Changes in pupillometry associated with dissipated energy during phacoemulsification
Purpose: To investigate the effect of ultrasound level during phacoemulsification on pupil dynamics. Methods: Comparative retrospective study on patients who underwent routine cataract surgery at the Royal Liverpool University Hospital. Clinical parameters, anterior chamber measurements, axial lengt...
Gespeichert in:
Veröffentlicht in: | European journal of ophthalmology 2021-11, Vol.31 (6), p.2962-2968, Article 1120672120984377 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2968 |
---|---|
container_issue | 6 |
container_start_page | 2962 |
container_title | European journal of ophthalmology |
container_volume | 31 |
creator | Coco, Giulia Cremonesi, Pierluca Menassa, Nardine Pagano, Luca Gadhvi, Kunal A Semeraro, Francesco Kaye, Stephen B Romano, Vito |
description | Purpose:
To investigate the effect of ultrasound level during phacoemulsification on pupil dynamics.
Methods:
Comparative retrospective study on patients who underwent routine cataract surgery at the Royal Liverpool University Hospital. Clinical parameters, anterior chamber measurements, axial length, surgeon grade, time of surgery, level of ultrasound used (cumulative dissipated energy, CDE), intra- and post-operative complications were collected. Pupil diameters were collected before and 4 ± 1 weeks after surgery in static scotopic, mesopic, photopic pupil conditions. Also, pupil dynamic measurements after luminous stimulus were recorded. Changes in static pupil diameters, relative dilation at 3.5 s after luminous stimulus, and time to reach 75% and 95% of maximum dilation were measured.
Results:
Forty-eight eyes of 24 patients (13 males) were included with a mean age of 73.1 ± 14.6 years. Mean CDE value was 18.11 ± 10.56. Mean scotopic pupil diameters decreased by 0.24 ± 0.48 mm (p = 0.021) in the operated eye. Significant correlation was found between reduction in scotopic pupil diameter and CDE (p = 0.05). A generalized linear model confirmed that the level of CDE was significantly associated with reduction in scotopic pupil diameter (p = 0.026). Patients who underwent surgeries with lower CDE (0 |
doi_str_mv | 10.1177/1120672120984377 |
format | Article |
fullrecord | <record><control><sourceid>sage_pubme</sourceid><recordid>TN_cdi_sage_journals_10_1177_1120672120984377</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1120672120984377</sage_id><sourcerecordid>10.1177_1120672120984377</sourcerecordid><originalsourceid>FETCH-LOGICAL-c337t-e1794bf309259a0b58f0b5a26eeb098cf9491b7759919671ca41b89c700eee233</originalsourceid><addsrcrecordid>eNqNkE1PwzAMhiMEYmNw54R6R4V8tE1zRBVf0iQu41ylqdtl6pIqaTXt35OtsAMSEhfbkZ_XsV-Ebgl-IITzR0IozjgNUeQJ4_wMzQmnSZxhkp2HOjTiQ3-GrrzfYBy4hF6iGWOM0zQRc7Qq1tK04CNton7sddfZLQxuH0nvrdJygDra6WEd1dp73R_fYMC1-6genTZt1K-lsrAdO68breSgrblGF43sPNx85wX6fHleFW_x8uP1vXhaxir8P8RAuEiqhmFBUyFxleZNCJJmAFU4SDUiEaTiPBWCiIwTJRNS5UJxjAGAMrZAeJqrnPXeQVP2Tm-l25cElweDyt8GBcndJOnHagv1SfDjSADyCdhBZRuvNBgFJwzjMI7nmLFQYVLo4XhwYUczBOn9_6WBjifayxbKjR2dCV79vfkXwAKPEA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Changes in pupillometry associated with dissipated energy during phacoemulsification</title><source>Access via SAGE</source><source>MEDLINE</source><source>Web of Science - Science Citation Index Expanded - 2021<img src="https://exlibris-pub.s3.amazonaws.com/fromwos-v2.jpg" /></source><creator>Coco, Giulia ; Cremonesi, Pierluca ; Menassa, Nardine ; Pagano, Luca ; Gadhvi, Kunal A ; Semeraro, Francesco ; Kaye, Stephen B ; Romano, Vito</creator><creatorcontrib>Coco, Giulia ; Cremonesi, Pierluca ; Menassa, Nardine ; Pagano, Luca ; Gadhvi, Kunal A ; Semeraro, Francesco ; Kaye, Stephen B ; Romano, Vito</creatorcontrib><description>Purpose:
To investigate the effect of ultrasound level during phacoemulsification on pupil dynamics.
