Correlation between spinal column length and the spread of subarachnoid hyperbaric bupivacaine in the term parturient : original research

Background : Anaesthetists frequently tailor the subarachnoid local anaesthetic dosage according to parturient height to achieve sensory blockade up to the T4 dermatome for lower segment Caesarean sections (LSCSs). Studies that have been conducted have demonstrated that height does not affect the sp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Southern African journal of anaesthesia and analgesia 2010-05, Vol.16 (3), p.30-33
Hauptverfasser: Nadia, M.N., Raha, A.R., Jaafar, M.Z., Muhd Helmi, A., Azmil Farid, Z., Wan Rahiza, W.M., Azarinah, I., Muhammad, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 33
container_issue 3
container_start_page 30
container_title Southern African journal of anaesthesia and analgesia
container_volume 16
creator Nadia, M.N.
Raha, A.R.
Jaafar, M.Z.
Muhd Helmi, A.
Azmil Farid, Z.
Wan Rahiza, W.M.
Azarinah, I.
Muhammad, M.
description Background : Anaesthetists frequently tailor the subarachnoid local anaesthetic dosage according to parturient height to achieve sensory blockade up to the T4 dermatome for lower segment Caesarean sections (LSCSs). Studies that have been conducted have demonstrated that height does not affect the spread of subarachnoid hyperbaric bupivacaine. This study aimed to find the correlation between the spinal column length of term parturients and the highest level of sensory blockade after spinal anaesthesia. Methods : The authors studied 60 singleton term parturients of American Society of Anesthesiologists (ASA) physical status I or II scheduled for elective LSCSs. The length of the spinal column was taken as an average of three measurements from the C7 spinous process to the sacral hiatus in a sitting upright and facing forward position. Spinal anaesthesia was given by administering 1.8 ml of 0.5% hyperbaric bupivacaine and 25 g fentanyl through the L3/L4 or L4/L5 intervertebral space. The level of sensory blockade was assessed using pin-prick testing for pain sensation. Linear regression analysis was used to analyse the correlation; R < 0.25 indicates no correlation with the level of significance being < 0.05. Results : The spinal column lengths measured were between 42.2 cm and 85.8 cm (median : 58.5 cm). Spinal anaesthesia given was adequate for all patients, with the highest levels of anaesthesia ranging from T8 to T2 with sensory levels between T6 and T4. The parturients' spinal column length showed no correlation with the highest level of sensory blockade achieved, namely R = 0.11. Conclusions : The study found no correlation between the parturients' spinal column length and the highest level of sensory blockade achieved.
format Article
fullrecord <record><control><sourceid>sabinet</sourceid><recordid>TN_cdi_sabinet_saepub_10520_EJC73769</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sabinet_id>10520/EJC73769</sabinet_id><sourcerecordid>10520/EJC73769</sourcerecordid><originalsourceid>FETCH-sabinet_saepub_10520_EJC737693</originalsourceid><addsrcrecordid>eNqNTU1LAzEQDaJg0f6HOXgtZLOtq16Xinj2vkyy0yaSTsIkUfwJ_muXIp49vfd4XxdqZYzRm64b-ss__tBdq3Up71rrrt-andmu1PeYRChiDYnBUv0kYig5MEZwKbYTQyQ-Vg_IM1RPiymEM6QDlGZR0HlOYQb_lUkWHRzYlsMHOgxMEPhcqiQnyCi1SSCu8ARJwvH8IlQIxflbdXXAWGj9izfq7nn_Nr5sCtplqU4FKTc7dXpn9LR_HYd-uH_s_xn7ATTjVg8</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Correlation between spinal column length and the spread of subarachnoid hyperbaric bupivacaine in the term parturient : original research</title><source>Taylor &amp; Francis Open Access</source><source>Sabinet African Journals Open Access Collection</source><creator>Nadia, M.N. ; Raha, A.R. ; Jaafar, M.Z. ; Muhd Helmi, A. ; Azmil Farid, Z. ; Wan Rahiza, W.M. ; Azarinah, I. ; Muhammad, M.</creator><creatorcontrib>Nadia, M.N. ; Raha, A.R. ; Jaafar, M.Z. ; Muhd Helmi, A. ; Azmil Farid, Z. ; Wan Rahiza, W.M. ; Azarinah, I. ; Muhammad, M.</creatorcontrib><description>Background : Anaesthetists frequently tailor the subarachnoid local anaesthetic dosage according to parturient height to achieve sensory blockade up to the T4 dermatome for lower segment Caesarean sections (LSCSs). Studies that have been conducted have demonstrated that height does not affect the spread of subarachnoid hyperbaric bupivacaine. This study aimed to find the correlation between the spinal column length of term parturients and the highest level of sensory blockade after spinal anaesthesia. Methods : The authors studied 60 singleton term parturients of American Society of Anesthesiologists (ASA) physical status I or II scheduled for elective LSCSs. The length of the spinal column was taken as an average of three measurements from the C7 spinous process to the sacral hiatus in a sitting upright and facing forward position. Spinal anaesthesia was given by administering 1.8 ml of 0.5% hyperbaric bupivacaine and 25 g fentanyl through the L3/L4 or L4/L5 intervertebral space. The level of sensory blockade was assessed using pin-prick testing for pain sensation. Linear regression analysis was used to analyse the correlation; R &lt; 0.25 indicates no correlation with the level of significance being &lt; 0.05. Results : The spinal column lengths measured were between 42.2 cm and 85.8 cm (median : 58.5 cm). Spinal anaesthesia given was adequate for all patients, with the highest levels of anaesthesia ranging from T8 to T2 with sensory levels between T6 and T4. The parturients' spinal column length showed no correlation with the highest level of sensory blockade achieved, namely R = 0.11. Conclusions : The study found no correlation between the parturients' spinal column length and the highest level of sensory blockade achieved.</description><identifier>ISSN: 2220-1181</identifier><identifier>EISSN: 2220-1173</identifier><language>eng</language><publisher>Medpharm Publications</publisher><subject>Hyperbaric bupivacaine ; Parturients; lower segment Caesarean section (LSCS) ; Spinal anaesthesia ; Spinal column ; Universiti Kebangsaan Malaysia</subject><ispartof>Southern African journal of anaesthesia and analgesia, 2010-05, Vol.16 (3), p.30-33</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,39221</link.rule.ids></links><search><creatorcontrib>Nadia, M.N.</creatorcontrib><creatorcontrib>Raha, A.R.</creatorcontrib><creatorcontrib>Jaafar, M.Z.</creatorcontrib><creatorcontrib>Muhd Helmi, A.</creatorcontrib><creatorcontrib>Azmil Farid, Z.</creatorcontrib><creatorcontrib>Wan Rahiza, W.M.</creatorcontrib><creatorcontrib>Azarinah, I.</creatorcontrib><creatorcontrib>Muhammad, M.</creatorcontrib><title>Correlation between spinal column length and the spread of subarachnoid hyperbaric bupivacaine in the term parturient : original research</title><title>Southern African journal of anaesthesia and analgesia</title><description>Background : Anaesthetists frequently tailor the subarachnoid local anaesthetic dosage according to parturient height to achieve sensory blockade up to the T4 dermatome for lower segment Caesarean sections (LSCSs). Studies that have been conducted have demonstrated that height does not affect the spread of subarachnoid hyperbaric bupivacaine. This study aimed to find the correlation between the spinal column length of term parturients and the highest level of sensory blockade after spinal anaesthesia. Methods : The authors studied 60 singleton term parturients of American Society of Anesthesiologists (ASA) physical status I or II scheduled for elective LSCSs. The length of the spinal column was taken as an average of three measurements from the C7 spinous process to the sacral hiatus in a sitting upright and facing forward position. Spinal anaesthesia was given by administering 1.8 ml of 0.5% hyperbaric bupivacaine and 25 g fentanyl through the L3/L4 or L4/L5 intervertebral space. The level of sensory blockade was assessed using pin-prick testing for pain sensation. Linear regression analysis was used to analyse the correlation; R &lt; 0.25 indicates no correlation with the level of significance being &lt; 0.05. Results : The spinal column lengths measured were between 42.2 cm and 85.8 cm (median : 58.5 cm). Spinal anaesthesia given was adequate for all patients, with the highest levels of anaesthesia ranging from T8 to T2 with sensory levels between T6 and T4. The parturients' spinal column length showed no correlation with the highest level of sensory blockade achieved, namely R = 0.11. Conclusions : The study found no correlation between the parturients' spinal column length and the highest level of sensory blockade achieved.</description><subject>Hyperbaric bupivacaine</subject><subject>Parturients; lower segment Caesarean section (LSCS)</subject><subject>Spinal anaesthesia</subject><subject>Spinal column</subject><subject>Universiti Kebangsaan Malaysia</subject><issn>2220-1181</issn><issn>2220-1173</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>JRA</sourceid><recordid>eNqNTU1LAzEQDaJg0f6HOXgtZLOtq16Xinj2vkyy0yaSTsIkUfwJ_muXIp49vfd4XxdqZYzRm64b-ss__tBdq3Up71rrrt-andmu1PeYRChiDYnBUv0kYig5MEZwKbYTQyQ-Vg_IM1RPiymEM6QDlGZR0HlOYQb_lUkWHRzYlsMHOgxMEPhcqiQnyCi1SSCu8ARJwvH8IlQIxflbdXXAWGj9izfq7nn_Nr5sCtplqU4FKTc7dXpn9LR_HYd-uH_s_xn7ATTjVg8</recordid><startdate>20100501</startdate><enddate>20100501</enddate><creator>Nadia, M.N.</creator><creator>Raha, A.R.</creator><creator>Jaafar, M.Z.</creator><creator>Muhd Helmi, A.</creator><creator>Azmil Farid, Z.</creator><creator>Wan Rahiza, W.M.</creator><creator>Azarinah, I.</creator><creator>Muhammad, M.</creator><general>Medpharm Publications</general><scope>AEIZH</scope><scope>JRA</scope></search><sort><creationdate>20100501</creationdate><title>Correlation between spinal column length and the spread of subarachnoid hyperbaric bupivacaine in the term parturient : original research</title><author>Nadia, M.N. ; Raha, A.R. ; Jaafar, M.Z. ; Muhd Helmi, A. ; Azmil Farid, Z. ; Wan Rahiza, W.M. ; Azarinah, I. ; Muhammad, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-sabinet_saepub_10520_EJC737693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Hyperbaric bupivacaine</topic><topic>Parturients; lower segment Caesarean section (LSCS)</topic><topic>Spinal anaesthesia</topic><topic>Spinal column</topic><topic>Universiti Kebangsaan Malaysia</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nadia, M.N.</creatorcontrib><creatorcontrib>Raha, A.R.</creatorcontrib><creatorcontrib>Jaafar, M.Z.</creatorcontrib><creatorcontrib>Muhd Helmi, A.</creatorcontrib><creatorcontrib>Azmil Farid, Z.</creatorcontrib><creatorcontrib>Wan Rahiza, W.M.</creatorcontrib><creatorcontrib>Azarinah, I.</creatorcontrib><creatorcontrib>Muhammad, M.</creatorcontrib><collection>Sabinet:Open Access</collection><collection>Sabinet African Journals Open Access Collection</collection><jtitle>Southern African journal of anaesthesia and analgesia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nadia, M.N.</au><au>Raha, A.R.</au><au>Jaafar, M.Z.</au><au>Muhd Helmi, A.</au><au>Azmil Farid, Z.</au><au>Wan Rahiza, W.M.</au><au>Azarinah, I.</au><au>Muhammad, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Correlation between spinal column length and the spread of subarachnoid hyperbaric bupivacaine in the term parturient : original research</atitle><jtitle>Southern African journal of anaesthesia and analgesia</jtitle><date>2010-05-01</date><risdate>2010</risdate><volume>16</volume><issue>3</issue><spage>30</spage><epage>33</epage><pages>30-33</pages><issn>2220-1181</issn><eissn>2220-1173</eissn><abstract>Background : Anaesthetists frequently tailor the subarachnoid local anaesthetic dosage according to parturient height to achieve sensory blockade up to the T4 dermatome for lower segment Caesarean sections (LSCSs). Studies that have been conducted have demonstrated that height does not affect the spread of subarachnoid hyperbaric bupivacaine. This study aimed to find the correlation between the spinal column length of term parturients and the highest level of sensory blockade after spinal anaesthesia. Methods : The authors studied 60 singleton term parturients of American Society of Anesthesiologists (ASA) physical status I or II scheduled for elective LSCSs. The length of the spinal column was taken as an average of three measurements from the C7 spinous process to the sacral hiatus in a sitting upright and facing forward position. Spinal anaesthesia was given by administering 1.8 ml of 0.5% hyperbaric bupivacaine and 25 g fentanyl through the L3/L4 or L4/L5 intervertebral space. The level of sensory blockade was assessed using pin-prick testing for pain sensation. Linear regression analysis was used to analyse the correlation; R &lt; 0.25 indicates no correlation with the level of significance being &lt; 0.05. Results : The spinal column lengths measured were between 42.2 cm and 85.8 cm (median : 58.5 cm). Spinal anaesthesia given was adequate for all patients, with the highest levels of anaesthesia ranging from T8 to T2 with sensory levels between T6 and T4. The parturients' spinal column length showed no correlation with the highest level of sensory blockade achieved, namely R = 0.11. Conclusions : The study found no correlation between the parturients' spinal column length and the highest level of sensory blockade achieved.</abstract><pub>Medpharm Publications</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2220-1181
ispartof Southern African journal of anaesthesia and analgesia, 2010-05, Vol.16 (3), p.30-33
issn 2220-1181
2220-1173
language eng
recordid cdi_sabinet_saepub_10520_EJC73769
source Taylor & Francis Open Access; Sabinet African Journals Open Access Collection
subjects Hyperbaric bupivacaine
Parturients
lower segment Caesarean section (LSCS)
Spinal anaesthesia
Spinal column
Universiti Kebangsaan Malaysia
title Correlation between spinal column length and the spread of subarachnoid hyperbaric bupivacaine in the term parturient : original research
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T20%3A33%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-sabinet&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Correlation%20between%20spinal%20column%20length%20and%20the%20spread%20of%20subarachnoid%20hyperbaric%20bupivacaine%20in%20the%20term%20parturient%20:%20original%20research&rft.jtitle=Southern%20African%20journal%20of%20anaesthesia%20and%20analgesia&rft.au=Nadia,%20M.N.&rft.date=2010-05-01&rft.volume=16&rft.issue=3&rft.spage=30&rft.epage=33&rft.pages=30-33&rft.issn=2220-1181&rft.eissn=2220-1173&rft_id=info:doi/&rft_dat=%3Csabinet%3E10520/EJC73769%3C/sabinet%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_sabinet_id=10520/EJC73769&rfr_iscdi=true