Influence of the number of layers of paris bandage plasters on the mechanical properties speciments used on orthopedic splints

To evaluate the effects of varying numbers of layers of plaster of Paris bandages on the mechanical properties of specimens used on the construction of orthopedic splints. Rectangular plate-shaped and cylinder-shaped specimens were constructed and assigned to two groups simulating plaster slabs and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil)) Brazil)), 2011-10, Vol.15 (5), p.380-386
Hauptverfasser: Vieira, Gustavo C, Barbosa, Rafael I, Marcolino, Alexandre M, Shimano, Antonio C, Elui, Valeria M C, Fonseca, Marisa C R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 386
container_issue 5
container_start_page 380
container_title Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil))
container_volume 15
creator Vieira, Gustavo C
Barbosa, Rafael I
Marcolino, Alexandre M
Shimano, Antonio C
Elui, Valeria M C
Fonseca, Marisa C R
description To evaluate the effects of varying numbers of layers of plaster of Paris bandages on the mechanical properties of specimens used on the construction of orthopedic splints. Rectangular plate-shaped and cylinder-shaped specimens were constructed and assigned to two groups simulating plaster slabs and cast and further divided into six subgroups according to the number of layers used: 3, 6, 8, 10, 12 and 14 layers. The specimens were subjected to either a three-point bending test (plates/slab) or compressive strength test (cylinders/cast). The following mechanical properties were evaluated: maximum load, elastic limit load and stiffness. Specimen weight was also calculated. Data was analyzed using Kruskal-Wallis and the least significant difference (LSD) tests. Pairwise comparisons of the subgroups 10x12 and 10x14 revealed significant differences for all mechanical properties (p
doi_str_mv 10.1590/S1413-35552011005000018
format Article
fullrecord <record><control><sourceid>scielo_cross</sourceid><recordid>TN_cdi_scielo_journals_S1413_35552011000500007</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1413_35552011000500007</scielo_id><sourcerecordid>S1413_35552011000500007</sourcerecordid><originalsourceid>FETCH-LOGICAL-c298t-10a5932cbea377693ddc51b09519d07b38f0272329ce2d26f0f39ccc1b0955463</originalsourceid><addsrcrecordid>eNplkLtOwzAUQD2AaCn8AvgHWvyo43hEFY9KlRiAOXLsG-oqL9nJ0IVvx0lKGfBiW-ceWzoI3VOyokKRh3e6pnzJhRCMUEqIIHHR9ALNz2CGrkM4RJRSRq7QjNFUSpLQOfre1kXZQ20ANwXu9oDrvsrBD7dSH8GH4dRq7wLOdW31F-C21KEbST0aFZi9rp3RJW5904LvHAQcWjCugroLuA9gh-HGd_vIrTORli6iG3RZ6DLA7WlfoM_np4_N63L39rLdPO6Whqm0W1KiheLM5KC5lIni1hpBc6IEVZbInKcFYZJxpgwwy5KCFFwZY8YRsU74Aq2md4NxUDbZoel9HT_MxnjZX7ypnoyCnATjmxA8FFnrXaX9MaMkG7L_M0_Zo3k3mW2fV2DP3m9z_gPgcH7s</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Influence of the number of layers of paris bandage plasters on the mechanical properties speciments used on orthopedic splints</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Vieira, Gustavo C ; Barbosa, Rafael I ; Marcolino, Alexandre M ; Shimano, Antonio C ; Elui, Valeria M C ; Fonseca, Marisa C R</creator><creatorcontrib>Vieira, Gustavo C ; Barbosa, Rafael I ; Marcolino, Alexandre M ; Shimano, Antonio C ; Elui, Valeria M C ; Fonseca, Marisa C R</creatorcontrib><description>To evaluate the effects of varying numbers of layers of plaster of Paris bandages on the mechanical properties of specimens used on the construction of orthopedic splints. Rectangular plate-shaped and cylinder-shaped specimens were constructed and assigned to two groups simulating plaster slabs and cast and further divided into six subgroups according to the number of layers used: 3, 6, 8, 10, 12 and 14 layers. The specimens were subjected to either a three-point bending test (plates/slab) or compressive strength test (cylinders/cast). The following mechanical properties were evaluated: maximum load, elastic limit load and stiffness. Specimen weight was also calculated. Data was analyzed using Kruskal-Wallis and the least significant difference (LSD) tests. Pairwise comparisons of the subgroups 10x12 and 10x14 revealed significant differences for all mechanical properties (p&lt;0.05). The results of this study suggest that when the goal is to construct appliances with high mechanical strength, regardless of weight, such as serial plaster slabs splints for stimulating tissue growth through the application of gradual load, splints made with plaster of Paris bandages with 12 or 14 layers should be preferred. For orthotic devices such as positioning orthotics, the use of 10 layers plaster bandages slab splints is advisable as they were found to have better correlation between mechanical strength and weight in comparison to those made wtih 6 or 8 layers. Based on the findings of this study, we suggest the use of 10 layers of plaster of Paris for the construction of orthopedic splints.