Investigation of the earthquake behavior of the historical Adana great clock tower using FEM updated based on environmental vibration data

In this study, the historical Adana great clock tower's dynamic characteristics (natural frequencies and mode shapes) were determined using the operational modal analysis (OMA) method. The finite element model (FEM) of the Clock Tower was updated based on the experimentally obtained dynamic cha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Revista de la construcción 2024-08, Vol.23 (2), p.335-353
Hauptverfasser: Erkek, Hakan, Yetkin, Musa, Calayır, Yusuf
Format: Artikel
Sprache:eng ; por
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 353
container_issue 2
container_start_page 335
container_title Revista de la construcción
container_volume 23
creator Erkek, Hakan
Yetkin, Musa
Calayır, Yusuf
description In this study, the historical Adana great clock tower's dynamic characteristics (natural frequencies and mode shapes) were determined using the operational modal analysis (OMA) method. The finite element model (FEM) of the Clock Tower was updated based on the experimentally obtained dynamic characteristics. The update process was performed manually using the material properties of the Clock Tower. Linear dynamic analyses of the structures under earthquake loadings were performed using its updated finite element model. The acceleration records of the 1998 Adana-Ceyhan earthquake, scaled according to the horizontal elastic design spectrum defined in TBEC (2018) were used for dynamic input. The displacements, maximum and minimum principal stresses of the Clock Tower were obtained and evaluated. As a result of the analyses, it was determined that there was a potential for damage to the Clock Tower due to exceeding the tensile strength of the walls, but the potential for damage to the Clock Tower due to exceeding the compressive strength of the walls is weak.
doi_str_mv 10.7764/RDLC.23.2.335
format Article
fullrecord <record><control><sourceid>scielo_cross</sourceid><recordid>TN_cdi_scielo_journals_S0718_915X2024000200335</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S0718_915X2024000200335</scielo_id><sourcerecordid>S0718_915X2024000200335</sourcerecordid><originalsourceid>FETCH-LOGICAL-c775-1d25adfaebc0ff38ff4cb152349239c15769126dd2201e4ec440c231edd902573</originalsourceid><addsrcrecordid>eNpNkE1OwzAQhS0EEhV0yd4XSPBP0jTLqrRQqQgJumBnOfakcZvGxXaDuAKnxlFBYhYzI82b96QPoTtK0qKYZPevD-t5ynjKUs7zCzQiBZ0mJc3fL__t12js_Y7E4mU2LckIfa-6HnwwWxmM7bCtcWgAg3Sh-TjJPeAKGtkb6_5OjfHBOqNki2dadhJvHciAVWvVHgf7CQ6fvOm2eLl4xqejlgE0rqSPPfpD1xtnuwN0IRr0pnLn3CiTt-iqlq2H8e-8QZvlYjN_StYvj6v5bJ2oosgTqlkudS2hUqSu-bSuM1XRnPGsZLxUNC8mJWUTrRkjFDJQWUYU4xS0LgnLC36D0rOtVwZaK3b25LqYJ94GTGLAxAjLIiMWMfE8PiTnB-Ws9w5qcXTmIN2XoEQM7MXAXjAumBj0P4Ttd2E</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Investigation of the earthquake behavior of the historical Adana great clock tower using FEM updated based on environmental vibration data</title><source>EZB Electronic Journals Library</source><creator>Erkek, Hakan ; Yetkin, Musa ; Calayır, Yusuf</creator><creatorcontrib>Erkek, Hakan ; Yetkin, Musa ; Calayır, Yusuf</creatorcontrib><description>In this study, the historical Adana great clock tower's dynamic characteristics (natural frequencies and mode shapes) were determined using the operational modal analysis (OMA) method. The finite element model (FEM) of the Clock Tower was updated based on the experimentally obtained dynamic characteristics. The update process was performed manually using the material properties of the Clock Tower. Linear dynamic analyses of the structures under earthquake loadings were performed using its updated finite element model. The acceleration records of the 1998 Adana-Ceyhan earthquake, scaled according to the horizontal elastic design spectrum defined in TBEC (2018) were used for dynamic input. The displacements, maximum and minimum principal stresses of the Clock Tower were obtained and evaluated. As a result of the analyses, it was determined that there was a potential for damage to the Clock Tower due to exceeding the tensile strength of the walls, but the potential for damage to the Clock Tower due to exceeding the compressive strength of the walls is weak.</description><identifier>ISSN: 0718-915X</identifier><identifier>EISSN: 0718-915X</identifier><identifier>DOI: 10.7764/RDLC.23.2.335</identifier><language>eng ; por</language><publisher>Escuela de Construcción Civil, Pontificia Universidad Católica de Chile</publisher><subject>CONSTRUCTION &amp; BUILDING TECHNOLOGY ; ENGINEERING, CIVIL</subject><ispartof>Revista de la construcción, 2024-08, Vol.23 (2), p.335-353</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids></links><search><creatorcontrib>Erkek, Hakan</creatorcontrib><creatorcontrib>Yetkin, Musa</creatorcontrib><creatorcontrib>Calayır, Yusuf</creatorcontrib><title>Investigation of the earthquake behavior of the historical Adana great clock tower using FEM updated based on environmental vibration data</title><title>Revista de la construcción</title><addtitle>Revista de la Construcción</addtitle><description>In this study, the historical Adana great clock tower's dynamic characteristics (natural frequencies and mode shapes) were determined using the operational modal analysis (OMA) method. The finite element model (FEM) of the Clock Tower was updated based on the experimentally obtained dynamic characteristics. The update process was performed manually using the material properties of the Clock Tower. Linear dynamic analyses of the structures under earthquake loadings were performed using its updated finite element model. The acceleration records of the 1998 Adana-Ceyhan earthquake, scaled according to the horizontal elastic design spectrum defined in TBEC (2018) were used for dynamic input. The displacements, maximum and minimum principal stresses of the Clock Tower were obtained and evaluated. As a result of the analyses, it was determined that there was a potential for damage to the Clock Tower due to exceeding the tensile strength of the walls, but the potential for damage to the Clock Tower due to exceeding the compressive strength of the walls is weak.</description><subject>CONSTRUCTION &amp; BUILDING TECHNOLOGY</subject><subject>ENGINEERING, CIVIL</subject><issn>0718-915X</issn><issn>0718-915X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpNkE1OwzAQhS0EEhV0yd4XSPBP0jTLqrRQqQgJumBnOfakcZvGxXaDuAKnxlFBYhYzI82b96QPoTtK0qKYZPevD-t5ynjKUs7zCzQiBZ0mJc3fL__t12js_Y7E4mU2LckIfa-6HnwwWxmM7bCtcWgAg3Sh-TjJPeAKGtkb6_5OjfHBOqNki2dadhJvHciAVWvVHgf7CQ6fvOm2eLl4xqejlgE0rqSPPfpD1xtnuwN0IRr0pnLn3CiTt-iqlq2H8e-8QZvlYjN_StYvj6v5bJ2oosgTqlkudS2hUqSu-bSuM1XRnPGsZLxUNC8mJWUTrRkjFDJQWUYU4xS0LgnLC36D0rOtVwZaK3b25LqYJ94GTGLAxAjLIiMWMfE8PiTnB-Ws9w5qcXTmIN2XoEQM7MXAXjAumBj0P4Ttd2E</recordid><startdate>202408</startdate><enddate>202408</enddate><creator>Erkek, Hakan</creator><creator>Yetkin, Musa</creator><creator>Calayır, Yusuf</creator><general>Escuela de Construcción Civil, Pontificia Universidad Católica de Chile</general><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope></search><sort><creationdate>202408</creationdate><title>Investigation of the earthquake behavior of the historical Adana great clock tower using FEM updated based on environmental vibration data</title><author>Erkek, Hakan ; Yetkin, Musa ; Calayır, Yusuf</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c775-1d25adfaebc0ff38ff4cb152349239c15769126dd2201e4ec440c231edd902573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; por</language><creationdate>2024</creationdate><topic>CONSTRUCTION &amp; BUILDING TECHNOLOGY</topic><topic>ENGINEERING, CIVIL</topic><toplevel>online_resources</toplevel><creatorcontrib>Erkek, Hakan</creatorcontrib><creatorcontrib>Yetkin, Musa</creatorcontrib><creatorcontrib>Calayır, Yusuf</creatorcontrib><collection>CrossRef</collection><collection>SciELO</collection><jtitle>Revista de la construcción</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Erkek, Hakan</au><au>Yetkin, Musa</au><au>Calayır, Yusuf</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Investigation of the earthquake behavior of the historical Adana great clock tower using FEM updated based on environmental vibration data</atitle><jtitle>Revista de la construcción</jtitle><addtitle>Revista de la Construcción</addtitle><date>2024-08</date><risdate>2024</risdate><volume>23</volume><issue>2</issue><spage>335</spage><epage>353</epage><pages>335-353</pages><issn>0718-915X</issn><eissn>0718-915X</eissn><abstract>In this study, the historical Adana great clock tower's dynamic characteristics (natural frequencies and mode shapes) were determined using the operational modal analysis (OMA) method. The finite element model (FEM) of the Clock Tower was updated based on the experimentally obtained dynamic characteristics. The update process was performed manually using the material properties of the Clock Tower. Linear dynamic analyses of the structures under earthquake loadings were performed using its updated finite element model. The acceleration records of the 1998 Adana-Ceyhan earthquake, scaled according to the horizontal elastic design spectrum defined in TBEC (2018) were used for dynamic input. The displacements, maximum and minimum principal stresses of the Clock Tower were obtained and evaluated. As a result of the analyses, it was determined that there was a potential for damage to the Clock Tower due to exceeding the tensile strength of the walls, but the potential for damage to the Clock Tower due to exceeding the compressive strength of the walls is weak.</abstract><pub>Escuela de Construcción Civil, Pontificia Universidad Católica de Chile</pub><doi>10.7764/RDLC.23.2.335</doi><tpages>19</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0718-915X
ispartof Revista de la construcción, 2024-08, Vol.23 (2), p.335-353
issn 0718-915X
0718-915X
language eng ; por
recordid cdi_scielo_journals_S0718_915X2024000200335
source EZB Electronic Journals Library
subjects CONSTRUCTION & BUILDING TECHNOLOGY
ENGINEERING, CIVIL
title Investigation of the earthquake behavior of the historical Adana great clock tower using FEM updated based on environmental vibration data
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T08%3A27%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Investigation%20of%20the%20earthquake%20behavior%20of%20the%20historical%20Adana%20great%20clock%20tower%20using%20FEM%20updated%20based%20on%20environmental%20vibration%20data&rft.jtitle=Revista%20de%20la%20construcci%C3%B3n&rft.au=Erkek,%20Hakan&rft.date=2024-08&rft.volume=23&rft.issue=2&rft.spage=335&rft.epage=353&rft.pages=335-353&rft.issn=0718-915X&rft.eissn=0718-915X&rft_id=info:doi/10.7764/RDLC.23.2.335&rft_dat=%3Cscielo_cross%3ES0718_915X2024000200335%3C/scielo_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S0718_915X2024000200335&rfr_iscdi=true