Theoretical and experimental studies on broadband photoacoustic response of surface plasmon sensing
The surface plasmon (SP) sensing technique demonstrates high sensitivity and a broad bandwidth of measuring photoacoustic (PA) pressure transients. In this work, we further present a systematic investigation on PA response characteristics of the recently developed SP-based ultrasonic detector, where...
Gespeichert in:
Veröffentlicht in: | Applied physics letters 2020-06, Vol.116 (24) |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 24 |
container_start_page | |
container_title | Applied physics letters |
container_volume | 116 |
creator | Song, Wei Xiao, Sijie Min, Changjun Fang, Hui Yuan, Xiaocong |
description | The surface plasmon (SP) sensing technique demonstrates high sensitivity and a broad bandwidth of measuring photoacoustic (PA) pressure transients. In this work, we further present a systematic investigation on PA response characteristics of the recently developed SP-based ultrasonic detector, where the ensemble of surface plasmon polaritons (SPPs) at the metal-dielectric interface is approximated as an equivalent acoustic detector. Relying on the intrinsically ultrafast temporal response (∼140 fs) and highly localized evanescent field (optical penetration depth of ∼185 nm) of the SPPs, the SP sensing can respond ultrasounds with the gigahertz frequency band theoretically, which, however, is far higher than the bandwidth in practical PA detection. We reveal that, due to acoustic interference, the finite lateral probing dimension in the SP sensor imposes an ultimate constraint on the accessible ultrasonic cutoff frequency, representing good agreement with the experimental results by acquiring PA impulses from an optically absorbing graphene film using our SP sensor. The theoretical framework enables analyzing the SP response characteristics of ultrasonic/PA pressure transients, which, therefore, offers guidelines for configuring the SP sensor with adequate sensitivity and bandwidths to access various biomedical PA applications, including volumetric imaging and spectroscopic analysis. |
doi_str_mv | 10.1063/5.0004217 |
format | Article |
fullrecord | <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_5_0004217</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2413771513</sourcerecordid><originalsourceid>FETCH-LOGICAL-c327t-8bdc2b8e761c8183afaac8ec73edbbe1d2026f5147634269c735afb2f432df0e3</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMoWKsH_8GCJ4Wt-djdbI9S_IKCl3oO2WRiV2qyZrKi_96UFj0InoaZed53mJeQc0ZnjDbiup5RSivO5AGZMCplKRhrD8kkT0XZzGt2TE4QX3NbcyEmxKzWECKk3uhNob0t4HOA2L-BT3mAabQ9YBF80cWgbbclhnVIQZswYlYVEXAIHqEIrsAxOm2gGDYa37IGwWPvX07JkdMbhLN9nZLnu9vV4qFcPt0_Lm6WpRFcprLtrOFdC7JhpmWt0E5r04KRAmzXAbOc8sbVrJKNqHgzz4tau467SnDrKIgpudj5DjG8j4BJvYYx-nxS8YoJKVnNRKYud5SJATGCU0P-V8cvxajaZqhqtc8ws1c7Fk2fdOqD_4E_QvwF1WDdf_Bf529pD4Gt</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2413771513</pqid></control><display><type>article</type><title>Theoretical and experimental studies on broadband photoacoustic response of surface plasmon sensing</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Song, Wei ; Xiao, Sijie ; Min, Changjun ; Fang, Hui ; Yuan, Xiaocong</creator><creatorcontrib>Song, Wei ; Xiao, Sijie ; Min, Changjun ; Fang, Hui ; Yuan, Xiaocong</creatorcontrib><description>The surface plasmon (SP) sensing technique demonstrates high sensitivity and a broad bandwidth of measuring photoacoustic (PA) pressure transients. In this work, we further present a systematic investigation on PA response characteristics of the recently developed SP-based ultrasonic detector, where the ensemble of surface plasmon polaritons (SPPs) at the metal-dielectric interface is approximated as an equivalent acoustic detector. Relying on the intrinsically ultrafast temporal response (∼140 fs) and highly localized evanescent field (optical penetration depth of ∼185 nm) of the SPPs, the SP sensing can respond ultrasounds with the gigahertz frequency band theoretically, which, however, is far higher than the bandwidth in practical PA detection. We reveal that, due to acoustic interference, the finite lateral probing dimension in the SP sensor imposes an ultimate constraint on the accessible ultrasonic cutoff frequency, representing good agreement with the experimental results by acquiring PA impulses from an optically absorbing graphene film using our SP sensor. The theoretical framework enables analyzing the SP response characteristics of ultrasonic/PA pressure transients, which, therefore, offers guidelines for configuring the SP sensor with adequate sensitivity and bandwidths to access various biomedical PA applications, including volumetric imaging and spectroscopic analysis.</description><identifier>ISSN: 0003-6951</identifier><identifier>EISSN: 1077-3118</identifier><identifier>DOI: 10.1063/5.0004217</identifier><identifier>CODEN: APPLAB</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Applied physics ; Bandwidths ; Broadband ; Detection ; Frequencies ; Graphene ; Penetration depth ; Polaritons ; Sensitivity ; Sensors</subject><ispartof>Applied physics letters, 2020-06, Vol.116 (24)</ispartof><rights>Author(s)</rights><rights>2020 Author(s). Published under license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c327t-8bdc2b8e761c8183afaac8ec73edbbe1d2026f5147634269c735afb2f432df0e3</citedby><cites>FETCH-LOGICAL-c327t-8bdc2b8e761c8183afaac8ec73edbbe1d2026f5147634269c735afb2f432df0e3</cites><orcidid>0000-0002-4764-9988 ; 0000-0002-6021-5535</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/apl/article-lookup/doi/10.1063/5.0004217$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,776,780,790,4498,27901,27902,76127</link.rule.ids></links><search><creatorcontrib>Song, Wei</creatorcontrib><creatorcontrib>Xiao, Sijie</creatorcontrib><creatorcontrib>Min, Changjun</creatorcontrib><creatorcontrib>Fang, Hui</creatorcontrib><creatorcontrib>Yuan, Xiaocong</creatorcontrib><title>Theoretical and experimental studies on broadband photoacoustic response of surface plasmon sensing</title><title>Applied physics letters</title><description>The surface plasmon (SP) sensing technique demonstrates high sensitivity and a broad bandwidth of measuring photoacoustic (PA) pressure transients. In this work, we further present a systematic investigation on PA response characteristics of the recently developed SP-based ultrasonic detector, where the ensemble of surface plasmon polaritons (SPPs) at the metal-dielectric interface is approximated as an equivalent acoustic detector. Relying on the intrinsically ultrafast temporal response (∼140 fs) and highly localized evanescent field (optical penetration depth of ∼185 nm) of the SPPs, the SP sensing can respond ultrasounds with the gigahertz frequency band theoretically, which, however, is far higher than the bandwidth in practical PA detection. We reveal that, due to acoustic interference, the finite lateral probing dimension in the SP sensor imposes an ultimate constraint on the accessible ultrasonic cutoff frequency, representing good agreement with the experimental results by acquiring PA impulses from an optically absorbing graphene film using our SP sensor. The theoretical framework enables analyzing the SP response characteristics of ultrasonic/PA pressure transients, which, therefore, offers guidelines for configuring the SP sensor with adequate sensitivity and bandwidths to access various biomedical PA applications, including volumetric imaging and spectroscopic analysis.</description><subject>Applied physics</subject><subject>Bandwidths</subject><subject>Broadband</subject><subject>Detection</subject><subject>Frequencies</subject><subject>Graphene</subject><subject>Penetration depth</subject><subject>Polaritons</subject><subject>Sensitivity</subject><subject>Sensors</subject><issn>0003-6951</issn><issn>1077-3118</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LAzEQhoMoWKsH_8GCJ4Wt-djdbI9S_IKCl3oO2WRiV2qyZrKi_96UFj0InoaZed53mJeQc0ZnjDbiup5RSivO5AGZMCplKRhrD8kkT0XZzGt2TE4QX3NbcyEmxKzWECKk3uhNob0t4HOA2L-BT3mAabQ9YBF80cWgbbclhnVIQZswYlYVEXAIHqEIrsAxOm2gGDYa37IGwWPvX07JkdMbhLN9nZLnu9vV4qFcPt0_Lm6WpRFcprLtrOFdC7JhpmWt0E5r04KRAmzXAbOc8sbVrJKNqHgzz4tau467SnDrKIgpudj5DjG8j4BJvYYx-nxS8YoJKVnNRKYud5SJATGCU0P-V8cvxajaZqhqtc8ws1c7Fk2fdOqD_4E_QvwF1WDdf_Bf529pD4Gt</recordid><startdate>20200615</startdate><enddate>20200615</enddate><creator>Song, Wei</creator><creator>Xiao, Sijie</creator><creator>Min, Changjun</creator><creator>Fang, Hui</creator><creator>Yuan, Xiaocong</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-4764-9988</orcidid><orcidid>https://orcid.org/0000-0002-6021-5535</orcidid></search><sort><creationdate>20200615</creationdate><title>Theoretical and experimental studies on broadband photoacoustic response of surface plasmon sensing</title><author>Song, Wei ; Xiao, Sijie ; Min, Changjun ; Fang, Hui ; Yuan, Xiaocong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c327t-8bdc2b8e761c8183afaac8ec73edbbe1d2026f5147634269c735afb2f432df0e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Applied physics</topic><topic>Bandwidths</topic><topic>Broadband</topic><topic>Detection</topic><topic>Frequencies</topic><topic>Graphene</topic><topic>Penetration depth</topic><topic>Polaritons</topic><topic>Sensitivity</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Song, Wei</creatorcontrib><creatorcontrib>Xiao, Sijie</creatorcontrib><creatorcontrib>Min, Changjun</creatorcontrib><creatorcontrib>Fang, Hui</creatorcontrib><creatorcontrib>Yuan, Xiaocong</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Applied physics letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Song, Wei</au><au>Xiao, Sijie</au><au>Min, Changjun</au><au>Fang, Hui</au><au>Yuan, Xiaocong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Theoretical and experimental studies on broadband photoacoustic response of surface plasmon sensing</atitle><jtitle>Applied physics letters</jtitle><date>2020-06-15</date><risdate>2020</risdate><volume>116</volume><issue>24</issue><issn>0003-6951</issn><eissn>1077-3118</eissn><coden>APPLAB</coden><abstract>The surface plasmon (SP) sensing technique demonstrates high sensitivity and a broad bandwidth of measuring photoacoustic (PA) pressure transients. In this work, we further present a systematic investigation on PA response characteristics of the recently developed SP-based ultrasonic detector, where the ensemble of surface plasmon polaritons (SPPs) at the metal-dielectric interface is approximated as an equivalent acoustic detector. Relying on the intrinsically ultrafast temporal response (∼140 fs) and highly localized evanescent field (optical penetration depth of ∼185 nm) of the SPPs, the SP sensing can respond ultrasounds with the gigahertz frequency band theoretically, which, however, is far higher than the bandwidth in practical PA detection. We reveal that, due to acoustic interference, the finite lateral probing dimension in the SP sensor imposes an ultimate constraint on the accessible ultrasonic cutoff frequency, representing good agreement with the experimental results by acquiring PA impulses from an optically absorbing graphene film using our SP sensor. The theoretical framework enables analyzing the SP response characteristics of ultrasonic/PA pressure transients, which, therefore, offers guidelines for configuring the SP sensor with adequate sensitivity and bandwidths to access various biomedical PA applications, including volumetric imaging and spectroscopic analysis.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0004217</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0002-4764-9988</orcidid><orcidid>https://orcid.org/0000-0002-6021-5535</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-6951 |
ispartof | Applied physics letters, 2020-06, Vol.116 (24) |
issn | 0003-6951 1077-3118 |
language | eng |
recordid | cdi_scitation_primary_10_1063_5_0004217 |
source | AIP Journals Complete; Alma/SFX Local Collection |
subjects | Applied physics Bandwidths Broadband Detection Frequencies Graphene Penetration depth Polaritons Sensitivity Sensors |
title | Theoretical and experimental studies on broadband photoacoustic response of surface plasmon sensing |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T22%3A21%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Theoretical%20and%20experimental%20studies%20on%20broadband%20photoacoustic%20response%20of%20surface%20plasmon%20sensing&rft.jtitle=Applied%20physics%20letters&rft.au=Song,%20Wei&rft.date=2020-06-15&rft.volume=116&rft.issue=24&rft.issn=0003-6951&rft.eissn=1077-3118&rft.coden=APPLAB&rft_id=info:doi/10.1063/5.0004217&rft_dat=%3Cproquest_scita%3E2413771513%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2413771513&rft_id=info:pmid/&rfr_iscdi=true |