Methods:
Comparative retrospective study on patients who underwent routine cataract surgery at the Royal Liverpool University Hospital. Clinical parameters, anterior chamber measurements, axial length, surgeon grade, time of surgery, level of ultrasound used (cumulative dissipated energy, CDE), intra- and post-operative complications were collected. Pupil diameters were collected before and 4 ± 1 weeks after surgery in static scotopic, mesopic, photopic pupil conditions. Also, pupil dynamic measurements after luminous stimulus were recorded. Changes in static pupil diameters, relative dilation at 3.5 s after luminous stimulus, and time to reach 75% and 95% of maximum dilation were measured.
Results:
Forty-eight eyes of 24 patients (13 males) were included with a mean age of 73.1 ± 14.6 years. Mean CDE value was 18.11 ± 10.56. Mean scotopic pupil diameters decreased by 0.24 ± 0.48 mm (p = 0.021) in the operated eye. Significant correlation was found between reduction in scotopic pupil diameter and CDE (p = 0.05). A generalized linear model confirmed that the level of CDE was significantly associated with reduction in scotopic pupil diameter (p = 0.026). Patients who underwent surgeries with lower CDE (0 < CDE ⩽ 10 and 10 < CDE ⩽ 20) did not experience significant changes in scotopic pupil diameter after surgery (p = 0.28 and p = 0.79, respectively) as opposed to those with higher CDE (CDE > 20; p = 0.03).
Conclusion:
Phacoemulsification cataract surgery and the cumulative dissipated energy may be associated with changes in pupil behaviour.</description><identifier>ISSN: 1120-6721</identifier><identifier>EISSN: 1724-6016</identifier><identifier>DOI: 10.1177/1120672120984377</identifier><identifier>PMID: 33372549</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Aged ; Aged, 80 and over ; Cataract Extraction ; Humans ; Lens, Crystalline ; Life Sciences & Biomedicine ; Male ; Middle Aged ; Ophthalmology ; Phacoemulsification ; Pupil ; Retrospective Studies ; Science & Technology</subject><ispartof>European journal of ophthalmology, 2021-11, Vol.31 (6), p.2962-2968, Article 1120672120984377</ispartof><rights>The Author(s) 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>true</woscitedreferencessubscribed><woscitedreferencescount>3</woscitedreferencescount><woscitedreferencesoriginalsourcerecordid>wos000677803300001</woscitedreferencesoriginalsourcerecordid><citedby>FETCH-LOGICAL-c337t-e1794bf309259a0b58f0b5a26eeb098cf9491b7759919671ca41b89c700eee233</citedby><cites>FETCH-LOGICAL-c337t-e1794bf309259a0b58f0b5a26eeb098cf9491b7759919671ca41b89c700eee233</cites><orcidid>0000-0002-2410-6366 ; 0000-0002-2275-4917 ; 0000-0001-8534-6817 ; 0000-0002-5148-7643</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1120672120984377$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1120672120984377$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>315,782,786,21826,27931,27932,39265,43628,43629</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33372549$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Coco, Giulia</creatorcontrib><creatorcontrib>Cremonesi, Pierluca</creatorcontrib><creatorcontrib>Menassa, Nardine</creatorcontrib><creatorcontrib>Pagano, Luca</creatorcontrib><creatorcontrib>Gadhvi, Kunal A</creatorcontrib><creatorcontrib>Semeraro, Francesco</creatorcontrib><creatorcontrib>Kaye, Stephen B</creatorcontrib><creatorcontrib>Romano, Vito</creatorcontrib><title>Changes in pupillometry associated with dissipated energy during phacoemulsification</title><title>European journal of ophthalmology</title><addtitle>EUR J OPHTHALMOL</addtitle><addtitle>Eur J Ophthalmol</addtitle><description>Purpose:
To investigate the effect of ultrasound level during phacoemulsification on pupil dynamics.
Methods:
Comparative retrospective study on patients who underwent routine cataract surgery at the Royal Liverpool University Hospital. Clinical parameters, anterior chamber measurements, axial length, surgeon grade, time of surgery, level of ultrasound used (cumulative dissipated energy, CDE), intra- and post-operative complications were collected. Pupil diameters were collected before and 4 ± 1 weeks after surgery in static scotopic, mesopic, photopic pupil conditions. Also, pupil dynamic measurements after luminous stimulus were recorded. Changes in static pupil diameters, relative dilation at 3.5 s after luminous stimulus, and time to reach 75% and 95% of maximum dilation were measured.