</description><identifier>ISSN: 1413-3555</identifier><identifier>ISSN: 1809-9246</identifier><identifier>DOI: 10.1590/S1413-35552011005000018</identifier><identifier>PMID: 21877061</identifier><language>eng</language><publisher>Brazil: Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia</publisher><subject>Calcium Sulfate ; Casts, Surgical ; Humans ; Materials Testing ; Mechanical Phenomena ; ORTHOPEDICS ; REHABILITATION ; Splints</subject><ispartof>Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil)), 2011-10, Vol.15 (5), p.380-386</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c298t-10a5932cbea377693ddc51b09519d07b38f0272329ce2d26f0f39ccc1b0955463</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21877061$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Vieira, Gustavo C</creatorcontrib><creatorcontrib>Barbosa, Rafael I</creatorcontrib><creatorcontrib>Marcolino, Alexandre M</creatorcontrib><creatorcontrib>Shimano, Antonio C</creatorcontrib><creatorcontrib>Elui, Valeria M C</creatorcontrib><creatorcontrib>Fonseca, Marisa C R</creatorcontrib><title>Influence of the number of layers of paris bandage plasters on the mechanical properties speciments used on orthopedic splints</title><title>Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil))</title><addtitle>Rev Bras Fisioter</addtitle><description>To evaluate the effects of varying numbers of layers of plaster of Paris bandages on the mechanical properties of specimens used on the construction of orthopedic splints. Rectangular plate-shaped and cylinder-shaped specimens were constructed and assigned to two groups simulating plaster slabs and cast and further divided into six subgroups according to the number of layers used: 3, 6, 8, 10, 12 and 14 layers. The specimens were subjected to either a three-point bending test (plates/slab) or compressive strength test (cylinders/cast). The following mechanical properties were evaluated: maximum load, elastic limit load and stiffness. Specimen weight was also calculated. Data was analyzed using Kruskal-Wallis and the least significant difference (LSD) tests. Pairwise comparisons of the subgroups 10x12 and 10x14 revealed significant differences for all mechanical properties (p&lt;0.05). The results of this study suggest that when the goal is to construct appliances with high mechanical strength, regardless of weight, such as serial plaster slabs splints for stimulating tissue growth through the application of gradual load, splints made with plaster of Paris bandages with 12 or 14 layers should be preferred. For orthotic devices such as positioning orthotics, the use of 10 layers plaster bandages slab splints is advisable as they were found to have better correlation between mechanical strength and weight in comparison to those made wtih 6 or 8 layers. Based on the findings of this study, we suggest the use of 10 layers of plaster of Paris for the construction of orthopedic splints.</description><subject>Calcium Sulfate</subject><subject>Casts, Surgical</subject><subject>Humans</subject><subject>Materials Testing</subject><subject>Mechanical Phenomena</subject><subject>ORTHOPEDICS</subject><subject>REHABILITATION</subject><subject>Splints</subject><issn>1413-3555</issn><issn>1809-9246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNplkLtOwzAUQD2AaCn8AvgHWvyo43hEFY9KlRiAOXLsG-oqL9nJ0IVvx0lKGfBiW-ceWzoI3VOyokKRh3e6pnzJhRCMUEqIIHHR9ALNz2CGrkM4RJRSRq7QjNFUSpLQOfre1kXZQ20ANwXu9oDrvsrBD7dSH8GH4dRq7wLOdW31F-C21KEbST0aFZi9rp3RJW5904LvHAQcWjCugroLuA9gh-HGd_vIrTORli6iG3RZ6DLA7WlfoM_np4_N63L39rLdPO6Whqm0W1KiheLM5KC5lIni1hpBc6IEVZbInKcFYZJxpgwwy5KCFFwZY8YRsU74Aq2md4NxUDbZoel9HT_MxnjZX7ypnoyCnATjmxA8FFnrXaX9MaMkG7L_M0_Zo3k3mW2fV2DP3m9z_gPgcH7s</recordid><startdate>20111001</startdate><enddate>20111001</enddate><creator>Vieira, Gustavo C</creator><creator>Barbosa, Rafael I</creator><creator>Marcolino, Alexandre M</creator><creator>Shimano, Antonio C</creator><creator>Elui, Valeria M C</creator><creator>Fonseca, Marisa C R</creator><general>Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope></search><sort><creationdate>20111001</creationdate><title>Influence of the number of layers of paris bandage plasters on the mechanical properties speciments used on orthopedic splints</title><author>Vieira, Gustavo C ; Barbosa, Rafael I ; Marcolino, Alexandre M ; Shimano, Antonio C ; Elui, Valeria M C ; Fonseca, Marisa C R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c298t-10a5932cbea377693ddc51b09519d07b38f0272329ce2d26f0f39ccc1b0955463</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Calcium Sulfate</topic><topic>Casts, Surgical</topic><topic>Humans</topic><topic>Materials Testing</topic><topic>Mechanical Phenomena</topic><topic>ORTHOPEDICS</topic><topic>REHABILITATION</topic><topic>Splints</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vieira, Gustavo C</creatorcontrib><creatorcontrib>Barbosa, Rafael I</creatorcontrib><creatorcontrib>Marcolino, Alexandre M</creatorcontrib><creatorcontrib>Shimano, Antonio C</creatorcontrib><creatorcontrib>Elui, Valeria M C</creatorcontrib><creatorcontrib>Fonseca, Marisa C R</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>SciELO</collection><jtitle>Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil))</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vieira, Gustavo C</au><au>Barbosa, Rafael I</au><au>Marcolino, Alexandre M</au><au>Shimano, Antonio C</au><au>Elui, Valeria M C</au><au>Fonseca, Marisa C R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of the number of layers of paris bandage plasters on the mechanical properties speciments used on orthopedic splints</atitle><jtitle>Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil))</jtitle><addtitle>Rev Bras Fisioter</addtitle><date>2011-10-01</date><risdate>2011</risdate><volume>15</volume><issue>5</issue><spage>380</spage><epage>386</epage><pages>380-386</pages><issn>1413-3555</issn><issn>1809-9246</issn><abstract>To evaluate the effects of varying numbers of layers of plaster of Paris bandages on the mechanical properties of specimens used on the construction of orthopedic splints. Rectangular plate-shaped and cylinder-shaped specimens were constructed and assigned to two groups simulating plaster slabs and cast and further divided into six subgroups according to the number of layers used: 3, 6, 8, 10, 12 and 14 layers. The specimens were subjected to either a three-point bending test (plates/slab) or compressive strength test (cylinders/cast). The following mechanical properties were evaluated: maximum load, elastic limit load and stiffness. Specimen weight was also calculated. Data was analyzed using Kruskal-Wallis and the least significant difference (LSD) tests. Pairwise comparisons of the subgroups 10x12 and 10x14 revealed significant differences for all mechanical properties (p&lt;0.05). The results of this study suggest that when the goal is to construct appliances with high mechanical strength, regardless of weight, such as serial plaster slabs splints for stimulating tissue growth through the application of gradual load, splints made with plaster of Paris bandages with 12 or 14 layers should be preferred. For orthotic devices such as positioning orthotics, the use of 10 layers plaster bandages slab splints is advisable as they were found to have better correlation between mechanical strength and weight in comparison to those made wtih 6 or 8 layers. Based on the findings of this study, we suggest the use of 10 layers of plaster of Paris for the construction of orthopedic splints.</abstract><cop>Brazil</cop><pub>Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia</pub><pmid>21877061</pmid><doi>10.1590/S1413-35552011005000018</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1413-3555
ispartof Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil)), 2011-10, Vol.15 (5), p.380-386
issn 1413-3555
1809-9246
language eng
recordid cdi_scielo_journals_S1413_35552011000500007
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Calcium Sulfate
Casts, Surgical
Humans
Materials Testing
Mechanical Phenomena
ORTHOPEDICS
REHABILITATION
Splints
title Influence of the number of layers of paris bandage plasters on the mechanical properties speciments used on orthopedic splints
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-20T20%3A12%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20the%20number%20of%20layers%20of%20paris%20bandage%20plasters%20on%20the%20mechanical%20properties%20speciments%20used%20on%20orthopedic%20splints&rft.jtitle=Revista%20brasileira%20de%20fisioterapia%20(Sao%20Carlos%20(Sao%20Paulo,%20Brazil))&rft.au=Vieira,%20Gustavo%20C&rft.date=2011-10-01&rft.volume=15&rft.issue=5&rft.spage=380&rft.epage=386&rft.pages=380-386&rft.issn=1413-3555&rft_id=info:doi/10.1590/S1413-35552011005000018&rft_dat=%3Cscielo_cross%3ES1413_35552011000500007%3C/scielo_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/21877061&rft_scielo_id=S1413_35552011000500007&rfr_iscdi=true