The effect of DC-bias plasma oxygen on the surface chemistry of polystyrene thin film analysis by optical emission spectroscopy

Plasma has been known as one method for surface functionalization of a polymer. Surface functionalization of the polymer film as a sensitive material as well as matrix material is essential in a chemical sensor and biosensor. This work shows the effects of oxygen plasma generated using a radio frequ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Arinda, Putri S., Hanif, Mahardika A., Sandtjojo, D. J. Djoko H., Sakti, Setyawan P.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page
container_title
container_volume 2296
creator Arinda, Putri S.
Hanif, Mahardika A.
Sandtjojo, D. J. Djoko H.
Sakti, Setyawan P.
description Plasma has been known as one method for surface functionalization of a polymer. Surface functionalization of the polymer film as a sensitive material as well as matrix material is essential in a chemical sensor and biosensor. This work shows the effects of oxygen plasma generated using a radio frequency plasma (RF plasma) system to the polystyrene film on top of the Quartz Crystal Microbalance (QCM) sensor. Polystyrene with a molecular weight of 35kD was coated on the QCM sensor surface using a spin coating method. The sensor with the coated film was treated in an oxygen plasma generated using the RF-DC plasma system. A DC bias of high-density RF-DC plasma generator voltage was variated from -150 to -550 V. The RF generator voltage was maintained at 100V. The surface changed of the Polystyrene caused by DC-bias of the oxygen plasma was investigated. The effect of the generated oxygen plasma to the polystyrene surface was analyzed using optical emission spectroscopy method with wavelength range of 200-1100 nm. The emission spectroscopy data showed the existence of CO species besides the acivated oxygen atom (844 nm and 776 nm) and oxygen ion (525 nm, 529 nm, and 654 nm). The FTIR data of the plasma-treated polystyrene film showed the existence of a polar functional group. The transmittance value of the FTIR spectrum after plasma treatment decreased with increasing DC bias. The change relates to the chain scission of the C-C and C-H bond of the polystyrene film.
doi_str_mv 10.1063/5.0030565
format Conference Proceeding
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_5_0030565</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2460868437</sourcerecordid><originalsourceid>FETCH-LOGICAL-p253t-ffa5c724a5cb6dbacd3c7822c7b5388a4bde262c45b4b596ae2fc32d7f688d973</originalsourceid><addsrcrecordid>eNotkM1KxDAUhYMoOI4ufIOAO6FjmjRJu5TxFwbcjOCuJGniZGibmGTArnx1U2Y298LlO-ceDgC3JVqViJEHukKIIMroGViUlJYFZyU7BwuEmqrAFfm6BFcx7hHCDef1AvxtdxpqY7RK0Bn4tC6kFRH6XsRBQPc7fesRuhGmjMVDMEJpqHZ6sDGFaVZ4108xTUGPOkN2hMb2AxSjyGcbocyQT1aJHs6iaLNX9PlbcFE5P12DCyP6qG9Oewk-X56367di8_H6vn7cFB5TkgpjBFUcV3lK1kmhOqJ4jbHikpK6FpXsNGZYVVRWkjZMaGwUwR03rK67hpMluDv6-uB-Djqmdu8OIaeMLa4YqlldkZm6P1JR2SRSDtv6YAcRprZE7VxwS9tTweQfyppwEw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2460868437</pqid></control><display><type>conference_proceeding</type><title>The effect of DC-bias plasma oxygen on the surface chemistry of polystyrene thin film analysis by optical emission spectroscopy</title><source>AIP Journals Complete</source><creator>Arinda, Putri S. ; Hanif, Mahardika A. ; Sandtjojo, D. J. Djoko H. ; Sakti, Setyawan P.</creator><contributor>Purnama, Budi ; Nugraha, Dewanta Arya ; Anwar, Fuad</contributor><creatorcontrib>Arinda, Putri S. ; Hanif, Mahardika A. ; Sandtjojo, D. J. Djoko H. ; Sakti, Setyawan P. ; Purnama, Budi ; Nugraha, Dewanta Arya ; Anwar, Fuad</creatorcontrib><description>Plasma has been known as one method for surface functionalization of a polymer. Surface functionalization of the polymer film as a sensitive material as well as matrix material is essential in a chemical sensor and biosensor. This work shows the effects of oxygen plasma generated using a radio frequency plasma (RF plasma) system to the polystyrene film on top of the Quartz Crystal Microbalance (QCM) sensor. Polystyrene with a molecular weight of 35kD was coated on the QCM sensor surface using a spin coating method. The sensor with the coated film was treated in an oxygen plasma generated using the RF-DC plasma system. A DC bias of high-density RF-DC plasma generator voltage was variated from -150 to -550 V. The RF generator voltage was maintained at 100V. The surface changed of the Polystyrene caused by DC-bias of the oxygen plasma was investigated. The effect of the generated oxygen plasma to the polystyrene surface was analyzed using optical emission spectroscopy method with wavelength range of 200-1100 nm. The emission spectroscopy data showed the existence of CO species besides the acivated oxygen atom (844 nm and 776 nm) and oxygen ion (525 nm, 529 nm, and 654 nm). The FTIR data of the plasma-treated polystyrene film showed the existence of a polar functional group. The transmittance value of the FTIR spectrum after plasma treatment decreased with increasing DC bias. The change relates to the chain scission of the C-C and C-H bond of the polystyrene film.