Beam position monitor for the SPring‐8 synchrotron
Beam position monitors (BPMs) for the SPring‐8 synchrotron have already been designed and manufactured. Each BPM pickup has four button‐type electrodes, and the output signals from the electrodes are switched by fast PIN‐diode and are measured by signal detection systems. Eighty BPMs and four detect...
Gespeichert in:
Veröffentlicht in: | Review of Scientific Instruments 1996-09, Vol.67 (9), p.3367-3367 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 3367 |
---|---|
container_issue | 9 |
container_start_page | 3367 |
container_title | Review of Scientific Instruments |
container_volume | 67 |
creator | Aoki, T. Yonehara, H. Suzuki, H. Tani, N. Abe, H. Fukami, K. Hayashi, S. Ueyama, Y. Kaneta, T. Okanishi, K. Ohzuchi, S. Miyaoka, T. Sato, K. Toyoda, E. Ito, H. Yokomizo, Hideaki |
description | Beam position monitors (BPMs) for the SPring‐8 synchrotron have already been designed and manufactured. Each BPM pickup has four button‐type electrodes, and the output signals from the electrodes are switched by fast PIN‐diode and are measured by signal detection systems. Eighty BPMs and four detection systems are placed around the synchrotron. Calibration of beam position of the 80 BPMs was finished successfully. In this paper, we present the structure of the BPM pickup, the electronics of the signal detection system, and the calibration system. |
doi_str_mv | 10.1063/1.1147475 |
format | Article |
fullrecord | <record><control><sourceid>scitation_osti_</sourceid><recordid>TN_cdi_scitation_primary_10_1063_1_1147475</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c200t-c1cacda03b0e286269a452aabaa997675cc3fb0e4a4dfb1654ecff2935cf48eb3</originalsourceid><addsrcrecordid>eNqd0M1KAzEQB_AgCtbqwTdYjwpbM5uP3Ry1-AUFBfUcstPERmxSkiD05iP4jD6JW1rw7sAwh_kxMH9CToFOgEp2CRMA3vJW7JER0E7VrWzYPhlRyngtW94dkqOc3-lQAmBE-LU1y2oVsy8-hmoZgy8xVW7osrDV81Py4e3n67ur8jrgIsWSYjgmB858ZHuym2PyenvzMr2vZ493D9OrWY0NpaVGQINzQ1lPbdPJRirDRWNMb4xSrWwFInPDjhs-dz1IwS061ygm0PHO9mxMzrZ3Yy5eZ_TF4gJjCBaLZp0SCgZzvjWYYs7JOr1KfmnSWgPVm0g06F0kg73Y2s0ps3n4f_gzpj-oV3PHfgFsunBZ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Beam position monitor for the SPring‐8 synchrotron</title><source>AIP Digital Archive</source><creator>Aoki, T. ; Yonehara, H. ; Suzuki, H. ; Tani, N. ; Abe, H. ; Fukami, K. ; Hayashi, S. ; Ueyama, Y. ; Kaneta, T. ; Okanishi, K. ; Ohzuchi, S. ; Miyaoka, T. ; Sato, K. ; Toyoda, E. ; Ito, H. ; Yokomizo, Hideaki</creator><creatorcontrib>Aoki, T. ; Yonehara, H. ; Suzuki, H. ; Tani, N. ; Abe, H. ; Fukami, K. ; Hayashi, S. ; Ueyama, Y. ; Kaneta, T. ; Okanishi, K. ; Ohzuchi, S. ; Miyaoka, T. ; Sato, K. ; Toyoda, E. ; Ito, H. ; Yokomizo, Hideaki</creatorcontrib><description>Beam position monitors (BPMs) for the SPring‐8 synchrotron have already been designed and manufactured. Each BPM pickup has four button‐type electrodes, and the output signals from the electrodes are switched by fast PIN‐diode and are measured by signal detection systems. Eighty BPMs and four detection systems are placed around the synchrotron. Calibration of beam position of the 80 BPMs was finished successfully. In this paper, we present the structure of the BPM pickup, the electronics of the signal detection system, and the calibration system.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1147475</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States</publisher><subject>BEAM MONITORS ; BEAM POSITION ; CALIBRATION ; DESIGN ; ELECTRONIC CIRCUITS ; INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS ; SPECIFICATIONS ; SPRING-8 STORAGE RING ; SYNCHROTRON RADIATION SOURCES ; X-RAY EQUIPMENT</subject><ispartof>Review of Scientific Instruments, 1996-09, Vol.67 (9), p.3367-3367</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1147475$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,885,1559,23930,23931,25140,27924,27925,76390</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/389591$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Aoki, T.</creatorcontrib><creatorcontrib>Yonehara, H.</creatorcontrib><creatorcontrib>Suzuki, H.</creatorcontrib><creatorcontrib>Tani, N.</creatorcontrib><creatorcontrib>Abe, H.</creatorcontrib><creatorcontrib>Fukami, K.</creatorcontrib><creatorcontrib>Hayashi, S.</creatorcontrib><creatorcontrib>Ueyama, Y.</creatorcontrib><creatorcontrib>Kaneta, T.</creatorcontrib><creatorcontrib>Okanishi, K.</creatorcontrib><creatorcontrib>Ohzuchi, S.</creatorcontrib><creatorcontrib>Miyaoka, T.</creatorcontrib><creatorcontrib>Sato, K.</creatorcontrib><creatorcontrib>Toyoda, E.</creatorcontrib><creatorcontrib>Ito, H.</creatorcontrib><creatorcontrib>Yokomizo, Hideaki</creatorcontrib><title>Beam position monitor for the SPring‐8 synchrotron</title><title>Review of Scientific Instruments</title><description>Beam position monitors (BPMs) for the SPring‐8 synchrotron have already been designed and manufactured. Each BPM pickup has four button‐type electrodes, and the output signals from the electrodes are switched by fast PIN‐diode and are measured by signal detection systems. Eighty BPMs and four detection systems are placed around the synchrotron. Calibration of beam position of the 80 BPMs was finished successfully. In this paper, we present the structure of the BPM pickup, the electronics of the signal detection system, and the calibration system.</description><subject>BEAM MONITORS</subject><subject>BEAM POSITION</subject><subject>CALIBRATION</subject><subject>DESIGN</subject><subject>ELECTRONIC CIRCUITS</subject><subject>INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS</subject><subject>SPECIFICATIONS</subject><subject>SPRING-8 STORAGE RING</subject><subject>SYNCHROTRON RADIATION SOURCES</subject><subject>X-RAY EQUIPMENT</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNqd0M1KAzEQB_AgCtbqwTdYjwpbM5uP3Ry1-AUFBfUcstPERmxSkiD05iP4jD6JW1rw7sAwh_kxMH9CToFOgEp2CRMA3vJW7JER0E7VrWzYPhlRyngtW94dkqOc3-lQAmBE-LU1y2oVsy8-hmoZgy8xVW7osrDV81Py4e3n67ur8jrgIsWSYjgmB858ZHuym2PyenvzMr2vZ493D9OrWY0NpaVGQINzQ1lPbdPJRirDRWNMb4xSrWwFInPDjhs-dz1IwS061ygm0PHO9mxMzrZ3Yy5eZ_TF4gJjCBaLZp0SCgZzvjWYYs7JOr1KfmnSWgPVm0g06F0kg73Y2s0ps3n4f_gzpj-oV3PHfgFsunBZ</recordid><startdate>199609</startdate><enddate>199609</enddate><creator>Aoki, T.</creator><creator>Yonehara, H.</creator><creator>Suzuki, H.</creator><creator>Tani, N.</creator><creator>Abe, H.</creator><creator>Fukami, K.</creator><creator>Hayashi, S.</creator><creator>Ueyama, Y.</creator><creator>Kaneta, T.</creator><creator>Okanishi, K.</creator><creator>Ohzuchi, S.</creator><creator>Miyaoka, T.</creator><creator>Sato, K.</creator><creator>Toyoda, E.</creator><creator>Ito, H.