Assessment of PM concentrations, transport, and mitigation in indoor environments using low-cost air quality monitors and a portable air cleaner
In this study, we deployed multiple low-cost air quality monitors (AQMs) to investigate the transport of kitchen-generated fine particulate matter (PM 2.5 ) into the bedrooms of four homes of different sizes over a period of more than nine weeks at each home. We also estimated the human exposure to...
Gespeichert in:
Veröffentlicht in: | Environmental science: atmospheres 2022-07, Vol.2 (4), p.647-658 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 658 |
---|---|
container_issue | 4 |
container_start_page | 647 |
container_title | Environmental science: atmospheres |
container_volume | 2 |
creator | Sankhyan, Sumit Witteman, Julia K Coyan, Steven Patel, Sameer Vance, Marina E |
description | In this study, we deployed multiple low-cost air quality monitors (AQMs) to investigate the transport of kitchen-generated fine particulate matter (PM
2.5
) into the bedrooms of four homes of different sizes over a period of more than nine weeks at each home. We also estimated the human exposure to PM
2.5
associated with each microenvironment and evaluated the effects of using a portable air cleaner (PAC) to reduce those exposures. To select the best AQM for these analyses, we compared the field response of five commercially available models with that of a research-grade optical particle spectrometer. The AirVisual AQM showed the best correlation during collocation phases with
R
2
values in the range of 0.5-0.9 during cooking and background periods for all locations. The bedroom monitors picked up cooking emissions from the kitchen area within 1-45 min depending on the layout of each home, and median PM
2.5
concentrations in the bedroom were up to 30% lower than those in the kitchen. Results from the exposure analysis suggest that PAC use is an important intervention strategy for reducing personal PM
2.5
exposure, especially in indoor environments where cooking is the main source of PM
2.5
concentrations. In three of the four homes using PAC consistently in the kitchen or bedroom area during intensive cooking periods reduced overall exposure values by 30-90%. Moreover, during nighttime periods, PAC usage in the bedroom area yielded the lowest levels of PM
2.5
exposure for all the homes.
We deployed multiple low-cost air quality monitors to investigate the transport of kitchen-generated fine particulate matter (PM
2.5
) into the bedrooms of four homes of different sizes over a period of more than nine weeks at each home. |
doi_str_mv | 10.1039/d2ea00025c |
format | Article |
fullrecord | <record><control><sourceid>rsc</sourceid><recordid>TN_cdi_rsc_primary_d2ea00025c</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>d2ea00025c</sourcerecordid><originalsourceid>FETCH-rsc_primary_d2ea00025c3</originalsourceid><addsrcrecordid>eNqFj0FLA0EMhQdBaNFeehfyA7o6u9uueBSpeBE89F7S2WlJmU1qMrX0X_iT7S6CR-FB8vLCB8-5aenvS18_PbRVRO99tQhXblw19byoG9-M3MRsP9zLav64GLvvZ7No1kXOIFv4eIcgHC5OMZOwzeCysR1E8wyQW-go027IgHq1IgqRv0iFe4rB0Yh3kORUBLEMSAqfR0yUz9AJUxa1gYTQU3GT4vATUkSOeuuut5gsTn7njbt7Xa5e3gq1sD4odajn9V-7-r_8B8hYV_k</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Assessment of PM concentrations, transport, and mitigation in indoor environments using low-cost air quality monitors and a portable air cleaner</title><source>DOAJ Directory of Open Access Journals</source><source>EZB Electronic Journals Library</source><creator>Sankhyan, Sumit ; Witteman, Julia K ; Coyan, Steven ; Patel, Sameer ; Vance, Marina E</creator><creatorcontrib>Sankhyan, Sumit ; Witteman, Julia K ; Coyan, Steven ; Patel, Sameer ; Vance, Marina E</creatorcontrib><description>In this study, we deployed multiple low-cost air quality monitors (AQMs) to investigate the transport of kitchen-generated fine particulate matter (PM
2.5
) into the bedrooms of four homes of different sizes over a period of more than nine weeks at each home. We also estimated the human exposure to PM
2.5
associated with each microenvironment and evaluated the effects of using a portable air cleaner (PAC) to reduce those exposures. To select the best AQM for these analyses, we compared the field response of five commercially available models with that of a research-grade optical particle spectrometer. The AirVisual AQM showed the best correlation during collocation phases with
R
2
values in the range of 0.5-0.9 during cooking and background periods for all locations. The bedroom monitors picked up cooking emissions from the kitchen area within 1-45 min depending on the layout of each home, and median PM
2.5
concentrations in the bedroom were up to 30% lower than those in the kitchen. Results from the exposure analysis suggest that PAC use is an important intervention strategy for reducing personal PM
2.5
exposure, especially in indoor environments where cooking is the main source of PM
2.5
concentrations. In three of the four homes using PAC consistently in the kitchen or bedroom area during intensive cooking periods reduced overall exposure values by 30-90%. Moreover, during nighttime periods, PAC usage in the bedroom area yielded the lowest levels of PM
2.5
exposure for all the homes.
