Accuracy in the Diagnosis of the Mental Nerve Loop. A Comparative Study Between Panoramic Radiography and Cone Beam Computed Tomography
Dental implant and chin osteotomy are executed on the mandible body and the mental nerve is an important anatomical limit. The aim of this research was to know the position of the mental nerve loop comparing result in panoramic radiography and cone beam computed tomography. We analyzed 94 hemimandib...
Gespeichert in:
Veröffentlicht in: | International journal of morphology 2015-03, Vol.33 (1), p.327-332 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 332 |
---|---|
container_issue | 1 |
container_start_page | 327 |
container_title | International journal of morphology |
container_volume | 33 |
creator | do Couto-Filho, Carlos Eduardo Gomes de Moraes, Paulo Hemerson Alonso, Maria Beatriz Carrazzone Haiter-Neto, Francisco Olate, Sergio de Albergaria-Barbosa, José Ricardo |
description | Dental implant and chin osteotomy are executed on the mandible body and the mental nerve is an important anatomical limit. The aim of this research was to know the position of the mental nerve loop comparing result in panoramic radiography and cone beam computed tomography. We analyzed 94 hemimandibles and the patient sample comprised female and male subjects of ages ranging from 18 to 52 years (mean age, 35 years) selected randomly from the database of patients at the Division of Oral Radiology at Piracicaba Dental School State University of Campinas; the anterior loop (AL) of the mental nerve was evaluated regarding the presence or absence, which was classified as rectilinear or curvilinear and measurement of its length was obtained. The observations were made in the digital panoramic radiography (PR) and the cone beam computed tomography (CBCT) according to a routine technique. The frequencies of the AL identified through PR and CBCT were different: in PR the loop was identified in 42.6% of cases, and only 12.8% were bilateral. In contrast, the AL was detected in 29.8% of the samples using CBCT, with 6.4% being bilateral; Statistical comparison between PR and CBCT showed that the PR led to false-positive diagnosis of the AL in this sample. According to the results of this study, the frequency of AL is low. Thus, it can be assumed that it is not a common condition in this population. |
doi_str_mv | 10.4067/S0717-95022015000100051 |
format | Article |
fullrecord | <record><control><sourceid>proquest_sciel</sourceid><recordid>TN_cdi_scielo_journals_S0717_95022015000100051</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S0717_95022015000100051</scielo_id><sourcerecordid>1835396053</sourcerecordid><originalsourceid>FETCH-LOGICAL-c401t-9687c9b1231f9bc97b4ca176580e06ba91705e7399fa63f20f29169f4b78dc4c3</originalsourceid><addsrcrecordid>eNp9kc9u1DAQxi0EoqXwCq2PXHYZx4kdH7fb8kdaoKLlHE2cSesqsVM7Ae0T8Nqku9tekDhYtj5_v_k0M4ydCVjmoPSHa9BCL0wBWQaiAAAxn0K8YMfPHy-f3lLpI_YmpXuArNBQvGZHmVZKl6Y8Zn9W1k4R7ZY7z8c74hcOb31ILvHQ7oSv5Efs-DeKv4hvQhiWfMXXoR8w4uhm7Xqcmi0_p_E3kedX6EPE3ln-AxsXbiMOd1uOvpkZT7MN-x09jdTwm9AfHG_Zqxa7RO8O9wn7-fHyZv15sfn-6ct6tVnYHMS4MKrU1tQik6I1tTW6zi0KrYoSCFSNRswNkpbGtKhkm0GbGaFMm9e6bGxu5Qlb7usm66gL1X2Yop8Dq91Eq38mOgPv98AQw8NEaax6lyx1HXoKU6pEKQtpFBRytuq91caQUqS2GqLrMW4rAdXj2v4TcnoImeqemmfuaU_yLysXkDs</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835396053</pqid></control><display><type>article</type><title>Accuracy in the Diagnosis of the Mental Nerve Loop. A Comparative Study Between Panoramic Radiography and Cone Beam Computed Tomography</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>do Couto-Filho, Carlos Eduardo Gomes ; de Moraes, Paulo Hemerson ; Alonso, Maria Beatriz Carrazzone ; Haiter-Neto, Francisco ; Olate, Sergio ; de Albergaria-Barbosa, José Ricardo</creator><creatorcontrib>do Couto-Filho, Carlos Eduardo Gomes ; de Moraes, Paulo Hemerson ; Alonso, Maria Beatriz Carrazzone ; Haiter-Neto, Francisco ; Olate, Sergio ; de Albergaria-Barbosa, José Ricardo</creatorcontrib><description>Dental implant and chin osteotomy are executed on the mandible body and the mental nerve is an important anatomical limit. The aim of this research was to know the position of the mental nerve loop comparing result in panoramic radiography and cone beam computed tomography. We analyzed 94 hemimandibles and the patient sample comprised female and male subjects of ages ranging from 18 to 52 years (mean age, 35 years) selected randomly from the database of patients at the Division of Oral Radiology at Piracicaba Dental School State University of Campinas; the anterior loop (AL) of the mental nerve was evaluated regarding