Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode

Simple, fast, and inexpensive electroanalytical procedures were developed for the determination of codeine (COD) solely and paracetamol (PCT) and COD simultaneously in pharmaceutical formulations and human body fluids. The methods involve the combination of square-wave voltammetry (SWV) with a catho...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Brazilian Chemical Society 2015-10, Vol.26 (10), p.2159-2168
Hauptverfasser: Santos, Anderson M., Vicentini, Fernando C., Deroco, Patrícia B., Rocha-Filho, Romeu C., Fatibello-Filho, Orlando
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2168
container_issue 10
container_start_page 2159
container_title Journal of the Brazilian Chemical Society
container_volume 26
creator Santos, Anderson M.
Vicentini, Fernando C.
Deroco, Patrícia B.
Rocha-Filho, Romeu C.
Fatibello-Filho, Orlando
description Simple, fast, and inexpensive electroanalytical procedures were developed for the determination of codeine (COD) solely and paracetamol (PCT) and COD simultaneously in pharmaceutical formulations and human body fluids. The methods involve the combination of square-wave voltammetry (SWV) with a cathodically pretreated boron-doped diamond electrode and a 0.2 mol L–1 acetate buffer (pH 4.0) solution as the supporting electrolyte. Significantly low limits of detection were obtained for COD solely or PCT and COD simultaneously: 1.19 or 18 and 14 nmol L–1, respectively. The proposed SWV method was successfully applied in the simultaneous determination of PCT and COD in four samples of pharmaceutical tablets, with results similar (at 98% confidence level) to those obtained using a reference high-performance liquid chromatography (HPLC) method. Additionally, adequate results were obtained when concentrations of PCT and COD were determined in human urine or serum samples by addition-recovery. Clearly, the proposed method is an excellent option for the determination of COD solely or PCT and COD simultaneously.
doi_str_mv 10.5935/0103-5053.20150203
format Article
fullrecord <record><control><sourceid>scielo_cross</sourceid><recordid>TN_cdi_scielo_journals_S0103_50532015001002159</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S0103_50532015001002159</scielo_id><sourcerecordid>S0103_50532015001002159</sourcerecordid><originalsourceid>FETCH-LOGICAL-c330t-fac78684f7cd5a28094a403f4fbea349320ffc84a2e853f44f2c2de267a561a13</originalsourceid><addsrcrecordid>eNo9UUFOwzAQ9AEkSuEDnPyBFMeO2_QIaaFIlahUCsdocdbUVWIXx0Hqp3gjDoWednd2Z0aaJeQmZSM5FfKWpUwkkkkx4iyVjDNxRgYn8IJctu2OMS6l4APyvf7swGPyBl9IX10doGkweKPoDAP6xlgIxlnqNF2BB4XxwNUUbEULV6GxSI2lqy34Ji67YBQct4uuAUvvXXWgD3VnKrqGZl9jSzetsR8UaAFh66r-vj7QlY-mCAGrSPHOJjO3j_3MRLcoNq9RBR_9rsi5hrrF6786JJuH-UuxSJbPj0_F3TJRQrCQaFCTfJxneqIqCTxn0wwyJnSm3xFENhWcaa3yDDjmMsKZ5opXyMcTkOMUUjEko6NuqwzWrty5zttoWK77IMs-yN9w48R4GmMfEn4kKO_a1qMu99404A9lysr-LeWJWP6_RfwAf_aCmA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode</title><source>Free E-Journal (出版社公開部分のみ)</source><creator>Santos, Anderson M. ; Vicentini, Fernando C. ; Deroco, Patrícia B. ; Rocha-Filho, Romeu C. ; Fatibello-Filho, Orlando</creator><creatorcontrib>Santos, Anderson M. ; Vicentini, Fernando C. ; Deroco, Patrícia B. ; Rocha-Filho, Romeu C. ; Fatibello-Filho, Orlando</creatorcontrib><description>Simple, fast, and inexpensive electroanalytical procedures were developed for the determination of codeine (COD) solely and paracetamol (PCT) and COD simultaneously in pharmaceutical formulations and human body fluids. The methods involve the combination of square-wave voltammetry (SWV) with a cathodically pretreated boron-doped diamond electrode and a 0.2 mol L–1 acetate buffer (pH 4.0) solution as the supporting electrolyte. Significantly