Results:
Forty-eight eyes of 24 patients (13 males) were included with a mean age of 73.1 ± 14.6 years. Mean CDE value was 18.11 ± 10.56. Mean scotopic pupil diameters decreased by 0.24 ± 0.48 mm (p = 0.021) in the operated eye. Significant correlation was found between reduction in scotopic pupil diameter and CDE (p = 0.05). A generalized linear model confirmed that the level of CDE was significantly associated with reduction in scotopic pupil diameter (p = 0.026). Patients who underwent surgeries with lower CDE (0 < CDE ⩽ 10 and 10 < CDE ⩽ 20) did not experience significant changes in scotopic pupil diameter after surgery (p = 0.28 and p = 0.79, respectively) as opposed to those with higher CDE (CDE > 20; p = 0.03).
Conclusion:
Phacoemulsification cataract surgery and the cumulative dissipated energy may be associated with changes in pupil behaviour.</description><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Cataract Extraction</subject><subject>Humans</subject><subject>Lens, Crystalline</subject><subject>Life Sciences & Biomedicine</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Ophthalmology</subject><subject>Phacoemulsification</subject><subject>Pupil</subject><subject>Retrospective Studies</subject><subject>Science & Technology</subject><issn>1120-6721</issn><issn>1724-6016</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>HGBXW</sourceid><sourceid>EIF</sourceid><recordid>eNqNkE1PwzAMhiMEYmNw54R6R4V8tE1zRBVf0iQu41ylqdtl6pIqaTXt35OtsAMSEhfbkZ_XsV-Ebgl-IITzR0IozjgNUeQJ4_wMzQmnSZxhkp2HOjTiQ3-GrrzfYBy4hF6iGWOM0zQRc7Qq1tK04CNton7sddfZLQxuH0nvrdJygDra6WEd1dp73R_fYMC1-6genTZt1K-lsrAdO68breSgrblGF43sPNx85wX6fHleFW_x8uP1vXhaxir8P8RAuEiqhmFBUyFxleZNCJJmAFU4SDUiEaTiPBWCiIwTJRNS5UJxjAGAMrZAeJqrnPXeQVP2Tm-l25cElweDyt8GBcndJOnHagv1SfDjSADyCdhBZRuvNBgFJwzjMI7nmLFQYVLo4XhwYUczBOn9_6WBjifayxbKjR2dCV79vfkXwAKPEA</recordid><startdate>202111</startdate><enddate>202111</enddate><creator>Coco, Giulia</creator><creator>Cremonesi, Pierluca</creator><creator>Menassa, Nardine</creator><creator>Pagano, Luca</creator><creator>Gadhvi, Kunal A</creator><creator>Semeraro, Francesco</creator><creator>Kaye, Stephen B</creator><creator>Romano, Vito</creator><general>SAGE Publications</general><general>Sage</general><scope>BLEPL</scope><scope>DTL</scope><scope>HGBXW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-2410-6366</orcidid><orcidid>https://orcid.org/0000-0002-2275-4917</orcidid><orcidid>https://orcid.org/0000-0001-8534-6817</orcidid><orcidid>https://orcid.org/0000-0002-5148-7643</orcidid></search><sort><creationdate>202111</creationdate><title>Changes in pupillometry associated with dissipated energy during phacoemulsification</title><author>Coco, Giulia ; Cremonesi, Pierluca ; Menassa, Nardine ; Pagano, Luca ; Gadhvi, Kunal A ; Semeraro, Francesco ; Kaye, Stephen B ; Romano, Vito</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c337t-e1794bf309259a0b58f0b5a26eeb098cf9491b7759919671ca41b89c700eee233</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Cataract Extraction</topic><topic>Humans</topic><topic>Lens, Crystalline</topic><topic>Life Sciences & Biomedicine</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Ophthalmology</topic><topic>Phacoemulsification</topic><topic>Pupil</topic><topic>Retrospective Studies</topic><topic>Science & Technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Coco, Giulia</creatorcontrib><creatorcontrib>Cremonesi, Pierluca</creatorcontrib><creatorcontrib>Menassa, Nardine</creatorcontrib><creatorcontrib>Pagano, Luca</creatorcontrib><creatorcontrib>Gadhvi, Kunal A</creatorcontrib><creatorcontrib>Semeraro, Francesco</creatorcontrib><creatorcontrib>Kaye, Stephen B</creatorcontrib><creatorcontrib>Romano, Vito</creatorcontrib><collection>Web of Science Core Collection</collection><collection>Science Citation Index Expanded</collection><collection>Web of Science - Science Citation Index Expanded - 2021</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>European journal of ophthalmology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Coco, Giulia</au><au>Cremonesi, Pierluca</au><au>Menassa, Nardine</au><au>Pagano, Luca</au><au>Gadhvi, Kunal A</au><au>Semeraro, Francesco</au><au>Kaye, Stephen B</au><au>Romano, Vito</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Changes in pupillometry associated with dissipated energy during phacoemulsification</atitle><jtitle>European journal of ophthalmology</jtitle><stitle>EUR J OPHTHALMOL</stitle><addtitle>Eur J Ophthalmol</addtitle><date>2021-11</date><risdate>2021</risdate><volume>31</volume><issue>6</issue><spage>2962</spage><epage>2968</epage><pages>2962-2968</pages><artnum>1120672120984377</artnum><issn>1120-6721</issn><eissn>1724-6016</eissn><abstract>Purpose:
To investigate the effect of ultrasound level during phacoemulsification on pupil dynamics.
