Solvent effects of ,-dimethylformamide and methanol on mass spectrometry imaging by tapping-mode scanning probe electrospray ionization

Mass spectrometry imaging (MSI) is an effective technique for visualizing the distribution of lipids in tissues. The direct extraction-ionization methods using minute volumes of solvent for local components have the advantage of rapid measurement without any sample pretreatment. For effective MSI of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analyst (London) 2023-03, Vol.148 (6), p.1275-1284
Hauptverfasser: Otsuka, Yoichi, Ote, Nijiho, Sun, Mengze, Shimma, Shuichi, Urakawa, Osamu, Yamaguchi, Shinichi, Kudo, Tomoya, Toyoda, Michisato
Format: Artikel
Sprache:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1284
container_issue 6
container_start_page 1275
container_title Analyst (London)
container_volume 148
creator Otsuka, Yoichi
Ote, Nijiho
Sun, Mengze
Shimma, Shuichi
Urakawa, Osamu
Yamaguchi, Shinichi
Kudo, Tomoya
Toyoda, Michisato
description Mass spectrometry imaging (MSI) is an effective technique for visualizing the distribution of lipids in tissues. The direct extraction-ionization methods using minute volumes of solvent for local components have the advantage of rapid measurement without any sample pretreatment. For effective MSI of tissues, it is necessary to understand the effect of solvent physicochemical properties on ion images. In this study, we report solvent effects on the lipid imaging of mouse brain tissue by tapping-mode scanning probe electrospray ionization (t-SPESI) which is capable of extraction-ionization using sub-pL solvents. To precisely measure lipid ions, we developed a measurement system incorporating a quadrupole-time-of-flight mass spectrometer. The differences in signal intensity and spatial resolution of lipid ion images were investigated using N , N -dimethylformamide (non-protic polar solvent), methanol (protic polar solvent) and their mixture. The mixed solvent was suitable for the protonation of lipids, and it provided high spatial resolution MSI. Results indicate that the mixed solvent improves the extractant transfer efficiency and minimizes charged droplets from an electrospray. The solvent selectivity study revealed the importance of solvent selection based on physicochemical properties for the advancement of MSI by t-SPESI. Development of a mass spectrometry imaging system utilizing t-SPESI and its application to lipid imaging of tissue sections. The effects of solvent properties on the extraction-ionization process and the spatial resolution of ion images are discussed.
doi_str_mv 10.1039/d2an01953a
format Article
fullrecord <record><control><sourceid>rsc</sourceid><recordid>TN_cdi_rsc_primary_d2an01953a</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>d2an01953a</sourcerecordid><originalsourceid>FETCH-rsc_primary_d2an01953a3</originalsourceid><addsrcrecordid>eNqFj81KBDEQhIMoOP5cvAv9AEaTyWZxz6J41_vSO5OskaQT0kEYX8DXNiuCR0_VVcVX0EJcaXWrldnczSOS0htr8EgM2qxX0trx_lgMSikjx7VdnYoz5vdutbJqEF8vOX44auC8d1NjyB5u5BySa29L9LkmTGF2gDTDIUPKETJBQmbg0pGae14XCAn3gfawW6BhKf2UKXeSJyQ6FKXmnQMXfxguFTuTKXxi63IhTjxGdpe_ei6unx5fH55l5Wlbah-vy_bvO_Nf_w0ON1aX</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Solvent effects of ,-dimethylformamide and methanol on mass spectrometry imaging by tapping-mode scanning probe electrospray ionization</title><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Otsuka, Yoichi ; Ote, Nijiho ; Sun, Mengze ; Shimma, Shuichi ; Urakawa, Osamu ; Yamaguchi, Shinichi ; Kudo, Tomoya ; Toyoda, Michisato</creator><creatorcontrib>Otsuka, Yoichi ; Ote, Nijiho ; Sun, Mengze ; Shimma, Shuichi ; Urakawa, Osamu ; Yamaguchi, Shinichi ; Kudo, Tomoya ; Toyoda, Michisato</creatorcontrib><description>Mass spectrometry imaging (MSI) is an effective technique for visualizing the distribution of lipids in tissues. The direct extraction-ionization methods using minute volumes of solvent for local components have the advantage of rapid measurement without any sample pretreatment. For effective MSI of tissues, it is necessary to understand the effect of solvent physicochemical properties on ion images. In this study, we report solvent effects on the lipid imaging of mouse brain tissue by tapping-mode scanning probe electrospray ionization (t-SPESI) which is capable of extraction-ionization using sub-pL solvents. To precisely measure lipid ions, we developed a measurement system incorporating a quadrupole-time-of-flight mass spectrometer. The differences in signal intensity and spatial resolution of lipid ion images were investigated using N , N -dimethylformamide (non-protic polar solvent), methanol (protic polar solvent) and their mixture. The mixed solvent was suitable for the protonation of lipids, and it provided high spatial resolution MSI. Results indicate that the mixed solvent improves the extractant transfer efficiency and minimizes charged droplets from an electrospray. The solvent selectivity study revealed the importance of solvent selection based on physicochemical properties for the advancement of MSI by t-SPESI. Development of a mass spectrometry imaging system utilizing t-SPESI and its application to lipid imaging of tissue sections. The effects of solvent properties on the extraction-ionization process and the spatial resolution of ion images are discussed.</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/d2an01953a</identifier><ispartof>Analyst (London), 2023-03, Vol.148 (6), p.1275-1284</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2831,27923,27924</link.rule.ids></links><search><creatorcontrib>Otsuka, Yoichi</creatorcontrib><creatorcontrib>Ote, Nijiho</creatorcontrib><creatorcontrib>Sun, Mengze</creatorcontrib><creatorcontrib>Shimma, Shuichi</creatorcontrib><creatorcontrib>Urakawa, Osamu</creatorcontrib><creatorcontrib>Yamaguchi, Shinichi</creatorcontrib><creatorcontrib>Kudo, Tomoya</creatorcontrib><creatorcontrib>Toyoda, Michisato</creatorcontrib><title>Solvent effects of ,-dimethylformamide and methanol on mass spectrometry imaging by tapping-mode scanning probe electrospray ionization</title><title>Analyst (London)</title><description>Mass spectrometry imaging (MSI) is an effective technique for visualizing the distribution of lipids in tissues. The direct extraction-ionization methods using minute volumes of solvent for local components have the advantage of rapid measurement without any sample pretreatment. For effective MSI of tissues, it is necessary to understand the effect of solvent physicochemical properties on ion images. In this study, we report solvent effects on the lipid imaging of mouse brain tissue by tapping-mode scanning probe electrospray ionization (t-SPESI) which is capable of extraction-ionization using sub-pL solvents. To precisely measure lipid ions, we developed a measurement system incorporating a quadrupole-time-of-flight mass spectrometer. The differences in signal intensity and spatial resolution of lipid ion images were investigated using N , N -dimethylformamide (non-protic polar solvent), methanol (protic polar solvent) and their mixture. The mixed solvent was suitable for the protonation of lipids, and it provided high spatial resolution MSI. Results indicate that the mixed solvent improves the extractant transfer efficiency and minimizes charged droplets from an electrospray. The solvent selectivity study revealed the importance of solvent selection based on physicochemical properties for the advancement of MSI by t-SPESI. Development of a mass spectrometry imaging system utilizing t-SPESI and its application to lipid imaging of tissue sections. The effects of solvent properties on the extraction-ionization process and the spatial resolution of ion images are discussed.</description><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqFj81KBDEQhIMoOP5cvAv9AEaTyWZxz6J41_vSO5OskaQT0kEYX8DXNiuCR0_VVcVX0EJcaXWrldnczSOS0htr8EgM2qxX0trx_lgMSikjx7VdnYoz5vdutbJqEF8vOX44auC8d1NjyB5u5BySa29L9LkmTGF2gDTDIUPKETJBQmbg0pGae14XCAn3gfawW6BhKf2UKXeSJyQ6FKXmnQMXfxguFTuTKXxi63IhTjxGdpe_ei6unx5fH55l5Wlbah-vy_bvO_Nf_w0ON1aX</recordid><startdate>20230313</startdate><enddate>20230313</enddate><creator>Otsuka, Yoichi</creator><creator>Ote, Nijiho</creator><creator>Sun, Mengze</creator><creator>Shimma, Shuichi</creator><creator>Urakawa, Osamu</creator><creator>Yamaguchi, Shinichi</creator><creator>Kudo, Tomoya</creator><creator>Toyoda, Michisato</creator><scope/></search><sort><creationdate>20230313</creationdate><title>Solvent effects of ,-dimethylformamide and methanol on mass spectrometry imaging by tapping-mode scanning probe electrospray ionization</title><author>Otsuka, Yoichi ; Ote, Nijiho ; Sun, Mengze ; Shimma, Shuichi ; Urakawa, Osamu ; Yamaguchi, Shinichi ; Kudo, Tomoya ; Toyoda, Michisato</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-rsc_primary_d2an01953a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Otsuka, Yoichi</creatorcontrib><creatorcontrib>Ote, Nijiho</creatorcontrib><creatorcontrib>Sun, Mengze</creatorcontrib><creatorcontrib>Shimma, Shuichi</creatorcontrib><creatorcontrib>Urakawa, Osamu</creatorcontrib><creatorcontrib>Yamaguchi, Shinichi</creatorcontrib><creatorcontrib>Kudo, Tomoya</creatorcontrib><creatorcontrib>Toyoda, Michisato</creatorcontrib><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Otsuka, Yoichi</au><au>Ote, Nijiho</au><au>Sun, Mengze</au><au>Shimma, Shuichi</au><au>Urakawa, Osamu</au><au>Yamaguchi, Shinichi</au><au>Kudo, Tomoya</au><au>Toyoda, Michisato</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Solvent effects of ,-dimethylformamide and methanol on mass spectrometry imaging by tapping-mode scanning probe electrospray ionization</atitle><jtitle>Analyst (London)</jtitle><date>2023-03-13</date><risdate>2023</risdate><volume>148</volume><issue>6</issue><spage>1275</spage><epage>1284</epage><pages>1275-1284</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><abstract>Mass spectrometry imaging (MSI) is an effective technique for visualizing the distribution of lipids in tissues. The direct extraction-ionization methods using minute volumes of solvent for local components have the advantage of rapid measurement without any sample pretreatment. For effective MSI of tissues, it is necessary to understand the effect of solvent physicochemical properties on ion images. In this study, we report solvent effects on the lipid imaging of mouse brain tissue by tapping-mode scanning probe electrospray ionization (t-SPESI) which is capable of extraction-ionization using sub-pL solvents. To precisely measure lipid ions, we developed a measurement system incorporating a quadrupole-time-of-flight mass spectrometer. The differences in signal intensity and spatial resolution of lipid ion images were investigated using N , N -dimethylformamide (non-protic polar solvent), methanol (protic polar solvent) and their mixture. The mixed solvent was suitable for the protonation of lipids, and it provided high spatial resolution MSI. Results indicate that the mixed solvent improves the extractant transfer efficiency and minimizes charged droplets from an electrospray. The solvent selectivity study revealed the importance of solvent selection based on physicochemical properties for the advancement of MSI by t-SPESI. Development of a mass spectrometry imaging system utilizing t-SPESI and its application to lipid imaging of tissue sections. The effects of solvent properties on the extraction-ionization process and the spatial resolution of ion images are discussed.</abstract><doi>10.1039/d2an01953a</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2654
ispartof Analyst (London), 2023-03, Vol.148 (6), p.1275-1284
issn 0003-2654
1364-5528
language
recordid cdi_rsc_primary_d2an01953a
source Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
title Solvent effects of ,-dimethylformamide and methanol on mass spectrometry imaging by tapping-mode scanning probe electrospray ionization
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T08%3A22%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-rsc&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Solvent%20effects%20of%20,-dimethylformamide%20and%20methanol%20on%20mass%20spectrometry%20imaging%20by%20tapping-mode%20scanning%20probe%20electrospray%20ionization&rft.jtitle=Analyst%20(London)&rft.au=Otsuka,%20Yoichi&rft.date=2023-03-13&rft.volume=148&rft.issue=6&rft.spage=1275&rft.epage=1284&rft.pages=1275-1284&rft.issn=0003-2654&rft.eissn=1364-5528&rft_id=info:doi/10.1039/d2an01953a&rft_dat=%3Crsc%3Ed2an01953a%3C/rsc%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true