low limits of detection were obtained for COD solely or PCT and COD simultaneously: 1.19 or 18 and 14 nmol L–1, respectively. The proposed SWV method was successfully applied in the simultaneous determination of PCT and COD in four samples of pharmaceutical tablets, with results similar (at 98% confidence level) to those obtained using a reference high-performance liquid chromatography (HPLC) method. Additionally, adequate results were obtained when concentrations of PCT and COD were determined in human urine or serum samples by addition-recovery. Clearly, the proposed method is an excellent option for the determination of COD solely or PCT and COD simultaneously.</description><identifier>ISSN: 0103-5053</identifier><identifier>ISSN: 1678-4790</identifier><identifier>DOI: 10.5935/0103-5053.20150203</identifier><language>eng</language><publisher>Sociedade Brasileira de Química</publisher><subject>CHEMISTRY, MULTIDISCIPLINARY</subject><ispartof>Journal of the Brazilian Chemical Society, 2015-10, Vol.26 (10), p.2159-2168</ispartof><rights>This work is licensed under a Creative Commons Attribution 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c330t-fac78684f7cd5a28094a403f4fbea349320ffc84a2e853f44f2c2de267a561a13</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids></links><search><creatorcontrib>Santos, Anderson M.</creatorcontrib><creatorcontrib>Vicentini, Fernando C.</creatorcontrib><creatorcontrib>Deroco, Patrícia B.</creatorcontrib><creatorcontrib>Rocha-Filho, Romeu C.</creatorcontrib><creatorcontrib>Fatibello-Filho, Orlando</creatorcontrib><title>Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode</title><title>Journal of the Brazilian Chemical Society</title><addtitle>J. Braz. Chem. Soc</addtitle><description>Simple, fast, and inexpensive electroanalytical procedures were developed for the determination of codeine (COD) solely and paracetamol (PCT) and COD simultaneously in pharmaceutical formulations and human body fluids. The methods involve the combination of square-wave voltammetry (SWV) with a cathodically pretreated boron-doped diamond electrode and a 0.2 mol L–1 acetate buffer (pH 4.0) solution as the supporting electrolyte. Significantly low limits of detection were obtained for COD solely or PCT and COD simultaneously: 1.19 or 18 and 14 nmol L–1, respectively. The proposed SWV method was successfully applied in the simultaneous determination of PCT and COD in four samples of pharmaceutical tablets, with results similar (at 98% confidence level) to those obtained using a reference high-performance liquid chromatography (HPLC) method. Additionally, adequate results were obtained when concentrations of PCT and COD were determined in human urine or serum samples by addition-recovery. Clearly, the proposed method is an excellent option for the determination of COD solely or PCT and COD simultaneously.</description><subject>CHEMISTRY, MULTIDISCIPLINARY</subject><issn>0103-5053</issn><issn>1678-4790</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNo9UUFOwzAQ9AEkSuEDnPyBFMeO2_QIaaFIlahUCsdocdbUVWIXx0Hqp3gjDoWednd2Z0aaJeQmZSM5FfKWpUwkkkkx4iyVjDNxRgYn8IJctu2OMS6l4APyvf7swGPyBl9IX10doGkweKPoDAP6xlgIxlnqNF2BB4XxwNUUbEULV6GxSI2lqy34Ji67YBQct4uuAUvvXXWgD3VnKrqGZl9jSzetsR8UaAFh66r-vj7QlY-mCAGrSPHOJjO3j_3MRLcoNq9RBR_9rsi5hrrF6786JJuH-UuxSJbPj0_F3TJRQrCQaFCTfJxneqIqCTxn0wwyJnSm3xFENhWcaa3yDDjmMsKZ5opXyMcTkOMUUjEko6NuqwzWrty5zttoWK77IMs-yN9w48R4GmMfEn4kKO_a1qMu99404A9lysr-LeWJWP6_RfwAf_aCmA</recordid><startdate>20151001</startdate><enddate>20151001</enddate><creator>Santos, Anderson M.</creator><creator>Vicentini, Fernando C.</creator><creator>Deroco, Patrícia B.</creator><creator>Rocha-Filho, Romeu C.</creator><creator>Fatibello-Filho, Orlando</creator><general>Sociedade Brasileira de Química</general><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope></search><sort><creationdate>20151001</creationdate><title>Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode</title><author>Santos, Anderson M. ; Vicentini, Fernando C. ; Deroco, Patrícia B. ; Rocha-Filho, Romeu C. ; Fatibello-Filho, Orlando</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c330t-fac78684f7cd5a28094a403f4fbea349320ffc84a2e853f44f2c2de267a561a13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>CHEMISTRY, MULTIDISCIPLINARY</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Santos, Anderson M.</creatorcontrib><creatorcontrib>Vicentini, Fernando C.</creatorcontrib><creatorcontrib>Deroco, Patrícia B.</creatorcontrib><creatorcontrib>Rocha-Filho, Romeu C.</creatorcontrib><creatorcontrib>Fatibello-Filho, Orlando</creatorcontrib><collection>CrossRef</collection><collection>SciELO</collection><jtitle>Journal of the Brazilian Chemical Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Santos, Anderson M.</au><au>Vicentini, Fernando C.</au><au>Deroco, Patrícia B.</au><au>Rocha-Filho, Romeu C.</au><au>Fatibello-Filho, Orlando</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode</atitle><jtitle>Journal of the Brazilian Chemical Society</jtitle><addtitle>J. Braz. Chem. Soc</addtitle><date>2015-10-01</date><risdate>2015</risdate><volume>26</volume><issue>10</issue><spage>2159</spage><epage>2168</epage><pages>2159-2168</pages><issn>0103-5053</issn><issn>1678-4790</issn><abstract>Simple, fast, and inexpensive electroanalytical procedures were developed for the determination of codeine (COD) solely and paracetamol (PCT) and COD simultaneously in pharmaceutical formulations and human body fluids. The methods involve the combination of square-wave voltammetry (SWV) with a cathodically pretreated boron-doped diamond electrode and a 0.2 mol L–1 acetate buffer (pH 4.0) solution as the supporting electrolyte. Significantly low limits of detection were obtained for COD solely or PCT and COD simultaneously: 1.19 or 18 and 14 nmol L–1, respectively. The proposed SWV method was successfully applied in the simultaneous determination of PCT and COD in four samples of pharmaceutical tablets, with results similar (at 98% confidence level) to those obtained using a reference high-performance liquid chromatography (HPLC) method. Additionally, adequate results were obtained when concentrations of PCT and COD were determined in human urine or serum samples by addition-recovery. Clearly, the proposed method is an excellent option for the determination of COD solely or PCT and COD simultaneously.</abstract><pub>Sociedade Brasileira de Química</pub><doi>10.5935/0103-5053.20150203</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0103-5053
ispartof Journal of the Brazilian Chemical Society, 2015-10, Vol.26 (10), p.2159-2168
issn 0103-5053
1678-4790
language eng
recordid cdi_scielo_journals_S0103_50532015001002159
source Free E-Journal (出版社公開部分のみ)
subjects CHEMISTRY, MULTIDISCIPLINARY
title Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T09%3A01%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Square-Wave%20Voltammetric%20Determination%20of%20Paracetamol%20and%20Codeine%20in%20Pharmaceutical%20and%20Human%20Body%20Fluid%20Samples%20Using%20a%20Cathodically%20Pretreated%20Boron-Doped%20Diamond%20Electrode&rft.jtitle=Journal%20of%20the%20Brazilian%20Chemical%20Society&rft.au=Santos,%20Anderson%20M.&rft.date=2015-10-01&rft.volume=26&rft.issue=10&rft.spage=2159&rft.epage=2168&rft.pages=2159-2168&rft.issn=0103-5053&rft_id=info:doi/10.5935/0103-5053.20150203&rft_dat=%3Cscielo_cross%3ES0103_50532015001002159%3C/scielo_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S0103_50532015001002159&rfr_iscdi=true