High Pressure Ionization Chamber Counters and Their Use

Certain new developments in ionization chamber technique are described. Ionization chamber counters have been designed to operate with fillings of H2, D2, or CH4 to pressures of 35 atoms. with simple filling techniques. The design, characteristics, and uses of these counters are described.

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Rev. Sci. Instruments 1950-08, Vol.21 (8), p.699-705
Hauptverfasser: Wilson, R., Beghian, L., Collie, C. H., Halban, H., Bishop, G. R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 705
container_issue 8
container_start_page 699
container_title Rev. Sci. Instruments
container_volume 21
creator Wilson, R.
Beghian, L.
Collie, C. H.
Halban, H.
Bishop, G. R.
description Certain new developments in ionization chamber technique are described. Ionization chamber counters have been designed to operate with fillings of H2, D2, or CH4 to pressures of 35 atoms. with simple filling techniques. The design, characteristics, and uses of these counters are described.
doi_str_mv 10.1063/1.1745694
format Article
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_scitation_primary_10_1063_1_1745694</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>74702038</sourcerecordid><originalsourceid>FETCH-LOGICAL-c380t-f3d04ea4627712a457e1b30f500ef1748a4d4565c98f129270921b3ec6ebb1663</originalsourceid><addsrcrecordid>eNp90M1Kw0AUBeBBFFurC19AggtBIXX-MpMsJagtFHTRrofJ5MZEmkydSQR9elMT6Erv5m4-DoeD0CXBc4IFuydzInkkEn6EpgTHSSgFZcdoijHjoZA8nqAz799xfxEhp2hCuIwJ53SK5KJ6K4NXB953DoKlbapv3Va2CdJS1xm4ILVd04LzgW7yYF1C5YKNh3N0Uuith4vxz9Dm6XGdLsLVy_MyfViFhsW4DQuWYw6aCyoloZpHEkjGcBFhDEVfOtY875tHJokLQhMqcUJ7AEZAlhEh2AxdD7nWt5XypmrBlMY2DZhWcc4EpUmPbga0c_ajA9-quvIGtlvdgO28klxiilncw9sBGme9d1Conatq7b4UwWo_pSJqnLK3V2Nol9WQH-S4XQ_uBrBv9bvZv2l_4k_rDlDt8oL9AOR8hy4</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>74702038</pqid></control><display><type>article</type><title>High Pressure Ionization Chamber Counters and Their Use</title><source>MEDLINE</source><source>AIP Digital Archive</source><creator>Wilson, R. ; Beghian, L. ; Collie, C. H. ; Halban, H. ; Bishop, G. R.</creator><creatorcontrib>Wilson, R. ; Beghian, L. ; Collie, C. H. ; Halban, H. ; Bishop, G. R. ; Originating Research Org. not identified</creatorcontrib><description>Certain new developments in ionization chamber technique are described. Ionization chamber counters have been designed to operate with fillings of H2, D2, or CH4 to pressures of 35 atoms. with simple filling techniques. The design, characteristics, and uses of these counters are described.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1745694</identifier><identifier>PMID: 14781442</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States</publisher><subject>COUNTERS ; DEUTERIUM ; Equipment and Supplies ; HYDROGEN ; IONIZATION CHAMBERS ; METHANE ; Old Medline ; OPERATION ; PHYSICS ; PLANNING ; PRESSURE ; USES</subject><ispartof>Rev. Sci. Instruments, 1950-08, Vol.21 (8), p.699-705</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c380t-f3d04ea4627712a457e1b30f500ef1748a4d4565c98f129270921b3ec6ebb1663</citedby><cites>FETCH-LOGICAL-c380t-f3d04ea4627712a457e1b30f500ef1748a4d4565c98f129270921b3ec6ebb1663</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1745694$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,776,780,881,1553,27901,27902,76133</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/14781442$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/biblio/4436229$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Wilson, R.</creatorcontrib><creatorcontrib>Beghian, L.</creatorcontrib><creatorcontrib>Collie, C. H.</creatorcontrib><creatorcontrib>Halban, H.</creatorcontrib><creatorcontrib>Bishop, G. R.</creatorcontrib><creatorcontrib>Originating Research Org. not identified</creatorcontrib><title>High Pressure Ionization Chamber Counters and Their Use</title><title>Rev. Sci. Instruments</title><addtitle>Rev Sci Instrum</addtitle><description>Certain new developments in ionization chamber technique are described. Ionization chamber counters have been designed to operate with fillings of H2, D2, or CH4 to pressures of 35 atoms. with simple filling techniques. The design, characteristics, and uses of these counters are described.