A fluorometric microarray with ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassaysElectronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06070b
A glass slide was first patterned with hydrophobic hexadecyltrimethoxysilane (HDS) and then microspotted with hydrophilic ZnO nanoparticles in an aminopropyltriethoxysilane (APS) matrix. The resulting HDS-ZnO-APS microarray could present the capability of suppressing the undesirable "coffee-rin...
Gespeichert in:
Hauptverfasser: | , , , , , , , |
---|---|
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 18458 |
---|---|
container_issue | 44 |
container_start_page | 18453 |
container_title | |
container_volume | 7 |
creator | Li, Shuying Dong, Minmin Li, Rui Zhang, Liyan Qiao, Yuchun Jiang, Yao Qi, Wei Wang, Hua |
description | A glass slide was first patterned with hydrophobic hexadecyltrimethoxysilane (HDS) and then microspotted with hydrophilic ZnO nanoparticles in an aminopropyltriethoxysilane (APS) matrix. The resulting HDS-ZnO-APS microarray could present the capability of suppressing the undesirable "coffee-ring" effects through its hydrophobic pattern so as to allow the fabrication of ZnO-APS testing microspots with a highly dense and uniform distribution. The lotus-like "self-cleaning" function could also be expected to effectively curb the cross contamination of multiple sample droplets. More importantly, the introduction of ZnO nanoparticles could endow the testing microspots with substrate-enhanced fluorescence leading to signal-amplification microarray fluorometry. The practical application of the developed HDS-ZnO-APS microarray was investigated by the sandwiched fluorometric immunoassays of human IgG, showing a linear detection range from 0.010 to 10.0 ng mL
−1
. Such a throughput-improved fluorometric microarray could be tailored for probing multiple biomarkers in complicated media like serum or blood.
A fluorometric microarray was fabricated with hydrophobic silicane and ZnO nanoparticles showing ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassays. |
doi_str_mv | 10.1039/c5nr06070b |
format | Article |
fullrecord | <record><control><sourceid>rsc</sourceid><recordid>TN_cdi_rsc_primary_c5nr06070b</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>c5nr06070b</sourcerecordid><originalsourceid>FETCH-rsc_primary_c5nr06070b3</originalsourceid><addsrcrecordid>eNqFT01LAzEQDaJgrV68C2NPetiaNnVLvUmt2FMP9eSlTNOJjWySZZJV9o_6e4woigh6mjfzPngjxPFA9gdSTS70pWdZyrFc74jOUI5kodR4uPuFy9G-OIjxScpyokrVEa_XYKomcHCU2GpwVnNAZmzhxaYtPPgFxGYdE2OigvwWvabNh4eiprwB-k3W1HU-xMz1dDCGqGDrH3tAGesUwQT-6bLONT5gjNjGWZU1HHwu8B5UkSOfkFuwPvscJhs8nM2W83PAZ7QVrivqw5IIbhbzK_j9_aHYM1hFOvqcXXFyO7uf3hUc9apm63L46luuuuL0L35Vb4z6L-MNRbB8aA</addsrcrecordid><sourcetype>Enrichment Source</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A fluorometric microarray with ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassaysElectronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06070b</title><source>Royal Society Of Chemistry Journals</source><source>Alma/SFX Local Collection</source><creator>Li, Shuying ; Dong, Minmin ; Li, Rui ; Zhang, Liyan ; Qiao, Yuchun ; Jiang, Yao ; Qi, Wei ; Wang, Hua</creator><creatorcontrib>Li, Shuying ; Dong, Minmin ; Li, Rui ; Zhang, Liyan ; Qiao, Yuchun ; Jiang, Yao ; Qi, Wei ; Wang, Hua</creatorcontrib><description>A glass slide was first patterned with hydrophobic hexadecyltrimethoxysilane (HDS) and then microspotted with hydrophilic ZnO nanoparticles in an aminopropyltriethoxysilane (APS) matrix. The resulting HDS-ZnO-APS microarray could present the capability of suppressing the undesirable "coffee-ring" effects through its hydrophobic pattern so as to allow the fabrication of ZnO-APS testing microspots with a highly dense and uniform distribution. The lotus-like "self-cleaning" function could also be expected to effectively curb the cross contamination of multiple sample droplets. More importantly, the introduction of ZnO nanoparticles could endow the testing microspots with substrate-enhanced fluorescence leading to signal-amplification microarray fluorometry. The practical application of the developed HDS-ZnO-APS microarray was investigated by the sandwiched fluorometric immunoassays of human IgG, showing a linear detection range from 0.010 to 10.0 ng mL
−1
. Such a throughput-improved fluorometric microarray could be tailored for probing multiple biomarkers in complicated media like serum or blood.
A fluorometric microarray was fabricated with hydrophobic silicane and ZnO nanoparticles showing ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassays.</description><identifier>ISSN: 2040-3364</identifier><identifier>EISSN: 2040-3372</identifier><identifier>DOI: 10.1039/c5nr06070b</identifier><language>eng</language><creationdate>2015-11</creationdate><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Li, Shuying</creatorcontrib><creatorcontrib>Dong, Minmin</creatorcontrib><creatorcontrib>Li, Rui</creatorcontrib><creatorcontrib>Zhang, Liyan</creatorcontrib><creatorcontrib>Qiao, Yuchun</creatorcontrib><creatorcontrib>Jiang, Yao</creatorcontrib><creatorcontrib>Qi, Wei</creatorcontrib><creatorcontrib>Wang, Hua</creatorcontrib><title>A fluorometric microarray with ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassaysElectronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06070b</title><description>A glass slide was first patterned with hydrophobic hexadecyltrimethoxysilane (HDS) and then microspotted with hydrophilic ZnO nanoparticles in an aminopropyltriethoxysilane (APS) matrix. The resulting HDS-ZnO-APS microarray could present the capability of suppressing the undesirable "coffee-ring" effects through its hydrophobic pattern so as to allow the fabrication of ZnO-APS testing microspots with a highly dense and uniform distribution. The lotus-like "self-cleaning" function could also be expected to effectively curb the cross contamination of multiple sample droplets. More importantly, the introduction of ZnO nanoparticles could endow the testing microspots with substrate-enhanced fluorescence leading to signal-amplification microarray fluorometry. The practical application of the developed HDS-ZnO-APS microarray was investigated by the sandwiched fluorometric immunoassays of human IgG, showing a linear detection range from 0.010 to 10.0 ng mL
−1
. Such a throughput-improved fluorometric microarray could be tailored for probing multiple biomarkers in complicated media like serum or blood.
A fluorometric microarray was fabricated with hydrophobic silicane and ZnO nanoparticles showing ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassays.</description><issn>2040-3364</issn><issn>2040-3372</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqFT01LAzEQDaJgrV68C2NPetiaNnVLvUmt2FMP9eSlTNOJjWySZZJV9o_6e4woigh6mjfzPngjxPFA9gdSTS70pWdZyrFc74jOUI5kodR4uPuFy9G-OIjxScpyokrVEa_XYKomcHCU2GpwVnNAZmzhxaYtPPgFxGYdE2OigvwWvabNh4eiprwB-k3W1HU-xMz1dDCGqGDrH3tAGesUwQT-6bLONT5gjNjGWZU1HHwu8B5UkSOfkFuwPvscJhs8nM2W83PAZ7QVrivqw5IIbhbzK_j9_aHYM1hFOvqcXXFyO7uf3hUc9apm63L46luuuuL0L35Vb4z6L-MNRbB8aA</recordid><startdate>20151105</startdate><enddate>20151105</enddate><creator>Li, Shuying</creator><creator>Dong, Minmin</creator><creator>Li, Rui</creator><creator>Zhang, Liyan</creator><creator>Qiao, Yuchun</creator><creator>Jiang, Yao</creator><creator>Qi, Wei</creator><creator>Wang, Hua</creator><scope/></search><sort><creationdate>20151105</creationdate><title>A fluorometric microarray with ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassaysElectronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06070b</title><author>Li, Shuying ; Dong, Minmin ; Li, Rui ; Zhang, Liyan ; Qiao, Yuchun ; Jiang, Yao ; Qi, Wei ; Wang, Hua</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-rsc_primary_c5nr06070b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, Shuying</creatorcontrib><creatorcontrib>Dong, Minmin</creatorcontrib><creatorcontrib>Li, Rui</creatorcontrib><creatorcontrib>Zhang, Liyan</creatorcontrib><creatorcontrib>Qiao, Yuchun</creatorcontrib><creatorcontrib>Jiang, Yao</creatorcontrib><creatorcontrib>Qi, Wei</creatorcontrib><creatorcontrib>Wang, Hua</creatorcontrib></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Shuying</au><au>Dong, Minmin</au><au>Li, Rui</au><au>Zhang, Liyan</au><au>Qiao, Yuchun</au><au>Jiang, Yao</au><au>Qi, Wei</au><au>Wang, Hua</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A fluorometric microarray with ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassaysElectronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06070b</atitle><date>2015-11-05</date><risdate>2015</risdate><volume>7</volume><issue>44</issue><spage>18453</spage><epage>18458</epage><pages>18453-18458</pages><issn>2040-3364</issn><eissn>2040-3372</eissn><abstract>A glass slide was first patterned with hydrophobic hexadecyltrimethoxysilane (HDS) and then microspotted with hydrophilic ZnO nanoparticles in an aminopropyltriethoxysilane (APS) matrix. The resulting HDS-ZnO-APS microarray could present the capability of suppressing the undesirable "coffee-ring" effects through its hydrophobic pattern so as to allow the fabrication of ZnO-APS testing microspots with a highly dense and uniform distribution. The lotus-like "self-cleaning" function could also be expected to effectively curb the cross contamination of multiple sample droplets. More importantly, the introduction of ZnO nanoparticles could endow the testing microspots with substrate-enhanced fluorescence leading to signal-amplification microarray fluorometry. The practical application of the developed HDS-ZnO-APS microarray was investigated by the sandwiched fluorometric immunoassays of human IgG, showing a linear detection range from 0.010 to 10.0 ng mL
−1
. Such a throughput-improved fluorometric microarray could be tailored for probing multiple biomarkers in complicated media like serum or blood.
A fluorometric microarray was fabricated with hydrophobic silicane and ZnO nanoparticles showing ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassays.</abstract><doi>10.1039/c5nr06070b</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2040-3364 |
ispartof | |
issn | 2040-3364 2040-3372 |
language | eng |
recordid | cdi_rsc_primary_c5nr06070b |
source | Royal Society Of Chemistry Journals; Alma/SFX Local Collection |
title | A fluorometric microarray with ZnO substrate-enhanced fluorescence and suppressed "coffee-ring" effects for fluorescence immunoassaysElectronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06070b |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T13%3A47%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-rsc&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20fluorometric%20microarray%20with%20ZnO%20substrate-enhanced%20fluorescence%20and%20suppressed%20%22coffee-ring%22%20effects%20for%20fluorescence%20immunoassaysElectronic%20supplementary%20information%20(ESI)%20available.%20See%20DOI:%2010.1039/c5nr06070b&rft.au=Li,%20Shuying&rft.date=2015-11-05&rft.volume=7&rft.issue=44&rft.spage=18453&rft.epage=18458&rft.pages=18453-18458&rft.issn=2040-3364&rft.eissn=2040-3372&rft_id=info:doi/10.1039/c5nr06070b&rft_dat=%3Crsc%3Ec5nr06070b%3C/rsc%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |