Label-free isolation of rare tumor cells from untreated whole blood by interfacial viscoelastic microfluidics

Label-free, high-throughput, and efficient separation and enrichment of rare tumor cells, such as circulating tumor cells (CTCs), from untreated whole blood is a challenging task, owing to extremely rare events of CTCs and an enormous amount of blood cells. Current strategies for CTC separation alwa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lab on a chip 2018-11, Vol.18 (22), p.3436-3445
Hauptverfasser: Tian, Fei, Cai, Lili, Chang, Jianqiao, Li, Shanshan, Liu, Chao, Li, Tiejun, Sun, Jiashu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3445
container_issue 22
container_start_page 3436
container_title Lab on a chip
container_volume 18
creator Tian, Fei
Cai, Lili
Chang, Jianqiao
Li, Shanshan
Liu, Chao
Li, Tiejun
Sun, Jiashu
description Label-free, high-throughput, and efficient separation and enrichment of rare tumor cells, such as circulating tumor cells (CTCs), from untreated whole blood is a challenging task, owing to extremely rare events of CTCs and an enormous amount of blood cells. Current strategies for CTC separation always require pre-processing steps including lysis of blood or labeling of CTCs, leading to loss or damage of CTCs. Here, we report an interfacial viscoelastic microfluidic system for size-selective separation of tumor cells directly from whole blood, without the need of cell labeling and other treatments. The sharp flow interfaces between the sample flow and viscoelastic flow (0.05% PEO solutions) in the straight microchannel allow for the penetration of large tumor cells while blocking small blood cells, through exploiting the competition between the inertial lift forces and interfacial elastic lift forces. The microfluidic paradigm does not involve external force fields or complicated fabrication procedures, while achieving 95.1% separation efficiency and 77.5% recovery rate for isolating as few as 50 tumor cells in 1 mL whole blood. The viability of tumor cells after separation is ∼100%, and normal proliferation of separated tumor cells is observed. The interfacial viscoelastic microfluidics holds great promise to facilitate the fundamental and clinical studies of CTCs. Label-free, size-dependent, and high-throughput isolation of rare tumor cells from untreated whole blood is enabled by interfacial viscoelastic microfluidics.
doi_str_mv 10.1039/c8lc00700d
format Article
fullrecord <record><control><sourceid>proquest_rsc_p</sourceid><recordid>TN_cdi_rsc_primary_c8lc00700d</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2130081029</sourcerecordid><originalsourceid>FETCH-LOGICAL-c444t-7c4fd3b521b8583cb6ca72d5513e92620100698caecf5e3a0b4e8c7ba225a8af3</originalsourceid><addsrcrecordid>eNpd0c9LHTEQB_AgFZ_aXrxbAr1IYevkx-5mj_K0VXjgpT0vSXZC88huNNmt-N839dkneJrAfBhm8iXkjME3BqK7tCpYgBZgOCDHTLaiAqa6D_t3167ISc5bAFbLRh2RlQDBlZTNMRk32mCoXEKkPsegZx8nGh1NOiGdlzEmajGETF2KI12mOaGecaBPv2NAakKMAzXP1E8zJqet14H-8dlGDDrP3tLR2xRdWPzgbf5IDp0OGT-91lPy6_vNz_Vttbn_cbe-2lRWSjlXrZVuEKbmzKhaCWsaq1s-1DUT2PGGAwNoOmU1Wlej0GAkKtsazXmtlXbilFzs5j6k-Lhgnvux7FTO0BPGJfeccSY70TBe6Jd3dBuXNJXtihIAigHvivq6U-WYnBO6_iH5UafnnkH_L4R-rTbrlxCuC_78OnIxIw57-v_XCzjfgZTtvvuWovgLdE6MqA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2130081029</pqid></control><display><type>article</type><title>Label-free isolation of rare tumor cells from untreated whole blood by interfacial viscoelastic microfluidics</title><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Tian, Fei ; Cai, Lili ; Chang, Jianqiao ; Li, Shanshan ; Liu, Chao ; Li, Tiejun ; Sun, Jiashu</creator><creatorcontrib>Tian, Fei ; Cai, Lili ; Chang, Jianqiao ; Li, Shanshan ; Liu, Chao ; Li, Tiejun ; Sun, Jiashu</creatorcontrib><description>Label-free, high-throughput, and efficient separation and enrichment of rare tumor cells, such as circulating tumor cells (CTCs), from untreated whole blood is a challenging task, owing to extremely rare events of CTCs and an enormous amount of blood cells. Current strategies for CTC separation always require pre-processing steps including lysis of blood or labeling of CTCs, leading to loss or damage of CTCs. Here, we report an interfacial viscoelastic microfluidic system for size-selective separation of tumor cells directly from whole blood, without the need of cell labeling and other treatments. The sharp flow interfaces between the sample flow and viscoelastic flow (0.05% PEO solutions) in the straight microchannel allow for the penetration of large tumor cells while blocking small blood cells, through exploiting the competition between the inertial lift forces and interfacial elastic lift forces. The microfluidic paradigm does not involve external force fields or complicated fabrication procedures, while achieving 95.1% separation efficiency and 77.5% recovery rate for isolating as few as 50 tumor cells in 1 mL whole blood. The viability of tumor cells after separation is ∼100%, and normal proliferation of separated tumor cells is observed. The interfacial viscoelastic microfluidics holds great promise to facilitate the fundamental and clinical studies of CTCs. Label-free, size-dependent, and high-throughput isolation of rare tumor cells from untreated whole blood is enabled by interfacial viscoelastic microfluidics.</description><identifier>ISSN: 1473-0197</identifier><identifier>EISSN: 1473-0189</identifier><identifier>DOI: 10.1039/c8lc00700d</identifier><identifier>PMID: 30328446</identifier><language>eng</language><publisher>England: Royal Society of Chemistry</publisher><subject>Blood cells ; Blood circulation ; Labeling ; Microchannels ; Microfluidics ; Separation ; Tumors ; Viability ; Viscoelasticity</subject><ispartof>Lab on a chip, 2018-11, Vol.18 (22), p.3436-3445</ispartof><rights>Copyright Royal Society of Chemistry 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c444t-7c4fd3b521b8583cb6ca72d5513e92620100698caecf5e3a0b4e8c7ba225a8af3</citedby><cites>FETCH-LOGICAL-c444t-7c4fd3b521b8583cb6ca72d5513e92620100698caecf5e3a0b4e8c7ba225a8af3</cites><orcidid>0000-0003-4255-6202</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30328446$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tian, Fei</creatorcontrib><creatorcontrib>Cai, Lili</creatorcontrib><creatorcontrib>Chang, Jianqiao</creatorcontrib><creatorcontrib>Li, Shanshan</creatorcontrib><creatorcontrib>Liu, Chao</creatorcontrib><creatorcontrib>Li, Tiejun</creatorcontrib><creatorcontrib>Sun, Jiashu</creatorcontrib><title>Label-free isolation of rare tumor cells from untreated whole blood by interfacial viscoelastic microfluidics</title><title>Lab on a chip</title><addtitle>Lab Chip</addtitle><description>Label-free, high-throughput, and efficient separation and enrichment of rare tumor cells, such as circulating tumor cells (CTCs), from untreated whole blood is a challenging task, owing to extremely rare events of CTCs and an enormous amount of blood cells. Current strategies for CTC separation always require pre-processing steps including lysis of blood or labeling of CTCs, leading to loss or damage of CTCs. Here, we report an interfacial viscoelastic microfluidic system for size-selective separation of tumor cells directly from whole blood, without the need of cell labeling and other treatments. The sharp flow interfaces between the sample flow and viscoelastic flow (0.05% PEO solutions) in the straight microchannel allow for the penetration of large tumor cells while blocking small blood cells, through exploiting the competition between the inertial lift forces and interfacial elastic lift forces. The microfluidic paradigm does not involve external force fields or complicated fabrication procedures, while achieving 95.1% separation efficiency and 77.5% recovery rate for isolating as few as 50 tumor cells in 1 mL whole blood. The viability of tumor cells after separation is ∼100%, and normal proliferation of separated tumor cells is observed. The interfacial viscoelastic microfluidics holds great promise to facilitate the fundamental and clinical studies of CTCs. Label-free, size-dependent, and high-throughput isolation of rare tumor cells from untreated whole blood is enabled by interfacial viscoelastic microfluidics.</description><subject>Blood cells</subject><subject>Blood circulation</subject><subject>Labeling</subject><subject>Microchannels</subject><subject>Microfluidics</subject><subject>Separation</subject><subject>Tumors</subject><subject>Viability</subject><subject>Viscoelasticity</subject><issn>1473-0197</issn><issn>1473-0189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpd0c9LHTEQB_AgFZ_aXrxbAr1IYevkx-5mj_K0VXjgpT0vSXZC88huNNmt-N839dkneJrAfBhm8iXkjME3BqK7tCpYgBZgOCDHTLaiAqa6D_t3167ISc5bAFbLRh2RlQDBlZTNMRk32mCoXEKkPsegZx8nGh1NOiGdlzEmajGETF2KI12mOaGecaBPv2NAakKMAzXP1E8zJqet14H-8dlGDDrP3tLR2xRdWPzgbf5IDp0OGT-91lPy6_vNz_Vttbn_cbe-2lRWSjlXrZVuEKbmzKhaCWsaq1s-1DUT2PGGAwNoOmU1Wlej0GAkKtsazXmtlXbilFzs5j6k-Lhgnvux7FTO0BPGJfeccSY70TBe6Jd3dBuXNJXtihIAigHvivq6U-WYnBO6_iH5UafnnkH_L4R-rTbrlxCuC_78OnIxIw57-v_XCzjfgZTtvvuWovgLdE6MqA</recordid><startdate>20181106</startdate><enddate>20181106</enddate><creator>Tian, Fei</creator><creator>Cai, Lili</creator><creator>Chang, Jianqiao</creator><creator>Li, Shanshan</creator><creator>Liu, Chao</creator><creator>Li, Tiejun</creator><creator>Sun, Jiashu</creator><general>Royal Society of Chemistry</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4255-6202</orcidid></search><sort><creationdate>20181106</creationdate><title>Label-free isolation of rare tumor cells from untreated whole blood by interfacial viscoelastic microfluidics</title><author>Tian, Fei ; Cai, Lili ; Chang, Jianqiao ; Li, Shanshan ; Liu, Chao ; Li, Tiejun ; Sun, Jiashu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c444t-7c4fd3b521b8583cb6ca72d5513e92620100698caecf5e3a0b4e8c7ba225a8af3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Blood cells</topic><topic>Blood circulation</topic><topic>Labeling</topic><topic>Microchannels</topic><topic>Microfluidics</topic><topic>Separation</topic><topic>Tumors</topic><topic>Viability</topic><topic>Viscoelasticity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tian, Fei</creatorcontrib><creatorcontrib>Cai, Lili</creatorcontrib><creatorcontrib>Chang, Jianqiao</creatorcontrib><creatorcontrib>Li, Shanshan</creatorcontrib><creatorcontrib>Liu, Chao</creatorcontrib><creatorcontrib>Li, Tiejun</creatorcontrib><creatorcontrib>Sun, Jiashu</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Lab on a chip</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tian, Fei</au><au>Cai, Lili</au><au>Chang, Jianqiao</au><au>Li, Shanshan</au><au>Liu, Chao</au><au>Li, Tiejun</au><au>Sun, Jiashu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Label-free isolation of rare tumor cells from untreated whole blood by interfacial viscoelastic microfluidics</atitle><jtitle>Lab on a chip</jtitle><addtitle>Lab Chip</addtitle><date>2018-11-06</date><risdate>2018</risdate><volume>18</volume><issue>22</issue><spage>3436</spage><epage>3445</epage><pages>3436-3445</pages><issn>1473-0197</issn><eissn>1473-0189</eissn><abstract>Label-free, high-throughput, and efficient separation and enrichment of rare tumor cells, such as circulating tumor cells (CTCs), from untreated whole blood is a challenging task, owing to extremely rare events of CTCs and an enormous amount of blood cells. Current strategies for CTC separation always require pre-processing steps including lysis of blood or labeling of CTCs, leading to loss or damage of CTCs. Here, we report an interfacial viscoelastic microfluidic system for size-selective separation of tumor cells directly from whole blood, without the need of cell labeling and other treatments. The sharp flow interfaces between the sample flow and viscoelastic flow (0.05% PEO solutions) in the straight microchannel allow for the penetration of large tumor cells while blocking small blood cells, through exploiting the competition between the inertial lift forces and interfacial elastic lift forces. The microfluidic paradigm does not involve external force fields or complicated fabrication procedures, while achieving 95.1% separation efficiency and 77.5% recovery rate for isolating as few as 50 tumor cells in 1 mL whole blood. The viability of tumor cells after separation is ∼100%, and normal proliferation of separated tumor cells is observed. The interfacial viscoelastic microfluidics holds great promise to facilitate the fundamental and clinical studies of CTCs. Label-free, size-dependent, and high-throughput isolation of rare tumor cells from untreated whole blood is enabled by interfacial viscoelastic microfluidics.</abstract><cop>England</cop><pub>Royal Society of Chemistry</pub><pmid>30328446</pmid><doi>10.1039/c8lc00700d</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0003-4255-6202</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1473-0197
ispartof Lab on a chip, 2018-11, Vol.18 (22), p.3436-3445
issn 1473-0197
1473-0189
language eng
recordid cdi_rsc_primary_c8lc00700d
source Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Blood cells
Blood circulation
Labeling
Microchannels
Microfluidics
Separation
Tumors
Viability
Viscoelasticity
title Label-free isolation of rare tumor cells from untreated whole blood by interfacial viscoelastic microfluidics
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T14%3A27%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_rsc_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Label-free%20isolation%20of%20rare%20tumor%20cells%20from%20untreated%20whole%20blood%20by%20interfacial%20viscoelastic%20microfluidics&rft.jtitle=Lab%20on%20a%20chip&rft.au=Tian,%20Fei&rft.date=2018-11-06&rft.volume=18&rft.issue=22&rft.spage=3436&rft.epage=3445&rft.pages=3436-3445&rft.issn=1473-0197&rft.eissn=1473-0189&rft_id=info:doi/10.1039/c8lc00700d&rft_dat=%3Cproquest_rsc_p%3E2130081029%3C/proquest_rsc_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2130081029&rft_id=info:pmid/30328446&rfr_iscdi=true