Methods:
Comparative retrospective study on patients who underwent routine cataract surgery at the Royal Liverpool University Hospital. Clinical parameters, anterior chamber measurements, axial length, surgeon grade, time of surgery, level of ultrasound used (cumulative dissipated energy, CDE), intra- and post-operative complications were collected. Pupil diameters were collected before and 4 ± 1 weeks after surgery in static scotopic, mesopic, photopic pupil conditions. Also, pupil dynamic measurements after luminous stimulus were recorded. Changes in static pupil diameters, relative dilation at 3.5 s after luminous stimulus, and time to reach 75% and 95% of maximum dilation were measured.
Results:
Forty-eight eyes of 24 patients (13 males) were included with a mean age of 73.1 ± 14.6 years. Mean CDE value was 18.11 ± 10.56. Mean scotopic pupil diameters decreased by 0.24 ± 0.48 mm (p = 0.021) in the operated eye. Significant correlation was found between reduction in scotopic pupil diameter and CDE (p = 0.05). A generalized linear model confirmed that the level of CDE was significantly associated with reduction in scotopic pupil diameter (p = 0.026). Patients who underwent surgeries with lower CDE (0 < CDE ⩽ 10 and 10 < CDE ⩽ 20) did not experience significant changes in scotopic pupil diameter after surgery (p = 0.28 and p = 0.79, respectively) as opposed to those with higher CDE (CDE > 20; p = 0.03).
Conclusion:
Phacoemulsification cataract surgery and the cumulative dissipated energy may be associated with changes in pupil behaviour.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>33372549</pmid><doi>10.1177/1120672120984377</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-2410-6366</orcidid><orcidid>https://orcid.org/0000-0002-2275-4917</orcidid><orcidid>https://orcid.org/0000-0001-8534-6817</orcidid><orcidid>https://orcid.org/0000-0002-5148-7643</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1120-6721 |
ispartof | European journal of ophthalmology, 2021-11, Vol.31 (6), p.2962-2968, Article 1120672120984377 |
issn | 1120-6721 1724-6016 |
language | eng |
recordid | cdi_sage_journals_10_1177_1120672120984377 |
source | Access via SAGE; MEDLINE; Web of Science - Science Citation Index Expanded - 2021<img src="https://exlibris-pub.s3.amazonaws.com/fromwos-v2.jpg" /> |
subjects | Aged Aged, 80 and over Cataract Extraction Humans Lens, Crystalline Life Sciences & Biomedicine Male Middle Aged Ophthalmology Phacoemulsification Pupil Retrospective Studies Science & Technology |
title | Changes in pupillometry associated with dissipated energy during phacoemulsification |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T01%3A54%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sage_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Changes%20in%20pupillometry%20associated%20with%20dissipated%20energy%20during%20phacoemulsification&rft.jtitle=European%20journal%20of%20ophthalmology&rft.au=Coco,%20Giulia&rft.date=2021-11&rft.volume=31&rft.issue=6&rft.spage=2962&rft.epage=2968&rft.pages=2962-2968&rft.artnum=1120672120984377&rft.issn=1120-6721&rft.eissn=1724-6016&rft_id=info:doi/10.1177/1120672120984377&rft_dat=%3Csage_pubme%3E10.1177_1120672120984377%3C/sage_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/33372549&rft_sage_id=10.1177_1120672120984377&rfr_iscdi=true |