Antenatal Diagnosis of Cretin Lambs by Measurement of Amniotic Fluid Thyrotropin 1

Summary Elevated TSH levels are highly reliable in predicting neonatal lamb hypo-thyroidism. However, the method is not as sensitive as serum TSH measurement, and mild hypothyroidism can exist with normal amniotic fluid thyrotropin and elevated serum TSH.

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Proceedings of the Society for Experimental Biology and Medicine 1978-01, Vol.157 (1), p.106-109
Hauptverfasser: Hollingsworth, Dorothy R., Davis, Steven L., Chopra, Inder J., Belin, Robert P., Reid, Marion C.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 109
container_issue 1
container_start_page 106
container_title Proceedings of the Society for Experimental Biology and Medicine
container_volume 157
creator Hollingsworth, Dorothy R.
Davis, Steven L.
Chopra, Inder J.
Belin, Robert P.
Reid, Marion C.
description Summary Elevated TSH levels are highly reliable in predicting neonatal lamb hypo-thyroidism. However, the method is not as sensitive as serum TSH measurement, and mild hypothyroidism can exist with normal amniotic fluid thyrotropin and elevated serum TSH.
doi_str_mv 10.3181/00379727-157-40001
format Article
fullrecord <record><control><sourceid>sage</sourceid><recordid>TN_cdi_sage_journals_10_3181_00379727_157_40001</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.3181_00379727-157-40001</sage_id><sourcerecordid>10.3181_00379727-157-40001</sourcerecordid><originalsourceid>FETCH-sage_journals_10_3181_00379727_157_400013</originalsourceid><addsrcrecordid>eNqVjk0OgjAYRBujifhzAVe9QPUrFZElQY0L3Rj2TdGCNdCatiy8vWD0AK4mmXmTPIQWFJaMbukKgMVJHMaERjFZAwAdoIBGLCJskyRDFPQA6Ykxmjj36IgNhBCgS6q91MKLGu-UqLRxymFT4sxKrzQ-iaZwuHjhsxSutbKR2vdz2mhlvLriQ92qG87vL2u8Nc_uQmdoVIrayfk3p2h12OfZkThRSf4wrdVdzSnwXp3_1Hmnzj_q7P_HG7CSSaI</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Antenatal Diagnosis of Cretin Lambs by Measurement of Amniotic Fluid Thyrotropin 1</title><source>Alma/SFX Local Collection</source><creator>Hollingsworth, Dorothy R. ; Davis, Steven L. ; Chopra, Inder J. ; Belin, Robert P. ; Reid, Marion C.</creator><creatorcontrib>Hollingsworth, Dorothy R. ; Davis, Steven L. ; Chopra, Inder J. ; Belin, Robert P. ; Reid, Marion C.</creatorcontrib><description>Summary Elevated TSH levels are highly reliable in predicting neonatal lamb hypo-thyroidism. However, the method is not as sensitive as serum TSH measurement, and mild hypothyroidism can exist with normal amniotic fluid thyrotropin and elevated serum TSH.</description><identifier>ISSN: 0037-9727</identifier><identifier>EISSN: 1535-3699</identifier><identifier>DOI: 10.3181/00379727-157-40001</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><ispartof>Proceedings of the Society for Experimental Biology and Medicine, 1978-01, Vol.157 (1), p.106-109</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Hollingsworth, Dorothy R.</creatorcontrib><creatorcontrib>Davis, Steven L.</creatorcontrib><creatorcontrib>Chopra, Inder J.</creatorcontrib><creatorcontrib>Belin, Robert P.</creatorcontrib><creatorcontrib>Reid, Marion C.</creatorcontrib><title>Antenatal Diagnosis of Cretin Lambs by Measurement of Amniotic Fluid Thyrotropin 1</title><title>Proceedings of the Society for Experimental Biology and Medicine</title><description>Summary Elevated TSH levels are highly reliable in predicting neonatal lamb hypo-thyroidism. However, the method is not as sensitive as serum TSH measurement, and mild hypothyroidism can exist with normal amniotic fluid thyrotropin and elevated serum TSH.</description><issn>0037-9727</issn><issn>1535-3699</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1978</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqVjk0OgjAYRBujifhzAVe9QPUrFZElQY0L3Rj2TdGCNdCatiy8vWD0AK4mmXmTPIQWFJaMbukKgMVJHMaERjFZAwAdoIBGLCJskyRDFPQA6Ykxmjj36IgNhBCgS6q91MKLGu-UqLRxymFT4sxKrzQ-iaZwuHjhsxSutbKR2vdz2mhlvLriQ92qG87vL2u8Nc_uQmdoVIrayfk3p2h12OfZkThRSf4wrdVdzSnwXp3_1Hmnzj_q7P_HG7CSSaI</recordid><startdate>197801</startdate><enddate>197801</enddate><creator>Hollingsworth, Dorothy R.</creator><creator>Davis, Steven L.</creator><creator>Chopra, Inder J.</creator><creator>Belin, Robert P.</creator><creator>Reid, Marion C.</creator><general>SAGE Publications</general><scope/></search><sort><creationdate>197801</creationdate><title>Antenatal Diagnosis of Cretin Lambs by Measurement of Amniotic Fluid Thyrotropin 1</title><author>Hollingsworth, Dorothy R. ; Davis, Steven L. ; Chopra, Inder J. ; Belin, Robert P. ; Reid, Marion C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-sage_journals_10_3181_00379727_157_400013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1978</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hollingsworth, Dorothy R.</creatorcontrib><creatorcontrib>Davis, Steven L.</creatorcontrib><creatorcontrib>Chopra, Inder J.</creatorcontrib><creatorcontrib>Belin, Robert P.</creatorcontrib><creatorcontrib>Reid, Marion C.</creatorcontrib><jtitle>Proceedings of the Society for Experimental Biology and Medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hollingsworth, Dorothy R.</au><au>Davis, Steven L.</au><au>Chopra, Inder J.</au><au>Belin, Robert P.</au><au>Reid, Marion C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Antenatal Diagnosis of Cretin Lambs by Measurement of Amniotic Fluid Thyrotropin 1</atitle><jtitle>Proceedings of the Society for Experimental Biology and Medicine</jtitle><date>1978-01</date><risdate>1978</risdate><volume>157</volume><issue>1</issue><spage>106</spage><epage>109</epage><pages>106-109</pages><issn>0037-9727</issn><eissn>1535-3699</eissn><abstract>Summary Elevated TSH levels are highly reliable in predicting neonatal lamb hypo-thyroidism. However, the method is not as sensitive as serum TSH measurement, and mild hypothyroidism can exist with normal amniotic fluid thyrotropin and elevated serum TSH.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.3181/00379727-157-40001</doi></addata></record>
fulltext fulltext
identifier ISSN: 0037-9727
ispartof Proceedings of the Society for Experimental Biology and Medicine, 1978-01, Vol.157 (1), p.106-109
issn 0037-9727
1535-3699
language eng
recordid cdi_sage_journals_10_3181_00379727_157_40001
source Alma/SFX Local Collection
title Antenatal Diagnosis of Cretin Lambs by Measurement of Amniotic Fluid Thyrotropin 1
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T20%3A39%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Antenatal%20Diagnosis%20of%20Cretin%20Lambs%20by%20Measurement%20of%20Amniotic%20Fluid%20Thyrotropin%201&rft.jtitle=Proceedings%20of%20the%20Society%20for%20Experimental%20Biology%20and%20Medicine&rft.au=Hollingsworth,%20Dorothy%20R.&rft.date=1978-01&rft.volume=157&rft.issue=1&rft.spage=106&rft.epage=109&rft.pages=106-109&rft.issn=0037-9727&rft.eissn=1535-3699&rft_id=info:doi/10.3181/00379727-157-40001&rft_dat=%3Csage%3E10.3181_00379727-157-40001%3C/sage%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sage_id=10.3181_00379727-157-40001&rfr_iscdi=true