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0030565</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Atmospheric pressure ; Bias ; Biosensors ; Chain scission ; Chemical sensors ; Electric potential ; Emission analysis ; Emission spectroscopy ; Functional groups ; Hydrogen bonds ; Microbalances ; Optical emission spectroscopy ; Oxygen ions ; Oxygen plasma ; Plasma generators ; Polymer films ; Polystyrene resins ; Quartz crystals ; Radio frequency ; Radio frequency plasma ; Sensors ; Spectroscopic analysis ; Spin coating ; Thin films ; Voltage</subject><ispartof>AIP conference proceedings, 2020, Vol.2296 (1)</ispartof><rights>Author(s)</rights><rights>2020 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/acp/article-lookup/doi/10.1063/5.0030565$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,790,4497,23910,23911,25119,27903,27904,76130</link.rule.ids></links><search><contributor>Purnama, Budi</contributor><contributor>Nugraha, Dewanta Arya</contributor><contributor>Anwar, Fuad</contributor><creatorcontrib>Arinda, Putri S.</creatorcontrib><creatorcontrib>Hanif, Mahardika A.</creatorcontrib><creatorcontrib>Sandtjojo, D. J. Djoko H.</creatorcontrib><creatorcontrib>Sakti, Setyawan P.</creatorcontrib><title>The effect of DC-bias plasma oxygen on the surface chemistry of polystyrene thin film analysis by optical emission spectroscopy</title><title>AIP conference proceedings</title><description>Plasma has been known as one method for surface functionalization of a polymer. Surface functionalization of the polymer film as a sensitive material as well as matrix material is essential in a chemical sensor and biosensor. This work shows the effects of oxygen plasma generated using a radio frequency plasma (RF plasma) system to the polystyrene film on top of the Quartz Crystal Microbalance (QCM) sensor. Polystyrene with a molecular weight of 35kD was coated on the QCM sensor surface using a spin coating method. The sensor with the coated film was treated in an oxygen plasma generated using the RF-DC plasma system. A DC bias of high-density RF-DC plasma generator voltage was variated from -150 to -550 V. The RF generator voltage was maintained at 100V. The surface changed of the Polystyrene caused by DC-bias of the oxygen plasma was investigated. The effect of the generated oxygen plasma to the polystyrene surface was analyzed using optical emission spectroscopy method with wavelength range of 200-1100 nm. The emission spectroscopy data showed the existence of CO species besides the acivated oxygen atom (844 nm and 776 nm) and oxygen ion (525 nm, 529 nm, and 654 nm). The FTIR data of the plasma-treated polystyrene film showed the existence of a polar functional group. The transmittance value of the FTIR spectrum after plasma treatment decreased with increasing DC bias. The change relates to the chain scission of the C-C and C-H bond of the polystyrene film.</description><subject>Atmospheric pressure</subject><subject>Bias</subject><subject>Biosensors</subject><subject>Chain scission</subject><subject>Chemical sensors</subject><subject>Electric potential</subject><subject>Emission analysis</subject><subject>Emission spectroscopy</subject><subject>Functional groups</subject><subject>Hydrogen bonds</subject><subject>Microbalances</subject><subject>Optical emission spectroscopy</subject><subject>Oxygen ions</subject><subject>Oxygen plasma</subject><subject>Plasma generators</subject><subject>Polymer films</subject><subject>Polystyrene resins</subject><subject>Quartz crystals</subject><subject>Radio frequency</subject><subject>Radio frequency plasma</subject><subject>Sensors</subject><subject>Spectroscopic analysis</subject><subject>Spin coating</subject><subject>Thin films</subject><subject>Voltage</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2020</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNotkM1KxDAUhYMoOI4ufIOAO6FjmjRJu5TxFwbcjOCuJGniZGibmGTArnx1U2Y298LlO-ceDgC3JVqViJEHukKIIMroGViUlJYFZyU7BwuEmqrAFfm6BFcx7hHCDef1AvxtdxpqY7RK0Bn4tC6kFRH6XsRBQPc7fesRuhGmjMVDMEJpqHZ6sDGFaVZ4108xTUGPOkN2hMb2AxSjyGcbocyQT1aJHs6iaLNX9PlbcFE5P12DCyP6qG9Oewk-X56367di8_H6vn7cFB5TkgpjBFUcV3lK1kmhOqJ4jbHikpK6FpXsNGZYVVRWkjZMaGwUwR03rK67hpMluDv6-uB-Djqmdu8OIaeMLa4YqlldkZm6P1JR2SRSDtv6YAcRprZE7VxwS9tTweQfyppwEw</recordid><startdate>20201116</startdate><enddate>20201116</enddate><creator>Arinda, Putri S.</creator><creator>Hanif, Mahardika A.</creator><creator>Sandtjojo, D. J. Djoko H.</creator><creator>Sakti, Setyawan P.</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20201116</creationdate><title>The effect of DC-bias plasma oxygen on the surface chemistry of polystyrene thin film analysis by optical emission spectroscopy</title><author>Arinda, Putri S. ; Hanif, Mahardika A. ; Sandtjojo, D. J. Djoko H. ; Sakti, Setyawan P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p253t-ffa5c724a5cb6dbacd3c7822c7b5388a4bde262c45b4b596ae2fc32d7f688d973</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Atmospheric pressure</topic><topic>Bias</topic><topic>Biosensors</topic><topic>Chain scission</topic><topic>Chemical sensors</topic><topic>Electric potential</topic><topic>Emission analysis</topic><topic>Emission spectroscopy</topic><topic>Functional groups</topic><topic>Hydrogen bonds</topic><topic>Microbalances</topic><topic>Optical emission spectroscopy</topic><topic>Oxygen ions</topic><topic>Oxygen plasma</topic><topic>Plasma generators</topic><topic>Polymer films</topic><topic>Polystyrene resins</topic><topic>Quartz crystals</topic><topic>Radio frequency</topic><topic>Radio frequency plasma</topic><topic>Sensors</topic><topic>Spectroscopic analysis</topic><topic>Spin coating</topic><topic>Thin films</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Arinda, Putri S.</creatorcontrib><creatorcontrib>Hanif, Mahardika A.</creatorcontrib><creatorcontrib>Sandtjojo, D. J. Djoko H.</creatorcontrib><creatorcontrib>Sakti, Setyawan P.</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Arinda, Putri S.</au><au>Hanif, Mahardika A.</au><au>Sandtjojo, D. J. Djoko H.</au><au>Sakti, Setyawan P.</au><au>Purnama, Budi</au><au>Nugraha, Dewanta Arya</au><au>Anwar, Fuad</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>The effect of DC-bias plasma oxygen on the surface chemistry of polystyrene thin film analysis by optical emission spectroscopy</atitle><btitle>AIP conference proceedings</btitle><date>2020-11-16</date><risdate>2020</risdate><volume>2296</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>Plasma has been known as one method for surface functionalization of a polymer. Surface functionalization of the polymer film as a sensitive material as well as matrix material is essential in a chemical sensor and biosensor. This work shows the effects of oxygen plasma generated using a radio frequency plasma (RF plasma) system to the polystyrene film on top of the Quartz Crystal Microbalance (QCM) sensor. Polystyrene with a molecular weight of 35kD was coated on the QCM sensor surface using a spin coating method. The sensor with the coated film was treated in an oxygen plasma generated using the RF-DC plasma system. A DC bias of high-density RF-DC plasma generator voltage was variated from -150 to -550 V. The RF generator voltage was maintained at 100V. The surface changed of the Polystyrene caused by DC-bias of the oxygen plasma was investigated. The effect of the generated oxygen plasma to the polystyrene surface was analyzed using optical emission spectroscopy method with wavelength range of 200-1100 nm. The emission spectroscopy data showed the existence of CO species besides the acivated oxygen atom (844 nm and 776 nm) and oxygen ion (525 nm, 529 nm, and 654 nm). The FTIR data of the plasma-treated polystyrene film showed the existence of a polar functional group. The transmittance value of the FTIR spectrum after plasma treatment decreased with increasing DC bias. The change relates to the chain scission of the C-C and C-H bond of the polystyrene film.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0030565</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP conference proceedings, 2020, Vol.2296 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_scitation_primary_10_1063_5_0030565
source AIP Journals Complete
subjects Atmospheric pressure
Bias
Biosensors
Chain scission
Chemical sensors
Electric potential
Emission analysis
Emission spectroscopy
Functional groups
Hydrogen bonds
Microbalances
Optical emission spectroscopy
Oxygen ions
Oxygen plasma
Plasma generators
Polymer films
Polystyrene resins
Quartz crystals
Radio frequency
Radio frequency plasma
Sensors
Spectroscopic analysis
Spin coating
Thin films
Voltage
title The effect of DC-bias plasma oxygen on the surface chemistry of polystyrene thin film analysis by optical emission spectroscopy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T17%3A01%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=The%20effect%20of%20DC-bias%20plasma%20oxygen%20on%20the%20surface%20chemistry%20of%20polystyrene%20thin%20film%20analysis%20by%20optical%20emission%20spectroscopy&rft.btitle=AIP%20conference%20proceedings&rft.au=Arinda,%20Putri%20S.&rft.date=2020-11-16&rft.volume=2296&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0030565&rft_dat=%3Cproquest_scita%3E2460868437%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2460868437&rft_id=info:pmid/&rfr_iscdi=true