Assessment of the efficiency of SimPlate™ total plate count color indicator (TPC CI) to quantify mesophilic aerobic microorganisms in pasteurized milk

The SimPlate(TM) TPC CI system is a rapid method to count mesophilic aerobic microorganisms (MAM) in foods, based on the use of resazurine to indicate bacterial growth. Its efficiency in pasteurized milk was evaluated using 142 pasteurized milk samples (38 type A, 43 type B and 61 type C) collected...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Brazilian journal of microbiology 2002-01, Vol.33 (1), p.44-48
Hauptverfasser: Nero, Luís Augusto, Beloti, Vanerli, Barros, Márcia de Aguiar Ferreira, Santana, Elsa Helena Walter de, Pereira, Mykel Steffani, Gusmão, Viviane Vieira, Moraes, Luciane Bilia de
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 48
container_issue 1
container_start_page 44
container_title Brazilian journal of microbiology
container_volume 33
creator Nero, Luís Augusto
Beloti, Vanerli
Barros, Márcia de Aguiar Ferreira
Santana, Elsa Helena Walter de
Pereira, Mykel Steffani
Gusmão, Viviane Vieira
Moraes, Luciane Bilia de
description The SimPlate(TM) TPC CI system is a rapid method to count mesophilic aerobic microorganisms (MAM) in foods, based on the use of resazurine to indicate bacterial growth. Its efficiency in pasteurized milk was evaluated using 142 pasteurized milk samples (38 type A, 43 type B and 61 type C) collected in Londrina, PR. The standard plating method, using Plate Count Agar (PCA) was used for comparison. The plates of both systems were incubated at 35ºC and read after 24h and 48h. The occurrence of false-positive and false-negative wells and the predominant microorganisms in them were also evaluated. The results were compared by simple correlation and mean variance analyses. The correlation (r) and mean variance values were 0.6811 and 0.7583 for the results obtained after 24h, respectively, and 0.9126 and 0.0842 for the results obtained after 48h, respectively. These results indicate that the performance of the system increases when the plates are incubated for 48h. When the three types of milk were evaluated separately, these values were 0.9285 and 0.0817 for type A milk, 0.9231 and 0.0466 for type B milk and 0.7209 and 0.1082 for type C milk. These results indicate that the better the quality of the milk the better the performance of SimPlate(TM) TPC CI. False-negative wells, found more frequently in samples with high MAM counts, were caused by Gram positive microorganisms, poorly detected by the SimPlate(TM) TPC CI system because they grew slowly and had low reduction capacity. The results indicated a higher efficiency of the SimPlate(TM) TPC CI system in the reading at 48h.
doi_str_mv 10.1590/S1517-83822002000100009
format Article
fullrecord <record><control><sourceid>proquest_sciel</sourceid><recordid>TN_cdi_scielo_journals_S1517_83822002000100009</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1517_83822002000100009</scielo_id><sourcerecordid>2895139691</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-58293b6e70d6a3ba92af640b90d8cfa73120962acb4ce5ae26890ae416684dbc3</originalsourceid><addsrcrecordid>eNp1kd1KwzAUx4MoOKfPYMAbvehM0q_0chQ_BgOFzeuSpqcus226JL2YLyK-jk9m5hQvREg4J8nv_z-cE4TOKZnQOCPXCxrTNOAhZ4wQvwj1m2QHaESTlAdRROJDn_9Ax-jE2rUnYxKxEXqbWgvWttA5rGvsVoChrpVU0Mnt7mah2sdGOPh4x0470eB-d8JSD14hdaMNVl2lpHA-u1w-5jifXXkUbwbROVVvcQtW9yvVKIkFGF362CpptDbPolO2td4A98I6GIx6hcq_Ni-n6KgWjYWz7zhGT7c3y_w-mD_czfLpPJBhGrog5iwLywRSUiUiLEXGRJ1EpMxIxWUt0pAykiVMyDKSEAtgCc-IgIgmCY-qUoZjNNn7Wt9yo4u1HkznCxZfYy3-jNULLvaC3ujNANb9SijjPM1CRqin0j3l-7TWQF30RrXCbAtKit23_ev_CQAqiv8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1288793201</pqid></control><display><type>article</type><title>Assessment of the efficiency of SimPlate™ total plate count color indicator (TPC CI) to quantify mesophilic aerobic microorganisms in pasteurized milk</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Nero, Luís Augusto ; Beloti, Vanerli ; Barros, Márcia de Aguiar Ferreira ; Santana, Elsa Helena Walter de ; Pereira, Mykel Steffani ; Gusmão, Viviane Vieira ; Moraes, Luciane Bilia de</creator><creatorcontrib>Nero, Luís Augusto ; Beloti, Vanerli ; Barros, Márcia de Aguiar Ferreira ; Santana, Elsa Helena Walter de ; Pereira, Mykel Steffani ; Gusmão, Viviane Vieira ; Moraes, Luciane Bilia de</creatorcontrib><description>The SimPlate(TM) TPC CI system is a rapid method to count mesophilic aerobic microorganisms (MAM) in foods, based on the use of resazurine to indicate bacterial growth. Its efficiency in pasteurized milk was evaluated using 142 pasteurized milk samples (38 type A, 43 type B and 61 type C) collected in Londrina, PR. The standard plating method, using Plate Count Agar (PCA) was used for comparison. The plates of both systems were incubated at 35ºC and read after 24h and 48h. The occurrence of false-positive and false-negative wells and the predominant microorganisms in them were also evaluated. The results were compared by simple correlation and mean variance analyses. The correlation (r) and mean variance values were 0.6811 and 0.7583 for the results obtained after 24h, respectively, and 0.9126 and 0.0842 for the results obtained after 48h, respectively. These results indicate that the performance of the system increases when the plates are incubated for 48h. When the three types of milk were evaluated separately, these values were 0.9285 and 0.0817 for type A milk, 0.9231 and 0.0466 for type B milk and 0.7209 and 0.1082 for type C milk. These results indicate that the better the quality of the milk the better the performance of SimPlate(TM) TPC CI. False-negative wells, found more frequently in samples with high MAM counts, were caused by Gram positive microorganisms, poorly detected by the SimPlate(TM) TPC CI system because they grew slowly and had low reduction capacity. The results indicated a higher efficiency of the SimPlate(TM) TPC CI system in the reading at 48h.</description><identifier>ISSN: 1517-8382</identifier><identifier>ISSN: 1678-4405</identifier><identifier>EISSN: 1678-4405</identifier><identifier>DOI: 10.1590/S1517-83822002000100009</identifier><language>eng</language><publisher>São Paulo: Springer Nature B.V</publisher><subject>MICROBIOLOGY</subject><ispartof>Brazilian journal of microbiology, 2002-01, Vol.33 (1), p.44-48</ispartof><rights>Copyright Sociedade Brasileira de Microbiologia 2002</rights><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-58293b6e70d6a3ba92af640b90d8cfa73120962acb4ce5ae26890ae416684dbc3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27915,27916</link.rule.ids></links><search><creatorcontrib>Nero, Luís Augusto</creatorcontrib><creatorcontrib>Beloti, Vanerli</creatorcontrib><creatorcontrib>Barros, Márcia de Aguiar Ferreira</creatorcontrib><creatorcontrib>Santana, Elsa Helena Walter de</creatorcontrib><creatorcontrib>Pereira, Mykel Steffani</creatorcontrib><creatorcontrib>Gusmão, Viviane Vieira</creatorcontrib><creatorcontrib>Moraes, Luciane Bilia de</creatorcontrib><title>Assessment of the efficiency of SimPlate™ total plate count color indicator (TPC CI) to quantify mesophilic aerobic microorganisms in pasteurized milk</title><title>Brazilian journal of microbiology</title><addtitle>Braz. J. Microbiol</addtitle><description>The SimPlate(TM) TPC CI system is a rapid method to count mesophilic aerobic microorganisms (MAM) in foods, based on the use of resazurine to indicate bacterial growth. Its efficiency in pasteurized milk was evaluated using 142 pasteurized milk samples (38 type A, 43 type B and 61 type C) collected in Londrina, PR. The standard plating method, using Plate Count Agar (PCA) was used for comparison. The plates of both systems were incubated at 35ºC and read after 24h and 48h. The occurrence of false-positive and false-negative wells and the predominant microorganisms in them were also evaluated. The results were compared by simple correlation and mean variance analyses. The correlation (r) and mean variance values were 0.6811 and 0.7583 for the results obtained after 24h, respectively, and 0.9126 and 0.0842 for the results obtained after 48h, respectively. These results indicate that the performance of the system increases when the plates are incubated for 48h. When the three types of milk were evaluated separately, these values were 0.9285 and 0.0817 for type A milk, 0.9231 and 0.0466 for type B milk and 0.7209 and 0.1082 for type C milk. These results indicate that the better the quality of the milk the better the performance of SimPlate(TM) TPC CI. False-negative wells, found more frequently in samples with high MAM counts, were caused by Gram positive microorganisms, poorly detected by the SimPlate(TM) TPC CI system because they grew slowly and had low reduction capacity. The results indicated a higher efficiency of the SimPlate(TM) TPC CI system in the reading at 48h.</description><subject>MICROBIOLOGY</subject><issn>1517-8382</issn><issn>1678-4405</issn><issn>1678-4405</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNp1kd1KwzAUx4MoOKfPYMAbvehM0q_0chQ_BgOFzeuSpqcus226JL2YLyK-jk9m5hQvREg4J8nv_z-cE4TOKZnQOCPXCxrTNOAhZ4wQvwj1m2QHaESTlAdRROJDn_9Ax-jE2rUnYxKxEXqbWgvWttA5rGvsVoChrpVU0Mnt7mah2sdGOPh4x0470eB-d8JSD14hdaMNVl2lpHA-u1w-5jifXXkUbwbROVVvcQtW9yvVKIkFGF362CpptDbPolO2td4A98I6GIx6hcq_Ni-n6KgWjYWz7zhGT7c3y_w-mD_czfLpPJBhGrog5iwLywRSUiUiLEXGRJ1EpMxIxWUt0pAykiVMyDKSEAtgCc-IgIgmCY-qUoZjNNn7Wt9yo4u1HkznCxZfYy3-jNULLvaC3ujNANb9SijjPM1CRqin0j3l-7TWQF30RrXCbAtKit23_ev_CQAqiv8</recordid><startdate>200201</startdate><enddate>200201</enddate><creator>Nero, Luís Augusto</creator><creator>Beloti, Vanerli</creator><creator>Barros, Márcia de Aguiar Ferreira</creator><creator>Santana, Elsa Helena Walter de</creator><creator>Pereira, Mykel Steffani</creator><creator>Gusmão, Viviane Vieira</creator><creator>Moraes, Luciane Bilia de</creator><general>Springer Nature B.V</general><general>Sociedade Brasileira de Microbiologia</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QL</scope><scope>7U9</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>88I</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>ATCPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>C1K</scope><scope>CCPQU</scope><scope>CLZPN</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H94</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>M7N</scope><scope>M7P</scope><scope>PATMY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PYCSY</scope><scope>Q9U</scope><scope>GPN</scope></search><sort><creationdate>200201</creationdate><title>Assessment of the efficiency of SimPlate™ total plate count color indicator (TPC CI) to quantify mesophilic aerobic microorganisms in pasteurized milk</title><author>Nero, Luís Augusto ; Beloti, Vanerli ; Barros, Márcia de Aguiar Ferreira ; Santana, Elsa Helena Walter de ; Pereira, Mykel Steffani ; Gusmão, Viviane Vieira ; Moraes, Luciane Bilia de</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-58293b6e70d6a3ba92af640b90d8cfa73120962acb4ce5ae26890ae416684dbc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>MICROBIOLOGY</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nero, Luís Augusto</creatorcontrib><creatorcontrib>Beloti, Vanerli</creatorcontrib><creatorcontrib>Barros, Márcia de Aguiar Ferreira</creatorcontrib><creatorcontrib>Santana, Elsa Helena Walter de</creatorcontrib><creatorcontrib>Pereira, Mykel Steffani</creatorcontrib><creatorcontrib>Gusmão, Viviane Vieira</creatorcontrib><creatorcontrib>Moraes, Luciane Bilia de</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Virology and AIDS Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central UK/Ireland</collection><collection>Agricultural &amp; Environmental Science Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>Latin America &amp; Iberia Database</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Science Database</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biological Science Database</collection><collection>Environmental Science Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Environmental Science Collection</collection><collection>ProQuest Central Basic</collection><collection>SciELO</collection><jtitle>Brazilian journal of microbiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nero, Luís Augusto</au><au>Beloti, Vanerli</au><au>Barros, Márcia de Aguiar Ferreira</au><au>Santana, Elsa Helena Walter de</au><au>Pereira, Mykel Steffani</au><au>Gusmão, Viviane Vieira</au><au>Moraes, Luciane Bilia de</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessment of the efficiency of SimPlate™ total plate count color indicator (TPC CI) to quantify mesophilic aerobic microorganisms in pasteurized milk</atitle><jtitle>Brazilian journal of microbiology</jtitle><addtitle>Braz. J. Microbiol</addtitle><date>2002-01</date><risdate>2002</risdate><volume>33</volume><issue>1</issue><spage>44</spage><epage>48</epage><pages>44-48</pages><issn>1517-8382</issn><issn>1678-4405</issn><eissn>1678-4405</eissn><abstract>The SimPlate(TM) TPC CI system is a rapid method to count mesophilic aerobic microorganisms (MAM) in foods, based on the use of resazurine to indicate bacterial growth. Its efficiency in pasteurized milk was evaluated using 142 pasteurized milk samples (38 type A, 43 type B and 61 type C) collected in Londrina, PR. The standard plating method, using Plate Count Agar (PCA) was used for comparison. The plates of both systems were incubated at 35ºC and read after 24h and 48h. The occurrence of false-positive and false-negative wells and the predominant microorganisms in them were also evaluated. The results were compared by simple correlation and mean variance analyses. The correlation (r) and mean variance values were 0.6811 and 0.7583 for the results obtained after 24h, respectively, and 0.9126 and 0.0842 for the results obtained after 48h, respectively. These results indicate that the performance of the system increases when the plates are incubated for 48h. When the three types of milk were evaluated separately, these values were 0.9285 and 0.0817 for type A milk, 0.9231 and 0.0466 for type B milk and 0.7209 and 0.1082 for type C milk. These results indicate that the better the quality of the milk the better the performance of SimPlate(TM) TPC CI. False-negative wells, found more frequently in samples with high MAM counts, were caused by Gram positive microorganisms, poorly detected by the SimPlate(TM) TPC CI system because they grew slowly and had low reduction capacity. The results indicated a higher efficiency of the SimPlate(TM) TPC CI system in the reading at 48h.</abstract><cop>São Paulo</cop><pub>Springer Nature B.V</pub><doi>10.1590/S1517-83822002000100009</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1517-8382
ispartof Brazilian journal of microbiology, 2002-01, Vol.33 (1), p.44-48
issn 1517-8382
1678-4405
1678-4405
language eng
recordid cdi_scielo_journals_S1517_83822002000100009
source EZB-FREE-00999 freely available EZB journals
subjects MICROBIOLOGY
title Assessment of the efficiency of SimPlate™ total plate count color indicator (TPC CI) to quantify mesophilic aerobic microorganisms in pasteurized milk
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T22%3A33%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_sciel&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessment%20of%20the%20efficiency%20of%20SimPlate%C2%99%20total%20plate%20count%20color%20indicator%20(TPC%20CI)%20to%20quantify%20mesophilic%20aerobic%20microorganisms%20in%20pasteurized%20milk&rft.jtitle=Brazilian%20journal%20of%20microbiology&rft.au=Nero,%20Lu%C3%ADs%20Augusto&rft.date=2002-01&rft.volume=33&rft.issue=1&rft.spage=44&rft.epage=48&rft.pages=44-48&rft.issn=1517-8382&rft.eissn=1678-4405&rft_id=info:doi/10.1590/S1517-83822002000100009&rft_dat=%3Cproquest_sciel%3E2895139691%3C/proquest_sciel%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1288793201&rft_id=info:pmid/&rft_scielo_id=S1517_83822002000100009&rfr_iscdi=true