</creator><creator>Yokomizo, Hideaki</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>199609</creationdate><title>Beam position monitor for the SPring‐8 synchrotron</title><author>Aoki, T. ; Yonehara, H. ; Suzuki, H. ; Tani, N. ; Abe, H. ; Fukami, K. ; Hayashi, S. ; Ueyama, Y. ; Kaneta, T. ; Okanishi, K. ; Ohzuchi, S. ; Miyaoka, T. ; Sato, K. ; Toyoda, E. ; Ito, H. ; Yokomizo, Hideaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c200t-c1cacda03b0e286269a452aabaa997675cc3fb0e4a4dfb1654ecff2935cf48eb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>BEAM MONITORS</topic><topic>BEAM POSITION</topic><topic>CALIBRATION</topic><topic>DESIGN</topic><topic>ELECTRONIC CIRCUITS</topic><topic>INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS</topic><topic>SPECIFICATIONS</topic><topic>SPRING-8 STORAGE RING</topic><topic>SYNCHROTRON RADIATION SOURCES</topic><topic>X-RAY EQUIPMENT</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aoki, T.</creatorcontrib><creatorcontrib>Yonehara, H.</creatorcontrib><creatorcontrib>Suzuki, H.</creatorcontrib><creatorcontrib>Tani, N.</creatorcontrib><creatorcontrib>Abe, H.</creatorcontrib><creatorcontrib>Fukami, K.</creatorcontrib><creatorcontrib>Hayashi, S.</creatorcontrib><creatorcontrib>Ueyama, Y.</creatorcontrib><creatorcontrib>Kaneta, T.</creatorcontrib><creatorcontrib>Okanishi, K.</creatorcontrib><creatorcontrib>Ohzuchi, S.</creatorcontrib><creatorcontrib>Miyaoka, T.</creatorcontrib><creatorcontrib>Sato, K.</creatorcontrib><creatorcontrib>Toyoda, E.</creatorcontrib><creatorcontrib>Ito, H.</creatorcontrib><creatorcontrib>Yokomizo, Hideaki</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Review of Scientific Instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aoki, T.</au><au>Yonehara, H.</au><au>Suzuki, H.</au><au>Tani, N.</au><au>Abe, H.</au><au>Fukami, K.</au><au>Hayashi, S.</au><au>Ueyama, Y.</au><au>Kaneta, T.</au><au>Okanishi, K.</au><au>Ohzuchi, S.</au><au>Miyaoka, T.</au><au>Sato, K.</au><au>Toyoda, E.</au><au>Ito, H.</au><au>Yokomizo, Hideaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Beam position monitor for the SPring‐8 synchrotron</atitle><jtitle>Review of Scientific Instruments</jtitle><date>1996-09</date><risdate>1996</risdate><volume>67</volume><issue>9</issue><spage>3367</spage><epage>3367</epage><pages>3367-3367</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Beam position monitors (BPMs) for the SPring‐8 synchrotron have already been designed and manufactured. Each BPM pickup has four button‐type electrodes, and the output signals from the electrodes are switched by fast PIN‐diode and are measured by signal detection systems. Eighty BPMs and four detection systems are placed around the synchrotron. Calibration of beam position of the 80 BPMs was finished successfully. In this paper, we present the structure of the BPM pickup, the electronics of the signal detection system, and the calibration system.</abstract><cop>United States</cop><doi>10.1063/1.1147475</doi><tpages>1</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of Scientific Instruments, 1996-09, Vol.67 (9), p.3367-3367 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_scitation_primary_10_1063_1_1147475 |
source | AIP Digital Archive |
subjects | BEAM MONITORS BEAM POSITION CALIBRATION DESIGN ELECTRONIC CIRCUITS INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS SPECIFICATIONS SPRING-8 STORAGE RING SYNCHROTRON RADIATION SOURCES X-RAY EQUIPMENT |
title | Beam position monitor for the SPring‐8 synchrotron |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T16%3A07%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Beam%20position%20monitor%20for%20the%20SPring%E2%80%908%20synchrotron&rft.jtitle=Review%20of%20Scientific%20Instruments&rft.au=Aoki,%20T.&rft.date=1996-09&rft.volume=67&rft.issue=9&rft.spage=3367&rft.epage=3367&rft.pages=3367-3367&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1147475&rft_dat=%3Cscitation_osti_%3Ersi%3C/scitation_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |