A LED based photometer for solid phase photometry: zinc determination in pharmaceutical preparation employing a multicommuted flow analysis approach

In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Brazilian Chemical Society 2012-08, Vol.23 (8), p.1515-1522
Hauptverfasser: Dias, Tuanne R., Reis, Boaventura F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1522
container_issue 8
container_start_page 1515
container_title Journal of the Brazilian Chemical Society
container_volume 23
creator Dias, Tuanne R.
Reis, Boaventura F.
description In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 µg L-1 Zn (3σ criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 µg per determination, respectively.
doi_str_mv 10.1590/S0103-50532012005000014
format Article
fullrecord <record><control><sourceid>scielo_cross</sourceid><recordid>TN_cdi_scielo_journals_S0103_50532012000800014</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S0103_50532012000800014</scielo_id><sourcerecordid>S0103_50532012000800014</sourcerecordid><originalsourceid>FETCH-LOGICAL-c345t-10795200d04902228af05ef69f5ec603b4655160876bcdc647ccff9ba2dea0a93</originalsourceid><addsrcrecordid>eNplUctOwzAQ9AEkyuMb8A-krJM4abhVpTykShyAc7RxbOrKiSM7EQrfwQfjtFU5sJeVdmb2MUvILYM54wXcvQGDJOLAkxhYDMAhBEvPyOwEXJBL73cAMQ-kGflZ0s36gVboZU27re1tI3vpqLKOemv0VAzYCXLjPf3WraD1RGt0i722LdXtxHMNCjn0WqChnZMdugMqm87YUbefFGkzmECwTTP0YaIy9otii2b02lPsOmdRbK_JuULj5c0xX5GPx_X76jnavD69rJabSCQp7yMGecHDlTWkBcRxvEAFXKqsUFyKDJIqzThnGSzyrBK1yNJcCKWKCuNaImCRXJH5oa8XWhpb7uzgwi6-3PtY_vkIi72PQZAfBMJZ751UZed0g24sGZTTB_4pjx9IfgEAh3xp</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A LED based photometer for solid phase photometry: zinc determination in pharmaceutical preparation employing a multicommuted flow analysis approach</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Dias, Tuanne R. ; Reis, Boaventura F.</creator><creatorcontrib>Dias, Tuanne R. ; Reis, Boaventura F.</creatorcontrib><description>In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 µg L-1 Zn (3σ criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 µg per determination, respectively.</description><identifier>ISSN: 0103-5053</identifier><identifier>ISSN: 1678-4790</identifier><identifier>DOI: 10.1590/S0103-50532012005000014</identifier><language>eng</language><publisher>Sociedade Brasileira de Química</publisher><subject>CHEMISTRY, MULTIDISCIPLINARY</subject><ispartof>Journal of the Brazilian Chemical Society, 2012-08, Vol.23 (8), p.1515-1522</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c345t-10795200d04902228af05ef69f5ec603b4655160876bcdc647ccff9ba2dea0a93</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,777,781,882,27906,27907</link.rule.ids></links><search><creatorcontrib>Dias, Tuanne R.</creatorcontrib><creatorcontrib>Reis, Boaventura F.</creatorcontrib><title>A LED based photometer for solid phase photometry: zinc determination in pharmaceutical preparation employing a multicommuted flow analysis approach</title><title>Journal of the Brazilian Chemical Society</title><addtitle>J. Braz. Chem. Soc</addtitle><description>In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 µg L-1 Zn (3σ criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 µg per determination, respectively.</description><subject>CHEMISTRY, MULTIDISCIPLINARY</subject><issn>0103-5053</issn><issn>1678-4790</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNplUctOwzAQ9AEkyuMb8A-krJM4abhVpTykShyAc7RxbOrKiSM7EQrfwQfjtFU5sJeVdmb2MUvILYM54wXcvQGDJOLAkxhYDMAhBEvPyOwEXJBL73cAMQ-kGflZ0s36gVboZU27re1tI3vpqLKOemv0VAzYCXLjPf3WraD1RGt0i722LdXtxHMNCjn0WqChnZMdugMqm87YUbefFGkzmECwTTP0YaIy9otii2b02lPsOmdRbK_JuULj5c0xX5GPx_X76jnavD69rJabSCQp7yMGecHDlTWkBcRxvEAFXKqsUFyKDJIqzThnGSzyrBK1yNJcCKWKCuNaImCRXJH5oa8XWhpb7uzgwi6-3PtY_vkIi72PQZAfBMJZ751UZed0g24sGZTTB_4pjx9IfgEAh3xp</recordid><startdate>20120801</startdate><enddate>20120801</enddate><creator>Dias, Tuanne R.</creator><creator>Reis, Boaventura F.</creator><general>Sociedade Brasileira de Química</general><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope></search><sort><creationdate>20120801</creationdate><title>A LED based photometer for solid phase photometry: zinc determination in pharmaceutical preparation employing a multicommuted flow analysis approach</title><author>Dias, Tuanne R. ; Reis, Boaventura F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c345t-10795200d04902228af05ef69f5ec603b4655160876bcdc647ccff9ba2dea0a93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>CHEMISTRY, MULTIDISCIPLINARY</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dias, Tuanne R.</creatorcontrib><creatorcontrib>Reis, Boaventura F.</creatorcontrib><collection>CrossRef</collection><collection>SciELO</collection><jtitle>Journal of the Brazilian Chemical Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dias, Tuanne R.</au><au>Reis, Boaventura F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A LED based photometer for solid phase photometry: zinc determination in pharmaceutical preparation employing a multicommuted flow analysis approach</atitle><jtitle>Journal of the Brazilian Chemical Society</jtitle><addtitle>J. Braz. Chem. Soc</addtitle><date>2012-08-01</date><risdate>2012</risdate><volume>23</volume><issue>8</issue><spage>1515</spage><epage>1522</epage><pages>1515-1522</pages><issn>0103-5053</issn><issn>1678-4790</issn><abstract>In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 µg L-1 Zn (3σ criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 µg per determination, respectively.</abstract><pub>Sociedade Brasileira de Química</pub><doi>10.1590/S0103-50532012005000014</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0103-5053
ispartof Journal of the Brazilian Chemical Society, 2012-08, Vol.23 (8), p.1515-1522
issn 0103-5053
1678-4790
language eng
recordid cdi_scielo_journals_S0103_50532012000800014
source EZB-FREE-00999 freely available EZB journals
subjects CHEMISTRY, MULTIDISCIPLINARY
title A LED based photometer for solid phase photometry: zinc determination in pharmaceutical preparation employing a multicommuted flow analysis approach
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T09%3A57%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20LED%20based%20photometer%20for%20solid%20phase%20photometry:%20zinc%20determination%20in%20pharmaceutical%20preparation%20employing%20a%20multicommuted%20flow%20analysis%20approach&rft.jtitle=Journal%20of%20the%20Brazilian%20Chemical%20Society&rft.au=Dias,%20Tuanne%20R.&rft.date=2012-08-01&rft.volume=23&rft.issue=8&rft.spage=1515&rft.epage=1522&rft.pages=1515-1522&rft.issn=0103-5053&rft_id=info:doi/10.1590/S0103-50532012005000014&rft_dat=%3Cscielo_cross%3ES0103_50532012000800014%3C/scielo_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S0103_50532012000800014&rfr_iscdi=true