</description><subject>COUNTERS</subject><subject>DEUTERIUM</subject><subject>Equipment and Supplies</subject><subject>HYDROGEN</subject><subject>IONIZATION CHAMBERS</subject><subject>METHANE</subject><subject>Old Medline</subject><subject>OPERATION</subject><subject>PHYSICS</subject><subject>PLANNING</subject><subject>PRESSURE</subject><subject>USES</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1950</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp90M1Kw0AUBeBBFFurC19AggtBIXX-MpMsJagtFHTRrofJ5MZEmkydSQR9elMT6Erv5m4-DoeD0CXBc4IFuydzInkkEn6EpgTHSSgFZcdoijHjoZA8nqAz799xfxEhp2hCuIwJ53SK5KJ6K4NXB953DoKlbapv3Va2CdJS1xm4ILVd04LzgW7yYF1C5YKNh3N0Uuith4vxz9Dm6XGdLsLVy_MyfViFhsW4DQuWYw6aCyoloZpHEkjGcBFhDEVfOtY875tHJokLQhMqcUJ7AEZAlhEh2AxdD7nWt5XypmrBlMY2DZhWcc4EpUmPbga0c_ajA9-quvIGtlvdgO28klxiilncw9sBGme9d1Conatq7b4UwWo_pSJqnLK3V2Nol9WQH-S4XQ_uBrBv9bvZv2l_4k_rDlDt8oL9AOR8hy4</recordid><startdate>195008</startdate><enddate>195008</enddate><creator>Wilson, R.</creator><creator>Beghian, L.</creator><creator>Collie, C. H.</creator><creator>Halban, H.</creator><creator>Bishop, G. R.</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>OTOTI</scope></search><sort><creationdate>195008</creationdate><title>High Pressure Ionization Chamber Counters and Their Use</title><author>Wilson, R. ; Beghian, L. ; Collie, C. H. ; Halban, H. ; Bishop, G. R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c380t-f3d04ea4627712a457e1b30f500ef1748a4d4565c98f129270921b3ec6ebb1663</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1950</creationdate><topic>COUNTERS</topic><topic>DEUTERIUM</topic><topic>Equipment and Supplies</topic><topic>HYDROGEN</topic><topic>IONIZATION CHAMBERS</topic><topic>METHANE</topic><topic>Old Medline</topic><topic>OPERATION</topic><topic>PHYSICS</topic><topic>PLANNING</topic><topic>PRESSURE</topic><topic>USES</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wilson, R.</creatorcontrib><creatorcontrib>Beghian, L.</creatorcontrib><creatorcontrib>Collie, C. H.</creatorcontrib><creatorcontrib>Halban, H.</creatorcontrib><creatorcontrib>Bishop, G. R.</creatorcontrib><creatorcontrib>Originating Research Org. not identified</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>OSTI.GOV</collection><jtitle>Rev. Sci. Instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wilson, R.</au><au>Beghian, L.</au><au>Collie, C. H.</au><au>Halban, H.</au><au>Bishop, G. R.</au><aucorp>Originating Research Org. not identified</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High Pressure Ionization Chamber Counters and Their Use</atitle><jtitle>Rev. Sci. Instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>1950-08</date><risdate>1950</risdate><volume>21</volume><issue>8</issue><spage>699</spage><epage>705</epage><pages>699-705</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Certain new developments in ionization chamber technique are described. Ionization chamber counters have been designed to operate with fillings of H2, D2, or CH4 to pressures of 35 atoms. with simple filling techniques. The design, characteristics, and uses of these counters are described.</abstract><cop>United States</cop><pmid>14781442</pmid><doi>10.1063/1.1745694</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Rev. Sci. Instruments, 1950-08, Vol.21 (8), p.699-705
issn 0034-6748
1089-7623
language eng
recordid cdi_scitation_primary_10_1063_1_1745694
source MEDLINE; AIP Digital Archive
subjects COUNTERS
DEUTERIUM
Equipment and Supplies
HYDROGEN
IONIZATION CHAMBERS
METHANE
Old Medline
OPERATION
PHYSICS
PLANNING
PRESSURE
USES
title High Pressure Ionization Chamber Counters and Their Use
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T22%3A20%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20Pressure%20Ionization%20Chamber%20Counters%20and%20Their%20Use&rft.jtitle=Rev.%20Sci.%20Instruments&rft.au=Wilson,%20R.&rft.aucorp=Originating%20Research%20Org.%20not%20identified&rft.date=1950-08&rft.volume=21&rft.issue=8&rft.spage=699&rft.epage=705&rft.pages=699-705&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1745694&rft_dat=%3Cproquest_scita%3E74702038%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=74702038&rft_id=info:pmid/14781442&rfr_iscdi=true