We deployed multiple low-cost air quality monitors to investigate the transport of kitchen-generated fine particulate matter (PM
2.5
) into the bedrooms of four homes of different sizes over a period of more than nine weeks at each home.</description><identifier>EISSN: 2634-3606</identifier><identifier>DOI: 10.1039/d2ea00025c</identifier><ispartof>Environmental science: atmospheres, 2022-07, Vol.2 (4), p.647-658</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27903,27904</link.rule.ids></links><search><creatorcontrib>Sankhyan, Sumit</creatorcontrib><creatorcontrib>Witteman, Julia K</creatorcontrib><creatorcontrib>Coyan, Steven</creatorcontrib><creatorcontrib>Patel, Sameer</creatorcontrib><creatorcontrib>Vance, Marina E</creatorcontrib><title>Assessment of PM concentrations, transport, and mitigation in indoor environments using low-cost air quality monitors and a portable air cleaner</title><title>Environmental science: atmospheres</title><description>In this study, we deployed multiple low-cost air quality monitors (AQMs) to investigate the transport of kitchen-generated fine particulate matter (PM
2.5
) into the bedrooms of four homes of different sizes over a period of more than nine weeks at each home. We also estimated the human exposure to PM
2.5
associated with each microenvironment and evaluated the effects of using a portable air cleaner (PAC) to reduce those exposures. To select the best AQM for these analyses, we compared the field response of five commercially available models with that of a research-grade optical particle spectrometer. The AirVisual AQM showed the best correlation during collocation phases with
R
2
values in the range of 0.5-0.9 during cooking and background periods for all locations. The bedroom monitors picked up cooking emissions from the kitchen area within 1-45 min depending on the layout of each home, and median PM
2.5
concentrations in the bedroom were up to 30% lower than those in the kitchen. Results from the exposure analysis suggest that PAC use is an important intervention strategy for reducing personal PM
2.5
exposure, especially in indoor environments where cooking is the main source of PM
2.5
concentrations. In three of the four homes using PAC consistently in the kitchen or bedroom area during intensive cooking periods reduced overall exposure values by 30-90%. Moreover, during nighttime periods, PAC usage in the bedroom area yielded the lowest levels of PM
2.5
exposure for all the homes.
We deployed multiple low-cost air quality monitors to investigate the transport of kitchen-generated fine particulate matter (PM
2.5
) into the bedrooms of four homes of different sizes over a period of more than nine weeks at each home.</description><issn>2634-3606</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqFj0FLA0EMhQdBaNFeehfyA7o6u9uueBSpeBE89F7S2WlJmU1qMrX0X_iT7S6CR-FB8vLCB8-5aenvS18_PbRVRO99tQhXblw19byoG9-M3MRsP9zLav64GLvvZ7No1kXOIFv4eIcgHC5OMZOwzeCysR1E8wyQW-go027IgHq1IgqRv0iFe4rB0Yh3kORUBLEMSAqfR0yUz9AJUxa1gYTQU3GT4vATUkSOeuuut5gsTn7njbt7Xa5e3gq1sD4odajn9V-7-r_8B8hYV_k</recordid><startdate>20220714</startdate><enddate>20220714</enddate><creator>Sankhyan, Sumit</creator><creator>Witteman, Julia K</creator><creator>Coyan, Steven</creator><creator>Patel, Sameer</creator><creator>Vance, Marina E</creator><scope/></search><sort><creationdate>20220714</creationdate><title>Assessment of PM concentrations, transport, and mitigation in indoor environments using low-cost air quality monitors and a portable air cleaner</title><author>Sankhyan, Sumit ; Witteman, Julia K ; Coyan, Steven ; Patel, Sameer ; Vance, Marina E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-rsc_primary_d2ea00025c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sankhyan, Sumit</creatorcontrib><creatorcontrib>Witteman, Julia K</creatorcontrib><creatorcontrib>Coyan, Steven</creatorcontrib><creatorcontrib>Patel, Sameer</creatorcontrib><creatorcontrib>Vance, Marina E</creatorcontrib><jtitle>Environmental science: atmospheres</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sankhyan, Sumit</au><au>Witteman, Julia K</au><au>Coyan, Steven</au><au>Patel, Sameer</au><au>Vance, Marina E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessment of PM concentrations, transport, and mitigation in indoor environments using low-cost air quality monitors and a portable air cleaner</atitle><jtitle>Environmental science: atmospheres</jtitle><date>2022-07-14</date><risdate>2022</risdate><volume>2</volume><issue>4</issue><spage>647</spage><epage>658</epage><pages>647-658</pages><eissn>2634-3606</eissn><abstract>In this study, we deployed multiple low-cost air quality monitors (AQMs) to investigate the transport of kitchen-generated fine particulate matter (PM
2.5
) into the bedrooms of four homes of different sizes over a period of more than nine weeks at each home. We also estimated the human exposure to PM
2.5
associated with each microenvironment and evaluated the effects of using a portable air cleaner (PAC) to reduce those exposures. To select the best AQM for these analyses, we compared the field response of five commercially available models with that of a research-grade optical particle spectrometer. The AirVisual AQM showed the best correlation during collocation phases with
R
2
values in the range of 0.5-0.9 during cooking and background periods for all locations. The bedroom monitors picked up cooking emissions from the kitchen area within 1-45 min depending on the layout of each home, and median PM
2.5
concentrations in the bedroom were up to 30% lower than those in the kitchen. Results from the exposure analysis suggest that PAC use is an important intervention strategy for reducing personal PM
2.5
exposure, especially in indoor environments where cooking is the main source of PM
2.5
concentrations. In three of the four homes using PAC consistently in the kitchen or bedroom area during intensive cooking periods reduced overall exposure values by 30-90%. Moreover, during nighttime periods, PAC usage in the bedroom area yielded the lowest levels of PM
2.5
exposure for all the homes.
We deployed multiple low-cost air quality monitors to investigate the transport of kitchen-generated fine particulate matter (PM
2.5
) into the bedrooms of four homes of different sizes over a period of more than nine weeks at each home.</abstract><doi>10.1039/d2ea00025c</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2634-3606 |
ispartof | Environmental science: atmospheres, 2022-07, Vol.2 (4), p.647-658 |
issn | 2634-3606 |
language | |
recordid | cdi_rsc_primary_d2ea00025c |
source | DOAJ Directory of Open Access Journals; EZB Electronic Journals Library |
title | Assessment of PM concentrations, transport, and mitigation in indoor environments using low-cost air quality monitors and a portable air cleaner |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T21%3A01%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-rsc&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessment%20of%20PM%20concentrations,%20transport,%20and%20mitigation%20in%20indoor%20environments%20using%20low-cost%20air%20quality%20monitors%20and%20a%20portable%20air%20cleaner&rft.jtitle=Environmental%20science:%20atmospheres&rft.au=Sankhyan,%20Sumit&rft.date=2022-07-14&rft.volume=2&rft.issue=4&rft.spage=647&rft.epage=658&rft.pages=647-658&rft.eissn=2634-3606&rft_id=info:doi/10.1039/d2ea00025c&rft_dat=%3Crsc%3Ed2ea00025c%3C/rsc%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |