we identify material properties that determine temperature sensitivity and identify ways to improve sensitivity as well as the detection technique. Using a combination of analytical and computational methods, we systematically identify the material properties that directly influence the temperature coefficient of resonance frequency (TCF). We first experimentally measure the shift in resonance frequency due to temperature changes in a Metglas strip to be 0.03% K−1. Using insights from theory, we then experimentally demonstrate a fivefold improvement to the TCF by using Terfenol in place of Metglas as the magnetostrictive sensor material. We further demonstrate an alternate temperature sensing technique that does not require measuring the resonance frequency, consequently reducing instrument complexity. This work provides a general framework to analyze magnetostrictive materials and the sensing scheme for near-field wireless thermometry.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/5.0035296</identifier><identifier>PMID: 33514204</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><subject>Actuators ; Magnetostriction ; Material properties ; Near fields ; Nondestructive testing ; Resonance ; Scientific apparatus &amp; instruments ; Sensors ; Temperature ; Transducers</subject><ispartof>Review of scientific instruments, 2021-01, Vol.92 (1), p.014901-014901</ispartof><rights>Author(s)</rights><rights>2021 Author(s). Published under license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-c001afb09f0960f1c21b0e2694427ff51f19e1107366928150bcedd31ef7395a3</citedby><cites>FETCH-LOGICAL-c383t-c001afb09f0960f1c21b0e2694427ff51f19e1107366928150bcedd31ef7395a3</cites><orcidid>0000-0001-7230-2946 ; 0000-0002-8096-8462 ; 0000000280968462 ; 0000000172302946</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/5.0035296$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,794,4512,27924,27925,76384</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33514204$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rajagopal, Manjunath C.</creatorcontrib><creatorcontrib>Sinha, Sanjiv</creatorcontrib><title>Design and analysis of magnetostrictive sensors for wireless temperature sensing</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>Magnetostrictive transducers are commonly used as actuators and sonar transducers, and in remote non-destructive evaluation. Their use in wireless thermometry is relatively unexplored. Since magnetostriction-based sensors are passive, they could potentially enable long-term near-field thermometry. While the temperature sensitivity of resonance frequency in magnetostrictive transducers has been reported in previous studies, the origin of the temperature sensitivity has, however, not been elucidated. Here, we identify material properties that determine temperature sensitivity and identify ways to improve sensitivity as well as the detection technique. Using a combination of analytical and computational methods, we systematically identify the material properties that directly influence the temperature coefficient of resonance frequency (TCF). We first experimentally measure the shift in resonance frequency due to temperature changes in a Metglas strip to be 0.03% K−1. Using insights from theory, we then experimentally demonstrate a fivefold improvement to the TCF by using Terfenol in place of Metglas as the magnetostrictive sensor material. We further demonstrate an alternate temperature sensing technique that does not require measuring the resonance frequency, consequently reducing instrument complexity. This work provides a general framework to analyze magnetostrictive materials and the sensing scheme for near-field wireless thermometry.</description><subject>Actuators</subject><subject>Magnetostriction</subject><subject>Material properties</subject><subject>Near fields</subject><subject>Nondestructive testing</subject><subject>Resonance</subject><subject>Scientific apparatus &amp; instruments</subject><subject>Sensors</subject><subject>Temperature</subject><subject>Transducers</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp90E1r20AQBuCltDSO00P-QBD0khTkzGi1kvYY3I8UDMkhPYu1PGvWSFp3Z9Xgfx8ZOTn0kIVhYXh4YV4hLhEWCIW8VQsAqTJdfBAzhEqnZZHJj2I2bvO0KPPqTJwz72B8CvGzOJNSYZ5BPhOP34ndtk9MvxnHtAd2nHibdGbbU_Qcg2ui-0cJU88-cGJ9SJ5doJaYk0jdnoKJQ5iA67cX4pM1LdOX0z8Xf37-eFrep6uHX7-Xd6u0kZWMaQOAxq5BW9AFWGwyXANlhc7zrLRWoUVNiFDKotBZhQrWDW02EsmWUisj5-J6yt0H_3cgjnXnuKG2NT35gessr2SFeGxiLr7-R3d-COOxR1WWFWip1KhuJtUEzxzI1vvgOhMONUJ9rLlW9anm0V6dEod1R5s3-drrCL5NgBsXTXS-fyftBZ1gg7c</recordid><startdate>20210101</startdate><enddate>20210101</enddate><creator>Rajagopal, Manjunath C.</creator><creator>Sinha, Sanjiv</creator><general>American Institute of Physics</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-7230-2946</orcidid><orcidid>https://orcid.org/0000-0002-8096-8462</orcidid><orcidid>https://orcid.org/0000000280968462</orcidid><orcidid>https://orcid.org/0000000172302946</orcidid></search><sort><creationdate>20210101</creationdate><title>Design and analysis of magnetostrictive sensors for wireless temperature sensing</title><author>Rajagopal, Manjunath C. ; Sinha, Sanjiv</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-c001afb09f0960f1c21b0e2694427ff51f19e1107366928150bcedd31ef7395a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Actuators</topic><topic>Magnetostriction</topic><topic>Material properties</topic><topic>Near fields</topic><topic>Nondestructive testing</topic><topic>Resonance</topic><topic>Scientific apparatus &amp; instruments</topic><topic>Sensors</topic><topic>Temperature</topic><topic>Transducers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rajagopal, Manjunath C.</creatorcontrib><creatorcontrib>Sinha, Sanjiv</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rajagopal, Manjunath C.</au><au>Sinha, Sanjiv</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and analysis of magnetostrictive sensors for wireless temperature sensing</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2021-01-01</date><risdate>2021</risdate><volume>92</volume><issue>1</issue><spage>014901</spage><epage>014901</epage><pages>014901-014901</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Magnetostrictive transducers are commonly used as actuators and sonar transducers, and in remote non-destructive evaluation. Their use in wireless thermometry is relatively unexplored. Since magnetostriction-based sensors are passive, they could potentially enable long-term near-field thermometry. While the temperature sensitivity of resonance frequency in magnetostrictive transducers has been reported in previous studies, the origin of the temperature sensitivity has, however, not been elucidated. Here, we identify material properties that determine temperature sensitivity and identify ways to improve sensitivity as well as the detection technique. Using a combination of analytical and computational methods, we systematically identify the material properties that directly influence the temperature coefficient of resonance frequency (TCF). We first experimentally measure the shift in resonance frequency due to temperature changes in a Metglas strip to be 0.03% K−1. Using insights from theory, we then experimentally demonstrate a fivefold improvement to the TCF by using Terfenol in place of Metglas as the magnetostrictive sensor material. We further demonstrate an alternate temperature sensing technique that does not require measuring the resonance frequency, consequently reducing instrument complexity. This work provides a general framework to analyze magnetostrictive materials and the sensing scheme for near-field wireless thermometry.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>33514204</pmid><doi>10.1063/5.0035296</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0001-7230-2946</orcidid><orcidid>https://orcid.org/0000-0002-8096-8462</orcidid><orcidid>https://orcid.org/0000000280968462</orcidid><orcidid>https://orcid.org/0000000172302946</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2021-01, Vol.92 (1), p.014901-014901
issn 0034-6748
1089-7623
language eng
recordid cdi_scitation_primary_10_1063_5_0035296
source AIP Journals Complete; Alma/SFX Local Collection
subjects Actuators
Magnetostriction
Material properties
Near fields
Nondestructive testing
Resonance
Scientific apparatus & instruments
Sensors
Temperature
Transducers
title Design and analysis of magnetostrictive sensors for wireless temperature sensing
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T20%3A12%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20analysis%20of%20magnetostrictive%20sensors%20for%20wireless%20temperature%20sensing&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Rajagopal,%20Manjunath%20C.&rft.date=2021-01-01&rft.volume=92&rft.issue=1&rft.spage=014901&rft.epage=014901&rft.pages=014901-014901&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/5.0035296&rft_dat=%3Cproquest_scita%3E2477809355%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2477809355&rft_id=info:pmid/33514204&rfr_iscdi=true