On the radiated EMI current extraction of dc transmission line based on corona current statistical measurements

Corona-originated discharge of DC transmission lines is the main reason for the radiated electromagnetic interference (EMI) field in the vicinity of transmission lines. A joint time-frequency analysis technique was proposed to extract the radiated EMI current (excitation current) of DC corona based...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:AIP advances 2018-05, Vol.8 (5), p.055001-055001-13
Hauptverfasser: Yi, Yong, Chen, Zhengying, Wang, Liming
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 055001-13
container_issue 5
container_start_page 055001
container_title AIP advances
container_volume 8
creator Yi, Yong
Chen, Zhengying
Wang, Liming
description Corona-originated discharge of DC transmission lines is the main reason for the radiated electromagnetic interference (EMI) field in the vicinity of transmission lines. A joint time-frequency analysis technique was proposed to extract the radiated EMI current (excitation current) of DC corona based on corona current statistical measurements. A reduced-scale experimental platform was setup to measure the statistical distributions of current waveform parameters of aluminum conductor steel reinforced. Based on the measured results, the peak value, root-mean-square value and average value with 9 kHz and 200 Hz band-with of 0.5 MHz radiated EMI current were calculated by the technique proposed and validated with conventional excitation function method. Radio interference (RI) was calculated based on the radiated EMI current and a wire-to-plate platform was built for the validity of the RI computation results. The reason for the certain deviation between the computations and measurements was detailed analyzed.
doi_str_mv 10.1063/1.5018328
format Article
fullrecord <record><control><sourceid>scitation_doaj_</sourceid><recordid>TN_cdi_scitation_primary_10_1063_1_5018328</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_f6d0526026cc42fda7e06cee77655c4d</doaj_id><sourcerecordid>adv</sourcerecordid><originalsourceid>FETCH-LOGICAL-c360t-15c161db8a40dccf0fccd10c318f20bbf9e3b9af2880abe09e14cfcb43107adf3</originalsourceid><addsrcrecordid>eNqdUMFOAjEQ3RhNJMjBP-hVE3Da3S3L0RBUEgwXPTez01ZLYEvaYvTvLULQs3OZeS9vXmZeUVxzGHGQ5R0f1cCbUjRnRU_wuhmWQsjzP_NlMYhxBbmqCYem6hV-2bH0blhA7TAZzWbPc0a7EEyXmPlMASk53zFvmSaWYRc3LsY9tXadYS3GvJQR-eA7PK3GhMnF5AjXbGMw7oLZZD5eFRcW19EMjr1fvD7MXqZPw8XycT69XwyplJCGvCYuuW4brEATWbBEmgOVvLEC2tZOTNlO0IqmAWwNTAyvyFJblRzGqG3ZL-YHX-1xpbbBbTB8KY9O_RA-vCkM-by1UVZqqIUEIYkqYTWODUgyZjyWdU2Vzl43By8KPsZg7MmPg9oHr7g6Bp-1twdtJLePwHf_E3_48CtU2_zRN7ZWk_0</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>On the radiated EMI current extraction of dc transmission line based on corona current statistical measurements</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Yi, Yong ; Chen, Zhengying ; Wang, Liming</creator><creatorcontrib>Yi, Yong ; Chen, Zhengying ; Wang, Liming</creatorcontrib><description>Corona-originated discharge of DC transmission lines is the main reason for the radiated electromagnetic interference (EMI) field in the vicinity of transmission lines. A joint time-frequency analysis technique was proposed to extract the radiated EMI current (excitation current) of DC corona based on corona current statistical measurements. A reduced-scale experimental platform was setup to measure the statistical distributions of current waveform parameters of aluminum conductor steel reinforced. Based on the measured results, the peak value, root-mean-square value and average value with 9 kHz and 200 Hz band-with of 0.5 MHz radiated EMI current were calculated by the technique proposed and validated with conventional excitation function method. Radio interference (RI) was calculated based on the radiated EMI current and a wire-to-plate platform was built for the validity of the RI computation results. The reason for the certain deviation between the computations and measurements was detailed analyzed.</description><identifier>ISSN: 2158-3226</identifier><identifier>EISSN: 2158-3226</identifier><identifier>DOI: 10.1063/1.5018328</identifier><identifier>CODEN: AAIDBI</identifier><language>eng</language><publisher>AIP Publishing LLC</publisher><ispartof>AIP advances, 2018-05, Vol.8 (5), p.055001-055001-13</ispartof><rights>Author(s)</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c360t-15c161db8a40dccf0fccd10c318f20bbf9e3b9af2880abe09e14cfcb43107adf3</cites><orcidid>0000-0002-4290-5292</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,2096,27901,27902</link.rule.ids></links><search><creatorcontrib>Yi, Yong</creatorcontrib><creatorcontrib>Chen, Zhengying</creatorcontrib><creatorcontrib>Wang, Liming</creatorcontrib><title>On the radiated EMI current extraction of dc transmission line based on corona current statistical measurements</title><title>AIP advances</title><description>Corona-originated discharge of DC transmission lines is the main reason for the radiated electromagnetic interference (EMI) field in the vicinity of transmission lines. A joint time-frequency analysis technique was proposed to extract the radiated EMI current (excitation current) of DC corona based on corona current statistical measurements. A reduced-scale experimental platform was setup to measure the statistical distributions of current waveform parameters of aluminum conductor steel reinforced. Based on the measured results, the peak value, root-mean-square value and average value with 9 kHz and 200 Hz band-with of 0.5 MHz radiated EMI current were calculated by the technique proposed and validated with conventional excitation function method. Radio interference (RI) was calculated based on the radiated EMI current and a wire-to-plate platform was built for the validity of the RI computation results. The reason for the certain deviation between the computations and measurements was detailed analyzed.</description><issn>2158-3226</issn><issn>2158-3226</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNqdUMFOAjEQ3RhNJMjBP-hVE3Da3S3L0RBUEgwXPTez01ZLYEvaYvTvLULQs3OZeS9vXmZeUVxzGHGQ5R0f1cCbUjRnRU_wuhmWQsjzP_NlMYhxBbmqCYem6hV-2bH0blhA7TAZzWbPc0a7EEyXmPlMASk53zFvmSaWYRc3LsY9tXadYS3GvJQR-eA7PK3GhMnF5AjXbGMw7oLZZD5eFRcW19EMjr1fvD7MXqZPw8XycT69XwyplJCGvCYuuW4brEATWbBEmgOVvLEC2tZOTNlO0IqmAWwNTAyvyFJblRzGqG3ZL-YHX-1xpbbBbTB8KY9O_RA-vCkM-by1UVZqqIUEIYkqYTWODUgyZjyWdU2Vzl43By8KPsZg7MmPg9oHr7g6Bp-1twdtJLePwHf_E3_48CtU2_zRN7ZWk_0</recordid><startdate>201805</startdate><enddate>201805</enddate><creator>Yi, Yong</creator><creator>Chen, Zhengying</creator><creator>Wang, Liming</creator><general>AIP Publishing LLC</general><scope>AJDQP</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-4290-5292</orcidid></search><sort><creationdate>201805</creationdate><title>On the radiated EMI current extraction of dc transmission line based on corona current statistical measurements</title><author>Yi, Yong ; Chen, Zhengying ; Wang, Liming</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c360t-15c161db8a40dccf0fccd10c318f20bbf9e3b9af2880abe09e14cfcb43107adf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yi, Yong</creatorcontrib><creatorcontrib>Chen, Zhengying</creatorcontrib><creatorcontrib>Wang, Liming</creatorcontrib><collection>AIP Open Access Journals</collection><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>AIP advances</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yi, Yong</au><au>Chen, Zhengying</au><au>Wang, Liming</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On the radiated EMI current extraction of dc transmission line based on corona current statistical measurements</atitle><jtitle>AIP advances</jtitle><date>2018-05</date><risdate>2018</risdate><volume>8</volume><issue>5</issue><spage>055001</spage><epage>055001-13</epage><pages>055001-055001-13</pages><issn>2158-3226</issn><eissn>2158-3226</eissn><coden>AAIDBI</coden><abstract>Corona-originated discharge of DC transmission lines is the main reason for the radiated electromagnetic interference (EMI) field in the vicinity of transmission lines. A joint time-frequency analysis technique was proposed to extract the radiated EMI current (excitation current) of DC corona based on corona current statistical measurements. A reduced-scale experimental platform was setup to measure the statistical distributions of current waveform parameters of aluminum conductor steel reinforced. Based on the measured results, the peak value, root-mean-square value and average value with 9 kHz and 200 Hz band-with of 0.5 MHz radiated EMI current were calculated by the technique proposed and validated with conventional excitation function method. Radio interference (RI) was calculated based on the radiated EMI current and a wire-to-plate platform was built for the validity of the RI computation results. The reason for the certain deviation between the computations and measurements was detailed analyzed.</abstract><pub>AIP Publishing LLC</pub><doi>10.1063/1.5018328</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0002-4290-5292</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2158-3226
ispartof AIP advances, 2018-05, Vol.8 (5), p.055001-055001-13
issn 2158-3226
2158-3226
language eng
recordid cdi_scitation_primary_10_1063_1_5018328
source DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry
title On the radiated EMI current extraction of dc transmission line based on corona current statistical measurements
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T21%3A01%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20the%20radiated%20EMI%20current%20extraction%20of%20dc%20transmission%20line%20based%20on%20corona%20current%20statistical%20measurements&rft.jtitle=AIP%20advances&rft.au=Yi,%20Yong&rft.date=2018-05&rft.volume=8&rft.issue=5&rft.spage=055001&rft.epage=055001-13&rft.pages=055001-055001-13&rft.issn=2158-3226&rft.eissn=2158-3226&rft.coden=AAIDBI&rft_id=info:doi/10.1063/1.5018328&rft_dat=%3Cscitation_doaj_%3Eadv%3C/scitation_doaj_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_doaj_id=oai_doaj_org_article_f6d0526026cc42fda7e06cee77655c4d&rfr_iscdi=true