the presence or absence, which was classified as rectilinear or curvilinear and measurement of its length was obtained. The observations were made in the digital panoramic radiography (PR) and the cone beam computed tomography (CBCT) according to a routine technique. The frequencies of the AL identified through PR and CBCT were different: in PR the loop was identified in 42.6% of cases, and only 12.8% were bilateral. In contrast, the AL was detected in 29.8% of the samples using CBCT, with 6.4% being bilateral; Statistical comparison between PR and CBCT showed that the PR led to false-positive diagnosis of the AL in this sample. According to the results of this study, the frequency of AL is low. Thus, it can be assumed that it is not a common condition in this population.</description><identifier>ISSN: 0717-9367</identifier><identifier>ISSN: 0717-9502</identifier><identifier>EISSN: 0717-9502</identifier><identifier>DOI: 10.4067/S0717-95022015000100051</identifier><identifier>PMID: 27667898</identifier><language>eng</language><publisher>Chile: Sociedad Chilena de Anatomía</publisher><subject>ANATOMY & MORPHOLOGY</subject><ispartof>International journal of morphology, 2015-03, Vol.33 (1), p.327-332</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c401t-9687c9b1231f9bc97b4ca176580e06ba91705e7399fa63f20f29169f4b78dc4c3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27667898$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>do Couto-Filho, Carlos Eduardo Gomes</creatorcontrib><creatorcontrib>de Moraes, Paulo Hemerson</creatorcontrib><creatorcontrib>Alonso, Maria Beatriz Carrazzone</creatorcontrib><creatorcontrib>Haiter-Neto, Francisco</creatorcontrib><creatorcontrib>Olate, Sergio</creatorcontrib><creatorcontrib>de Albergaria-Barbosa, José Ricardo</creatorcontrib><title>Accuracy in the Diagnosis of the Mental Nerve Loop. A Comparative Study Between Panoramic Radiography and Cone Beam Computed Tomography</title><title>International journal of morphology</title><addtitle>Int J Morphol</addtitle><description>Dental implant and chin osteotomy are executed on the mandible body and the mental nerve is an important anatomical limit. The aim of this research was to know the position of the mental nerve loop comparing result in panoramic radiography and cone beam computed tomography. We analyzed 94 hemimandibles and the patient sample comprised female and male subjects of ages ranging from 18 to 52 years (mean age, 35 years) selected randomly from the database of patients at the Division of Oral Radiology at Piracicaba Dental School State University of Campinas; the anterior loop (AL) of the mental nerve was evaluated regarding the presence or absence, which was classified as rectilinear or curvilinear and measurement of its length was obtained. The observations were made in the digital panoramic radiography (PR) and the cone beam computed tomography (CBCT) according to a routine technique. The frequencies of the AL identified through PR and CBCT were different: in PR the loop was identified in 42.6% of cases, and only 12.8% were bilateral. In contrast, the AL was detected in 29.8% of the samples using CBCT, with 6.4% being bilateral; Statistical comparison between PR and CBCT showed that the PR led to false-positive diagnosis of the AL in this sample. According to the results of this study, the frequency of AL is low. Thus, it can be assumed that it is not a common condition in this population.</description><subject>ANATOMY & MORPHOLOGY</subject><issn>0717-9367</issn><issn>0717-9502</issn><issn>0717-9502</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9kc9u1DAQxi0EoqXwCq2PXHYZx4kdH7fb8kdaoKLlHE2cSesqsVM7Ae0T8Nqku9tekDhYtj5_v_k0M4ydCVjmoPSHa9BCL0wBWQaiAAAxn0K8YMfPHy-f3lLpI_YmpXuArNBQvGZHmVZKl6Y8Zn9W1k4R7ZY7z8c74hcOb31ILvHQ7oSv5Efs-DeKv4hvQhiWfMXXoR8w4uhm7Xqcmi0_p_E3kedX6EPE3ln-AxsXbiMOd1uOvpkZT7MN-x09jdTwm9AfHG_Zqxa7RO8O9wn7-fHyZv15sfn-6ct6tVnYHMS4MKrU1tQik6I1tTW6zi0KrYoSCFSNRswNkpbGtKhkm0GbGaFMm9e6bGxu5Qlb7usm66gL1X2Yop8Dq91Eq38mOgPv98AQw8NEaax6lyx1HXoKU6pEKQtpFBRytuq91caQUqS2GqLrMW4rAdXj2v4TcnoImeqemmfuaU_yLysXkDs</recordid><startdate>20150301</startdate><enddate>20150301</enddate><creator>do Couto-Filho, Carlos Eduardo Gomes</creator><creator>de Moraes, Paulo Hemerson</creator><creator>Alonso, Maria Beatriz Carrazzone</creator><creator>Haiter-Neto, Francisco</creator><creator>Olate, Sergio</creator><creator>de Albergaria-Barbosa, José Ricardo</creator><general>Sociedad Chilena de Anatomía</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>GPN</scope></search><sort><creationdate>20150301</creationdate><title>Accuracy in the Diagnosis of the Mental Nerve Loop. A Comparative Study Between Panoramic Radiography and Cone Beam Computed Tomography</title><author>do Couto-Filho, Carlos Eduardo Gomes ; de Moraes, Paulo Hemerson ; Alonso, Maria Beatriz Carrazzone ; Haiter-Neto, Francisco ; Olate, Sergio ; de Albergaria-Barbosa, José Ricardo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c401t-9687c9b1231f9bc97b4ca176580e06ba91705e7399fa63f20f29169f4b78dc4c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>ANATOMY & MORPHOLOGY</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>do Couto-Filho, Carlos Eduardo Gomes</creatorcontrib><creatorcontrib>de Moraes, Paulo Hemerson</creatorcontrib><creatorcontrib>Alonso, Maria Beatriz Carrazzone</creatorcontrib><creatorcontrib>Haiter-Neto, Francisco</creatorcontrib><creatorcontrib>Olate, Sergio</creatorcontrib><creatorcontrib>de Albergaria-Barbosa, José Ricardo</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>SciELO</collection><jtitle>International journal of morphology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>do Couto-Filho, Carlos Eduardo Gomes</au><au>de Moraes, Paulo Hemerson</au><au>Alonso, Maria Beatriz Carrazzone</au><au>Haiter-Neto, Francisco</au><au>Olate, Sergio</au><au>de Albergaria-Barbosa, José Ricardo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accuracy in the Diagnosis of the Mental Nerve Loop. A Comparative Study Between Panoramic Radiography and Cone Beam Computed Tomography</atitle><jtitle>International journal of morphology</jtitle><addtitle>Int J Morphol</addtitle><date>2015-03-01</date><risdate>2015</risdate><volume>33</volume><issue>1</issue><spage>327</spage><epage>332</epage><pages>327-332</pages><issn>0717-9367</issn><issn>0717-9502</issn><eissn>0717-9502</eissn><abstract>Dental implant and chin osteotomy are executed on the mandible body and the mental nerve is an important anatomical limit. The aim of this research was to know the position of the mental nerve loop comparing result in panoramic radiography and cone beam computed tomography. We analyzed 94 hemimandibles and the patient sample comprised female and male subjects of ages ranging from 18 to 52 years (mean age, 35 years) selected randomly from the database of patients at the Division of Oral Radiology at Piracicaba Dental School State University of Campinas; the anterior loop (AL) of the mental nerve was evaluated regarding the presence or absence, which was classified as rectilinear or curvilinear and measurement of its length was obtained. The observations were made in the digital panoramic radiography (PR) and the cone beam computed tomography (CBCT) according to a routine technique. The frequencies of the AL identified through PR and CBCT were different: in PR the loop was identified in 42.6% of cases, and only 12.8% were bilateral. In contrast, the AL was detected in 29.8% of the samples using CBCT, with 6.4% being bilateral; Statistical comparison between PR and CBCT showed that the PR led to false-positive diagnosis of the AL in this sample. According to the results of this study, the frequency of AL is low. Thus, it can be assumed that it is not a common condition in this population.</abstract><cop>Chile</cop><pub>Sociedad Chilena de Anatomía</pub><pmid>27667898</pmid><doi>10.4067/S0717-95022015000100051</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0717-9367 |
ispartof | International journal of morphology, 2015-03, Vol.33 (1), p.327-332 |
issn | 0717-9367 0717-9502 0717-9502 |
language | eng |
recordid | cdi_scielo_journals_S0717_95022015000100051 |
source | EZB-FREE-00999 freely available EZB journals |
subjects | ANATOMY & MORPHOLOGY |
title | Accuracy in the Diagnosis of the Mental Nerve Loop. A Comparative Study Between Panoramic Radiography and Cone Beam Computed Tomography |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T17%3A11%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_sciel&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accuracy%20in%20the%20Diagnosis%20of%20the%20Mental%20Nerve%20Loop.%20A%20Comparative%20Study%20Between%20Panoramic%20Radiography%20and%20Cone%20Beam%20Computed%20Tomography&rft.jtitle=International%20journal%20of%20morphology&rft.au=do%20Couto-Filho,%20Carlos%20Eduardo%20Gomes&rft.date=2015-03-01&rft.volume=33&rft.issue=1&rft.spage=327&rft.epage=332&rft.pages=327-332&rft.issn=0717-9367&rft.eissn=0717-9502&rft_id=info:doi/10.4067/S0717-95022015000100051&rft_dat=%3Cproquest_sciel%3E1835396053%3C/proquest_sciel%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1835396053&rft_id=info:pmid/27667898&rft_scielo_id=S0717_95022015000100051&rfr_iscdi=true |