THE WENNER POTENTIOMETER
A two‐range, five‐dial potentiometer is described which incorporates a decade construction suggested by Wenner. The upper range is 1.9111 volts in steps of 10 microvolts and the lower range is one tenth of this. The effect of contact resistance, thermal emf's and of errors in adjustment is cons...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 1932-03, Vol.3 (3), p.109-120 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 120 |
---|---|
container_issue | 3 |
container_start_page | 109 |
container_title | Review of scientific instruments |
container_volume | 3 |
creator | Behr, Leo |
description | A two‐range, five‐dial potentiometer is described which incorporates a decade construction suggested by Wenner. The upper range is 1.9111 volts in steps of 10 microvolts and the lower range is one tenth of this. The effect of contact resistance, thermal emf's and of errors in adjustment is considered in detail.
The limit of error for the instrument is 0.005 percent or 2 microvolts for the high range and 0.01 percent or 0.2 microvolt for the low range. |
doi_str_mv | 10.1063/1.1748912 |
format | Article |
fullrecord | <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_scitation_primary_10_1063_1_1748912</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c299t-150ef5abfa1b0923a81aa65d5561fa41b6a52c5390c408c1b726495105df07d3</originalsourceid><addsrcrecordid>eNqdj8FLwzAYxYMoWKcHbx53Vcj2fUmTNkcZ0Q22VkbAY0jTBipqR1IE_3srG3j3Xd7h_XjwI-QWYYEg-RIXWOSlQnZGMoRS0UIyfk4yAJ5TOU2X5CqlN5giEDNyZ9Z6_qqrSu_nL7XRldnUO230_ppcBPeeuptTz4h50ma1ptv6ebN63FLPlBopCuiCcE1w2IBi3JXonBStEBKDy7GRTjAvuAKfQ-mxKZjMlUAQbYCi5TNyf7z1cUgpdsEeYv_h4rdFsL9GFu3JaGIfjmzy_ejGfvj8H_w1xD_QHtrAfwBSzVU-</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>THE WENNER POTENTIOMETER</title><source>AIP Digital Archive</source><creator>Behr, Leo</creator><creatorcontrib>Behr, Leo</creatorcontrib><description>A two‐range, five‐dial potentiometer is described which incorporates a decade construction suggested by Wenner. The upper range is 1.9111 volts in steps of 10 microvolts and the lower range is one tenth of this. The effect of contact resistance, thermal emf's and of errors in adjustment is considered in detail.
The limit of error for the instrument is 0.005 percent or 2 microvolts for the high range and 0.01 percent or 0.2 microvolt for the low range.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1748912</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><ispartof>Review of scientific instruments, 1932-03, Vol.3 (3), p.109-120</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c299t-150ef5abfa1b0923a81aa65d5561fa41b6a52c5390c408c1b726495105df07d3</citedby><cites>FETCH-LOGICAL-c299t-150ef5abfa1b0923a81aa65d5561fa41b6a52c5390c408c1b726495105df07d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1748912$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,1559,27924,27925,76390</link.rule.ids></links><search><creatorcontrib>Behr, Leo</creatorcontrib><title>THE WENNER POTENTIOMETER</title><title>Review of scientific instruments</title><description>A two‐range, five‐dial potentiometer is described which incorporates a decade construction suggested by Wenner. The upper range is 1.9111 volts in steps of 10 microvolts and the lower range is one tenth of this. The effect of contact resistance, thermal emf's and of errors in adjustment is considered in detail.
The limit of error for the instrument is 0.005 percent or 2 microvolts for the high range and 0.01 percent or 0.2 microvolt for the low range.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1932</creationdate><recordtype>article</recordtype><recordid>eNqdj8FLwzAYxYMoWKcHbx53Vcj2fUmTNkcZ0Q22VkbAY0jTBipqR1IE_3srG3j3Xd7h_XjwI-QWYYEg-RIXWOSlQnZGMoRS0UIyfk4yAJ5TOU2X5CqlN5giEDNyZ9Z6_qqrSu_nL7XRldnUO230_ppcBPeeuptTz4h50ma1ptv6ebN63FLPlBopCuiCcE1w2IBi3JXonBStEBKDy7GRTjAvuAKfQ-mxKZjMlUAQbYCi5TNyf7z1cUgpdsEeYv_h4rdFsL9GFu3JaGIfjmzy_ejGfvj8H_w1xD_QHtrAfwBSzVU-</recordid><startdate>19320301</startdate><enddate>19320301</enddate><creator>Behr, Leo</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19320301</creationdate><title>THE WENNER POTENTIOMETER</title><author>Behr, Leo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c299t-150ef5abfa1b0923a81aa65d5561fa41b6a52c5390c408c1b726495105df07d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1932</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Behr, Leo</creatorcontrib><collection>CrossRef</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Behr, Leo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>THE WENNER POTENTIOMETER</atitle><jtitle>Review of scientific instruments</jtitle><date>1932-03-01</date><risdate>1932</risdate><volume>3</volume><issue>3</issue><spage>109</spage><epage>120</epage><pages>109-120</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>A two‐range, five‐dial potentiometer is described which incorporates a decade construction suggested by Wenner. The upper range is 1.9111 volts in steps of 10 microvolts and the lower range is one tenth of this. The effect of contact resistance, thermal emf's and of errors in adjustment is considered in detail.
The limit of error for the instrument is 0.005 percent or 2 microvolts for the high range and 0.01 percent or 0.2 microvolt for the low range.</abstract><doi>10.1063/1.1748912</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 1932-03, Vol.3 (3), p.109-120 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_scitation_primary_10_1063_1_1748912 |
source | AIP Digital Archive |
title | THE WENNER POTENTIOMETER |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T03%3A47%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=THE%20WENNER%20POTENTIOMETER&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Behr,%20Leo&rft.date=1932-03-01&rft.volume=3&rft.issue=3&rft.spage=109&rft.epage=120&rft.pages=109-120&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1748912&rft_dat=%3Cscitation_cross%3Ersi%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |